-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.f47.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
224 lines (224 loc) · 35.2 KB
/
15.f47.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,ActualWeekday,Aktueller Wochentag,,,b509,0d5f00,value,,BDY,,,Wochentag
r,,,Date,Aktuelles Datum,,,b509,0d6100,value,,HDA:3,,,Datum
w,,,Date,Aktuelles Datum,,,b509,0e6100,value,,HDA:3,,,Datum
r,,,Time,Aktuelle Uhrzeit,,,b509,0d6000,value,,VTI,,,Uhrzeit
w,,,Time,Aktuelle Uhrzeit,,,b509,0e6000,value,,VTI,,,Uhrzeit
r,,,RoomTemp,Raumisttemp: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,RoomTempCorrection,Raumtemperatur-Abgleich: Korrekturwert der Raumtemperaturanzeige,,,b509,0d5700,value,,SCH,2,K,
w,,,RoomTempCorrection,Raumtemperatur-Abgleich: Korrekturwert der Raumtemperaturanzeige,,,b509,0e5700,value,,SCH,2,K,
r,,,OutsideTemp,Außentemp. Sensor: Außentemperatur und Sensorstatus,,,b509,0d6200,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,OutsideTempOffset,Außentemperatur-Abgleich: Korrekturwert für die Außentemperatur,,,b509,0d5800,value,,SCH,2,K,
w,,,OutsideTempOffset,Außentemperatur-Abgleich: Korrekturwert für die Außentemperatur,,,b509,0e5800,value,,SCH,2,K,
r,,,DisplayedHc1RoomTempDesired,"Angezeigte Raumtemperatur Soll Heizkreis 1: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,Temperatur
r,,,Hc1OPMode,Betriebsart Heizkreis 1,,,b509,0d2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
w,,,Hc1OPMode,Betriebsart Heizkreis 1,,,b509,0e2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
r,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0d2700,value,,D1C,,°C,Temperatur
w,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0e2700,value,,D1C,,°C,Temperatur
r,,,Hc1NightTemp,Absenktemperatur Heizkreis 1: Absenktemperatur des 1. Heizkreises,,,b509,0d3000,value,,D1C,,°C,Temperatur
w,,,Hc1NightTemp,Absenktemperatur Heizkreis 1: Absenktemperatur des 1. Heizkreises,,,b509,0e3000,value,,D1C,,°C,Temperatur
r,,,Hc1QuickVetoTemp,Quick Veto Temperatur Heizkreis 1: manual override setpoint of the first heating circuit,,,b509,0d3c00,value,,D1C,,°C,Temperatur
r,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,Hc1SFMode,HC1_SFMode,,,b509,0d5d00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of first heating circuit
w,,,Hc1SFMode,HC1_SFMode,,,b509,0e5d00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of first heating circuit
r,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0d1100,value,,HDA:3,,,Datum
w,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0e1100,value,,HDA:3,,,Datum
r,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0d1200,value,,HDA:3,,,Datum
w,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0e1200,value,,HDA:3,,,Datum
r,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0d2100,value,,HDA:3,,,Datum
w,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0e2100,value,,HDA:3,,,Datum
r,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0d2200,value,,HDA:3,,,Datum
w,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0e2200,value,,HDA:3,,,Datum
r,,,Hc2HolidayStartPeriod,HC2HolidayStartPeriod: second heating circuit's start date of holidays,,,b509,0d2300,value,,HDA:3,,,Datum
w,,,Hc2HolidayStartPeriod,HC2HolidayStartPeriod: second heating circuit's start date of holidays,,,b509,0e2300,value,,HDA:3,,,Datum
r,,,Hc2HolidayEndPeriod,HC2HolidayEndPeriod: second heating circuit's end date of holidays,,,b509,0d2400,value,,HDA:3,,,Datum
w,,,Hc2HolidayEndPeriod,HC2HolidayEndPeriod: second heating circuit's end date of holidays,,,b509,0e2400,value,,HDA:3,,,Datum
r,,,Hc2BankHolidayStartPeriod,HC2BankHolidayStartPeriod: second heating circuit's start date of bank holidays,,,b509,0d2500,value,,HDA:3,,,Datum
w,,,Hc2BankHolidayStartPeriod,HC2BankHolidayStartPeriod: second heating circuit's start date of bank holidays,,,b509,0e2500,value,,HDA:3,,,Datum
r,,,Hc2BankHolidayEndPeriod,HC2BankHolidayEndPeriod: second heating circuit's end date of bank holidays,,,b509,0d2600,value,,HDA:3,,,Datum
w,,,Hc2BankHolidayEndPeriod,HC2BankHolidayEndPeriod: second heating circuit's end date of bank holidays,,,b509,0e2600,value,,HDA:3,,,Datum
r,,,Hc2SFMode,HC2_SFMode,,,b509,0d1c00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of second heating circuit
w,,,Hc2SFMode,HC2_SFMode,,,b509,0e1c00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of second heating circuit
r,,,HwcTempDesired,gewünschte Temperatur Warmwasserkreis: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,Temperatur
w,,,HwcTempDesired,gewünschte Temperatur Warmwasserkreis: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,Temperatur
r,,,HcName1,"Heizkreisname HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0d3f00,value,,STR:11,,,Name des Heizkreises
w,,,HcName1,"Heizkreisname HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0e3f00,value,,STR:11,,,Name des Heizkreises
r,,,HcName2,"Heizkreisname HK2: labelling of the second heating circuit (only A-Z,0-9,blank)",,,b509,0d3f08,value,,STR:11,,,Name des Heizkreises
w,,,HcName2,"Heizkreisname HK2: labelling of the second heating circuit (only A-Z,0-9,blank)",,,b509,0e3f08,value,,STR:11,,,Name des Heizkreises
r,,,ContactName,aucContactName,,,b509,0db400,value,,STR:13,,,"Fachhandwerker Name (nur A-Z,0-9 und Leerzeichen)"
w,,install,ContactName,aucContactName,,,b509,0eb400,value,,STR:13,,,"Fachhandwerker Name (nur A-Z,0-9 und Leerzeichen)"
r,,,PhoneNumber,Telefonnummer Fachhandwerker,,,b509,0d5400,value,,STR:13,,,"Fachhandwerker Telefonnummer (nur 0-9,- und Leerzeichen)"
w,,install,PhoneNumber,Telefonnummer Fachhandwerker,,,b509,0e5400,value,,STR:13,,,"Fachhandwerker Telefonnummer (nur 0-9,- und Leerzeichen)"
r,,,MaintenanceDate,Datum nächste Wartung,,,b509,0d5900,value,,HDA:3,,,Datum
w,,install,MaintenanceDate,Datum nächste Wartung,,,b509,0e5900,value,,HDA:3,,,Datum
r,,,LcdContrastValue,Display Kontrastwert: Einstellung des LCD-Kontrasts,,,b509,0d5a00,value,,UCH,,,
w,,,LcdContrastValue,Display Kontrastwert: Einstellung des LCD-Kontrasts,,,b509,0e5a00,value,,UCH,,,
r,,,SummerWinterTimeAdjust,Sommer/Winterzeit Umstellung,,,b509,0d5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
w,,,SummerWinterTimeAdjust,Sommer/Winterzeit Umstellung,,,b509,0e5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
r,,,LanguageVariant,Sprachvariante,,,b509,0d1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
w,,,LanguageVariant,Sprachvariante,,,b509,0e1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
r,,,BMUFlowTempOrVF1,Vorlauftemperaturfühler 1: value of either an externally connected flow temperature sensor or the BMU's internal flow sensor if an external sensor is missing,,,b509,0d8700,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,Temperatur
r,,,OpModeEffect,OpModeEffect,,,b509,0db800,value,,UCH,0=HC1;1=HC2;3=HC1_HC2,,selection which heating circuit is affected by changing parameters in the basic display
w,,install,OpModeEffect,OpModeEffect,,,b509,0eb800,value,,UCH,0=HC1;1=HC2;3=HC1_HC2,,selection which heating circuit is affected by changing parameters in the basic display
r,,,HydraulicSwitch,HydraulicSwitch: hydraulic switch is installed,,,b509,0db700,value,,UCH,0=no;1=yes,,
w,,install,HydraulicSwitch,HydraulicSwitch: hydraulic switch is installed,,,b509,0eb700,value,,UCH,0=no;1=yes,,
r,,,HcMc1ConfigCPLP,BKMK1ConfigCPLP,,,b509,0d7d00,value,,UCH,0=off;1=CP;2=LP,,Konfuguration VR61 Relaisausgang
w,,install,HcMc1ConfigCPLP,BKMK1ConfigCPLP,,,b509,0e7d00,value,,UCH,0=off;1=CP;2=LP,,Konfuguration VR61 Relaisausgang
r,,,CirPump,Zirkulationspumpe aktiv: circulation pump's state,,,b509,0d8100,value,,UCH,0=no;1=yes,,
r,,,Hc1HcType,Typ Heizkreis 1,,,b509,0d3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
w,,install,Hc1HcType,Typ Heizkreis 1,,,b509,0e3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
r,,,Hc1HeatCurve,Heizkurve Heizkreis 1: heating curve of the first heating circuit,,,b509,0d3100,value,,UIN,100,,Heizkurve: Heating curve
w,,install,Hc1HeatCurve,Heizkurve Heizkreis 1: heating curve of the first heating circuit,,,b509,0e3100,value,,UIN,100,,Heizkurve: Heating curve
r,,,Hc1RoomTempSwitchOn,Raumtemperaturschalter Heizkreis 1,,,b509,0d3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
w,,install,Hc1RoomTempSwitchOn,Raumtemperaturschalter Heizkreis 1,,,b509,0e3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
r,,,Hc1SummerOffset,"Sommer-Abgleich Heizkreis 1: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0d3b00,value,,SCH,2,K,
w,,install,Hc1SummerOffset,"Sommer-Abgleich Heizkreis 1: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0e3b00,value,,SCH,2,K,
r,,,Hc1MinimalFlowTempDesired,Minimale Vorlauftemperatur Soll Heizkreis 1: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0d3500,value,,D1C,,°C,Temperatur
w,,install,Hc1MinimalFlowTempDesired,Minimale Vorlauftemperatur Soll Heizkreis 1: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0e3500,value,,D1C,,°C,Temperatur
r,,,Hc1AutoOffMode,HC1_AutoOFF_Mode,,,b509,0d4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
w,,install,Hc1AutoOffMode,HC1_AutoOFF_Mode,,,b509,0e4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
r,,,Hc1ActualFlowTempDesired,Aktuelle Vorlauftemperatur Soll Heizkreis 1: current flow temperature setpoint of the first heating circuit,,,b509,0d3e00,value,,D1C,,°C,Temperatur
r,,,Hc1FloorPavementDryingTemp,HC1_FloorPavementDryingTemperature: HC1's current flow temperature setpoint with activated floor pavement drying,,,b509,0d2a00,value,,D1C,,°C,Temperatur
r,,,Hc1FloorPavementDryingDay,HC1_FloorPavementDryingDay: HC1's current day of floor pavement drying,,,b509,0d3800,value,,UCH,,,
w,,install,Hc1FloorPavementDryingDay,HC1_FloorPavementDryingDay: HC1's current day of floor pavement drying,,,b509,0e3800,value,,UCH,,,
r,,,Hc2HcType,Typ Heizkreis 2,,,b509,0d8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
w,,install,Hc2HcType,Typ Heizkreis 2,,,b509,0e8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
r,,,HwcCircuitActive,Warmwasserkreis aktiv: Warmwasserkreis ist eingeschaltet,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,Warmwasserkreis aktiv: Warmwasserkreis ist eingeschaltet,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,HwcParallelLoading,Parallele Ladung Warmwasserkreis: Heizbetrieb und Speicherladung parallel,,,b509,0d4800,value,,UCH,0=off;1=on,,
r,,,HwcLoadingOffset,Speicherlade-Abgleich Warmwasserkreis: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0d4600,value,,D1C,,K,
w,,install,HwcLoadingOffset,Speicherlade-Abgleich Warmwasserkreis: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0e4600,value,,D1C,,K,
r,,,HwcPressLowpostrunningtime,Vorlaufzeit Speicherladung Warmwasserkreis: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0d4700,value,,UCH,,min,Minuten
w,,install,HwcPressLowpostrunningtime,Vorlaufzeit Speicherladung Warmwasserkreis: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0e4700,value,,UCH,,min,Minuten
r,,,HwcLegioStartDay,Start Legionellenschutz Warmwasserkreis,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,Wochentag an dem die Legionellenschutzfunktion gestartet wird (evt. auch täglich)
w,,install,HwcLegioStartDay,Start Legionellenschutz Warmwasserkreis,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,Wochentag an dem die Legionellenschutzfunktion gestartet wird (evt. auch täglich)
r,,,HwcLegioStartTime,Startzeit Legionellenschutz Warmwasserkreis: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,Uhrzeit
w,,install,HwcLegioStartTime,Startzeit Legionellenschutz Warmwasserkreis: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,Uhrzeit
r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature (also in case of an SP1error),,,b509,0d9e00,value,,D1C,,°C,Temperatur
r,,,HwcActualTempDesired,Aktuelle Temperatur Soll Warmwasserkreis: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,Temperatur
r,,,FrostOverRideTime,Frostschutz-Verzögerung: delay before frost protection is activated,,,b509,0d1a00,value,,UCH,,h,Stunden
w,,install,FrostOverRideTime,Frostschutz-Verzögerung: delay before frost protection is activated,,,b509,0e1a00,value,,UCH,,h,Stunden
r,,,ContinuosHeating,"Durchgehendes Heizen: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0d4f00,value,,SCH,,,
w,,install,ContinuosHeating,"Durchgehendes Heizen: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0e4f00,value,,SCH,,,
r,,,PreheatingTime,"Vorheizzeit: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0d5000,value,,UIN,,,
w,,install,PreheatingTime,"Vorheizzeit: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0e5000,value,,UIN,,,
r,,,PreStopTime,"Vorabsenkzeit: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0d5100,value,,UCH,,,
w,,install,PreStopTime,"Vorabsenkzeit: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0e5100,value,,UCH,,,
r,,,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0d5200,value,,D1C,,K,
w,,install,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0e5200,value,,D1C,,K,
r,,,PumpBlockingTimeMax,"Maximale Pumpen Sperrzeit: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function (0 <=> Off; value range only 5-60 min)",,,b509,0d7e00,value,,UCH,,,
w,,install,PumpBlockingTimeMax,"Maximale Pumpen Sperrzeit: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function (0 <=> Off; value range only 5-60 min)",,,b509,0e7e00,value,,UCH,,,
r,,,KeyCodeforConfigMenu,Passwort für das Konfigurationsmenü: code for the installer's menues,,,b509,0d5500,value,,PIN,,,
w,,install,KeyCodeforConfigMenu,Passwort für das Konfigurationsmenü: code for the installer's menues,,,b509,0e5500,value,,PIN,,,
r,,,GlobalSystemOff,"GlobalSystemOFF: Set to TRUE if ""System Off"" is selected",,,b509,0d0100,value,,UCH,0=off;1=on,,
r,,,StatusDcf,Status DCF,,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=validDCF;4=validRTC,,Status DCF Signal
r,,,DcfIsValid,DcfIsValid: validity of DCF signal,,,b509,0d0400,value,,UCH,0=no;1=yes,,
r,,,HcMc1Detected,BKMK1Detected: indicates that a VR61 has been detected,,,b509,0d6d00,value,,UCH,0=no;1=yes,,
r,,,SolModuleDetected,Solarmodul erkannt: indicates that a VR68 has been detected,,,b509,0d6c00,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,VR81Detected,VR81Detected: indicates that a VR81 has been detected,,,b509,0d7400,value,,UCH,0=no;1=yes,,
r,,,ASCDetected,ASCDetected: indicates that a VMS has been detected,,,b509,0dbb00,value,,UCH,0=no;1=yes,,
r,,,VF1,VF_1: Gemessene Vorlauftemperatur am externen Vorlaufsensor,,,b509,0d7600,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,HydraulicMap,"HydraulicMap: hydraulic map (0 = H1, 3 = H4, 11 = A1, 12 = A2, 14 = A5, 15 = S1, 16 = S3a, 17 = S3b)",,,b509,0d1800,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,Raumsolltemp. HK1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,Temperatur
r,,,Hc2OPMode,HC2_OPMode,,,b509,0d1b00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the second heating circuit
r,,,Hc2TempDesiredB50418,HC2_Desired_TempB50418: current flow temperature setpoint of the second heating circuit,,,b509,0d3200,value,,D1C,,°C,Temperatur
r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
r,,,B51000M8HeatFlowSetMonitor,B51000M8HeatFlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,,
r,,,B51000M9TappingSetMon,B51000M9TappingSetMon: DHW setpoint without loading offset (for hydraulic map H1),,,b509,0d5600,value,,D1C,,,
r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (left bit 0, right bit 7)",,,b509,0d6700,value,,UCH,,,
r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (left bit 0, right bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
r,,,TestVarActivateFunction,TestVarActivateFunction: 0=All SF_OFF11/2=1DayHolON/OFF13/4=1DayBankON/OFF15/6=1DayHolON/OFF27/8=1DayBankON/OFF29/10=1xDHWLoadON/OFF11/12=QVetoON/OFF113/14=QVetoON/OFF215/16=PartyON/OFF117/18=PartyON/OFF219/20=Ventil.ON/OFF121/22=Ventil.ON/OFF223/24=SystemOff_ON/OFF,,,b509,0d0b00,value,,UCH,,,
r,,,HwcOPMode,"Betriebsart Warmwasserkreis: operation mode of the domestic hot water circuit set implicitly (0 = off, 1 = on, 2 = auto, 3 = auto sunday, 4 = party, 6 = one time tank loading, 7 = holiday)",,,b509,0d4200,value,,UCH,,,
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,,,
r,,,B51000TempDesiredLoadingPump,B51000SetPointLoadingPump: loading pump's setpoint sent via B5 10 00 to the BMU,,,b509,0d7b00,value,,D1C,,,
r,,,BMUB51101BoilerFlowTemp,BMUB51101_BoilerFlowTemp: Gemessene Vorlauftemperatur am internen Sensor,,,b509,0d7700,value,,D1C,,°C,Temperatur
r,,,BMUB51101StorageTemp,Speichertemperatur Ist: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,Temperatur
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,StartEepromUpdate,Starte EEPROM Aktualsiserung: update of the EEPROM has to be started,,,b509,0d0e00,value,,UCH,0=off;1=on,,
r,,,EepromUpdateActive,EEPROM Aktivierung aktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=off;1=on,,
r,,,Hc1PreOrContinuosHeatingActive,HC1PreOrContinuosHeatingActive: preheating or continous heating is active for the first heating circuit,,,b509,0d8b00,value,,UCH,0=no;1=yes,,
r,,,Hc1PreCutOffActive,HC1_PreCutOffActive: early cut off is active for the first heating circuit,,,b509,0d4100,value,,UCH,0=no;1=yes,,
r,,,Hc2HolidayPeriodIsActive,HC2HolidayPeriodIsActive: calculated by 470 and sent to VR61,,,b509,0d0c00,value,,UCH,0=no;1=yes,,
r,,,Hc2BankHolidayPeriodIsActive,HC2BankHolidayPeriodIsActive: calculated by 470 and sent to VR61,,,b509,0d0d00,value,,UCH,0=no;1=yes,,
r,,,ChimneySweepModeActive,Schornsteinfegerbetrieb: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,HwcLoadingIn430Active,DHWLoadingIn430Active: DHW-loading is active in non parallel loading cases,,,b509,0d9300,value,,UCH,0=no;1=yes,,
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,V430PluggedIn,V430_PluggedIn: false if calorMATIC 470 is set inside a wall socket and not plugged in,,,b509,0db300,value,,UCH,0=no;1=yes,,
r,,,InstallAssistant,"InstallAssistant: install assistant not active (0 = active, 1 = not active)",,,b509,0d5e00,value,,UCH,0=off;1=on,,
r,,,VR81ActiveForHc1,VR81ActiveForHC1: VR81 is connected to the first heating circuit,,,b509,0d5c00,value,,UCH,0=no;1=yes,,
r,,,VR81ActiveForHc2,VR81ActiveForHC2: VR81 is connected to the second heating circuit,,,b509,0da700,value,,UCH,0=no;1=yes,,
r,,,FactoryTestActive,Fertigungstest aktiv: Factory Test Pin,,,b509,0d1000,value,,UCH,0=no;1=yes,,
r,,,HcMc1CPLPState,BKMK1CPLPState: nominal condition of the VR61's circulation or loading pump,,,b509,0d7f00,value,,UCH,0=off;1=on,,
r,,,EnermanState,"EnermanState: current energy-manager-state (0 = off, 1 = heating, 2 = DHW, 3 = DHW pump lag)",,,b509,0d7a00,value,,UCH,,,
r,,,Hc1Pump,Pumpe Heizkreis 1 aktiv: first heating circuit pump's state,,,b509,0d8200,value,,UCH,0=off;1=on,,
r,,,Hc1PumpLast24started,HK1PumpLast24started: first heating circuit's pump has been started during the last 24h,,,b509,0d8400,value,,UCH,0=no;1=yes,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,CalculatedKickStopTime,CalculatedKickStopTime: calculated time in between two pump kicks during frostprotection (time depends on outside temperature),,,b509,0d8c00,value,,UCH,,min,Minuten
r,,,FrostProtectStateMonitor,FrostProtectState_Monitor: monitoring of the frost protection's state transition diagram,,,b509,0d8900,value,,UCH,,,
r,,,FrostProtectionRequiredMonitor,FrostProtectionRequired_Monitor: frost protection should be enabled,,,b509,0d8a00,value,,UCH,0=no;1=yes,,
r,,,FrostProtectDelayMonitor,FrostProtectDelayMonitor: frost protection delay has not elapsed yet,,,b509,0d8f00,value,,UCH,0=no;1=yes,,
r,,,PumpEnergySaveStateMonitor,PumpEnergySaveStateMonitor: monitoring of the pump energy saving's state transition diagram,,,b509,0d9100,value,,UCH,,,
r,,,PumpEnergySaveCalculatedTimeMonitor,PumpEnergySaveCalculatedTimeMonitor: calculated time for the heating circuit's pump's switch off time during pump energy saving function (depends on outside temperature),,,b509,0d9200,value,,UCH,,min,Minuten
r,,,ActoSTOROPMode,actoSTOR_OPMode: state diagram actoSTOR control,,,b509,0d9400,value,,UCH,,,
r,,,ClockSwitchSummerWinterDone,Umschaltung Sommer-Winterzeit erfolgt: automatic switching over to/from daylight saving's time has been done,,,b509,0d7800,value,,UCH,0=no;1=yes,,
r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
r,,,MonitorCurrentIPart,MonitorCurrent_I_Anteil: current i-control value; updated every 3 minutes,,,b509,0d3300,value,,D2C,,°C,Temperatur
r,,,CountryVariant,"Ländervariante: country variant (0 = west, 1 = east, 2 = all)",,,b509,0d1700,value,,UCH,,,
r,,,DisplayedRoomTemp,Raumtemperatur Ist: Aktuelle Raumtemperatur,,,b509,0d8000,value,,D2C,,°C,Temperatur
r,,,RaumtempIstOben,RaumtempIstOben,,,b509,0dc000,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,ADCValueTempabove,ADCValue_T_above,,,b509,0d2d00,value,,UIN,,,
r,,,RaumtempIstUnten,RaumtempIstUnten,,,b509,0dc100,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,ADCValueTempbelow,ADCValue_T_below,,,b509,0d4e00,value,,UIN,,,
r9,,,YieldThisYear,Ertrag dieses Jahr,,,b509,0d3d00:2;0d3d08:2;0d3d10:2;0d3d18:2;0d3d20:2;0d3d28:2;0d3d30:2;0d3d38:2;0d3d40:2;0d3d48:2;0d3d50:2;0d3d58:2,energy,,UIN,,kWh,,energy_1,,UIN,,kWh,,energy_2,,UIN,,kWh,,energy_3,,UIN,,kWh,,energy_4,,UIN,,kWh,,energy_5,,UIN,,kWh,,energy_6,,UIN,,kWh,,energy_7,,UIN,,kWh,,energy_8,,UIN,,kWh,,energy_9,,UIN,,kWh,,energy_10,,UIN,,kWh,,energy_11,,UIN,,kWh,
r,,,YieldLastYear,Ertrag letztes Jahr,,,b509,0d4300:2;0d4308:2;0d4310:2;0d4318:2;0d4320:2;0d4328:2;0d4330:2;0d4338:2;0d4340:2;0d4348:2;0d4350:2;0d4358:2,energy,,UIN,,kWh,,energy_1,,UIN,,kWh,,energy_2,,UIN,,kWh,,energy_3,,UIN,,kWh,,energy_4,,UIN,,kWh,,energy_5,,UIN,,kWh,,energy_6,,UIN,,kWh,,energy_7,,UIN,,kWh,,energy_8,,UIN,,kWh,,energy_9,,UIN,,kWh,,energy_10,,UIN,,kWh,,energy_11,,UIN,,kWh,
r,,,CcTimer_Monday,Zeitfenster Montag,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Monday,Zeitfenster Montag,,,b515,0002,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0102,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0202,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0302,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Friday,Zeitfenster Freitag,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Friday,Zeitfenster Freitag,,,b515,0402,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Saturday,Zeitfenster Samstag,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Saturday,Zeitfenster Samstag,,,b515,0502,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,CcTimer_Sunday,Zeitfenster Montag,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,CcTimer_Sunday,Zeitfenster Montag,,,b515,0602,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Monday,Zeitfenster Montag,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Monday,Zeitfenster Montag,,,b515,0001,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0101,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0201,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0301,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Friday,Zeitfenster Freitag,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Friday,Zeitfenster Freitag,,,b515,0401,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Saturday,Zeitfenster Samstag,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Saturday,Zeitfenster Samstag,,,b515,0501,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HwcTimer_Sunday,Zeitfenster Montag,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HwcTimer_Sunday,Zeitfenster Montag,,,b515,0601,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Monday,Zeitfenster Montag,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Monday,Zeitfenster Montag,,,b515,0000,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Tuesday,Zeitfenster Dienstag,,,b515,0100,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Wednesday,Zeitfenster Mittwoch,,,b515,0200,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Thursday,Zeitfenster Donnerstag,,,b515,0300,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Friday,Zeitfenster Freitag,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Friday,Zeitfenster Freitag,,,b515,0400,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Saturday,Zeitfenster Samstag,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Saturday,Zeitfenster Samstag,,,b515,0500,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,HcTimer_Sunday,Zeitfenster Montag,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,HcTimer_Sunday,Zeitfenster Montag,,,b515,0600,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Currenterror,Aktuelle Fehler,,,b503,0001,error,,UIN,,,Fehlernummer,error_1,,UIN,,,Fehlernummer,error_2,,UIN,,,Fehlernummer,error_3,,UIN,,,Fehlernummer,error_4,,UIN,,,Fehlernummer
r,,,Errorhistory,Fehlerhistorie,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,Uhrzeit,date,,HDA:3,,,Datum,error,,UIN,,,Fehlernummer
w,,install,Clearerrorhistory,Fehlerhistorie löschen,,,b503,0201,cleared,s,UCH,0=no;1=yes,,