Vaillant VR32 support? #198
Comments
this is not an easy task and related to #109 |
Thank you for you reply, I'll do that. BTW with --latency=100000 the VR32 gets visible. |
@Nuc67UA - I have exactly the same configuration as you (2 x Ecotec heaters in cascade, 1 x Calormatic 630 and 1 x VR32 installed in the 2nd heater). I have some questions: Thanks a lot for your answers! |
Hello,
Is this module supported? I have the following setup: VR630 and two Turbotec boilers cascaded. The first one is connected to the bus directly, the second vis VR32 module. The first boiler is visible, the second seems not. Is there any simple solution around that?
Everything else is just fine!
version: ebusd 3.2.v3.2
update check: revision v3.2-2-g1737636 available, broadcast.csv: newer version available, vaillant/15.ui.csv: newer version available, vaillant/25.vr630.hwc.csv: newer version available, vaillant/bai.0010006101.inc: newer version available, vaillant/broadcast.csv: newer version available, vaillant/errors.inc: newer version available, vaillant/hcmode.inc: newer version available
signal: acquired
symbol rate: 25
max symbol rate: 104
min arbitration micros: 1004
max arbitration micros: 8590
min symbol latency: 4
max symbol latency: 9
reconnects: 0
masters: 3
messages: 745
conditional: 12
poll: 0
update: 10
address 03: master #11
address 08: slave #11, scanned "MF=Vaillant;ID=BAI00;SW=0518;HW=7401", loaded "vaillant/bai.0010006101.inc" ([PROD='']), "vaillant/08.bai.csv"
address 10: master #2
address 15: slave #2, scanned "MF=Vaillant;ID=UI ;SW=0321;HW=6201", loaded "vaillant/15.ui.csv"
address 23: slave, scanned "MF=Vaillant;ID=VR630;SW=0306;HW=6301", loaded "vaillant/23.vr630.cc.csv"
address 25: slave, scanned "MF=Vaillant;ID=VR630;SW=0306;HW=6301", loaded "vaillant/25.vr630.hwc.csv"
address 26: slave, scanned "MF=Vaillant;ID=VR630;SW=0306;HW=6301", loaded "vaillant/26.vr630.hc.csv"
address 31: master #8, ebusd
address 36: slave #8, ebusd
address 50: slave, scanned "MF=Vaillant;ID=VR630;SW=0306;HW=6301", loaded "vaillant/50.vr630.mc.csv"
address 51: slave, scanned "MF=Vaillant;ID=VR630;SW=0306;HW=6301", loaded "vaillant/51.vr630.mc.3.csv"
The text was updated successfully, but these errors were encountered: