type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,StatPowerOn,StatPowerOn,,,b509,0dcc00,value,,UIN,,,
r,,,StatOperatingHours,StatOperatingHours,,,b509,0dcd00,value,,UIN,,,
r,,,StatMonthOfInstallation,StatMonthOfInstallation,,,b509,0dce00,value,,UCH,,,
r,,,StatYearOfInstallation,StatYearOfInstallation,,,b509,0dcf00,value,,UCH,,,
r,,,Stat15MinBusTimeout,Stat15MinBusTimeout,,,b509,0dd000,value,,UCH,,,
r,,,StatRTOSErrorcode,StatRTOSErrorcode,,,b509,0dd100,value,,UIN,,,
r,,,StatRestarts,StatRestarts,,,b509,0dd200,value,,UIN,,,
r,,,StatRTOSErrorCounter,StatRTOSErrorCounter,,,b509,0dd300,value,,UIN,,,
r,,,Storage1Sensor2,Temperature of SP1 sensor,,,b509,0d0000,temp,,D2C,,°C,Temperatur,sensor,,UCH,0=ok;85=circuit;170=cutoff,,Fühlerstatus
r,,,CirPump2,Zirkulationspumpe: State of the circulation pump,,,b509,0d0c00,value,,UCH,0=off;1=on,,
r,,,ThreeWayValveLoadingPump12,State of LP/UV1,,,b509,0d1000,value,,UCH,0=off;1=on,,
r,,,LegioPump2,Legionellenpumpe: State of the legionella pump,,,b509,0d1100,value,,UCH,0=off;1=on,,
r,,,TeleSwitch,State of the Teleswitch,,,b509,0d0a00,value,,UCH,0=off;1=on,,
r,,,OneTimeCirSwitch,1x ZP Schalter: non-recurring circulation pump running period,,,b509,0d0b00,value,,UCH,0=off;1=on,,
r,,,IsInParty,Partyfunktion aktiv: Every bit of this byte represents a heating circuit; if bit is set the party function is activated for the corresponding HC,,,b509,0d4e00,value,,UCH,,,
r,,,HwcLaggingTime2,WP Nachlaufzeit WW: Time pump is running after energy demand is met,,,b509,0d6100,value,,UCH,,min,Minuten
w,,,HwcLaggingTime2,WP Nachlaufzeit WW: Time pump is running after energy demand is met,,,b509,0e6100,value,,UCH,,min,Minuten
r,,,FlowTempDesired2,Vorlaufsolltemperatur: Flow setpoint if tank has an energy demand,,,b509,0d4600,value,,D1C,,°C,Temperatur
r,,,HcParallelStorageFillingEnabled2,HcParallelTankFillingEnabled2: Heating cuircuits can be loaded in parallel to an active tank loading,,,b509,0d5500,value,,UCH,0=no;1=yes,,
w,,,HcParallelStorageFillingEnabled2,HcParallelTankFillingEnabled2: Heating cuircuits can be loaded in parallel to an active tank loading,,,b509,0e5500,value,,UCH,0=no;1=yes,,
r,,,HwcLoadingDelay2,WW Ladeverzögerung: Time waiting for a heating demand in caser of solar gain,,,b509,0d6200,value,,UCH,,min,Minuten
w,,,HwcLoadingDelay2,WW Ladeverzögerung: Time waiting for a heating demand in caser of solar gain,,,b509,0e6200,value,,UCH,,min,Minuten
r,,,SpreadingHwcLoading,Offset Warmwasserladung: Offset for DHW flow temperature,,,b509,0d8800,value,,UCH,,K,
w,,service,SpreadingHwcLoading,Offset Warmwasserladung: Offset for DHW flow temperature,,,b509,0e8800,value,,UCH,,K,
r,,,LegioStartTime2,LegioStartTime2: Hour for legio protection,,,b509,0d8a00,value,,UCH,,,
w,,,LegioStartTime2,LegioStartTime2: Hour for legio protection,,,b509,0e8a00,value,,UCH,,,
r,,,NativeHwcCircuitDisabled,Warmwasserkreis deaktivieren: Disable DHW,,,b509,0da900,value,,UCH,0=no;1=yes,,
w,,install,NativeHwcCircuitDisabled,Warmwasserkreis deaktivieren: Disable DHW,,,b509,0ea900,value,,UCH,0=no;1=yes,,
r,,,NormalHwcHysteresis,Hysterese Warmwasserladung: The hysteresis for DHW loading,,,b509,0daf00,value,,UCH,,K,
w,,,NormalHwcHysteresis,Hysterese Warmwasserladung: The hysteresis for DHW loading,,,b509,0eaf00,value,,UCH,,K,
r,,,OperatingMode2,Betriebsart: Operating mode of the water circuit,,,b509,0d2b00,value,,UCH,0=disabled;1=on;2=off;3=auto;4=eco;5=low,,Mischer Modus
w,,,OperatingMode2,Betriebsart: Operating mode of the water circuit,,,b509,0e2b00,value,,UCH,0=disabled;1=on;2=off;3=auto;4=eco;5=low,,Mischer Modus
r,,,TempDesired2,Solltemperatur: Temperature setpoint of water tank,,,b509,0d3200,value,,D1C,,°C,Temperatur
w,,,TempDesired2,Solltemperatur: Temperature setpoint of water tank,,,b509,0e3200,value,,D1C,,°C,Temperatur
r,,,TeleswitchOperatingMode2,TeleSWITCH Betriebsart: If the tele switch port is activated the water circuit operates in this mode,,,b509,0d3f00,value,,UCH,0=disabled;1=on;2=off;3=auto;4=eco;5=low,,Mischer Modus
w,,,TeleswitchOperatingMode2,TeleSWITCH Betriebsart: If the tele switch port is activated the water circuit operates in this mode,,,b509,0e3f00,value,,UCH,0=disabled;1=on;2=off;3=auto;4=eco;5=low,,Mischer Modus
r,,,DateTime,Datum Uhrzeit,,,b504,00,dcfstate,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF Empfängerstatus,btime,,BTI,,,Uhrzeit,bdate,,BDA,,,Datum,temp,,D2B,,°C,Temperatur
r,,,Mode,Betriebsmodus,,,b504,01,temp,,UCH,,°C,Temperatur,hwcmode,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,ign,,IGN:2,,,,hwcmode_1,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,Mischer Typ,hex,,HEX,,,,daynight,,UCH,0=night;1=day;7=floorpaving,,Tag-/Nachtmodus
w,,,SetTempDesired,Solltemperatur setzen,,,b505,01,value,,UCH,,°C,Temperatur
w,,,SetMode,Betriebsart setzen,,,b505,02,value,,UCH,0=disabled;1=on;2=off;3=auto,,Warmwasser Modus
w,,,SetFlowTempMin,Minimalen Vorlaufsollwert setzen,,,b505,0e,value,,UCH,,°C,Temperatur
w,,,SetFlowTempMax,Maximalen Vorlaufsollwert setzen,,,b505,0f,value,,UCH,,°C,Temperatur
r,,,Params,Parameter,,,b504,09,temp,,UCH,,°C,Temperatur,ign,,IGN:3,,,,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,Mischer Typ,temps,,SCH,,°C,Temperatur,ign_1,,IGN,,,,temps_1,,SCH,,°C,Temperatur,temps_2,,SCH,,°C,Temperatur,ign_2,,IGN,,,
r,,,Status0a,Status Vorlauf Ist/Mixer/Pumpe/Vorlauf Soll,,,b504,0a,flowtemp,,D2C,,°C,Temperatur,mixer,,UCH,0=off;1=open;2=close,,Mixer Status,pump,,UCH,0=off;1=on,,,onoff,,UCH,0=off;1=on,,,flowtempdesired,,UCH,,°C,Temperatur
r,,,Status,Soll/Status/Ist/Soll,,,b504,0d,temp,,UCH,,°C,Temperatur,onoff,,UCH,0=off;1=on,,,temp_1,,D2C,,°C,Temperatur,temp_2,,UCH,,°C,Temperatur
r,,,Status16,Außentemperatur,,,b504,16,value,,D2C,,°C,Temperatur
r,,,Timer_Monday,Zeitfenster Montag,,,b504,02,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Monday,Zeitfenster Montag,,,b505,0901,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Tuesday,Zeitfenster Dienstag,,,b504,03,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Tuesday,Zeitfenster Dienstag,,,b505,0902,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Wednesday,Zeitfenster Mittwoch,,,b504,04,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Wednesday,Zeitfenster Mittwoch,,,b505,0903,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Thursday,Zeitfenster Donnerstag,,,b504,05,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Thursday,Zeitfenster Donnerstag,,,b505,0904,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Friday,Zeitfenster Freitag,,,b504,06,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Friday,Zeitfenster Freitag,,,b505,0905,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Saturday,Zeitfenster Samstag,,,b504,07,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Saturday,Zeitfenster Samstag,,,b505,0906,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
r,,,Timer_Sunday,Zeitfenster Montag,,,b504,08,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,,Timer_Sunday,Zeitfenster Montag,,,b505,0907,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,from,,TTM,,,von,to,,TTM,,,bis,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,Tage
w,,install,Iotest,I/O Test,,,b506,02,value,,UCH,0=valve1;1=cirpump;2=pump1;3=hc2mixeropen;4=hc2mixerclose;5=hc2pump;6=col1pump;7=col2pump;8=valve2;9=valve3;10=legiopump;11=valve4;12=c1c2,,
w,,install,Ioteststop,I/O Test stoppen,,,b506,01,
r,,,Currenterror,Aktuelle Fehler,,,b503,0001,error,,UIN,,,Fehlernummer,error_1,,UIN,,,Fehlernummer,error_2,,UIN,,,Fehlernummer,error_3,,UIN,,,Fehlernummer,error_4,,UIN,,,Fehlernummer
r,,,Errorhistory,Fehlerhistorie,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,Uhrzeit,date,,HDA:3,,,Datum,error,,UIN,,,Fehlernummer
w,,install,Clearerrorhistory,Fehlerhistorie löschen,,,b503,0201,cleared,s,UCH,0=no;1=yes,,