Support correct data exchange in Clear state #2

Open
Rahix opened this issue Dec 28, 2023 · 0 comments
Open

Support correct data exchange in Clear state #2

Rahix opened this issue Dec 28, 2023 · 0 comments
Labels
correctness Behavioral Correctness of the Stack dp PROFIBUS-DP good first issue Good for newcomers

Comments

@Rahix
Copy link
Owner

Rahix commented Dec 28, 2023

We should properly evaluate the Fail_Safe setting from the GSD file. If set, we shouldn't send any PI_q in Clear operating mode. If Fail_Safe is not set, the current behavior of sending all zeros is correct.

Fail_Safe is exposed as of commit a4c53f6 ("gsdtool: Emit fail_safe field").

@Rahix Rahix added dp PROFIBUS-DP correctness Behavioral Correctness of the Stack labels Dec 28, 2023