[1.0.1] - 2025-2-1

  • add convenience method to read out measurements again

1.0.0 - 2025-1-30

Added

  • All commands according to data sheet

Changed

Note that there are breaking changes:

  • You need to call scd4x_init(SCD41_I2C_ADDR_62); before sending any command t
  • all methods that have been named xxxTicks are now named xxxRaw
  • getDataReadyFlag has been renamed to getDataReadyStatus
  • data type for parameter count in HAL implementation has been changed from uint16_t to uint8_t
  • scd4x_set_ambient_pressure takes now a uint32_t in Pa and scd4x_set_ambient_pressure_raw takes a uint16_t in hPa
  • scd4x_get_ambient_pressure returns now a uint32_t in Pa and scd4x_get_ambient_pressure_raw returns a uint16_t in hPa
  • scd4x_get_automatic_self_calibration/scd4x_set_automatic_self_calibration has been renamed to scd4x_get_automatic_self_calibration_enabled/scd4x_set_automatic_self_calibration_enabled
  • signature of scd4x_get_serial_number has changed
  • removed read_measurement convenience method - see bugfix 1.0.1 where it is added again

0.2.1 - 2021-04-30

Changed

  • Increase timing for single shot from 1350ms to 5000ms
  • Increase timing for self test from 5500ms to 10000ms

0.2.0 - 2021-03-01

Added

  • Convenience interfaces taking care of unit conversion to and from ticks.

Fixed

  • wake-up interface handles missing ACK from sensor on wake up.

0.1.0 - 2021-01-28