-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path15.470.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
253 lines (253 loc) · 39.7 KB
/
15.470.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
r,,,ActualWeekday,ActualWeekday: current day of week,,,b509,0d5f00,value,,BDY,,,weekday
r,,,Date,current date,,,b509,0d6100,value,,HDA:3,,,date
w,,,Date,current date,,,b509,0e6100,value,,HDA:3,,,date
r,,,Time,current time,,,b509,0d6000,value,,VTI,,,time
w,,,Time,current time,,,b509,0e6000,value,,VTI,,,time
r,,,RoomTemp,RaumtemperaturIst: raw value current room temperature and sensorstate (without any correction),,,b509,0d0000,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0d5700,value,,SCH,2,K,
w,,,RoomTempCorrection,RoomTempCorrection: room temperature correction,,,b509,0e5700,value,,SCH,2,K,
r,,,OutsideTemp,OutsideTempSensor: current outdoor temperature and sensorstate,,,b509,0d6200,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,OutsideTempOffset,OutDoorTempCorr: outside temperature correction,,,b509,0d5800,value,,SCH,2,K,
w,,,OutsideTempOffset,OutDoorTempCorr: outside temperature correction,,,b509,0e5800,value,,SCH,2,K,
r,,,DisplayedHc1RoomTempDesired,"DisplayedHK1RoomSetpoint: 0= >5°C, currently displayed room temperature setpoint",,,b509,0d9600,value,,D1C,,°C,temperature
r,,,Hc1OPMode,HC1_OPMode,,,b509,0d2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
w,,,Hc1OPMode,HC1_OPMode,,,b509,0e2f00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the first heating circuit
r,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0d2700,value,,D1C,,°C,temperature
w,,,Hc1DayTemp,HC1_DaySetTemp: day setpoint,,,b509,0e2700,value,,D1C,,°C,temperature
r,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0d3000,value,,D1C,,°C,temperature
w,,,Hc1NightTemp,HC1_NightSetTemp: lowering temperature setpoint of the first heating circuit,,,b509,0e3000,value,,D1C,,°C,temperature
r,,,Hc1QuickVetoTemp,HC1_QuickVetoTemp: manual override setpoint of the first heating circuit,,,b509,0d3c00,value,,D1C,,°C,temperature
r,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0d4000,value,,D1C,,,
w,,,Hc1HolidayRoomTemp,"HC1_HolidayRoomSetTemp: 4.5=frostprotect, room setpoint during holidays",,,b509,0e4000,value,,D1C,,,
r,,,Hc1SFMode,HC1_SFMode,,,b509,0d5d00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of first heating circuit
r,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0d1100,value,,HDA:3,,,date
w,,,Hc1HolidayStartPeriod,HC1HolidayStartPeriod: first heating circuit's start date of holidays,,,b509,0e1100,value,,HDA:3,,,date
r,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0d1200,value,,HDA:3,,,date
w,,,Hc1HolidayEndPeriod,HC1HolidayEndPeriod: first heating circuit's end date of holidays,,,b509,0e1200,value,,HDA:3,,,date
r,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0d2100,value,,HDA:3,,,date
w,,,Hc1BankHolidayStartPeriod,HC1BankHolidayStartPeriod: first heating circuit's start date of bank holidays,,,b509,0e2100,value,,HDA:3,,,date
r,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0d2200,value,,HDA:3,,,date
w,,,Hc1BankHolidayEndPeriod,HC1BankHolidayEndPeriod: first heating circuit's end date of bank holidays,,,b509,0e2200,value,,HDA:3,,,date
r,,,Hc2HolidayStartPeriod,HC2HolidayStartPeriod: second heating circuit's start date of holidays,,,b509,0d2300,value,,HDA:3,,,date
w,,,Hc2HolidayStartPeriod,HC2HolidayStartPeriod: second heating circuit's start date of holidays,,,b509,0e2300,value,,HDA:3,,,date
r,,,Hc2HolidayEndPeriod,HC2HolidayEndPeriod: second heating circuit's end date of holidays,,,b509,0d2400,value,,HDA:3,,,date
w,,,Hc2HolidayEndPeriod,HC2HolidayEndPeriod: second heating circuit's end date of holidays,,,b509,0e2400,value,,HDA:3,,,date
r,,,Hc2BankHolidayStartPeriod,HC2BankHolidayStartPeriod: second heating circuit's start date of bank holidays,,,b509,0d2500,value,,HDA:3,,,date
w,,,Hc2BankHolidayStartPeriod,HC2BankHolidayStartPeriod: second heating circuit's start date of bank holidays,,,b509,0e2500,value,,HDA:3,,,date
r,,,Hc2BankHolidayEndPeriod,HC2BankHolidayEndPeriod: second heating circuit's end date of bank holidays,,,b509,0d2600,value,,HDA:3,,,date
w,,,Hc2BankHolidayEndPeriod,HC2BankHolidayEndPeriod: second heating circuit's end date of bank holidays,,,b509,0e2600,value,,HDA:3,,,date
r,,,Hc2SFMode,HC2_SFMode,,,b509,0d1c00,value,,UCH,0=none;1=party;2=onedaybankholiday;3=onedayholiday;4=holiday;5=bankholiday;6=quickveto;7=onetimeventilation;8=onetimewater,,activated special function of second heating circuit
r,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0d4400,value,,D1C,,°C,temperature
w,,,HwcTempDesired,DHW_DesiredTemp: setpoint of domestic hot water circuit,,,b509,0e4400,value,,D1C,,°C,temperature
r,,,HcName1,"aaucHcNames_HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0d3f00,value,,STR:11,,,heat circuit name
w,,,HcName1,"aaucHcNames_HK1: labelling of the first heating circuit (only A-Z,0-9,blank)",,,b509,0e3f00,value,,STR:11,,,heat circuit name
r,,,HcName2,"aaucHcNames_HK2: labelling of the second heating circuit (only A-Z,0-9,blank)",,,b509,0d3f08,value,,STR:11,,,heat circuit name
w,,,HcName2,"aaucHcNames_HK2: labelling of the second heating circuit (only A-Z,0-9,blank)",,,b509,0e3f08,value,,STR:11,,,heat circuit name
r,,,ContactName,aucContactName,,,b509,0db400,value,,STR:13,,,"installer's name (only A-Z,0-9,blank)"
w,,install,ContactName,aucContactName,,,b509,0eb400,value,,STR:13,,,"installer's name (only A-Z,0-9,blank)"
r,,,PhoneNumber,aucPhoneNumber,,,b509,0d5400,value,,STR:13,,,"installer's telephone number (only 0-9,-,blank)"
w,,install,PhoneNumber,aucPhoneNumber,,,b509,0e5400,value,,STR:13,,,"installer's telephone number (only 0-9,-,blank)"
r,,,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0d5900,value,,HDA:3,,,date
w,,install,MaintenanceDate,MaintenanceDate: date of the next maintenance service,,,b509,0e5900,value,,HDA:3,,,date
r,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0d5a00,value,,UCH,,,
w,,,LcdContrastValue,LcdContrastValue: setting of the LCD contrast,,,b509,0e5a00,value,,UCH,,,
r,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust,,,b509,0d5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
w,,,SummerWinterTimeAdjust,SummerWinterTimeAdjust,,,b509,0e5300,value,,UCH,0=off;1=auto,,enable automatic switching over to daylight saving's time (when a DCF receiver is connected to the BMU the value is set fix to ON)
r,,,LanguageVariant,LanguageVariant,,,b509,0d1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
w,,,LanguageVariant,LanguageVariant,,,b509,0e1600,value,,UCH,0=german;1=english;2=french;3=italian;4=danish;5=dutch;6=spanish;7=turkish;8=hungarian;9=russian;10=ukrainian;11=estonian;12=latvian;13=lithuanian;14=swedish;15=norwegian;16=polish;17=czech;18=croatian;19=slovakian;20=romanian;21=slovenian;22=serbian,,display language
r,,,BMUFlowTempOrVF1,BMU_FlowTempOrVF_1: value of either an externally connected flow temperature sensor or the BMU's internal flow sensor if an external sensor is missing,,,b509,0d8700,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,RoomTempOffsetSelfWarming,RaumTempOffsetEigenErwaerm: room temperature intrinsic heating offset,,,b509,0d1500,value,,D2C,,°C,temperature
r,,,OpModeEffect,OpModeEffect,,,b509,0db800,value,,UCH,0=HC1;1=HC2;3=HC1_HC2,,selection which heating circuit is affected by changing parameters in the basic display
w,,install,OpModeEffect,OpModeEffect,,,b509,0eb800,value,,UCH,0=HC1;1=HC2;3=HC1_HC2,,selection which heating circuit is affected by changing parameters in the basic display
r,,,HydraulicSwitch,HydraulicSwitch: hydraulic switch is installed,,,b509,0db700,value,,UCH,0=no;1=yes,,
w,,install,HydraulicSwitch,HydraulicSwitch: hydraulic switch is installed,,,b509,0eb700,value,,UCH,0=no;1=yes,,
r,,,HcMc1ConfigCPLP,BKMK1ConfigCPLP,,,b509,0d7d00,value,,UCH,0=off;1=CP;2=LP,,configuration of the VR61 relay-output
w,,install,HcMc1ConfigCPLP,BKMK1ConfigCPLP,,,b509,0e7d00,value,,UCH,0=off;1=CP;2=LP,,configuration of the VR61 relay-output
r,,,CirPump,CircuPumpRunning: circulation pump's state,,,b509,0d8100,value,,UCH,0=no;1=yes,,
r,,,Hc1HcType,HC1_HCType,,,b509,0d3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
w,,install,Hc1HcType,HC1_HCType,,,b509,0e3a00,value,,UCH,0=disabled;1=burnercircuit,,type of the first heating circuit
r,,,Hc1HeatCurve,HC1_HeatCurve: heating curve of the first heating circuit,,,b509,0d3100,value,,UIN,100,,Heating curve
w,,install,Hc1HeatCurve,HC1_HeatCurve: heating curve of the first heating circuit,,,b509,0e3100,value,,UIN,100,,Heating curve
r,,,Hc1RoomTempSwitchOn,HC1_RoomTempSwitchOn,,,b509,0d3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
w,,install,Hc1RoomTempSwitchOn,HC1_RoomTempSwitchOn,,,b509,0e3400,value,,UCH,0=off;1=modulating;2=thermostat,,room temperature modulation of the first heating circuit
r,,,Hc1SummerOffset,"HC1_SummerOffset: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0d3b00,value,,SCH,2,K,
w,,install,Hc1SummerOffset,"HC1_SummerOffset: summer offset of the first heating circuit (if outside temperature > room setpoint + summer offset => heating is OFF;applies to comfort and night setback setpoint; no influence if room temperature modulation is set to ""thermostat"")",,,b509,0e3b00,value,,SCH,2,K,
r,,,Hc1MinimalFlowTempDesired,HC1_MinimalFlowSetpoint: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0d3500,value,,D1C,,°C,temperature
w,,install,Hc1MinimalFlowTempDesired,HC1_MinimalFlowSetpoint: minimum flow temperature setpoint (end emphasis) of the first heating circuit,,,b509,0e3500,value,,D1C,,°C,temperature
r,,,Hc1AutoOffMode,HC1_AutoOFF_Mode,,,b509,0d4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
w,,install,Hc1AutoOffMode,HC1_AutoOFF_Mode,,,b509,0e4d00,value,,UCH,0=frostprotection;1=lowering;2=eco,,operation during the lowering time
r,,,Hc1ActualFlowTempDesired,HC1ActualFlowSetPoint: current flow temperature setpoint of the first heating circuit,,,b509,0d3e00,value,,D1C,,°C,temperature
r,,,Hc1FloorPavementDryingTemp,HC1_FloorPavementDryingTemperature: HC1's current flow temperature setpoint with activated floor pavement drying,,,b509,0d2a00,value,,D1C,,°C,temperature
r,,,Hc1FloorPavementDryingDay,HC1_FloorPavementDryingDay: HC1's current day of floor pavement drying,,,b509,0d3800,value,,UCH,,,
w,,install,Hc1FloorPavementDryingDay,HC1_FloorPavementDryingDay: HC1's current day of floor pavement drying,,,b509,0e3800,value,,UCH,,,
r,,,Hc2HcType,HC2_HCType,,,b509,0d8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
w,,install,Hc2HcType,HC2_HCType,,,b509,0e8500,value,,UCH,0=disabled;1=mixing;2=zone,,type of the second heating circuit
r,,,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0d4b00,value,,UCH,0=no;1=yes,,
w,,install,HwcCircuitActive,DHW_CircuitActive: domestic hot water circuit is enabled,,,b509,0e4b00,value,,UCH,0=no;1=yes,,
r,,,HwcParallelLoading,DHW_Parallel_Loading: enable parallel tank loading,,,b509,0d4800,value,,UCH,0=off;1=on,,
r,,,HwcLoadingOffset,DHW_LoadingOffset: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0d4600,value,,D1C,,K,
w,,install,HwcLoadingOffset,DHW_LoadingOffset: flow temperature's tank loading offset (flow setpoint of the DHW circuit = DHW setpoint + flow temperature's tank loading offset; only relevant if DHW control is done by control),,,b509,0e4600,value,,D1C,,K,
r,,,HwcPressLowpostrunningtime,DHW_LP_postrunningtime: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0d4700,value,,UCH,,min,minutes
w,,install,HwcPressLowpostrunningtime,DHW_LP_postrunningtime: duration of the tank loading pump's lag (only relevant if DHW control is done by control),,,b509,0e4700,value,,UCH,,min,minutes
r,,,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0d4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
w,,install,HwcLegioStartDay,DHW_LegioStartDay,,,b509,0e4900,value,,UCH,0=Mon;1=Tue;2=Wed;3=Thu;4=Fri;5=Sat;6=Sun;7=off;8=Mon_Sun,,weekday on which legionella protection is started (may also be every day of the week)
r,,,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0d4a00,value,,VTI,,,time
w,,install,HwcLegioStartTime,DHW_LegioStartTime: time on which legionella protection is started,,,b509,0e4a00,value,,VTI,,,time
r,,,DisplayedHwcStorageTemp,DisplayedDHWTankTemperature: display of the storage's temperature (also in case of an SP1error),,,b509,0d9e00,value,,D1C,,°C,temperature
r,,,HwcActualTempDesired,DHW_ActualDesired_Setpoint: current domestic hot water setpoint,,,b509,0d8600,value,,D1C,,°C,temperature
r,,,FrostOverRideTime,FrostOverRideTime: delay before frost protection is activated,,,b509,0d1a00,value,,UCH,,h,hours
w,,install,FrostOverRideTime,FrostOverRideTime: delay before frost protection is activated,,,b509,0e1a00,value,,UCH,,h,hours
r,,,ContinuosHeating,"ContinuosHeating: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0d4f00,value,,SCH,,,
w,,install,ContinuosHeating,"ContinuosHeating: -26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)",,,b509,0e4f00,value,,SCH,,,
r,,,PreheatingTime,"PreheatingTime: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0d5000,value,,UIN,,,
w,,install,PreheatingTime,"PreheatingTime: in steps of 10, maximum time of enabling the heating before the heating time window starts",,,b509,0e5000,value,,UIN,,,
r,,,PreStopTime,"PreStopTime: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0d5100,value,,UCH,,,
w,,install,PreStopTime,"PreStopTime: in steps of 10, maximum time of starting the lowering operation before the heating time window ends",,,b509,0e5100,value,,UCH,,,
r,,,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0d5200,value,,D1C,,K,
w,,install,ExcessTemp,ExcessTemperature: excess temperature (flow temperature's setpoint is increased by this value to keep the mixing valve in its control range),,,b509,0e5200,value,,D1C,,K,
r,,,PumpBlockingTimeMax,"MaxPumpBlockingTime: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function (0 <=> Off; value range only 5-60 min)",,,b509,0d7e00,value,,UCH,,,
w,,install,PumpBlockingTimeMax,"MaxPumpBlockingTime: 0=off, heating circuit pump's maximum blocking time for pump's energy saving function (0 <=> Off; value range only 5-60 min)",,,b509,0e7e00,value,,UCH,,,
r,,,KeyCodeforConfigMenu,KeyCodeforConfigMenue: code for the installer's menues,,,b509,0d5500,value,,PIN,,,
w,,install,KeyCodeforConfigMenu,KeyCodeforConfigMenue: code for the installer's menues,,,b509,0e5500,value,,PIN,,,
r,,,GlobalSystemOff,"GlobalSystemOFF: Set to TRUE if ""System Off"" is selected",,,b509,0d0100,value,,UCH,0=off;1=on,,
r,,,StatusDcf,StatusDcf,,,b509,0d0200,value,,UCH,0=nosignal;1=ok;2=sync;3=validDCF;4=validRTC,,status of the DCF signal
r,,,DcfIsValid,DcfIsValid: validity of DCF signal,,,b509,0d0400,value,,UCH,0=no;1=yes,,
r,,,HcMc1Detected,BKMK1Detected: indicates that a VR61 has been detected,,,b509,0d6d00,value,,UCH,0=no;1=yes,,
r,,,SolModuleDetected,SolarModuleDetected: indicates that a VR68 has been detected,,,b509,0d6c00,value,,UCH,0=no;1=yes,,
r,,,ACTOstorDetected,ACTOstorDetected: indicates that an ACTOstor has been detected,,,b509,0d6f00,value,,UCH,0=no;1=yes,,
r,,,VR81Detected,VR81Detected: indicates that a VR81 has been detected,,,b509,0d7400,value,,UCH,0=no;1=yes,,
r,,,ASCDetected,ASCDetected: indicates that a VMS has been detected,,,b509,0dbb00,value,,UCH,0=no;1=yes,,
r,,,VF1,VF_1: current external flow temperature and sensorstate,,,b509,0d7600,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,HydraulicMap,"HydraulicMap: hydraulic map (0 = H1, 3 = H4, 11 = A1, 12 = A2, 14 = A5, 15 = S1, 16 = S3a, 17 = S3b)",,,b509,0d1800,value,,UCH,,,
r,,,ActualRoomTempDesiredHc1,ActualRoomTempSetpointHC1: current room setpoint considering all basic conditions passed to the control algorithms,,,b509,0d6300,value,,D2C,,°C,temperature
r,,,Hc2OPMode,HC2_OPMode,,,b509,0d1b00,value,,UCH,2=auto;3=on;4=night;5=summer,,operation mode of the second heating circuit
r,,,Hc2TempDesiredB50418,HC2_Desired_TempB50418: current flow temperature setpoint of the second heating circuit,,,b509,0d3200,value,,D1C,,°C,temperature
r,,,B51000M7OpModeMonitor,"B51000M7OpModeMonitor: operation mode sent via B5 10 00 (0 = auto, 1 = forced off, 2 = forced CH, 3 = forced DHW)",,,b509,0d6500,value,,UCH,,,
r,,,B51000M8HeatFlowSetMonitor,B51000M8HeatFlowSetMonitor: flow temperature setpoint sent via B5 10 00 to the BMU,,,b509,0d8d00,value,,D1C,,,
r,,,B51000M9TappingSetMon,B51000M9TappingSetMon: DHW setpoint without loading offset (for hydraulic map H1),,,b509,0d5600,value,,D1C,,,
r,,,B51000M10HwcFlowSetMon,B51000M10DHWFlowSetMon: flow setpoint DHW sent via B5 10 00,,,b509,0d6600,value,,UCH,,,
r,,,B51000M12DisableBitsMon,"B51000M12DisableBitsMon: bits 0-7: disable CH/disable DHW tapping/disable DHW tank loading/not used/clear burner blocking DHW/dis, disable bits sent via B5 10 00 (left bit 0, right bit 7)",,,b509,0d6700,value,,UCH,,,
r,,,B51000M14Monitor,"B51000M14Monitor: bits 0-7: remote control CH pump/release backup heater/release cooling/not used/left stop position DHW o, bits sent in M14 of B5 10 00 (left bit 0, right bit 7; relevant is bit 0: remote control of CH pump)",,,b509,0d6800,value,,UCH,,,
r,,,TestVarActivateFunction,TestVarActivateFunction: 0=All SF_OFF11/2=1DayHolON/OFF13/4=1DayBankON/OFF15/6=1DayHolON/OFF27/8=1DayBankON/OFF29/10=1xDHWLoadON/OFF11/12=QVetoON/OFF113/14=QVetoON/OFF215/16=PartyON/OFF117/18=PartyON/OFF219/20=Ventil.ON/OFF121/22=Ventil.ON/OFF223/24=SystemOff_ON/OFF,,,b509,0d0b00,value,,UCH,,,
r,,,HwcOPMode,DHW_OPMode,,,b509,0d4200,value,,UCH,0=off;1=on;2=auto;3=autosunday;4=party;5=load;7=holiday,,operation mode of the domestic hot water circuit set implicitly
r,,,BMUB51101HwcState,BMUB51101_DHWState: flame is on because of either tapping or tank loading,,,b509,0d7500,value,,UCH,,,
r,,,B51000TempDesiredLoadingPump,B51000SetPointLoadingPump: loading pump's setpoint sent via B5 10 00 to the BMU,,,b509,0d7b00,value,,D1C,,,
r,,,BMUB51101BoilerFlowTemp,BMUB51101_BoilerFlowTemp: current flow temperature inside the BMU,,,b509,0d7700,value,,D1C,,°C,temperature
r,,,BMUB51101StorageTemp,BMUB51101_TankTemp: hot water storage temperature received via eBUS service B5 11 01,,,b509,0d7100,value,,D1C,,°C,temperature
r,,,BMUB51101ErrorStatus,BMUB51101_ErrorStatus: error state of BMU received via eBUS service B51101,,,b509,0d7000,value,,UCH,,,
r,,,StartEepromUpdate,StarteEepromAktualisierung: update of the EEPROM has to be started,,,b509,0d0e00,value,,UCH,0=no;1=yes,,
r,,,EepromUpdateActive,EepromAktualisierungAktiv: update of the EEPROM has been started,,,b509,0d0f00,value,,UCH,0=no;1=yes,,
r,,,Hc1PreOrContinuosHeatingActive,HC1PreOrContinuosHeatingActive: preheating or continous heating is active for the first heating circuit,,,b509,0d8b00,value,,UCH,0=no;1=yes,,
r,,,Hc1PreCutOffActive,HC1_PreCutOffActive: early cut off is active for the first heating circuit,,,b509,0d4100,value,,UCH,0=no;1=yes,,
r,,,Hc2HolidayPeriodIsActive,HC2HolidayPeriodIsActive: calculated by 470 and sent to VR61,,,b509,0d0c00,value,,UCH,0=no;1=yes,,
r,,,Hc2BankHolidayPeriodIsActive,HC2BankHolidayPeriodIsActive: calculated by 470 and sent to VR61,,,b509,0d0d00,value,,UCH,0=no;1=yes,,
r,,,ChimneySweepModeActive,ChimneySweepModeActive: chimney sweep mode has been enabled by the BMU,,,b509,0d9000,value,,UCH,0=no;1=yes,,
r,,,HwcLoadingIn430Active,DHWLoadingIn430Active: DHW-loading is active in non parallel loading cases,,,b509,0d9300,value,,UCH,0=no;1=yes,,
r,,,LegioProtectActive,LegioProtectActive: legionella protection is active,,,b509,0d7300,value,,UCH,0=no;1=yes,,
r,,,V430PluggedIn,V430_PluggedIn: false if calorMATIC 470 is set inside a wall socket and not plugged in,,,b509,0db300,value,,UCH,0=no;1=yes,,
r,,,InstallAssistant,"InstallAssistant: install assistant not active (0 = active, 1 = not active)",,,b509,0d5e00,value,,UCH,0=off;1=on,,
r,,,VR81ActiveForHc1,VR81ActiveForHC1: VR81 is connected to the first heating circuit,,,b509,0d5c00,value,,UCH,0=no;1=yes,,
r,,,VR81ActiveForHc2,VR81ActiveForHC2: VR81 is connected to the second heating circuit,,,b509,0da700,value,,UCH,0=no;1=yes,,
r,,,FactoryTestActive,FactoryTestAktiv: Factory Test Pin,,,b509,0d1000,value,,UCH,0=no;1=yes,,
r,,,HcMc1CPLPState,BKMK1CPLPState: nominal condition of the VR61's circulation or loading pump,,,b509,0d7f00,value,,UCH,0=off;1=on,,
r,,,EnermanState,"EnermanState: current energy-manager-state (0 = off, 1 = heating, 2 = DHW, 3 = DHW pump lag)",,,b509,0d7a00,value,,UCH,,,
r,,,Hc1Pump,HK1PumpState: first heating circuit pump's state,,,b509,0d8200,value,,UCH,0=off;1=on,,
r,,,Hc1PumpLast24started,HK1PumpLast24started: first heating circuit's pump has been started during the last 24h,,,b509,0d8400,value,,UCH,0=no;1=yes,,
r,,,CPLPLast24started,CP_LPLast24started: circulation respectively loading pump has been started during the last 24h,,,b509,0d8300,value,,UCH,0=no;1=yes,,
r,,,CalculatedKickStopTime,CalculatedKickStopTime: calculated time in between two pump kicks during frostprotection (time depends on outside temperature),,,b509,0d8c00,value,,UCH,,min,minutes
r,,,FrostProtectStateMonitor,FrostProtectState_Monitor: monitoring of the frost protection's state transition diagram,,,b509,0d8900,value,,UCH,,,
r,,,FrostProtectionRequiredMonitor,FrostProtectionRequired_Monitor: frost protection should be enabled,,,b509,0d8a00,value,,UCH,0=no;1=yes,,
r,,,FrostProtectDelayMonitor,FrostProtectDelayMonitor: frost protection delay has not elapsed yet,,,b509,0d8f00,value,,UCH,0=no;1=yes,,
r,,,PumpEnergySaveStateMonitor,PumpEnergySaveStateMonitor: monitoring of the pump energy saving's state transition diagram,,,b509,0d9100,value,,UCH,,,
r,,,PumpEnergySaveCalculatedTimeMonitor,PumpEnergySaveCalculatedTimeMonitor: calculated time for the heating circuit's pump's switch off time during pump energy saving function (depends on outside temperature),,,b509,0d9200,value,,UCH,,min,minutes
r,,,ActoSTOROPMode,actoSTOR_OPMode: state diagram actoSTOR control,,,b509,0d9400,value,,UCH,,,
r,,,ClockSwitchSummerWinterDone,ClockSwitchSummerWinterDone: automatic switching over to/from daylight saving's time has been done,,,b509,0d7800,value,,UCH,0=no;1=yes,,
r,,,MonitorEEpromInkonsiNumber,MonitorEEpromInkonsiNumber,,,b509,0d9f00,value,,HEX:8,,,identification of the last eight EEPROM inconsistencies
r,,,MonitorCurrentIPart,MonitorCurrent_I_Anteil: current i-control value; updated every 3 minutes,,,b509,0d3300,value,,D2C,,°C,temperature
r,,,CountryVariant,"CountryVariant: country variant (0 = west, 1 = east, 2 = all)",,,b509,0d1700,value,,UCH,,,
r,,,DisplayedRoomTemp,DisplayedRoomTemp: displayed room temperature,,,b509,0d8000,value,,D2C,,°C,temperature
r,,,RaumtempIstUnten,RaumtempIstUnten: lower room temp sensor value,,,b509,0dc100,temp,,D2C,,°C,temperature,sensor,,UCH,0=ok;85=circuit;170=cutoff,,sensor status
r,,,ADCValueTempbelow,ADCValue_T_below: lower room temp sensor ADC value,,,b509,0d4e00,value,,UIN,,,
r,,,MenuTestingCurrScreenCount,MenuTesting_CurrScreenNo,,,b509,0df500,value,,UIN,,,
r,,,MenuTestingCurrValue,MenuTesting_CurrValue,,,b509,0df600,value,,ULG,,,
r,,,MenuTestingSymAddrFromCurrValue,MenuTesting_SymAddrFromCurrValue,,,b509,0df700,value,,UIN,,,
r,,,MenuTestingCurrPid,MenuTesting_CurrPid,,,b509,0df800,value,,UIN,,,
r,,,MenuTestingCurrParameterTextId,MenuTesting_CurrParameterTextId,,,b509,0df900,value,,UIN,,,
r9,,,YieldThisYear,yield this year,,,b509,0d3d00:2;0d3d08:2;0d3d10:2;0d3d18:2;0d3d20:2;0d3d28:2;0d3d30:2;0d3d38:2;0d3d40:2;0d3d48:2;0d3d50:2;0d3d58:2,energy,,UIN,,kWh,,energy_1,,UIN,,kWh,,energy_2,,UIN,,kWh,,energy_3,,UIN,,kWh,,energy_4,,UIN,,kWh,,energy_5,,UIN,,kWh,,energy_6,,UIN,,kWh,,energy_7,,UIN,,kWh,,energy_8,,UIN,,kWh,,energy_9,,UIN,,kWh,,energy_10,,UIN,,kWh,,energy_11,,UIN,,kWh,
r,,,YieldLastYear,yield last year,,,b509,0d4300:2;0d4308:2;0d4310:2;0d4318:2;0d4320:2;0d4328:2;0d4330:2;0d4338:2;0d4340:2;0d4348:2;0d4350:2;0d4358:2,energy,,UIN,,kWh,,energy_1,,UIN,,kWh,,energy_2,,UIN,,kWh,,energy_3,,UIN,,kWh,,energy_4,,UIN,,kWh,,energy_5,,UIN,,kWh,,energy_6,,UIN,,kWh,,energy_7,,UIN,,kWh,,energy_8,,UIN,,kWh,,energy_9,,UIN,,kWh,,energy_10,,UIN,,kWh,,energy_11,,UIN,,kWh,
r,,,CcTimer_Monday,Periods Monday,,,b515,0002,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Monday,Periods Monday,,,b515,0002,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Tuesday,Periods Tuesday,,,b515,0102,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Wednesday,Periods Wednesday,,,b515,0202,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Thursday,Periods Thursday,,,b515,0302,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Friday,Periods Friday,,,b515,0402,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Friday,Periods Friday,,,b515,0402,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Saturday,Periods Saturday,,,b515,0502,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CcTimer_Sunday,Periods Sunday,,,b515,0602,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Monday,Periods Monday,,,b515,0001,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Monday,Periods Monday,,,b515,0001,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Tuesday,Periods Tuesday,,,b515,0101,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Wednesday,Periods Wednesday,,,b515,0201,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Thursday,Periods Thursday,,,b515,0301,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Friday,Periods Friday,,,b515,0401,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Friday,Periods Friday,,,b515,0401,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Saturday,Periods Saturday,,,b515,0501,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HwcTimer_Sunday,Periods Sunday,,,b515,0601,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Monday,Periods Monday,,,b515,0000,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Monday,Periods Monday,,,b515,0000,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Tuesday,Periods Tuesday,,,b515,0100,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Wednesday,Periods Wednesday,,,b515,0200,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Thursday,Periods Thursday,,,b515,0300,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Friday,Periods Friday,,,b515,0400,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Friday,Periods Friday,,,b515,0400,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Saturday,Periods Saturday,,,b515,0500,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,HcTimer_Sunday,Periods Sunday,,,b515,0600,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Monday,Periods Monday,,,b515,0003,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Monday,Periods Monday,,,b515,0003,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Tuesday,Periods Tuesday,,,b515,0103,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Tuesday,Periods Tuesday,,,b515,0103,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Wednesday,Periods Wednesday,,,b515,0203,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Wednesday,Periods Wednesday,,,b515,0203,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Thursday,Periods Thursday,,,b515,0303,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Thursday,Periods Thursday,,,b515,0303,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Friday,Periods Friday,,,b515,0403,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Friday,Periods Friday,,,b515,0403,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Saturday,Periods Saturday,,,b515,0503,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Saturday,Periods Saturday,,,b515,0503,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,CoolingTimer_Sunday,Periods Sunday,,,b515,0603,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,CoolingTimer_Sunday,Periods Sunday,,,b515,0603,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Monday,Periods Monday,,,b515,0004,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Monday,Periods Monday,,,b515,0004,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Tuesday,Periods Tuesday,,,b515,0104,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Tuesday,Periods Tuesday,,,b515,0104,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Wednesday,Periods Wednesday,,,b515,0204,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Wednesday,Periods Wednesday,,,b515,0204,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Thursday,Periods Thursday,,,b515,0304,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Thursday,Periods Thursday,,,b515,0304,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Friday,Periods Friday,,,b515,0404,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Friday,Periods Friday,,,b515,0404,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Saturday,Periods Saturday,,,b515,0504,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Saturday,Periods Saturday,,,b515,0504,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,TariffTimer_Sunday,Periods Sunday,,,b515,0604,value,,IGN:1,,,,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,TariffTimer_Sunday,Periods Sunday,,,b515,0604,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,