-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.370.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
146 lines (146 loc) · 22.1 KB
/
15.370.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0d5f00,value,,BDY,,,weekday
r,,,Date,current date,,,b509,0d6100,value,,HDA:3,,,date
w,,,Date,current date,,,b509,0e6100,value,,HDA:3,,,date
r,,,Time,current time,,,b509,0d6000,value,,VTI,,,time
w,,,Time,current time,,,b509,0e6000,value,,VTI,,,time
r,,,RoomTemp,RaumtemperaturIst: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0d5700,value,,SCH,2,K,
w,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0e5700,value,,SCH,2,K,
r,,,DisplayedHc1RoomTempDesired,"DisplayedHK1RoomSetpoint: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,temperature
r,,,Hc1OPMode,HC1_OPMode,,,b509,0d2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
w,,,Hc1OPMode,HC1_OPMode,,,b509,0e2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
r,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0d2700,value,,D1C,,°C,temperature
w,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0e2700,value,,D1C,,°C,temperature
r,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0d3000,value,,D1C,,°C,temperature
w,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0e3000,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoTemp,HC1_QuickVetoTemp: manual override setpoint of the first heating circuit,,,b509,0d3c00,value,,D1C,,°C,temperature
r,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,Hc1SFMode,HC1_SFMode,,,b509,0d5d00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of first heating circuit
r,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0d1100,value,,HDA:3,,,date
w,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0e1100,value,,HDA:3,,,date
r,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0d1200,value,,HDA:3,,,date
w,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0e1200,value,,HDA:3,,,date
r,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0d2100,value,,HDA:3,,,date
w,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0e2100,value,,HDA:3,,,date
r,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0d2200,value,,HDA:3,,,date
w,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0e2200,value,,HDA:3,,,date
r,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,temperature
w,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,temperature
r,,,HcName1,"aaucHcNames_HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0d3f00,value,,STR:11,,,heat circuit name
w,,,HcName1,"aaucHcNames_HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0e3f00,value,,STR:11,,,heat circuit name
r,,,ContactName,aucContactName,,,b509,0db400,value,,STR:13,,,"installer's name (only A-Z,0-9,blank)"
w,,install,ContactName,aucContactName,,,b509,0eb400,value,,STR:13,,,"installer's name (only A-Z,0-9,blank)"
r,,,PhoneNumber,aucPhoneNumber,,,b509,0d5400,value,,STR:13,,,"installer's telephone number (only 0-9,-,blank)"
w,,install,PhoneNumber,aucPhoneNumber,,,b509,0e5400,value,,STR:13,,,"installer's telephone number (only 0-9,-,blank)"
r,,,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0d5900,value,,HDA:3,,,date
w,,install,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0e5900,value,,HDA:3,,,date
r,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0d5a00,value,,UCH,,,
w,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0e5a00,value,,UCH,,,
r,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust,,,b509,0d5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
w,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust,,,b509,0e5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
r,,,LanguageVariant,LanguageVariant,,,b509,0d1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
w,,,LanguageVariant,LanguageVariant,,,b509,0e1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
r,,,BMUFlowTempOrVF1,BMU_FlowTempOrVF_1: value of either an externally connected flow temperature sensor or the BMU's internal flow sensor if an external sensor is missing,,,b509,0d8700,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,RoomTempOffsetSelfWarming,RaumTempOffsetEigenErwaerm: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,temperature
r,,,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0d3600,value,,UCH,0=two_point_control;1=analogue_control,,two-point / analogue control
w,,install,Hc12stepanalogCtrl,HC1_2stepanalogCtrl,,,b509,0e3600,value,,UCH,0=two_point_control;1=analogue_control,,two-point / analogue control
r,,,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: adjustment of closed loop control,,,b509,0d3700,value,,SCH,,,
w,,install,Hc1LineMatchingAdaption,HC1_LineMatchingAdaption: adjustment of closed loop control,,,b509,0e3700,value,,SCH,,,
r,,,CirPump,CircuPumpRunning: circulation pump's state,,,b509,0d8100,value,,UCH,0=no;1=yes,,
r,,,Hc1ActualFlowTempDesired,HC1ActualFlowSetPoint: current flow temperature setpoint of the first heating circuit,,,b509,0d3e00,value,,D1C,,°C,temperature
r,,,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
w,,install,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
r,,,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,time
w,,install,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,time
r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature (also in case of an SP1error),,,b509,0d9e00,value,,D1C,,°C,temperature
r,,,HwcActualTempDesired,DHW_ActualDesired_Setpoint: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,temperature
r,,,KeyCodeforConfigMenu,KeyCodeforConfigMenue: code for the installer's menues,,,b509,0d5500,value,,PIN,,,
w,,install,KeyCodeforConfigMenu,KeyCodeforConfigMenue: code for the installer's menues,,,b509,0e5500,value,,PIN,,,
r,,,GlobalSystemOff,"GlobalSystemOFF: Set to TRUE if ""System Off"" is selected",,,b509,0d0100,value,,UCH,0=off;1=on,,
r,,,StatusDcf,StatusDcf,,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=validDCF;4=validRTC,,status of the DCF signal
r,,,DcfIsValid,DcfIsValid: validity of DCF signal,,,b509,0d0400,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,HydraulicMap,"HydraulicMap: hydraulic map (0 = H1, 3 = H4, 11 = A1, 12 = A2, 14 = A5, 15 = S1, 16 = S3a, 17 = S3b)",,,b509,0d1800,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,ActualRoomTempSetpointHC1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,temperature
r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
r,,,B51000M8HeatFlowSetMonitor,B51000M8HeatFlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,,
r,,,B51000M9TappingSetMon,B51000M9TappingSetMon: DHW setpoint without loading offset (for hydraulic map H1),,,b509,0d5600,value,,D1C,,,
r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (left bit 0, right bit 7)",,,b509,0d6700,value,,UCH,,,
r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (left bit 0, right bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
r,,,TestVarActivateFunction,TestVarActivateFunction: 0=All SF_OFF11/2=1DayHolON/OFF13/4=1DayBankON/OFF19/10=1xDHWLoadON/OFF11/12=QVetoON/OFF115/16=PartyON/OFF119/20=Ventil.ON/OFF123/24=SystemOff_ON/OFF,,,b509,0d0b00,value,,UCH,,,
r,,,HwcOPMode,"DHW_OPMode: operation mode of the domestic hot water circuit set implicitly (0 = off, 1 = on, 2 = auto, 3 = auto sunday, 4 = party, 6 = one time tank loading, 7 = holiday)",,,b509,0d4200,value,,UCH,,,
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,,,
r,,,B51000TempDesiredLoadingPump,B51000SetPointLoadingPump: loading pump's setpoint sent via B5 10 00 to the BMU,,,b509,0d7b00,value,,D1C,,,
r,,,BMUB51101BoilerFlowTemp,BMUB51101_BoilerFlowTemp: current flow temperature inside the BMU,,,b509,0d7700,value,,D1C,,°C,temperature
r,,,BMUB51101StorageTemp,BMUB51101_TankTemp: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,temperature
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,StartEepromUpdate,StarteEepromAktualisierung: update of the EEPROM has to be started,,,b509,0d0e00,value,,UCH,0=no;1=yes,,
r,,,EepromUpdateActive,EepromAktualisierungAktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=no;1=yes,,
r,,,ChimneySweepModeActive,ChimneySweepModeActive: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,HwcLoadingIn430Active,DHWLoadingIn430Active: DHW-loading is active in non parallel loading cases,,,b509,0d9300,value,,UCH,0=no;1=yes,,
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,InstallAssistant,"InstallAssistant: install assistant not active (0 = active, 1 = not active)",,,b509,0d5e00,value,,UCH,0=off;1=on,,
r,,,FactoryTestActive,FactoryTestAktiv: Factory Test Pin,,,b509,0d1000,value,,UCH,0=no;1=yes,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,PumpEnergySaveStateMonitor,PumpEnergySaveStateMonitor: monitoring of the pump energy saving's state transition diagram,,,b509,0d9100,value,,UCH,,,
r,,,PumpEnergySaveCalculatedTimeMonitor,PumpEnergySaveCalculatedTimeMonitor: calculated time for the heating circuit's pump's switch off time during pump energy saving function (depends on outside temperature),,,b509,0d9200,value,,UCH,,min,minutes
r,,,ActoSTOROPMode,actoSTOR_OPMode: state diagram actoSTOR control,,,b509,0d9400,value,,UCH,,,
r,,,ClockSwitchSummerWinterDone,ClockSwitchSummerWinterDone: automatic switching over to/from daylight saving's time has been done,,,b509,0d7800,value,,UCH,0=no;1=yes,,
r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
r,,,MonitorCurrentIPart,MonitorCurrent_I_Anteil: current i-control value; updated every 3 minutes,,,b509,0d3300,value,,D2C,,°C,temperature
r,,,CountryVariant,"CountryVariant: country variant (0 = west, 1 = east, 2 = all)",,,b509,0d1700,value,,UCH,,,
r,,,DisplayedRoomTemp,DisplayedRoomTemp: displayed room temperature,,,b509,0d8000,value,,D2C,,°C,temperature
r,,,RaumtempIstUnten,RaumtempIstUnten: lower room temp sensor value,,,b509,0dc100,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,ADCValueTempbelow,ADCValue_T_below: lower room temp sensor ADC value,,,b509,0d4e00,value,,UIN,,,
r,,,CcTimer_Monday,Periods Monday,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Monday,Periods Monday,,,b515,0002,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Friday,Periods Friday,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Friday,Periods Friday,,,b515,0402,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Monday,Periods Monday,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Monday,Periods Monday,,,b515,0001,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Friday,Periods Friday,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Friday,Periods Friday,,,b515,0401,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Monday,Periods Monday,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Monday,Periods Monday,,,b515,0000,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Friday,Periods Friday,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Friday,Periods Friday,,,b515,0400,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,