Save the current state of the simulator in a scenario file and start recording from now on. Times in recorded file will be relative to the time of the SAVEIC command.
Scenario files are text files with the extension .scn. They contain commands with a [time|Entertime] stamp, e.g:
00:00:00.00>KL204 HDG 270
By default a number of commands are not recorded ([PAN],[ZOOM],[HOLD],[POS],[INSEDIT],[SAVEIC], [QUIT]). With SAVEIC EXCEPT NONE this list is erased (except for bare minimum INSEDIT and SAVEIC).
The [PCALL] command is also not recorded itself, but all commands from the called file(s) will be recorded as well
Usage:
SAVEIC filename
SAVEIC CLOSE
SAVEIC EXCEPT command command command ...
SAVEIC EXCEPT NONE
SAVEIC EXCEPT
Arguments:
Name | Type | Required | Description |
---|---|---|---|
filename | string | no | Name of the scenario file (default location: scenario folder, extension .scn will be added) |
CLOSE | string | no | keyword to close current file and stop recording (automatically called during reset or quit |
EXCEPT | string | no | keyword to select which commands to excluded (or show current list) |
command | string | no | command to be excluded |