Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.370.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
146 lines (146 loc) · 22.6 KB
/
15.370.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,ActualWeekday,Aktueller Wochentag,,,b509,0d5f00,value,,BDY,,,Wochentag
r,,,Date,Aktuelles Datum,,,b509,0d6100,value,,HDA:3,,,Datum
w,,,Date,Aktuelles Datum,,,b509,0e6100,value,,HDA:3,,,Datum
r,,,Time,Aktuelle Uhrzeit,,,b509,0d6000,value,,VTI,,,Uhrzeit
w,,,Time,Aktuelle Uhrzeit,,,b509,0e6000,value,,VTI,,,Uhrzeit
r,,,RoomTemp,Raumisttemp: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,RoomTempCorrection,Raumtemperatur-Abgleich: Korrekturwert der Raumtemperaturanzeige,,,b509,0d5700,value,,SCH,2,K,
w,,,RoomTempCorrection,Raumtemperatur-Abgleich: Korrekturwert der Raumtemperaturanzeige,,,b509,0e5700,value,,SCH,2,K,
r,,,DisplayedHc1RoomTempDesired,"Angezeigte Raumtemperatur Soll Heizkreis 1: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,Temperatur
r,,,Hc1OPMode,Betriebsart Heizkreis 1,,,b509,0d2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
w,,,Hc1OPMode,Betriebsart Heizkreis 1,,,b509,0e2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
r,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0d2700,value,,D1C,,°C,Temperatur
w,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0e2700,value,,D1C,,°C,Temperatur
r,,,Hc1NightTemp,Absenktemperatur Heizkreis 1: Absenktemperatur des 1. Heizkreises,,,b509,0d3000,value,,D1C,,°C,Temperatur
w,,,Hc1NightTemp,Absenktemperatur Heizkreis 1: Absenktemperatur des 1. Heizkreises,,,b509,0e3000,value,,D1C,,°C,Temperatur
r,,,Hc1QuickVetoTemp,Quick Veto Temperatur Heizkreis 1: manual override setpoint of the first heating circuit,,,b509,0d3c00,value,,D1C,,°C,Temperatur
r,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,Hc1SFMode,HC1_SFMode,,,b509,0d5d00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of first heating circuit
r,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0d1100,value,,HDA:3,,,Datum
w,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0e1100,value,,HDA:3,,,Datum
r,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0d1200,value,,HDA:3,,,Datum
w,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0e1200,value,,HDA:3,,,Datum
r,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0d2100,value,,HDA:3,,,Datum
w,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0e2100,value,,HDA:3,,,Datum
r,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0d2200,value,,HDA:3,,,Datum
w,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0e2200,value,,HDA:3,,,Datum
r,,,HwcTempDesired,gewünschte Temperatur Warmwasserkreis: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,Temperatur
w,,,HwcTempDesired,gewünschte Temperatur Warmwasserkreis: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,Temperatur
r,,,HcName1,"Heizkreisname HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0d3f00,value,,STR:11,,,Name des Heizkreises
w,,,HcName1,"Heizkreisname HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0e3f00,value,,STR:11,,,Name des Heizkreises
r,,,ContactName,aucContactName,,,b509,0db400,value,,STR:13,,,"Fachhandwerker Name (nur A-Z,0-9 und Leerzeichen)"
w,,install,ContactName,aucContactName,,,b509,0eb400,value,,STR:13,,,"Fachhandwerker Name (nur A-Z,0-9 und Leerzeichen)"
r,,,PhoneNumber,Telefonnummer Fachhandwerker,,,b509,0d5400,value,,STR:13,,,"Fachhandwerker Telefonnummer (nur 0-9,- und Leerzeichen)"
w,,install,PhoneNumber,Telefonnummer Fachhandwerker,,,b509,0e5400,value,,STR:13,,,"Fachhandwerker Telefonnummer (nur 0-9,- und Leerzeichen)"
r,,,MaintenanceDate,Datum nächste Wartung,,,b509,0d5900,value,,HDA:3,,,Datum
w,,install,MaintenanceDate,Datum nächste Wartung,,,b509,0e5900,value,,HDA:3,,,Datum
r,,,LcdContrastValue,Display Kontrastwert: Einstellung des LCD-Kontrasts,,,b509,0d5a00,value,,UCH,,,
w,,,LcdContrastValue,Display Kontrastwert: Einstellung des LCD-Kontrasts,,,b509,0e5a00,value,,UCH,,,
r,,,SummerWinterTimeAdjust,Sommer/Winterzeit Umstellung,,,b509,0d5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
w,,,SummerWinterTimeAdjust,Sommer/Winterzeit Umstellung,,,b509,0e5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
r,,,LanguageVariant,Sprachvariante,,,b509,0d1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
w,,,LanguageVariant,Sprachvariante,,,b509,0e1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
r,,,BMUFlowTempOrVF1,Vorlauftemperaturfühler 1: value of either an externally connected flow temperature sensor or the BMU's internal flow sensor if an external sensor is missing,,,b509,0d8700,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,Temperatur
r,,,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0d3600,value,,UCH,0=two_point_control;1=analogue_control,,Zweipunktregelung
w,,install,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0e3600,value,,UCH,0=two_point_control;1=analogue_control,,Zweipunktregelung
r,,,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: Abgleich Regelstrecke,,,b509,0d3700,value,,SCH,,,
w,,install,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: Abgleich Regelstrecke,,,b509,0e3700,value,,SCH,,,
r,,,CirPump,Zirkulationspumpe aktiv: circulation pump's state,,,b509,0d8100,value,,UCH,0=no;1=yes,,
r,,,Hc1ActualFlowTempDesired,Aktuelle Vorlauftemperatur Soll Heizkreis 1: current flow temperature setpoint of the first heating circuit,,,b509,0d3e00,value,,D1C,,°C,Temperatur
r,,,HwcCircuitActive,Warmwasserkreis aktiv: Warmwasserkreis ist eingeschaltet,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,Warmwasserkreis aktiv: Warmwasserkreis ist eingeschaltet,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,HwcLegioStartDay,Start Legionellenschutz Warmwasserkreis,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,Wochentag an dem die Legionellenschutzfunktion gestartet wird (evt. auch täglich)
w,,install,HwcLegioStartDay,Start Legionellenschutz Warmwasserkreis,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,Wochentag an dem die Legionellenschutzfunktion gestartet wird (evt. auch täglich)
r,,,HwcLegioStartTime,Startzeit Legionellenschutz Warmwasserkreis: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,Uhrzeit
w,,install,HwcLegioStartTime,Startzeit Legionellenschutz Warmwasserkreis: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,Uhrzeit
r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature (also in case of an SP1error),,,b509,0d9e00,value,,D1C,,°C,Temperatur
r,,,HwcActualTempDesired,Aktuelle Temperatur Soll Warmwasserkreis: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,Temperatur
r,,,KeyCodeforConfigMenu,Passwort für das Konfigurationsmenü: code for the installer's menues,,,b509,0d5500,value,,PIN,,,
w,,install,KeyCodeforConfigMenu,Passwort für das Konfigurationsmenü: code for the installer's menues,,,b509,0e5500,value,,PIN,,,
r,,,GlobalSystemOff,"GlobalSystemOFF: Set to TRUE if ""System Off"" is selected",,,b509,0d0100,value,,UCH,0=off;1=on,,
r,,,StatusDcf,Status DCF,,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=validDCF;4=validRTC,,Status DCF Signal
r,,,DcfIsValid,DcfIsValid: validity of DCF signal,,,b509,0d0400,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,HydraulicMap,"HydraulicMap: hydraulic map (0 = H1, 3 = H4, 11 = A1, 12 = A2, 14 = A5, 15 = S1, 16 = S3a, 17 = S3b)",,,b509,0d1800,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,Raumsolltemp. HK1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,Temperatur
r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
r,,,B51000M8HeatFlowSetMonitor,B51000M8HeatFlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,,
r,,,B51000M9TappingSetMon,B51000M9TappingSetMon: DHW setpoint without loading offset (for hydraulic map H1),,,b509,0d5600,value,,D1C,,,
r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (left bit 0, right bit 7)",,,b509,0d6700,value,,UCH,,,
r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (left bit 0, right bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
r,,,TestVarActivateFunction,TestVarActivateFunction: 0=All SF_OFF11/2=1DayHolON/OFF13/4=1DayBankON/OFF19/10=1xDHWLoadON/OFF11/12=QVetoON/OFF115/16=PartyON/OFF119/20=Ventil.ON/OFF123/24=SystemOff_ON/OFF,,,b509,0d0b00,value,,UCH,,,
r,,,HwcOPMode,"Betriebsart Warmwasserkreis: operation mode of the domestic hot water circuit set implicitly (0 = off, 1 = on, 2 = auto, 3 = auto sunday, 4 = party, 6 = one time tank loading, 7 = holiday)",,,b509,0d4200,value,,UCH,,,
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,,,
r,,,B51000TempDesiredLoadingPump,B51000SetPointLoadingPump: loading pump's setpoint sent via B5 10 00 to the BMU,,,b509,0d7b00,value,,D1C,,,
r,,,BMUB51101BoilerFlowTemp,BMUB51101_BoilerFlowTemp: Gemessene Vorlauftemperatur am internen Sensor,,,b509,0d7700,value,,D1C,,°C,Temperatur
r,,,BMUB51101StorageTemp,Speichertemperatur Ist: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,Temperatur
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,StartEepromUpdate,Starte EEPROM Aktualsiserung: update of the EEPROM has to be started,,,b509,0d0e00,value,,UCH,0=no;1=yes,,
r,,,EepromUpdateActive,EEPROM Aktivierung aktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=no;1=yes,,
r,,,ChimneySweepModeActive,Schornsteinfegerbetrieb: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,HwcLoadingIn430Active,DHWLoadingIn430Active: DHW-loading is active in non parallel loading cases,,,b509,0d9300,value,,UCH,0=no;1=yes,,
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,InstallAssistant,"InstallAssistant: install assistant not active (0 = active, 1 = not active)",,,b509,0d5e00,value,,UCH,0=off;1=on,,
r,,,FactoryTestActive,Fertigungstest aktiv: Factory Test Pin,,,b509,0d1000,value,,UCH,0=no;1=yes,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,PumpEnergySaveStateMonitor,PumpEnergySaveStateMonitor: monitoring of the pump energy saving's state transition diagram,,,b509,0d9100,value,,UCH,,,
r,,,PumpEnergySaveCalculatedTimeMonitor,PumpEnergySaveCalculatedTimeMonitor: calculated time for the heating circuit's pump's switch off time during pump energy saving function (depends on outside temperature),,,b509,0d9200,value,,UCH,,min,Minuten
r,,,ActoSTOROPMode,actoSTOR_OPMode: state diagram actoSTOR control,,,b509,0d9400,value,,UCH,,,
r,,,ClockSwitchSummerWinterDone,Umschaltung Sommer-Winterzeit erfolgt: automatic switching over to/from daylight saving's time has been done,,,b509,0d7800,value,,UCH,0=no;1=yes,,
r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
r,,,MonitorCurrentIPart,MonitorCurrent_I_Anteil: current i-control value; updated every 3 minutes,,,b509,0d3300,value,,D2C,,°C,Temperatur
r,,,CountryVariant,"Ländervariante: country variant (0 = west, 1 = east, 2 = all)",,,b509,0d1700,value,,UCH,,,
r,,,DisplayedRoomTemp,Raumtemperatur Ist: Aktuelle Raumtemperatur,,,b509,0d8000,value,,D2C,,°C,Temperatur
r,,,RaumtempIstUnten,RaumtempIstUnten: lower room temp sensor value,,,b509,0dc100,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,ADCValueTempbelow,ADCValue_T_below: lower room temp sensor ADC value,,,b509,0d4e00,value,,UIN,,,
r,,,CcTimer_Monday,Zeitfenster Montag,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Monday,Zeitfenster Montag,,,b515,0002,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0102,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0202,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0302,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Friday,Zeitfenster Freitag,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Friday,Zeitfenster Freitag,,,b515,0402,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Saturday,Zeitfenster Samstag,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Saturday,Zeitfenster Samstag,,,b515,0502,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Sunday,Zeitfenster Montag,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Sunday,Zeitfenster Montag,,,b515,0602,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Monday,Zeitfenster Montag,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Monday,Zeitfenster Montag,,,b515,0001,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0101,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0201,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0301,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Friday,Zeitfenster Freitag,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Friday,Zeitfenster Freitag,,,b515,0401,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Saturday,Zeitfenster Samstag,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Saturday,Zeitfenster Samstag,,,b515,0501,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Sunday,Zeitfenster Montag,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Sunday,Zeitfenster Montag,,,b515,0601,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Monday,Zeitfenster Montag,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Monday,Zeitfenster Montag,,,b515,0000,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0100,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0200,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0300,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Friday,Zeitfenster Freitag,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Friday,Zeitfenster Freitag,,,b515,0400,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Saturday,Zeitfenster Samstag,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Saturday,Zeitfenster Samstag,,,b515,0500,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Sunday,Zeitfenster Montag,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Sunday,Zeitfenster Montag,,,b515,0600,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Currenterror,Aktuelle Fehler,,,b503,0001,error,,UIN,,,Fehlernummer,error_1,,UIN,,,Fehlernummer,error_2,,UIN,,,Fehlernummer,error_3,,UIN,,,Fehlernummer,error_4,,UIN,,,Fehlernummer
r,,,Errorhistory,Fehlerhistorie,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,Uhrzeit,date,,HDA:3,,,Datum,error,,UIN,,,Fehlernummer
w,,install,Clearerrorhistory,Fehlerhistorie löschen,,,b503,0201,cleared,s,UCH,0=no;1=yes,,