Notifications
You must be signed in to change notification settings - Fork 2
/
Copy pathread_evse.py
executable file
·104 lines (96 loc) · 7.38 KB
/
read_evse.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
#!/usr/bin/python3
import sys
import serial
import time
from pymodbus.client.sync import ModbusSerialClient
TOTAL_RUNTIME_REGISTERS = 9
TOTAL_CONFIG_REGISTERS = 18
if (len(sys.argv) < 3):
print("please use /dev/ttyUSBx and slave address (1-255) as argument")
quit()
print("opening {}, address: {} hit CTRL+C to exit".format(sys.argv[1], sys.argv[2]))
serialClient = ModbusSerialClient(method = "rtu", port=sys.argv[1], baudrate=9600, stopbits=1, bytesize=8, timeout=0.3)
serialClient.connect()
cycle=0
failCount=0
try:
while True:
cycle += 1
#print("cycle: {} fails: {}".format(cycle,failCount))
try:
if serialClient.is_socket_open():
if 1==cycle:
rq = serialClient.read_holding_registers(2000,TOTAL_CONFIG_REGISTERS,unit=int(sys.argv[2]))
if TOTAL_CONFIG_REGISTERS == len(rq.registers):
print(" EVSE config:")
print("2000 | default amps [A] : {}".format(rq.registers[0]))
print("2001 | modbus address : {}".format(rq.registers[1]))
print("2002 | minimum amps [A] : {}".format(rq.registers[2]))
print("2003 | analog input config (0=0-5V input, 1,2,...=button): {}".format(rq.registers[3]))
print("2004 | save / not save amps by button : {}".format(rq.registers[4]))
print("2005 | config bits : {}".format(rq.registers[5]))
print(" b0 | enable button (on AN input) for current change : {}".format(rq.registers[5]&1>0))
print(" b1 | stop charging when button pressed : {}".format(rq.registers[5]&2>0))
print(" b2 | pilot ready state LED is not blinking : {}".format(rq.registers[5]&4>0))
print(" b3 | enable charging on STATUS D : {}".format(rq.registers[5]&8>0))
print(" b4 | enable RCD feedback (MCLR pin) : {}".format(rq.registers[5]&16>0))
print(" b5 | autoclear RCD error (short timeout) : {}".format(rq.registers[5]&32>0))
print(" .. | reserved")
print(" b13 | disable EVSE after charge : {}".format(rq.registers[5]&8192>0))
print(" b14 | EVSE is disabled (no charge) : {}".format(rq.registers[5]&16384>0))
print(" b15 | enable bootloader mode : {}".format(rq.registers[5]&32768>0))
print("2006 | reserved : {}".format(rq.registers[6]))
print("2007 | PP detection limit [A] : {}".format(rq.registers[7]))
print("2008 | reserved : {}".format(rq.registers[8]))
print("2009 | bootloader FW revision : {}".format(rq.registers[9]))
print("2010 | amps value 6A [A] : {}".format(rq.registers[10]))
print("2011 | amps value 10A [A] : {}".format(rq.registers[11]))
print("2012 | amps value 16A [A] : {}".format(rq.registers[12]))
print("2013 | amps value 25A [A] : {}".format(rq.registers[13]))
print("2014 | amps value 32A [A] : {}".format(rq.registers[14]))
print("2015 | amps value 48A [A] : {}".format(rq.registers[15]))
print("2016 | amps value 63A [A] : {}".format(rq.registers[16]))
print("2017 | amps value 80A [A] : {}".format(rq.registers[17]))
time.sleep(1)
else:
print("Could not read config ({} registers)".format(TOTAL_CONFIG_REGISTERS))
rq = serialClient.read_holding_registers(1000,TOTAL_RUNTIME_REGISTERS,unit=int(sys.argv[2]))
if TOTAL_RUNTIME_REGISTERS == len(rq.registers):
print("\n EVSE runtime variables:")
print("1000 | actual amps [A] : {}".format(rq.registers[0]))
print("1001 | amps on PWM driver output [A] : {}".format(rq.registers[1]))
print("1002 | vehicle state 1=ready,2=present,3=chg,4=vent,5=err : {}".format(rq.registers[2]))
print("1003 | cable limit detected [A] : {}".format(rq.registers[3]))
print("1004 | commands : {}".format(rq.registers[4]))
print(" b0 | turn off charging now : {}".format(rq.registers[4]&1>0))
print(" b1 | run RCD test procedure : {}".format(rq.registers[4]&2>0))
print(" b2 | clear RCD error : {}".format(rq.registers[4]&4>0))
print(" .. | reserved")
print("1005 | firmware revision : {}".format(rq.registers[5]))
print("1006 | EVSE state 1=12V,2=pwm,3=off : {}".format(rq.registers[6]))
print("1007 | status and fails : {}".format(rq.registers[7]))
print(" b0 | relay on/off : {}".format(rq.registers[7]&1>0))
print(" b1 | diode check fail : {}".format(rq.registers[7]&2>0))
print(" b2 | vent required fail : {}".format(rq.registers[7]&4>0))
print(" b3 | waiting for pilot release (err recovery delay) : {}".format(rq.registers[7]&8>0))
print(" b4 | RCD test in progress : {}".format(rq.registers[7]&16>0))
print(" b5 | RCD check error : {}".format(rq.registers[7]&32>0))
print(" .. | reserved")
print("1008 | error timeout countdown : {}".format(rq.registers[8]))
else:
print("Could not read runtime values ({} registers)".format(TOTAL_RUNTIME_REGISTERS))
else:
print("...RECONNECTING...")
serialClient.connect()
except Exception as e:
print("error when sending or receiving bytes: {}\n{}".format(rq,str(e)))
failCount += 1
serialClient.close()
time.sleep(1)
continue
time.sleep(1)
except KeyboardInterrupt:
print('interrupted!')
if serialClient.is_socket_open():
serialClient.close()
print("\nSCRIPT FINISHED: CYCLES: {} FAIL: {}".format(cycle, failCount))