-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.430.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
222 lines (222 loc) · 32.5 KB
/
15.430.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*w,
*r,
*[id_sw],scan,,,,SW
[id_sw>=215]w,,,HwcQuickVetoTemp,DHW_QuickVetoTemp,,,b509,0e4500,value,,D1C,,°C,manual override setpoint for the domestic hot water circuit
[id_sw>=215]w,,,HwcQuickVetoActive,DHW_QuickVetoActive,,,b509,0e4300,value,,UCH,0=no;1=yes,,manual override of the domestic hot water circuit enabled
[id_sw>=125]r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature in C4 (also in case of an SP1 error),,,b509,0d9e00,value,,D1C,,°C,temperature
[id_sw>=125]r,,,HwcLoadingInBMUActive,DHWLoadingInBMUActive: indicates that BMU is in DHW preparation,,,b509,0d9d00,value,,UCH,0=no;1=yes,,
[id_sw>=125]r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
[id_sw>=216]r,,,Hc1FloorPavementDryingTemp,HC1_FloorPavementDryingTemperature: HC1's current flow temperature setpoint with activated floor pavement drying,,,b509,0d2a00,value,,D1C,,°C,temperature
[id_sw>=216]r,,,Hc1FloorPavementDryingDay,HC1_FloorPavementDryingDay: HC1's current day of floor pavement drying,,,b509,0d3800,value,,UCH,,,
[id_sw<=209]r,,,B51000HcDisableMonitor,B51000CHDisableMonitor: copy of the M12 byte of the B5 10 00 service containing the disable bits,,,b509,0d8e00,value,,UCH,,,
[id_sw>=210]r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
[id_sw>=210]r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
[id_sw>=210]r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (leftmost bit 0, rightmost bit 7)",,,b509,0d6700,value,,UCH,,,
[id_sw>=210]r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (leftmost bit 0, rightmost bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
[id_sw>=126]r,,,AssertFileName,AssertFileName,,,b509,0da000,value,,STR:10,,,"shows, if assert is enabled, the name of the module where the 'assert fail' occured"
[id_sw>=126]r,,,AssertLineNumber,AssertLineNumber: assert fail occured in this line,,,b509,0da100,value,,UIN,,,
[id_sw>=126]r,,,Actostorstate,actostorstate: state of the actoSTOR control (0 = off; 1 = DHW released; 2 = DHW loading; 3 = Pump overrun; 4 = stop pump overrun),,,b509,0da400,value,,UCH,,,
[id_sw>=208]r,,,V430PluggedIn,V430_PluggedIn: false if calorMATIC 430 is set inside a wall socket and not plugged in,,,b509,0db300,value,,UCH,0=off;1=on,,
r,,,DisplayedRoomTemp,DisplayedRoomTemp: displayed room temperature,,,b509,0d8000,value,,D2C,,°C,temperature
r,,,RoomTemp,RaumtemperaturIst: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,OutsideTemp,OutsideTempSensor: current outdoor temperature and sensorstate,,,b509,0d6200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0d5f00,value,,BDY,,,weekday
w,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0e5f00,value,,BDY,,,weekday
r,,,Time,current time,,,b509,0d6000,value,,VTI,,,time
w,,,Time,current time,,,b509,0e6000,value,,VTI,,,time
r,,,Date,current date,,,b509,0d6100,value,,HDA:3,,,date
w,,,Date,current date,,,b509,0e6100,value,,HDA:3,,,date
r,,,StatusDcf,StatusDcf: status of the DCF signal (0x00 = no DCF-Signal detected / no RTC value; 0x01 = DCF-signal detected; 0x02 = DCF-signal is being interpreted; 0x03 = DCF-data valid; 0x04 = RTC-data is valid),,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF receiver state
r,,,IsInHoliday,Holiday function active: holidays active,,,b509,0d0b00,value,,UCH,0=no;1=yes,,
r,,,Hc1OPMode,HC1_OPMode,,,b509,0d2f00,value,,UCH,0=off;1=manual;2=auto,,operation mode of the first heating circuit
w,,,Hc1OPMode,HC1_OPMode,,,b509,0e2f00,value,,UCH,0=off;1=manual;2=auto,,operation mode of the first heating circuit
r,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0d3000,value,,D1C,,°C,temperature
w,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0e3000,value,,D1C,,°C,temperature
r,,,Hc1HeatCurve,HC1_HeatCurve: heating curve of the first heating circuit,,,b509,0d3100,value,,UIN,100,,Heating curve
w,,,Hc1HeatCurve,HC1_HeatCurve: heating curve of the first heating circuit,,,b509,0e3100,value,,UIN,100,,Heating curve
r,,,Hc1ManualOPRoomTempDesired,HC1_ManualOPRoomSetpoint: room setpoint in operation mode manual of the first heating circuit,,,b509,0d3200,value,,D1C,,°C,temperature
w,,,Hc1ManualOPRoomTempDesired,HC1_ManualOPRoomSetpoint: room setpoint in operation mode manual of the first heating circuit,,,b509,0e3200,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoTemp,HC1_QuickVetoTemp: manual override setpoint of the first heating circuit,,,b509,0d3c00,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoActive,HC1_QuickVetoActive: manual override of the first heating circuit enabled,,,b509,0d3d00,value,,UCH,0=no;1=yes,,
r,,,NameHc1,Circuits_Name_HC1,,,b509,0d3f00,value,,STR:10,,,labelling of the first heating circuit
w,,,NameHc1,Circuits_Name_HC1,,,b509,0e3f00,value,,STR:10,,,labelling of the first heating circuit
r,,,NameHc2,Circuits_Name_HC2,,,b509,0d3f08,value,,STR:10,,,labelling of the second heating circuit
w,,,NameHc2,Circuits_Name_HC2,,,b509,0e3f08,value,,STR:10,,,labelling of the second heating circuit
r,,,NameHwc,Circuits_Name_DHW,,,b509,0d3f78,value,,STR:10,,,labelling of the domestic hot water circuit
w,,,NameHwc,Circuits_Name_DHW,,,b509,0e3f78,value,,STR:10,,,labelling of the domestic hot water circuit
r,,,HolidayRoomTemp,"HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,HolidayRoomTemp,"HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,HolidayStartPeriod,HolidayStartPeriod: start date of holidays,,,b509,0d1100,value,,HDA:3,,,date
w,,,HolidayStartPeriod,HolidayStartPeriod: start date of holidays,,,b509,0e1100,value,,HDA:3,,,date
r,,,HolidayEndPeriod,HolidayEndPeriod: end date of holidays,,,b509,0d1200,value,,HDA:3,,,date
w,,,HolidayEndPeriod,HolidayEndPeriod: end date of holidays,,,b509,0e1200,value,,HDA:3,,,date
r,,,HwcOPMode,DHW_OPMode,,,b509,0d4200,value,,UCH,0=off;1=manual;2=auto,,operation mode of the domestic hot water circuit
w,,,HwcOPMode,DHW_OPMode,,,b509,0e4200,value,,UCH,0=off;1=manual;2=auto,,operation mode of the domestic hot water circuit
r,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,temperature
w,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,temperature
r,,,HwcQuickVetoTemp,DHW_QuickVetoTemp: manual override setpoint for the domestic hot water circuit,,,b509,0d4500,value,,D1C,,°C,temperature
r,,,HwcQuickVetoActive,DHW_QuickVetoActive: manual override of the domestic hot water circuit enabled,,,b509,0d4300,value,,UCH,0=no;1=yes,,
r,,,HwcManualOPTempDesired,DHW_ManualOPSetpoint: setpoint of domestic hot water circuit in manual operation mode,,,b509,0d4c00,value,,D1C,,°C,temperature
w,,,HwcManualOPTempDesired,DHW_ManualOPSetpoint: setpoint of domestic hot water circuit in manual operation mode,,,b509,0e4c00,value,,D1C,,°C,temperature
r,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust: enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON),,,b509,0d5300,value,,UCH,0=off;1=on,,
w,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust: enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON),,,b509,0e5300,value,,UCH,0=off;1=on,,
r,,,DisplayedHc1RoomTempDesired,"DisplayedHK1RoomSetpoint: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,temperature
r,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0d5700,value,,SCH,2,K,
w,,install,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0e5700,value,,SCH,2,K,
r,,,OutsideTempOffset,OutDoorTempCorr: outside temperature correction,,,b509,0d5800,value,,SCH,2,K,
w,,install,OutsideTempOffset,OutDoorTempCorr: outside temperature correction,,,b509,0e5800,value,,SCH,2,K,
r,,,FrostOverRideTime,FrostOverRideTime: delay before frost protection is activated,,,b509,0d1a00,value,,UCH,,h,hours
w,,install,FrostOverRideTime,FrostOverRideTime: delay before frost protection is activated,,,b509,0e1a00,value,,UCH,,h,hours
r,,,BaseDisplay,BaseDisplay,,,b509,0d2e00,value,,UCH,0=off;1=HC1;2=HC2,,selection which heating circuit's parameters are shown in the basic display
r,,,Hc1RoomTempSwitchOn,HC1_RoomTempSwitchOn,,,b509,0d3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
w,,install,Hc1RoomTempSwitchOn,HC1_RoomTempSwitchOn,,,b509,0e3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
r,,,Hc1MinimalFlowTempDesired,HC1_MinimalFlowSetpoint: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0d3500,value,,D1C,,°C,temperature
w,,install,Hc1MinimalFlowTempDesired,HC1_MinimalFlowSetpoint: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0e3500,value,,D1C,,°C,temperature
r,,,Hc1HcType,HC1_HCType,,,b509,0d3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
w,,install,Hc1HcType,HC1_HCType,,,b509,0e3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
r,,,Hc1SummerOffset,"HC1_SummerOffset: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0d3b00,value,,D1C,,K,
w,,install,Hc1SummerOffset,"HC1_SummerOffset: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0e3b00,value,,D1C,,K,
r,,,Hc1ActualFlowTempDesired,HC1ActualFlowSetPoint: calculated flow temperature setpoint of the first heating circuit,,,b509,0d3e00,value,,D1C,,°C,temperature
r,,,HwcLoadingOffset,DHW_LoadingOffset: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0d4600,value,,D1C,,K,
w,,install,HwcLoadingOffset,DHW_LoadingOffset: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0e4600,value,,D1C,,K,
r,,,HwcPressLowpostrunningtime,DHW_LP_postrunningtime: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0d4700,value,,UCH,,min,minutes
w,,install,HwcPressLowpostrunningtime,DHW_LP_postrunningtime: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0e4700,value,,UCH,,min,minutes
r,,,HwcParallelLoading,DHW_Parallel_Loading: enable parallel tank loading,,,b509,0d4800,value,,UCH,0=off;1=on,,
w,,install,HwcParallelLoading,DHW_Parallel_Loading: enable parallel tank loading,,,b509,0e4800,value,,UCH,0=off;1=on,,
r,,,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
w,,install,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
r,,,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,time
w,,install,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,time
r,,,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,AutoOffMode,AutoOFF_Mode,,,b509,0d4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
w,,install,AutoOffMode,AutoOFF_Mode,,,b509,0e4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
r,,,ContinuosHeating,"ContinuosHeating: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0d4f00,value,,SCH,,,
w,,install,ContinuosHeating,"ContinuosHeating: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0e4f00,value,,SCH,,,
r,,,PreheatingTime,"PreheatingTime: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0d5000,value,,UIN,,,
w,,install,PreheatingTime,"PreheatingTime: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0e5000,value,,UIN,,,
r,,,PreStopTime,"PreStopTime: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0d5100,value,,UCH,,,
w,,install,PreStopTime,"PreStopTime: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0e5100,value,,UCH,,,
r,,,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0d5200,value,,D1C,,K,
w,,install,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0e5200,value,,D1C,,K,
r,,,PhoneNumber1,aucPhoneNumber_1: first part of the installer's telephone number,,,b509,0d5400,value,,STR:9,,,phone number
r,,,PhoneNumber2,aucPhoneNumber_2: second part of the installer's telephone number,,,b509,0d5408,value,,STR:9,,,phone number
r,,,KeyCodeforConfigMenu,KeyCodeforConfigMenue,,,b509,0d5500,value,,HEX:4,,,code for the installer's menues
w,,install,KeyCodeforConfigMenu,KeyCodeforConfigMenue,,,b509,0e5500,value,,HEX:4,,,code for the installer's menues
r,,,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0d5900,value,,HDA:3,,,date
w,,install,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0e5900,value,,HDA:3,,,date
r,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0d5a00,value,,UCH,,,
w,,install,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0e5a00,value,,UCH,,,
r,,,HcMc1ConfigCPLPAsLP,BKMK1ConfigCPLPAsLP,,,b509,0d7d00,value,,UCH,0=CP;1=LP,,configuration of the VR61 relay-output
w,,install,HcMc1ConfigCPLPAsLP,BKMK1ConfigCPLPAsLP,,,b509,0e7d00,value,,UCH,0=CP;1=LP,,configuration of the VR61 relay-output
r,,,PumpBlockingTimeMax,"MaxPumpBlockingTime: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function",,,b509,0d7e00,value,,UCH,,,
w,,install,PumpBlockingTimeMax,"MaxPumpBlockingTime: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function",,,b509,0e7e00,value,,UCH,,,
r,,,CirPump,CircuPumpRunning: circulation pump's state,,,b509,0d8100,value,,UCH,0=off;1=on,,
r,,,Hc1Pump,HK1PumpState: first heating circuit pump's state,,,b509,0d8200,value,,UCH,0=off;1=on,,
r,,,Hc2HcType,HC2_HCType,,,b509,0d8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
w,,install,Hc2HcType,HC2_HCType,,,b509,0e8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
r,,,HwcActualTempDesired,DHW_ActualDesired_Setpoint: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,temperature
r,,,BMUFlowTempOrVF1,BMU_FlowTempOrVF_1: value of either an externally connected flow temperature sensor or the BMU's internal flow sensor if an external sensor is missing,,,b509,0d8700,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,StartEepromUpdate,StarteEepromAktualisierung: update of the EEPROM is to be started,,,b509,0d0e00,value,,UCH,0=off;1=on,,
r,,,EepromUpdateActive,EepromAktualisierungAktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=off;1=on,,
r,,,RoomTempOffsetSelfWarming,RaumTempOffsetEigenErwaerm: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,temperature
r,,,CountryVariant,"CountryVariant: country variant (0 = west, 1 = east)",,,b509,0d1700,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,ActualRoomTempSetpointHC1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,temperature
r,,,SolModuleDetected,SolarModuleDetected: indicates that a VR68 has been detected,,,b509,0d6c00,value,,UCH,0=no;1=yes,,
r,,,HcMc1Detected,BKMK1Detected: indicates that a VR61 has been detected,,,b509,0d6d00,value,,UCH,0=no;1=yes,,
r,,,HRUDetected,HRUDetected: indicates that an airvent module / a heat recovery unit has been detected,,,b509,0d6e00,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,BMUB51101StorageTemp,BMUB51101_TankTemp: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,temperature
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,0=off;1=on,,
r,,,VF1,VF_1: current external flow temperature and sensorstate,,,b509,0d7600,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,BMUB51101BoilerFlowTemp,BMUB51101_BoilerFlowTemp: current flow temperature inside the BMU,,,b509,0d7700,value,,D1C,,°C,temperature
r,,,EnermanState,"EnermanState: current energy-manager-state (Off = 0, Heating = 1, DHW = 2, DHW pump lag = 3)",,,b509,0d7a00,value,,UCH,,,
r,,,B51000TempDesiredLoadingPump,B51000SetPointLoadingPump: loading pump's setpoint sent via B5 10 00 to the BMU,,,b509,0d7b00,value,,D1C,,,
r,,,HcMc1CPLPState,BKMK1CPLPState: nominal condition of the VR61's circulation or loading pump,,,b509,0d7f00,value,,UCH,0=off;1=on,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,Hc1PumpLast24started,HK1PumpLast24started: first heating circuit's pump has been started during the last 24h,,,b509,0d8400,value,,UCH,0=no;1=yes,,
r,,,FrostProtectStateMonitor,FrostProtectState_Monitor: monitoring of the frost protection's state transition diagram,,,b509,0d8900,value,,UCH,,,
r,,,FrostProtectionRequiredMonitor,FrostProtectionRequired_Monitor: frost protection should be enabled,,,b509,0d8a00,value,,UCH,0=no;1=yes,,
r,,,Hc1PreOrContinuosHeatingActive,HC1PreOrContinuosHeatingActive: preheating or continous heating is active for the first heating circuit,,,b509,0d8b00,value,,UCH,0=no;1=yes,,
r,,,CalculatedKickStopTime,CalculatedKickStopTime: calculated time in between two pump kicks during frostprotection (time depends on outside temperature),,,b509,0d8c00,value,,UCH,,min,minutes
r,,,B51000FlowSetMonitor,B51000FlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,°C,temperature
r,,,FrostProtectDelayMonitor,FrostProtectDelayMonitor: frost protection delay has not elapsed yet,,,b509,0d8f00,value,,UCH,0=no;1=yes,,
r,,,ChimneySweepModeActive,ChimneySweepModeActive: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,PumpEnergySaveStateMonitor,PumpEnergySaveStateMonitor: monitoring of the pump energy saving's state transition diagram,,,b509,0d9100,value,,UCH,,,
r,,,PumpEnergySaveCalculatedTimeMonitor,PumpEnergySaveCalculatedTimeMonitor: calculated time for the heating circuit's pump's switch off time during pump energy saving function (depends on outside temperature),,,b509,0d9200,value,,UCH,,min,minutes
r,,,HwcLoadingIn430Active,DHWLoadingIn430Active: DHW-loading is active in non parallel loading cases,,,b509,0d9300,value,,UCH,0=no;1=yes,,
r,,,ActoSTOROPMode,actoSTOR_OPMode: Zustands-Automat actSTOR Ansteuerung,,,b509,0d9400,value,,UCH,,,
r,,,B50418actDesFlowTemp,B50418actDesFlowTemp: flow temperature setpoint calculated by actoSTOR (S3 of B5 04 18),,,b509,0d6b00,value,,D1C,,,
r,,,AdpPreHRoomTempDesired,adpPreH_RoomSetpoint,,,b509,0db400,value,,D2C,,°C,temperature
r,,,AdpPreHCurrentRoomTemp,adpPreH_CurrentRoomTemp,,,b509,0db500,value,,D2C,,°C,temperature
r,,,AdpPreHMinutesBeforeFirstTW,adpPreH_MinutesBeforeFirstTW,,,b509,0db600,value,,UIN,,s,seconds
r,,,AdpPreHPreheatingTime,adpPreH_PreheatingTime,,,b509,0db700,value,,UIN,,min,minutes
r,,,AdpPreHOutdoorTemp,adpPreH_OutdoorTemp,,,b509,0db800,value,,D2C,,°C,temperature
r,,,AdpPreHInSideTW,adpPreH_InSideTW,,,b509,0db900,value,,UCH,0=off;1=on,,
r,,,AdpPreHOutdoorTempStart,adpPreH_OutdoorTempStart,,,b509,0dba00,value,,D2C,,°C,temperature
r,,,AdpPreHRamp,adpPreH_Ramp,,,b509,0dbb00,value,,UIN,,,
r,,,AdpPreHStarttime,adpPreH_Starttime,,,b509,0dbc00,value,,UIN,,s,seconds
r,,,AdpPreHRoomTempStart,adpPreH_RoomTempStart,,,b509,0dbd00,value,,D2C,,°C,temperature
r,,,AdpPreHActive,adpPreH_Active,,,b509,0dbe00,value,,UCH,0=off;1=on,,
r,,,CcTimer_Monday,Periods Monday,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Monday,Periods Monday,,,b515,0002,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Friday,Periods Friday,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Friday,Periods Friday,,,b515,0402,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Monday,Periods Monday,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Monday,Periods Monday,,,b515,0001,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Friday,Periods Friday,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Friday,Periods Friday,,,b515,0401,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,
r,,,HcTimer_Monday,Periods Monday,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Monday,Periods Monday,,,b515,0000,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Friday,Periods Friday,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Friday,Periods Friday,,,b515,0400,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Setpoints_Monday,Temperatures Monday,,,b504,1901,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Monday,Temperatures Monday,,,b505,2e01,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Tuesday,Temperatures Tuesday,,,b504,1902,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Tuesday,Temperatures Tuesday,,,b505,2e02,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Wednesday,Temperatures Wednesday,,,b504,1903,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Wednesday,Temperatures Wednesday,,,b505,2e03,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Thursday,Temperatures Thursday,,,b504,1904,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Thursday,Temperatures Thursday,,,b505,2e04,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Friday,Temperatures Friday,,,b504,1905,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Friday,Temperatures Friday,,,b505,2e05,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Saturday,Temperatures Saturday,,,b504,1906,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Saturday,Temperatures Saturday,,,b505,2e06,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
r,,,Setpoints_Sunday,Temperatures Sunday,,,b504,1907,value,,IGN:1,,,,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature
w,,,Setpoints_Sunday,Temperatures Sunday,,,b505,2e07,temp,,D1C,,°C,temperature,temp_1,,D1C,,°C,temperature,temp_2,,D1C,,°C,temperature