type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*r,
*w,
*[id_sw],scan,,,,SW
[id_sw>=337]r,,,LegioProtectionDay,"LegioProtectionDay: Legionella protection day (0-6:mo-so, 7:off). Displayed as abbreviations. Additional parameter has to be set for activation or deactivation.",,,b509,0d7c01,value,,BDY,,,weekday
[id_sw>=337]w,,install,LegioProtectionDay,"LegioProtectionDay: Legionella protection day (0-6:mo-so, 7:off). Displayed as abbreviations. Additional parameter has to be set for activation or deactivation.",,,b509,0e7c01,value,,BDY,,,weekday
[id_sw>=407]r,,,Hc1PumpSpeedLayeredStorage,CH1P_PumpSpeed_layered_tank: CH pump speed setpoint while shiftloading DHW tank [%],,,b509,0dc101,value,,UCH,,%,
[id_sw>=407]w,,install,Hc1PumpSpeedLayeredStorage,CH1P_PumpSpeed_layered_tank: CH pump speed setpoint while shiftloading DHW tank [%],,,b509,0ec101,value,,UCH,,%,
[id_sw>=407]r,,,Hc1PumpSpeedCoilStorage,CH1P_PumpSpeed_coil_tank: CH pump speed setpoint while loading DHW tank with coils [%],,,b509,0dc201,value,,UCH,,%,
[id_sw>=407]w,,install,Hc1PumpSpeedCoilStorage,CH1P_PumpSpeed_coil_tank: CH pump speed setpoint while loading DHW tank with coils [%],,,b509,0ec201,value,,UCH,,%,
[id_sw>=407]r,,,HwcStorageIsCoil,DHW_Tank_is_coil: DHW tank is shift loading type if no,,,b509,0dcd01,value,,UCH,0=no;1=yes,,
[id_sw>=407]w,,install,HwcStorageIsCoil,DHW_Tank_is_coil: DHW tank is shift loading type if no,,,b509,0ecd01,value,,UCH,0=no;1=yes,,
[id_sw>=415]r,,,TappingDetectionLimit,"TappingDetectionLimit: turns on backup heater, if temperature drops below this value; 0=function is off",,,b509,0de801,value,,UCH,,,
[id_sw>=415]w,,install,TappingDetectionLimit,"TappingDetectionLimit: turns on backup heater, if temperature drops below this value; 0=function is off",,,b509,0ee801,value,,UCH,,,
r,,,OperatingMode,OperatingMode: Operating mode for the DHWcircuit,,,b509,0d2b00,value,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode
w,,,OperatingMode,OperatingMode: Operating mode for the DHWcircuit,,,b509,0e2b00,value,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode
r,,,StorageTempDesiredStop,Tank_Setpoint_Stop: DHW temperature at which loading stops,,,b509,0d8200,value,,D2C,,°C,temperature
w,,install,StorageTempDesiredStop,Tank_Setpoint_Stop: DHW temperature at which loading stops,,,b509,0e8200,value,,D2C,,°C,temperature
r,,,StorageTempDesiredStart,Tank_Setpoint_Start: DHW temperature at which loading starts,,,b509,0d8300,value,,D2C,,°C,temperature
w,,install,StorageTempDesiredStart,Tank_Setpoint_Start: DHW temperature at which loading starts,,,b509,0e8300,value,,D2C,,°C,temperature
r,,,LegioProtectionEnabled,LegioProtectionEnabled: BMR:enables/disables the anti-legionella feature,,,b509,0d4000,value,,UCH,0=no;1=yes,,
w,,install,LegioProtectionEnabled,LegioProtectionEnabled: BMR:enables/disables the anti-legionella feature,,,b509,0e4000,value,,UCH,0=no;1=yes,,
r,,,LegionellaStartTime,Legionella_Start_Time: start time for legionella protection (different from BMR),,,b509,0d6700,value,,VTM,,,time
w,,install,LegionellaStartTime,Legionella_Start_Time: start time for legionella protection (different from BMR),,,b509,0e6700,value,,VTM,,,time
r,,,DateTime,date/time,,,b504,00,dcfstate,,UCH,0=nosignal;1=ok;2=sync;3=valid,,DCF receiver state,btime,,BTI,,,time,bdate,,BDA,,,date,temp,,D2B,,°C,temperature
r,,,Mode,Operation mode,,,b504,01,temp,,UCH,,°C,temperature,hwcmode,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode,ign,,IGN:2,,,,hwcmode_1,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,mixer type,hex,,HEX,,,,daynight,,UCH,0=night;1=day;7=floorpaving,,day/night mode
w,,,SetTempDesired,Set desired temperature,,,b505,01,value,,UCH,,°C,temperature
w,,,SetMode,Set operation mode,,,b505,02,value,,UCH,0=disabled;1=on;2=off;3=auto,,hot water mode
w,,,SetFlowTempMin,Set min flow temperature,,,b505,0e,value,,UCH,,°C,temperature
w,,,SetFlowTempMax,Set max flow temperature,,,b505,0f,value,,UCH,,°C,temperature
r,,,Params,Parameters,,,b504,09,temp,,UCH,,°C,temperature,ign,,IGN:3,,,,mctype,,BI0:7,0=inactive;1=mixer;2=fixed;3=hwc;4=returnincr;5=pool;6=circulation,,mixer type,temps,,SCH,,°C,temperature,ign_1,,IGN,,,,temps_1,,SCH,,°C,temperature,temps_2,,SCH,,°C,temperature,ign_2,,IGN,,,
r,,,Status0a,Status flow temperature/mixer/pump/desired flow temperature,,,b504,0a,flowtemp,,D2C,,°C,temperature,mixer,,UCH,0=off;1=open;2=close,,mixer State,pump,,UCH,0=off;1=on,,,onoff,,UCH,0=off;1=on,,,flowtempdesired,,UCH,,°C,temperature
r,,,Status,Desired flow/status/flow/desired temperature,,,b504,0d,temp,,UCH,,°C,temperature,onoff,,UCH,0=off;1=on,,,temp_1,,D2C,,°C,temperature,temp_2,,UCH,,°C,temperature
r,,,Status16,outside temperature,,,b504,16,value,,D2C,,°C,temperature
r,,,Timer_Monday,Periods Monday,,,b504,02,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Monday,Periods Monday,,,b505,0901,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Tuesday,Periods Tuesday,,,b504,03,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Tuesday,Periods Tuesday,,,b505,0902,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Wednesday,Periods Wednesday,,,b504,04,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Wednesday,Periods Wednesday,,,b505,0903,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Thursday,Periods Thursday,,,b504,05,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Thursday,Periods Thursday,,,b505,0904,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Friday,Periods Friday,,,b504,06,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Friday,Periods Friday,,,b505,0905,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Saturday,Periods Saturday,,,b504,07,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Saturday,Periods Saturday,,,b505,0906,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
r,,,Timer_Sunday,Periods Sunday,,,b504,08,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,,Timer_Sunday,Periods Sunday,,,b505,0907,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,from,,TTM,,,from,to,,TTM,,,to,daysel,,UCH,0=selected;1=Mo_Fr;2=Sa_Su;3=Mo_Su,,days
w,,install,Iotest,I/O test,,,b506,02,value,,UCH,0=off;1=coolvalve;2=sourcepump;3=hcpump;4=injector;5=caseheater;6=backup;7=hwchcvalve;8=cirpump;9=sc2pump;10=hc2pump;11=hc2mixeropen;12=hc2mixerclose,,
w,,install,Ioteststop,stop I/O test,,,b506,01,
r,,,Currenterror,Current errors,,,b503,0001,error,,UIN,,,error number,error_1,,UIN,,,error number,error_2,,UIN,,,error number,error_3,,UIN,,,error number,error_4,,UIN,,,error number
r,,,Errorhistory,Error_History,,,b503,0101,index,m,UCH,,,,status,,UCH,,,Status,time,,VTM,,,time,date,,HDA:3,,,date,error,,UIN,,,error number
w,,install,Clearerrorhistory,Clear error history,,,b503,0201,cleared,s,UCH,0=no;1=yes,,
w,,,Party,Quick - party,,,b505,05,value,,UCH,0=off;1=on,,
w,,,Load,quick - hot water tank filling,,,b505,06,value,,UCH,0=off;1=on,,
w,,,Save,Quick - cleaning lady,,,b505,07,value,,TTH,,,