1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*u,
*r,
*w,
u,Broadcast,,Datetime,Datum Uhrzeit,,fe,0700,,outsidetemp,,D2B,,°C,Temperatur,time,,BTI,,,Uhrzeit,date,,BDA,,,Datum
r,Broadcast,,Id,Identifikation,,,0704,,mf,,UCH,6=Dungs;15=FH Ostfalia;16=TEM;17=Lamberti;20=CEB;21=Landis-Staefa;22=FERRO;23=MONDIAL;24=Wikon;25=Wolf;32=RAWE;48=Satronic;64=ENCON;80=Kromschröder;96=Eberle;101=EBV;117=Grässlin;133=ebm-papst;149=SIG;165=Theben;167=Thermowatt;181=Vaillant;192=Toby;197=Weishaupt;253=ebusd.eu;253=ebusd,,Geräte-Hersteller,id,,STR:5,,,Geräte-ID,sw,,PIN,,,Software-Version,hw,,PIN,,,Hardware-Version
w,Broadcast,,IdQuery,query identification,,fe,0704,,
u,Broadcast,,IdAnswer,answer to identification query,,fe,0704,,mf,,UCH,6=Dungs;15=FH Ostfalia;16=TEM;17=Lamberti;20=CEB;21=Landis-Staefa;22=FERRO;23=MONDIAL;24=Wikon;25=Wolf;32=RAWE;48=Satronic;64=ENCON;80=Kromschröder;96=Eberle;101=EBV;117=Grässlin;133=ebm-papst;149=SIG;165=Theben;167=Thermowatt;181=Vaillant;192=Toby;197=Weishaupt;253=ebusd.eu;253=ebusd,,Geräte-Hersteller,id,,STR:5,,,Geräte-ID,sw,,PIN,,,Software-Version,hw,,PIN,,,Hardware-Version
w,Broadcast,,Queryexistence,Existenzanfrage,,fe,07fe,,
u,Broadcast,,Signoflife,Lebenszeichen,,fe,07ff,,
u,Broadcast,,Error,Fehlernachricht,,fe,fe01,,error,,STR:10,,,
u,Broadcast,,RcTarget,room controller target values,,fe,0800,,desiredtemp,,D2B,,°C,boiler target temperature,outsidetemp,,D2B,,°C,Außentemperatur,forced,,SCH,,%,forced performance,hwc,,BI0,,,hot water active,hc,,BI1,,,heat active,hwcdesiredtemp,,D2B,,°C,hot water target temperature
u,Broadcast,,RcOperation,room controller operational data,,fe,0801,,temp,,D2B,,°C,boiler effective temperature,buffertemp,,D2B,,°C,hot water effective temperature,emissiontest,,UCH,0=none;1=br1;2=br1stb;3=br12;4=br12stb,,emission test,hwc,,BI0,,,hot water active,pump,,BI1,,,pump active,buffer1,,BI2,,,buffer 1 active,buffer2,,BI3,,,buffer 2 active,loading,,BI4,,,loading pump active,hwcloading,,BI5,,,hot water loading pump active,tbfconnect,,BI6,,,TBF connected,returntemp,,D2B,,°C,return flow temperature
u,Broadcast,,ControlCmd,control commands,,fe,0802,,desiredtemp,,D2B,,°C,boiler target temperature,hwcdesiredtemp,,D2B,,°C,hot water target temperature,expected,,SCH,,%,expected performance,device,,UCH,,,first device with error,error,,UCH,,,error code
u,Broadcast,,Netresetstate,reset network state,,fe,ff00,,
u,Broadcast,,Netresetcfg,reset network config,,fe,ff01,,
u,Broadcast,,Netloss,network loss,,fe,ff02,,