Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path05.vd4.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
132 lines (132 loc) · 13.4 KB
/
05.vd4.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
*[id_sw],scan,,,,SW
[id_sw>=200]r,,,ComErrorDelay,default *r for register,,,b509,0d4300,value,,UIN,,Control interface,
[id_sw>=200]w,,service,ComErrorDelay,"default *ws for register with user level ""service""",,,b509,0e4300,value,,UIN,,Control interface,
r,,,SoftwareVersion,default *r for register,,,b509,0d0000,value,,HEX:4,,,
w,,install,SoftwareVersion,"default *wi for register with user level ""install""",,,b509,0e0000,value,,HEX:4,,,
r,,,EnableMonitoring,default *r for register,,,b509,0d0100,value,,HEX:5,,,
w,,install,EnableMonitoring,"default *wi for register with user level ""install""",,,b509,0e0100,value,,HEX:5,,,
r,,,FlexibleMonitoring,default *r for register,,,b509,0d0200,value,,HEX:8,,,
w,,install,FlexibleMonitoring,"default *wi for register with user level ""install""",,,b509,0e0200,value,,HEX:8,,,
r,,,DataCollectionRequest,installer level register,,,b509,0d0300,value,,UCH,,,
w,,install,DataCollectionRequest,installer level register,,,b509,0e0300,value,,UCH,,,
r,,,DataCollectionBuffer,installer level register,,,b509,0d0400,value,,UCH,,,
w,,install,DataCollectionBuffer,installer level register,,,b509,0e0400,value,,UCH,,,
r,,,DataCollCycle,installer level register,,,b509,0d0500,value,,ULG,,,
w,,install,DataCollCycle,installer level register,,,b509,0e0500,value,,ULG,,,
r,,,DataCollBufSize,installer level register,,,b509,0d0600,value,,ULG,,,
w,,install,DataCollBufSize,installer level register,,,b509,0e0600,value,,ULG,,,
r,,,EnableBcErrMsg,Enable broadcast error messages: Brodcast error messages on the eBUS will be send to the server,,,b509,0d0700,value,,UCH,0=no;1=yes,,
w,,install,EnableBcErrMsg,Enable broadcast error messages: Brodcast error messages on the eBUS will be send to the server,,,b509,0e0700,value,,UCH,0=no;1=yes,,
r,,,BoxSerialNumber1,default *r for register,,,b509,0d0800,value,,HEX:9,,,
w,,install,BoxSerialNumber1,"default *wi for register with user level ""install""",,,b509,0e0800,value,,HEX:9,,,
r,,,BoxSerialNumber2,default *r for register,,,b509,0d0900,value,,HEX:9,,,
w,,install,BoxSerialNumber2,"default *wi for register with user level ""install""",,,b509,0e0900,value,,HEX:9,,,
r,,,BoxSerialNumber3,default *r for register,,,b509,0d0a00,value,,HEX:9,,,
w,,install,BoxSerialNumber3,"default *wi for register with user level ""install""",,,b509,0e0a00,value,,HEX:9,,,
r,,,BoxSerialNumber4,default *r for register,,,b509,0d0b00,value,,HEX:9,,,
w,,install,BoxSerialNumber4,"default *wi for register with user level ""install""",,,b509,0e0b00,value,,HEX:9,,,
r,,,DeviceLayout,Device Layout,,,b509,0d0c00,value,,UCH,0=_unknown;1=JV_PC;2=H2B;3=_1_16;4=complex;5=eBUSheater,,Type of Interface which will be used and definition of appliance
w,,install,DeviceLayout,Device Layout,,,b509,0e0c00,value,,UCH,0=_unknown;1=JV_PC;2=H2B;3=_1_16;4=complex;5=eBUSheater,,Type of Interface which will be used and definition of appliance
r,,,DeviceLayoutCRC,Layout Checksum: Checksum over all devives connected to vrnetDIALOG. Will be used from the server to find out if new devices added or devices are deleted,,,b509,0d0d00,value,,UCH,,,
w,,install,DeviceLayoutCRC,Layout Checksum: Checksum over all devives connected to vrnetDIALOG. Will be used from the server to find out if new devices added or devices are deleted,,,b509,0e0d00,value,,UCH,,,
r,,,AutoSyncEnable,AutoSync enabled: Enabling or disabling of the AutoYync on the eBUS. Only usefull if there problems with outher AutoSync devices on the eBUS.,,,b509,0d0e00,value,,UCH,0=off;1=on,,
w,,install,AutoSyncEnable,AutoSync enabled: Enabling or disabling of the AutoYync on the eBUS. Only usefull if there problems with outher AutoSync devices on the eBUS.,,,b509,0e0e00,value,,UCH,0=off;1=on,,
r,,,LastConnectionError,Last connection error,,,b509,0d0f00,value,,UCH,0=none;1=connection;2=PPP;3=TCPopen;4=TCPauth;5=TCPsend,,Shows the last state where the connection has failed.
w,,install,LastConnectionError,Last connection error,,,b509,0e0f00,value,,UCH,0=none;1=connection;2=PPP;3=TCPopen;4=TCPauth;5=TCPsend,,Shows the last state where the connection has failed.
r,,,ConnErrorRetryDelay,Connection error retry delay [minutes]: Delay between two connection tries in case of a connection error,,,b509,0d1000,value,,UCH,,,
w,,install,ConnErrorRetryDelay,Connection error retry delay [minutes]: Delay between two connection tries in case of a connection error,,,b509,0e1000,value,,UCH,,,
r,,,ConnectionDelay,Connection Delay [minutes]: Minimum delay between two server connections established by the dialog box.,,,b509,0d1100,value,,UCH,,,
w,,install,ConnectionDelay,Connection Delay [minutes]: Minimum delay between two server connections established by the dialog box.,,,b509,0e1100,value,,UCH,,,
r,,,ErrorMessage,installer level register,,,b509,0d1200,value,,UCH,,,
w,,install,ErrorMessage,installer level register,,,b509,0e1200,value,,UCH,,,
r,,,ConnErrorCnt,Connection error counter: Number of connection tries. Will be reset to zero after a successful connection,,,b509,0d1300,value,,UCH,,,
w,,install,ConnErrorCnt,Connection error counter: Number of connection tries. Will be reset to zero after a successful connection,,,b509,0e1300,value,,UCH,,,
r,,,PppPhoneNumber1,PPP phone number 1,,,b509,0d1400,value,,STR:21,,,Fon number or ATN of the first PPP provider selected by server
w,,install,PppPhoneNumber1,PPP phone number 1,,,b509,0e1400,value,,STR:21,,,Fon number or ATN of the first PPP provider selected by server
r,,,PppLogin1,PPP Login 1,,,b509,0d1500,value,,STR:21,,,Login for the first internetprovider
w,,install,PppLogin1,PPP Login 1,,,b509,0e1500,value,,STR:21,,,Login for the first internetprovider
r,,,PppPassword1,PPP Password 1,,,b509,0d1600,value,,STR:21,,,Password for the first internet provider
w,,install,PppPassword1,PPP Password 1,,,b509,0e1600,value,,STR:21,,,Password for the first internet provider
r,,,PppPhoneNumber2,Phone number provider 1,,,b509,0d1700,value,,STR:21,,,
w,,install,PppPhoneNumber2,Phone number provider 1,,,b509,0e1700,value,,STR:21,,,
r,,,PppLogin2,PPP Login 2,,,b509,0d1800,value,,STR:21,,,Login for second internetprovide
w,,install,PppLogin2,PPP Login 2,,,b509,0e1800,value,,STR:21,,,Login for second internetprovide
r,,,PppPassword2,PPP Password 2,,,b509,0d1900,value,,STR:21,,,Paswword for second internetprovider
w,,install,PppPassword2,PPP Password 2,,,b509,0e1900,value,,STR:21,,,Paswword for second internetprovider
r,,,ServerIpAddr,Server IP address,,,b509,0d1a00,uch,,UCH,,,,uch_1,,UCH,,,,uch_2,,UCH,,,,uch_3,,UCH,,,
w,,install,ServerIpAddr,Server IP address,,,b509,0e1a00,uch,,UCH,,,,uch_1,,UCH,,,,uch_2,,UCH,,,,uch_3,,UCH,,,
r,,,ActualGsmProvider,Actual GSM/GPRS provider,,,b509,0d1b00,value,,STR:5,,,Information which provider has been selectet. Only valid in case of GSM/GPRS modem.
w,,install,ActualGsmProvider,Actual GSM/GPRS provider,,,b509,0e1b00,value,,STR:5,,,Information which provider has been selectet. Only valid in case of GSM/GPRS modem.
r,,,ModemInitString,Modem init string,,,b509,0d1c00,value,,STR:21,,,Special string for initialsing the modem. Default empty. Wrong values can cause a dialog box which can't communicate.
w,,install,ModemInitString,Modem init string,,,b509,0e1c00,value,,STR:21,,,Special string for initialsing the modem. Default empty. Wrong values can cause a dialog box which can't communicate.
r,,,RingTimeGsmCB,Call back delay GSM/GPRS [s]: Time between the last ring and the call back.,,,b509,0d1e00,value,,UCH,,,
w,,install,RingTimeGsmCB,Call back delay GSM/GPRS [s]: Time between the last ring and the call back.,,,b509,0e1e00,value,,UCH,,,
r,,,RingsBeforePickup,Rings before pickup: Only for analog modems used. 0 = will never pick up.,,,b509,0d1f00,value,,UCH,,,
w,,install,RingsBeforePickup,Rings before pickup: Only for analog modems used. 0 = will never pick up.,,,b509,0e1f00,value,,UCH,,,
r,,,RingTimeTSM1,installer level register,,,b509,0d2000,value,,UCH,,,
w,,install,RingTimeTSM1,installer level register,,,b509,0e2000,value,,UCH,,,
r,,,RingTimeTSM2,installer level register,,,b509,0d2100,value,,UCH,,,
w,,install,RingTimeTSM2,installer level register,,,b509,0e2100,value,,UCH,,,
r,,,MessageThreshold,installer level register,,,b509,0d2200,value,,UCH,,,
w,,install,MessageThreshold,installer level register,,,b509,0e2200,value,,UCH,,,
r,,,ConnectionCycle,installer level register,,,b509,0d2300,value,,UCH,,,
w,,install,ConnectionCycle,installer level register,,,b509,0e2300,value,,UCH,,,
r,,,FieldStrengthMax,Max. signal strength GSM/GPRS: Max value since last power on (0..31),,,b509,0d2400,value,,UCH,,,
w,,install,FieldStrengthMax,Max. signal strength GSM/GPRS: Max value since last power on (0..31),,,b509,0e2400,value,,UCH,,,
r,,,FieldStrengthMin,Min. signal strength GSM/GPRS: Min. value since last power on (0..31),,,b509,0d2500,value,,UCH,,,
w,,install,FieldStrengthMin,Min. signal strength GSM/GPRS: Min. value since last power on (0..31),,,b509,0e2500,value,,UCH,,,
r,,,EnableDisErrorMsg,Enable OK message: If on a error free message will be sent to the server.,,,b509,0d2600,value,,UCH,0=off;1=on,,
w,,install,EnableDisErrorMsg,Enable OK message: If on a error free message will be sent to the server.,,,b509,0e2600,value,,UCH,0=off;1=on,,
r,,,SwitchRelays,Relay outputs,,,b509,0d2700,bi,,BI0,,,,bi_1,,BI1,,,
w,,install,SwitchRelays,Relay outputs,,,b509,0e2700,bi,,BI0,,,,bi_1,,BI1,,,
r,,,StandbySignal,installer level register,,,b509,0d2b00,value,,UCH,,,
w,,install,StandbySignal,installer level register,,,b509,0e2b00,value,,UCH,,,
r,,,PowerOnMessage,Power on alarm: If on a alarm message is sent after power on,,,b509,0d2c00,value,,UCH,0=off;1=on,,
w,,install,PowerOnMessage,Power on alarm: If on a alarm message is sent after power on,,,b509,0e2c00,value,,UCH,0=off;1=on,,
r,,,AlarmOnDelay,default *r for register,,,b509,0d2e00,uin,,UIN,,,,uin_1,,UIN,,,
w,,install,AlarmOnDelay,"default *wi for register with user level ""install""",,,b509,0e2e00,uin,,UIN,,,,uin_1,,UIN,,,
r,,,AlarmOffDelay,default *r for register,,,b509,0d2f00,uin,,UIN,,,,uin_1,,UIN,,,
w,,install,AlarmOffDelay,"default *wi for register with user level ""install""",,,b509,0e2f00,uin,,UIN,,,,uin_1,,UIN,,,
r,,,ScanLayoutCycle,installer level register,,,b509,0d3000,value,,UCH,,,
w,,install,ScanLayoutCycle,installer level register,,,b509,0e3000,value,,UCH,,,
r,,,PredMaintConnectionCycle,installer level register,,,b509,0d3100,value,,UCH,,,
w,,install,PredMaintConnectionCycle,installer level register,,,b509,0e3100,value,,UCH,,,
r,,,LastKnownEbusAddr,installer level register,,,b509,0d3200,value,,UCH,,,
w,,install,LastKnownEbusAddr,installer level register,,,b509,0e3200,value,,UCH,,,
r,,,Time,installer level register,,,b509,0d3300,value,,VTI,,,time
w,,install,Time,installer level register,,,b509,0e3300,value,,VTI,,,time
r,,,Date,installer level register,,,b509,0d3400,value,,HDA:3,,,date
w,,install,Date,installer level register,,,b509,0e3400,value,,HDA:3,,,date
r,,,Weekday,installer level register,,,b509,0d3500,value,,BDY,,,weekday
w,,install,Weekday,installer level register,,,b509,0e3500,value,,BDY,,,weekday
r,,,CurrentPppProvider,default *r for register,,,b509,0d3600,value,,UCH,0=_1;1=_2;2=emergency_provider,,
w,,install,CurrentPppProvider,"default *wi for register with user level ""install""",,,b509,0e3600,value,,UCH,0=_1;1=_2;2=emergency_provider,,
r,,,GsmGprsPin,GSM SIM Pin,,,b509,0d3700,value,,STR:4,,,Wrong pin disables the box functionality
w,,install,GsmGprsPin,GSM SIM Pin,,,b509,0e3700,value,,STR:4,,,Wrong pin disables the box functionality
r,,,ModemType,default *r for register,,,b509,0d3800,value,,UCH,0=analogue;1=GSM;2=GPRS,,
w,,install,ModemType,"default *wi for register with user level ""install""",,,b509,0e3800,value,,UCH,0=analogue;1=GSM;2=GPRS,,
r,,,H2BusLayout,installer level register,,,b509,0d3900,value,,UCH,,,
w,,install,H2BusLayout,installer level register,,,b509,0e3900,value,,UCH,,,
r,,,ActualDigitalInputs,Digital input actual values,,,b509,0d3a00,bi,,BI0,,,,bi_1,,BI1,,,
w,,install,ActualDigitalInputs,Digital input actual values,,,b509,0e3a00,bi,,BI0,,,,bi_1,,BI1,,,
r,,,ActualAnalogInputs,Analog inputs actual values,,,b509,0d3b00,uin,,UIN,,,,uin_1,,UIN,,,
w,,install,ActualAnalogInputs,Analog inputs actual values,,,b509,0e3b00,uin,,UIN,,,,uin_1,,UIN,,,
r,,,ActualCounterValue,Counter inputs actual values,,,b509,0d3c00,uin,,UIN,,,,uin_1,,UIN,,,
w,,install,ActualCounterValue,Counter inputs actual values,,,b509,0e3c00,uin,,UIN,,,,uin_1,,UIN,,,
r,,,ModemDialPrefix,Modem dial prefix,,,b509,0d3d00,value,,STR:4,,,Prefix which will be sent to the modem befor dialing
w,,install,ModemDialPrefix,Modem dial prefix,,,b509,0e3d00,value,,STR:4,,,Prefix which will be sent to the modem befor dialing
r,,,DebugFlags,installer level register,,,b509,0d3e00,value,,ULG,,,
w,,install,DebugFlags,installer level register,,,b509,0e3e00,value,,ULG,,,
r,,,ModemCountryCode,Modem country code,,,b509,0d3f00,value,,UCH,,,
w,,install,ModemCountryCode,Modem country code,,,b509,0e3f00,value,,UCH,,,
r,,,DoReset,installer level register,,,b509,0d4000,value,,UCH,,,
w,,install,DoReset,installer level register,,,b509,0e4000,value,,UCH,,,
r,,,DataCollectionLimit,installer level register,,,b509,0d4100,value,,ULG,,,
w,,install,DataCollectionLimit,installer level register,,,b509,0e4100,value,,ULG,,,
r,,,Temp3WayValve,installer level register,,,b509,0d4200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
w,,install,Temp3WayValve,installer level register,,,b509,0e4200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,RfWakeupCycle,service level register,,,b509,0d4600,value,,UIN,,,
w,,service,RfWakeupCycle,service level register,,,b509,0e4600,value,,UIN,,,