type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,Ntc1Sensor,Ntc1Sensor: Temperature in solar flow (from solar collector),,,b509,0d0500,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,Ntc2Sensor,Ntc2Sensor: Temperature in solar back flow (to solar collector),,,b509,0d0600,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,SolPumpRelay,Relais Solarpumpe: Solar pump relay: 0: OFF; 1: ON,,,b509,0d0f00,value,,UCH,0=off;1=on,,
w,,install,SolPumpRelay,Relais Solarpumpe: Solar pump relay: 0: OFF; 1: ON,,,b509,0e0f00,value,,UCH,0=off;1=on,,
r,,,SolPumpPower,SolarPumpPower: Performance of solar pump: (7 - 100 %),,,b509,0d1000,value,,UCH,,kW,
w,,install,SolPumpPower,SolarPumpPower: Performance of solar pump: (7 - 100 %),,,b509,0e1000,value,,UCH,,kW,
r,,,BufferPumpPower,BufferPumpPower: Performance of buffer pump: (15 - 100%),,,b509,0d1100,value,,UCH,,kW,
w,,install,BufferPumpPower,BufferPumpPower: Performance of buffer pump: (15 - 100%),,,b509,0e1100,value,,UCH,,kW,
r,,,MonitorMatlabLast5minSolAverage,MonitorMatlab_Last5minSolarAverage,,,b509,0d1700,value,,SIN,,,
r,,,CurrentVPMLoadingMode,"CurrentVPM_LoadingMode: 1. DHW-Support (stand alone), 2. CH-Support (stand alone), 3. +10K (stand alone), 4. SwimmingPool, 5.DHW-Support (with external control), 6. CH-Support (with external control), 7. +10K (with external control)",,,b509,0d1900,value,,UCH,,,
r,,,RunTimePump1Minutes,RunTimePump1_Minutes: Runtime of solar pump in minutes,,,b509,0d1a00,value,,UCH,,min,minutes
r,,,RunTimePump1Hours,RunTimePump1_Hours: Runtime of solar pump in hours,,,b509,0d1b00,value,,UIN,,h,hours
r,,,ExternalHwcRequest,ExternalDHWRequest: 0: No request; 1: Request,,,b509,0d1c00,value,,UCH,0=off;1=on,,
r,,,ExternalHcRequest,ExternalCHRequest: 0: No request; 1: Request,,,b509,0d1d00,value,,UCH,0=off;1=on,,
r,,,ExternalHwcTempDesired,ExternalDHWSetpoint: Requested temperature for DHW,,,b509,0d1e00,value,,UCH,,°C,desired temperature
r,,,ExternalHcTempDesired,ExternalCHSetpoint: Requested temperature for CH,,,b509,0d1f00,value,,UCH,,°C,desired temperature
r,,,CurrentASCStateforExternals,CurrentASCStateforExternals: 1:OFF 2: Proofing 3:DHWLoading 4:CHLoading 5:Overtemperature,,,b509,0d2000,value,,UCH,,,
r,,,CurrentASCStateforASI,CurrentASCStateforASI: 1: Standby 2:Proofing 3:StorageLoading 4:Error_System_blocked,,,b509,0d2100,value,,UCH,,,
r,,,DateAndTimeIsSet,DateAndTimeIsSet: 0: Date and Time is not set; 1: Date and Time is set,,,b509,0d2200,value,,UCH,0=off;1=on,,
r,,,Time,time,,,b509,0d2300,value,,VTI,,,time
w,,install,Time,time,,,b509,0e2300,value,,VTI,,,time
r,,,Date,date,,,b509,0d2400,value,,HDA:3,,,date
w,,install,Date,date,,,b509,0e2400,value,,HDA:3,,,date
r,,,FlowSensorFrequency,FlowSensorFrequency,,,b509,0d2d00,value,,UIN,,,
r,,,CurrentFlow,CurrentFlow,,,b509,0d2e00,value,,UIN,,ml / min,Flow thru buffer circuit if loading the storage
r,,,Variante,Variante: 1: VMS 30 2: VPM 20 S 3: VPM 60 S (identified by resistor in harness),,,b509,0d3000,value,,UCH,,,
r,,,CurrentSystemMode,"CurrentSystemMode: 1: Standalone, 3: With external control",,,b509,0d3300,value,,UCH,,,
r,,,InternalHwcTempDesired,InternalDHWSetpoint: Temperature target for DHW loading if solar module is in stand alone appliccation without external control,,,b509,0d3500,value,,UCH,,,
r,,,InternalHcTempDesired,InternalCHSetpoint: Temperature target for CW loading if solar module is in stand alone appliccation without external control,,,b509,0d3600,value,,UCH,,,
r,,,ASIDetected,ASIDetected,,,b509,0d3800,value,,UCH,0=off;1=on,,
r,,,CountryZone,CountryZone: Location for calculation of sun calender. See list in control manual (default = 2: Germany),,,b509,0d3900,value,,UCH,,,
w,,install,CountryZone,CountryZone: Location for calculation of sun calender. See list in control manual (default = 2: Germany),,,b509,0e3900,value,,UCH,,,
r,,,RequestForExternalDateTimeSetting,RequestForExternalDateTimeSetting: 0: Time and Date is set; 1: Time and Date is not set,,,b509,0d3a00,value,,UCH,0=off;1=on,,
r,,,YieldCurrentDay,SolarYieldCurrentDay: Accumulated solar gain from 00:00 to 24:00 if time is set,,,b509,0d3b00,value,,UIN,,kWh,
w,,install,YieldCurrentDay,SolarYieldCurrentDay: Accumulated solar gain from 00:00 to 24:00 if time is set,,,b509,0e3b00,value,,UIN,,kWh,
r,,,ForceStartSolPumpKick,"ForceStartSolarPumpKick: Start solar pump for max. 5min to check collector temperature 0: OFF, 1: ON",,,b509,0d4700,value,,UCH,0=off;1=on,,
r,,,MonitorMatlabState,MonitorMatlabState: main states: 201: Waiting; 209: Loading; 41: Night Modus,,,b509,0d4800,value,,UCH,,,
r,,,RunTimeBufferPumpMinutes,RunTimeBufferPump_Minutes: Runtime of buffer pump in minutes,,,b509,0d4b00,value,,UCH,,min,minutes
r,,,RunTimeBufferPumpHours,RunTimeBufferPump_Hours: Runtime of buffer pump in hours,,,b509,0d4c00,value,,UIN,,h,hours
r,,,MonitorOverheatState,MonitorOverheatState: 111: Waiting; 112 and 113: Temperature to high; 220 and 221: In Overheat protection,,,b509,0d4f00,value,,UCH,,,
r,,,YieldTotal,SolarYieldTotal: Accumulated solar gain since installation,,,b509,0d5600,value,,ULG,,kWh,
w,,install,YieldTotal,SolarYieldTotal: Accumulated solar gain since installation,,,b509,0e5600,value,,ULG,,kWh,
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,