From 0353751d15a90664698ab6e01265bf2dc07f6b21 Mon Sep 17 00:00:00 2001 From: Petr <5851137+pvyleta@users.noreply.github.com> Date: Sat, 28 Dec 2024 22:44:50 +0100 Subject: [PATCH] Added explanation commentary --- .../de/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/de/3c.Sky300.csv | 4 ++-- .../de/7c.Excellent400.csv | 4 ++-- .../en/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/en/3c.Sky300.csv | 4 ++-- .../en/7c.Excellent400.csv | 4 ++-- .../es/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/es/3c.Sky300.csv | 4 ++-- .../es/7c.Excellent400.csv | 4 ++-- .../fr/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/fr/3c.Sky300.csv | 4 ++-- .../fr/7c.Excellent400.csv | 4 ++-- .../it/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/it/3c.Sky300.csv | 4 ++-- .../it/7c.Excellent400.csv | 4 ++-- .../nl/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/nl/3c.Sky300.csv | 4 ++-- .../nl/7c.Excellent400.csv | 4 ++-- .../pl/3c.Excellent300.csv | 4 ++-- ebusd-configuration-known-slave-address/pl/3c.Sky300.csv | 4 ++-- .../pl/7c.Excellent400.csv | 4 ++-- .../de/CWLF250.10806.10808.csv | 4 ++-- .../de/CWLF250.10806.10808.plus.csv | 4 ++-- .../de/CWLF250.10809.99999.csv | 4 ++-- .../de/CWLF250.10809.99999.plus.csv | 4 ++-- .../de/CWLF350.10806.10808.csv | 4 ++-- .../de/CWLF350.10806.10808.plus.csv | 4 ++-- .../de/CWLF350.10809.99999.csv | 4 ++-- .../de/CWLF350.10809.99999.plus.csv | 4 ++-- .../de/CWLTower300.10603.10603.csv | 4 ++-- .../de/CWLTower300.10603.10603.plus.csv | 4 ++-- .../de/CWLTower300.10604.10605.csv | 4 ++-- .../de/CWLTower300.10604.10605.plus.csv | 4 ++-- .../de/CWLTower300.10606.10607.csv | 4 ++-- .../de/CWLTower300.10606.10607.plus.csv | 4 ++-- .../de/CWLTower300.10608.10706.csv | 4 ++-- .../de/CWLTower300.10608.10706.plus.csv | 4 ++-- .../de/CWLTower300.10801.10805.csv | 4 ++-- .../de/CWLTower300.10801.10805.plus.csv | 4 ++-- .../de/CWLTower300.10806.99999.csv | 4 ++-- .../de/CWLTower300.10806.99999.plus.csv | 4 ++-- .../de/ConstantRPM400.10505.99999.csv | 4 ++-- .../de/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../de/DecentralAir70.10101.10700.csv | 4 ++-- .../de/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../de/DecentralAir70.10701.99999.csv | 4 ++-- .../de/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../de/Elan10.10103.99999.csv | 4 ++-- .../de/Elan10.10103.99999.plus.csv | 4 ++-- .../de/Elan4.10104.99999.csv | 4 ++-- .../de/Elan4.10104.99999.plus.csv | 4 ++-- .../de/Excellent180.10503.10603.csv | 4 ++-- .../de/Excellent180.10503.10603.plus.csv | 4 ++-- .../de/Excellent180.10604.10605.csv | 4 ++-- .../de/Excellent180.10604.10605.plus.csv | 4 ++-- .../de/Excellent180.10606.10607.csv | 4 ++-- .../de/Excellent180.10606.10607.plus.csv | 4 ++-- .../de/Excellent180.10608.10706.csv | 4 ++-- .../de/Excellent180.10608.10706.plus.csv | 4 ++-- .../de/Excellent180.10801.10805.csv | 4 ++-- .../de/Excellent180.10801.10805.plus.csv | 4 ++-- .../de/Excellent180.10806.99999.csv | 4 ++-- .../de/Excellent180.10806.99999.plus.csv | 4 ++-- .../de/Excellent300.10502.10603.csv | 4 ++-- .../de/Excellent300.10502.10603.plus.csv | 4 ++-- .../de/Excellent300.10604.10605.csv | 4 ++-- .../de/Excellent300.10604.10605.plus.csv | 4 ++-- .../de/Excellent300.10606.10607.csv | 4 ++-- .../de/Excellent300.10606.10607.plus.csv | 4 ++-- .../de/Excellent300.10608.10706.csv | 4 ++-- .../de/Excellent300.10608.10706.plus.csv | 4 ++-- .../de/Excellent300.10801.10805.csv | 4 ++-- .../de/Excellent300.10801.10805.plus.csv | 4 ++-- .../de/Excellent300.10806.99999.csv | 4 ++-- .../de/Excellent300.10806.99999.plus.csv | 4 ++-- .../de/Excellent400.10401.10403.csv | 4 ++-- .../de/Excellent400.10401.10403.plus.csv | 4 ++-- .../de/Excellent400.10502.10603.csv | 4 ++-- .../de/Excellent400.10502.10603.plus.csv | 4 ++-- .../de/Excellent400.10604.10605.csv | 4 ++-- .../de/Excellent400.10604.10605.plus.csv | 4 ++-- .../de/Excellent400.10606.10607.csv | 4 ++-- .../de/Excellent400.10606.10607.plus.csv | 4 ++-- .../de/Excellent400.10608.10706.csv | 4 ++-- .../de/Excellent400.10608.10706.plus.csv | 4 ++-- .../de/Excellent400.10801.10805.csv | 4 ++-- .../de/Excellent400.10801.10805.plus.csv | 4 ++-- .../de/Excellent400.10806.99999.csv | 4 ++-- .../de/Excellent400.10806.99999.plus.csv | 4 ++-- .../de/Excellent450.10604.10605.csv | 4 ++-- .../de/Excellent450.10604.10605.plus.csv | 4 ++-- .../de/Excellent450.10606.10607.csv | 4 ++-- .../de/Excellent450.10606.10607.plus.csv | 4 ++-- .../de/Excellent450.10608.10706.csv | 4 ++-- .../de/Excellent450.10608.10706.plus.csv | 4 ++-- .../de/Excellent450.10801.10805.csv | 4 ++-- .../de/Excellent450.10801.10805.plus.csv | 4 ++-- .../de/Excellent450.10806.99999.csv | 4 ++-- .../de/Excellent450.10806.99999.plus.csv | 4 ++-- .../de/Flair200.10101.99999.csv | 4 ++-- .../de/Flair225.10101.99999.csv | 4 ++-- .../de/Flair300.10101.20105.csv | 4 ++-- .../de/Flair300.20106.99999.csv | 4 ++-- .../de/Flair325.10101.20105.csv | 4 ++-- .../de/Flair325.20106.99999.csv | 4 ++-- .../de/Flair400.10101.20105.csv | 4 ++-- .../de/Flair400.20106.99999.csv | 4 ++-- .../de/Flair450.10101.99999.csv | 4 ++-- .../de/Flair600.10101.99999.csv | 4 ++-- .../de/Nather300.10703.10706.csv | 4 ++-- .../de/Nather300.10703.10706.plus.csv | 4 ++-- .../de/Nather300.10801.10805.csv | 4 ++-- .../de/Nather300.10801.10805.plus.csv | 4 ++-- .../de/Nather300.10806.99999.csv | 4 ++-- .../de/Nather300.10806.99999.plus.csv | 4 ++-- .../de/RenoventElan300.10604.10605.csv | 4 ++-- .../de/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../de/RenoventElan300.10606.10607.csv | 4 ++-- .../de/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../de/RenoventElan300.10608.10706.csv | 4 ++-- .../de/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../de/RenoventElan300.10801.10805.csv | 4 ++-- .../de/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../de/RenoventElan300.10806.99999.csv | 4 ++-- .../de/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../de/Sky150.10504.10603.csv | 4 ++-- .../de/Sky150.10504.10603.plus.csv | 4 ++-- .../de/Sky150.10604.10605.csv | 4 ++-- .../de/Sky150.10604.10605.plus.csv | 4 ++-- .../de/Sky150.10606.10607.csv | 4 ++-- .../de/Sky150.10606.10607.plus.csv | 4 ++-- .../de/Sky150.10608.10706.csv | 4 ++-- .../de/Sky150.10608.10706.plus.csv | 4 ++-- .../de/Sky150.10801.10805.csv | 4 ++-- .../de/Sky150.10801.10805.plus.csv | 4 ++-- .../de/Sky150.10806.99999.csv | 4 ++-- .../de/Sky150.10806.99999.plus.csv | 4 ++-- .../de/Sky200.10702.10706.csv | 4 ++-- .../de/Sky200.10702.10706.plus.csv | 4 ++-- .../de/Sky200.10801.10805.csv | 4 ++-- .../de/Sky200.10801.10805.plus.csv | 4 ++-- .../de/Sky200.10806.99999.csv | 4 ++-- .../de/Sky200.10806.99999.plus.csv | 4 ++-- .../de/Sky300.10401.10403.csv | 4 ++-- .../de/Sky300.10401.10403.plus.csv | 4 ++-- .../de/Sky300.10502.10603.csv | 4 ++-- .../de/Sky300.10502.10603.plus.csv | 4 ++-- .../de/Sky300.10604.10605.csv | 4 ++-- .../de/Sky300.10604.10605.plus.csv | 4 ++-- .../de/Sky300.10606.10607.csv | 4 ++-- .../de/Sky300.10606.10607.plus.csv | 4 ++-- .../de/Sky300.10608.10706.csv | 4 ++-- .../de/Sky300.10608.10706.plus.csv | 4 ++-- .../de/Sky300.10801.10805.csv | 4 ++-- .../de/Sky300.10801.10805.plus.csv | 4 ++-- .../de/Sky300.10806.99999.csv | 4 ++-- .../de/Sky300.10806.99999.plus.csv | 4 ++-- .../de/Vitovent200W.10104.10104.csv | 4 ++-- .../de/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../de/Vitovent200W.10105.10105.csv | 4 ++-- .../de/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../de/Vitovent200W.10106.99999.csv | 4 ++-- .../de/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../de/Vitovent300C.10101.10105.csv | 4 ++-- .../de/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../de/Vitovent300C.10106.99999.csv | 4 ++-- .../de/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../de/Vitovent300W300.10101.10105.csv | 4 ++-- .../de/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../de/Vitovent300W300.10106.99999.csv | 4 ++-- .../de/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../de/Vitovent300W400.10101.10105.csv | 4 ++-- .../de/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../de/Vitovent300W400.10106.99999.csv | 4 ++-- .../de/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../de/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../de/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../de/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../de/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../de/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../de/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../de/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../de/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../en/CWLF250.10806.10808.csv | 4 ++-- .../en/CWLF250.10806.10808.plus.csv | 4 ++-- .../en/CWLF250.10809.99999.csv | 4 ++-- .../en/CWLF250.10809.99999.plus.csv | 4 ++-- .../en/CWLF350.10806.10808.csv | 4 ++-- .../en/CWLF350.10806.10808.plus.csv | 4 ++-- .../en/CWLF350.10809.99999.csv | 4 ++-- .../en/CWLF350.10809.99999.plus.csv | 4 ++-- .../en/CWLTower300.10603.10603.csv | 4 ++-- .../en/CWLTower300.10603.10603.plus.csv | 4 ++-- .../en/CWLTower300.10604.10605.csv | 4 ++-- .../en/CWLTower300.10604.10605.plus.csv | 4 ++-- .../en/CWLTower300.10606.10607.csv | 4 ++-- .../en/CWLTower300.10606.10607.plus.csv | 4 ++-- .../en/CWLTower300.10608.10706.csv | 4 ++-- .../en/CWLTower300.10608.10706.plus.csv | 4 ++-- .../en/CWLTower300.10801.10805.csv | 4 ++-- .../en/CWLTower300.10801.10805.plus.csv | 4 ++-- .../en/CWLTower300.10806.99999.csv | 4 ++-- .../en/CWLTower300.10806.99999.plus.csv | 4 ++-- .../en/ConstantRPM400.10505.99999.csv | 4 ++-- .../en/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../en/DecentralAir70.10101.10700.csv | 4 ++-- .../en/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../en/DecentralAir70.10701.99999.csv | 4 ++-- .../en/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../en/Elan10.10103.99999.csv | 4 ++-- .../en/Elan10.10103.99999.plus.csv | 4 ++-- .../en/Elan4.10104.99999.csv | 4 ++-- .../en/Elan4.10104.99999.plus.csv | 4 ++-- .../en/Excellent180.10503.10603.csv | 4 ++-- .../en/Excellent180.10503.10603.plus.csv | 4 ++-- .../en/Excellent180.10604.10605.csv | 4 ++-- .../en/Excellent180.10604.10605.plus.csv | 4 ++-- .../en/Excellent180.10606.10607.csv | 4 ++-- .../en/Excellent180.10606.10607.plus.csv | 4 ++-- .../en/Excellent180.10608.10706.csv | 4 ++-- .../en/Excellent180.10608.10706.plus.csv | 4 ++-- .../en/Excellent180.10801.10805.csv | 4 ++-- .../en/Excellent180.10801.10805.plus.csv | 4 ++-- .../en/Excellent180.10806.99999.csv | 4 ++-- .../en/Excellent180.10806.99999.plus.csv | 4 ++-- .../en/Excellent300.10502.10603.csv | 4 ++-- .../en/Excellent300.10502.10603.plus.csv | 4 ++-- .../en/Excellent300.10604.10605.csv | 4 ++-- .../en/Excellent300.10604.10605.plus.csv | 4 ++-- .../en/Excellent300.10606.10607.csv | 4 ++-- .../en/Excellent300.10606.10607.plus.csv | 4 ++-- .../en/Excellent300.10608.10706.csv | 4 ++-- .../en/Excellent300.10608.10706.plus.csv | 4 ++-- .../en/Excellent300.10801.10805.csv | 4 ++-- .../en/Excellent300.10801.10805.plus.csv | 4 ++-- .../en/Excellent300.10806.99999.csv | 4 ++-- .../en/Excellent300.10806.99999.plus.csv | 4 ++-- .../en/Excellent400.10401.10403.csv | 4 ++-- .../en/Excellent400.10401.10403.plus.csv | 4 ++-- .../en/Excellent400.10502.10603.csv | 4 ++-- .../en/Excellent400.10502.10603.plus.csv | 4 ++-- .../en/Excellent400.10604.10605.csv | 4 ++-- .../en/Excellent400.10604.10605.plus.csv | 4 ++-- .../en/Excellent400.10606.10607.csv | 4 ++-- .../en/Excellent400.10606.10607.plus.csv | 4 ++-- .../en/Excellent400.10608.10706.csv | 4 ++-- .../en/Excellent400.10608.10706.plus.csv | 4 ++-- .../en/Excellent400.10801.10805.csv | 4 ++-- .../en/Excellent400.10801.10805.plus.csv | 4 ++-- .../en/Excellent400.10806.99999.csv | 4 ++-- .../en/Excellent400.10806.99999.plus.csv | 4 ++-- .../en/Excellent450.10604.10605.csv | 4 ++-- .../en/Excellent450.10604.10605.plus.csv | 4 ++-- .../en/Excellent450.10606.10607.csv | 4 ++-- .../en/Excellent450.10606.10607.plus.csv | 4 ++-- .../en/Excellent450.10608.10706.csv | 4 ++-- .../en/Excellent450.10608.10706.plus.csv | 4 ++-- .../en/Excellent450.10801.10805.csv | 4 ++-- .../en/Excellent450.10801.10805.plus.csv | 4 ++-- .../en/Excellent450.10806.99999.csv | 4 ++-- .../en/Excellent450.10806.99999.plus.csv | 4 ++-- .../en/Flair200.10101.99999.csv | 4 ++-- .../en/Flair225.10101.99999.csv | 4 ++-- .../en/Flair300.10101.20105.csv | 4 ++-- .../en/Flair300.20106.99999.csv | 4 ++-- .../en/Flair325.10101.20105.csv | 4 ++-- .../en/Flair325.20106.99999.csv | 4 ++-- .../en/Flair400.10101.20105.csv | 4 ++-- .../en/Flair400.20106.99999.csv | 4 ++-- .../en/Flair450.10101.99999.csv | 4 ++-- .../en/Flair600.10101.99999.csv | 4 ++-- .../en/Nather300.10703.10706.csv | 4 ++-- .../en/Nather300.10703.10706.plus.csv | 4 ++-- .../en/Nather300.10801.10805.csv | 4 ++-- .../en/Nather300.10801.10805.plus.csv | 4 ++-- .../en/Nather300.10806.99999.csv | 4 ++-- .../en/Nather300.10806.99999.plus.csv | 4 ++-- .../en/RenoventElan300.10604.10605.csv | 4 ++-- .../en/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../en/RenoventElan300.10606.10607.csv | 4 ++-- .../en/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../en/RenoventElan300.10608.10706.csv | 4 ++-- .../en/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../en/RenoventElan300.10801.10805.csv | 4 ++-- .../en/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../en/RenoventElan300.10806.99999.csv | 4 ++-- .../en/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../en/Sky150.10504.10603.csv | 4 ++-- .../en/Sky150.10504.10603.plus.csv | 4 ++-- .../en/Sky150.10604.10605.csv | 4 ++-- .../en/Sky150.10604.10605.plus.csv | 4 ++-- .../en/Sky150.10606.10607.csv | 4 ++-- .../en/Sky150.10606.10607.plus.csv | 4 ++-- .../en/Sky150.10608.10706.csv | 4 ++-- .../en/Sky150.10608.10706.plus.csv | 4 ++-- .../en/Sky150.10801.10805.csv | 4 ++-- .../en/Sky150.10801.10805.plus.csv | 4 ++-- .../en/Sky150.10806.99999.csv | 4 ++-- .../en/Sky150.10806.99999.plus.csv | 4 ++-- .../en/Sky200.10702.10706.csv | 4 ++-- .../en/Sky200.10702.10706.plus.csv | 4 ++-- .../en/Sky200.10801.10805.csv | 4 ++-- .../en/Sky200.10801.10805.plus.csv | 4 ++-- .../en/Sky200.10806.99999.csv | 4 ++-- .../en/Sky200.10806.99999.plus.csv | 4 ++-- .../en/Sky300.10401.10403.csv | 4 ++-- .../en/Sky300.10401.10403.plus.csv | 4 ++-- .../en/Sky300.10502.10603.csv | 4 ++-- .../en/Sky300.10502.10603.plus.csv | 4 ++-- .../en/Sky300.10604.10605.csv | 4 ++-- .../en/Sky300.10604.10605.plus.csv | 4 ++-- .../en/Sky300.10606.10607.csv | 4 ++-- .../en/Sky300.10606.10607.plus.csv | 4 ++-- .../en/Sky300.10608.10706.csv | 4 ++-- .../en/Sky300.10608.10706.plus.csv | 4 ++-- .../en/Sky300.10801.10805.csv | 4 ++-- .../en/Sky300.10801.10805.plus.csv | 4 ++-- .../en/Sky300.10806.99999.csv | 4 ++-- .../en/Sky300.10806.99999.plus.csv | 4 ++-- .../en/Vitovent200W.10104.10104.csv | 4 ++-- .../en/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../en/Vitovent200W.10105.10105.csv | 4 ++-- .../en/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../en/Vitovent200W.10106.99999.csv | 4 ++-- .../en/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../en/Vitovent300C.10101.10105.csv | 4 ++-- .../en/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../en/Vitovent300C.10106.99999.csv | 4 ++-- .../en/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../en/Vitovent300W300.10101.10105.csv | 4 ++-- .../en/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../en/Vitovent300W300.10106.99999.csv | 4 ++-- .../en/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../en/Vitovent300W400.10101.10105.csv | 4 ++-- .../en/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../en/Vitovent300W400.10106.99999.csv | 4 ++-- .../en/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../en/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../en/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../en/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../en/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../en/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../en/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../en/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../en/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../es/CWLF250.10806.10808.csv | 4 ++-- .../es/CWLF250.10806.10808.plus.csv | 4 ++-- .../es/CWLF250.10809.99999.csv | 4 ++-- .../es/CWLF250.10809.99999.plus.csv | 4 ++-- .../es/CWLF350.10806.10808.csv | 4 ++-- .../es/CWLF350.10806.10808.plus.csv | 4 ++-- .../es/CWLF350.10809.99999.csv | 4 ++-- .../es/CWLF350.10809.99999.plus.csv | 4 ++-- .../es/CWLTower300.10603.10603.csv | 4 ++-- .../es/CWLTower300.10603.10603.plus.csv | 4 ++-- .../es/CWLTower300.10604.10605.csv | 4 ++-- .../es/CWLTower300.10604.10605.plus.csv | 4 ++-- .../es/CWLTower300.10606.10607.csv | 4 ++-- .../es/CWLTower300.10606.10607.plus.csv | 4 ++-- .../es/CWLTower300.10608.10706.csv | 4 ++-- .../es/CWLTower300.10608.10706.plus.csv | 4 ++-- .../es/CWLTower300.10801.10805.csv | 4 ++-- .../es/CWLTower300.10801.10805.plus.csv | 4 ++-- .../es/CWLTower300.10806.99999.csv | 4 ++-- .../es/CWLTower300.10806.99999.plus.csv | 4 ++-- .../es/ConstantRPM400.10505.99999.csv | 4 ++-- .../es/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../es/DecentralAir70.10101.10700.csv | 4 ++-- .../es/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../es/DecentralAir70.10701.99999.csv | 4 ++-- .../es/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../es/Elan10.10103.99999.csv | 4 ++-- .../es/Elan10.10103.99999.plus.csv | 4 ++-- .../es/Elan4.10104.99999.csv | 4 ++-- .../es/Elan4.10104.99999.plus.csv | 4 ++-- .../es/Excellent180.10503.10603.csv | 4 ++-- .../es/Excellent180.10503.10603.plus.csv | 4 ++-- .../es/Excellent180.10604.10605.csv | 4 ++-- .../es/Excellent180.10604.10605.plus.csv | 4 ++-- .../es/Excellent180.10606.10607.csv | 4 ++-- .../es/Excellent180.10606.10607.plus.csv | 4 ++-- .../es/Excellent180.10608.10706.csv | 4 ++-- .../es/Excellent180.10608.10706.plus.csv | 4 ++-- .../es/Excellent180.10801.10805.csv | 4 ++-- .../es/Excellent180.10801.10805.plus.csv | 4 ++-- .../es/Excellent180.10806.99999.csv | 4 ++-- .../es/Excellent180.10806.99999.plus.csv | 4 ++-- .../es/Excellent300.10502.10603.csv | 4 ++-- .../es/Excellent300.10502.10603.plus.csv | 4 ++-- .../es/Excellent300.10604.10605.csv | 4 ++-- .../es/Excellent300.10604.10605.plus.csv | 4 ++-- .../es/Excellent300.10606.10607.csv | 4 ++-- .../es/Excellent300.10606.10607.plus.csv | 4 ++-- .../es/Excellent300.10608.10706.csv | 4 ++-- .../es/Excellent300.10608.10706.plus.csv | 4 ++-- .../es/Excellent300.10801.10805.csv | 4 ++-- .../es/Excellent300.10801.10805.plus.csv | 4 ++-- .../es/Excellent300.10806.99999.csv | 4 ++-- .../es/Excellent300.10806.99999.plus.csv | 4 ++-- .../es/Excellent400.10401.10403.csv | 4 ++-- .../es/Excellent400.10401.10403.plus.csv | 4 ++-- .../es/Excellent400.10502.10603.csv | 4 ++-- .../es/Excellent400.10502.10603.plus.csv | 4 ++-- .../es/Excellent400.10604.10605.csv | 4 ++-- .../es/Excellent400.10604.10605.plus.csv | 4 ++-- .../es/Excellent400.10606.10607.csv | 4 ++-- .../es/Excellent400.10606.10607.plus.csv | 4 ++-- .../es/Excellent400.10608.10706.csv | 4 ++-- .../es/Excellent400.10608.10706.plus.csv | 4 ++-- .../es/Excellent400.10801.10805.csv | 4 ++-- .../es/Excellent400.10801.10805.plus.csv | 4 ++-- .../es/Excellent400.10806.99999.csv | 4 ++-- .../es/Excellent400.10806.99999.plus.csv | 4 ++-- .../es/Excellent450.10604.10605.csv | 4 ++-- .../es/Excellent450.10604.10605.plus.csv | 4 ++-- .../es/Excellent450.10606.10607.csv | 4 ++-- .../es/Excellent450.10606.10607.plus.csv | 4 ++-- .../es/Excellent450.10608.10706.csv | 4 ++-- .../es/Excellent450.10608.10706.plus.csv | 4 ++-- .../es/Excellent450.10801.10805.csv | 4 ++-- .../es/Excellent450.10801.10805.plus.csv | 4 ++-- .../es/Excellent450.10806.99999.csv | 4 ++-- .../es/Excellent450.10806.99999.plus.csv | 4 ++-- .../es/Flair200.10101.99999.csv | 4 ++-- .../es/Flair225.10101.99999.csv | 4 ++-- .../es/Flair300.10101.20105.csv | 4 ++-- .../es/Flair300.20106.99999.csv | 4 ++-- .../es/Flair325.10101.20105.csv | 4 ++-- .../es/Flair325.20106.99999.csv | 4 ++-- .../es/Flair400.10101.20105.csv | 4 ++-- .../es/Flair400.20106.99999.csv | 4 ++-- .../es/Flair450.10101.99999.csv | 4 ++-- .../es/Flair600.10101.99999.csv | 4 ++-- .../es/Nather300.10703.10706.csv | 4 ++-- .../es/Nather300.10703.10706.plus.csv | 4 ++-- .../es/Nather300.10801.10805.csv | 4 ++-- .../es/Nather300.10801.10805.plus.csv | 4 ++-- .../es/Nather300.10806.99999.csv | 4 ++-- .../es/Nather300.10806.99999.plus.csv | 4 ++-- .../es/RenoventElan300.10604.10605.csv | 4 ++-- .../es/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../es/RenoventElan300.10606.10607.csv | 4 ++-- .../es/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../es/RenoventElan300.10608.10706.csv | 4 ++-- .../es/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../es/RenoventElan300.10801.10805.csv | 4 ++-- .../es/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../es/RenoventElan300.10806.99999.csv | 4 ++-- .../es/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../es/Sky150.10504.10603.csv | 4 ++-- .../es/Sky150.10504.10603.plus.csv | 4 ++-- .../es/Sky150.10604.10605.csv | 4 ++-- .../es/Sky150.10604.10605.plus.csv | 4 ++-- .../es/Sky150.10606.10607.csv | 4 ++-- .../es/Sky150.10606.10607.plus.csv | 4 ++-- .../es/Sky150.10608.10706.csv | 4 ++-- .../es/Sky150.10608.10706.plus.csv | 4 ++-- .../es/Sky150.10801.10805.csv | 4 ++-- .../es/Sky150.10801.10805.plus.csv | 4 ++-- .../es/Sky150.10806.99999.csv | 4 ++-- .../es/Sky150.10806.99999.plus.csv | 4 ++-- .../es/Sky200.10702.10706.csv | 4 ++-- .../es/Sky200.10702.10706.plus.csv | 4 ++-- .../es/Sky200.10801.10805.csv | 4 ++-- .../es/Sky200.10801.10805.plus.csv | 4 ++-- .../es/Sky200.10806.99999.csv | 4 ++-- .../es/Sky200.10806.99999.plus.csv | 4 ++-- .../es/Sky300.10401.10403.csv | 4 ++-- .../es/Sky300.10401.10403.plus.csv | 4 ++-- .../es/Sky300.10502.10603.csv | 4 ++-- .../es/Sky300.10502.10603.plus.csv | 4 ++-- .../es/Sky300.10604.10605.csv | 4 ++-- .../es/Sky300.10604.10605.plus.csv | 4 ++-- .../es/Sky300.10606.10607.csv | 4 ++-- .../es/Sky300.10606.10607.plus.csv | 4 ++-- .../es/Sky300.10608.10706.csv | 4 ++-- .../es/Sky300.10608.10706.plus.csv | 4 ++-- .../es/Sky300.10801.10805.csv | 4 ++-- .../es/Sky300.10801.10805.plus.csv | 4 ++-- .../es/Sky300.10806.99999.csv | 4 ++-- .../es/Sky300.10806.99999.plus.csv | 4 ++-- .../es/Vitovent200W.10104.10104.csv | 4 ++-- .../es/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../es/Vitovent200W.10105.10105.csv | 4 ++-- .../es/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../es/Vitovent200W.10106.99999.csv | 4 ++-- .../es/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../es/Vitovent300C.10101.10105.csv | 4 ++-- .../es/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../es/Vitovent300C.10106.99999.csv | 4 ++-- .../es/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../es/Vitovent300W300.10101.10105.csv | 4 ++-- .../es/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../es/Vitovent300W300.10106.99999.csv | 4 ++-- .../es/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../es/Vitovent300W400.10101.10105.csv | 4 ++-- .../es/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../es/Vitovent300W400.10106.99999.csv | 4 ++-- .../es/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../es/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../es/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../es/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../es/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../es/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../es/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../es/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../es/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../fr/CWLF250.10806.10808.csv | 4 ++-- .../fr/CWLF250.10806.10808.plus.csv | 4 ++-- .../fr/CWLF250.10809.99999.csv | 4 ++-- .../fr/CWLF250.10809.99999.plus.csv | 4 ++-- .../fr/CWLF350.10806.10808.csv | 4 ++-- .../fr/CWLF350.10806.10808.plus.csv | 4 ++-- .../fr/CWLF350.10809.99999.csv | 4 ++-- .../fr/CWLF350.10809.99999.plus.csv | 4 ++-- .../fr/CWLTower300.10603.10603.csv | 4 ++-- .../fr/CWLTower300.10603.10603.plus.csv | 4 ++-- .../fr/CWLTower300.10604.10605.csv | 4 ++-- .../fr/CWLTower300.10604.10605.plus.csv | 4 ++-- .../fr/CWLTower300.10606.10607.csv | 4 ++-- .../fr/CWLTower300.10606.10607.plus.csv | 4 ++-- .../fr/CWLTower300.10608.10706.csv | 4 ++-- .../fr/CWLTower300.10608.10706.plus.csv | 4 ++-- .../fr/CWLTower300.10801.10805.csv | 4 ++-- .../fr/CWLTower300.10801.10805.plus.csv | 4 ++-- .../fr/CWLTower300.10806.99999.csv | 4 ++-- .../fr/CWLTower300.10806.99999.plus.csv | 4 ++-- .../fr/ConstantRPM400.10505.99999.csv | 4 ++-- .../fr/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../fr/DecentralAir70.10101.10700.csv | 4 ++-- .../fr/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../fr/DecentralAir70.10701.99999.csv | 4 ++-- .../fr/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../fr/Elan10.10103.99999.csv | 4 ++-- .../fr/Elan10.10103.99999.plus.csv | 4 ++-- .../fr/Elan4.10104.99999.csv | 4 ++-- .../fr/Elan4.10104.99999.plus.csv | 4 ++-- .../fr/Excellent180.10503.10603.csv | 4 ++-- .../fr/Excellent180.10503.10603.plus.csv | 4 ++-- .../fr/Excellent180.10604.10605.csv | 4 ++-- .../fr/Excellent180.10604.10605.plus.csv | 4 ++-- .../fr/Excellent180.10606.10607.csv | 4 ++-- .../fr/Excellent180.10606.10607.plus.csv | 4 ++-- .../fr/Excellent180.10608.10706.csv | 4 ++-- .../fr/Excellent180.10608.10706.plus.csv | 4 ++-- .../fr/Excellent180.10801.10805.csv | 4 ++-- .../fr/Excellent180.10801.10805.plus.csv | 4 ++-- .../fr/Excellent180.10806.99999.csv | 4 ++-- .../fr/Excellent180.10806.99999.plus.csv | 4 ++-- .../fr/Excellent300.10502.10603.csv | 4 ++-- .../fr/Excellent300.10502.10603.plus.csv | 4 ++-- .../fr/Excellent300.10604.10605.csv | 4 ++-- .../fr/Excellent300.10604.10605.plus.csv | 4 ++-- .../fr/Excellent300.10606.10607.csv | 4 ++-- .../fr/Excellent300.10606.10607.plus.csv | 4 ++-- .../fr/Excellent300.10608.10706.csv | 4 ++-- .../fr/Excellent300.10608.10706.plus.csv | 4 ++-- .../fr/Excellent300.10801.10805.csv | 4 ++-- .../fr/Excellent300.10801.10805.plus.csv | 4 ++-- .../fr/Excellent300.10806.99999.csv | 4 ++-- .../fr/Excellent300.10806.99999.plus.csv | 4 ++-- .../fr/Excellent400.10401.10403.csv | 4 ++-- .../fr/Excellent400.10401.10403.plus.csv | 4 ++-- .../fr/Excellent400.10502.10603.csv | 4 ++-- .../fr/Excellent400.10502.10603.plus.csv | 4 ++-- .../fr/Excellent400.10604.10605.csv | 4 ++-- .../fr/Excellent400.10604.10605.plus.csv | 4 ++-- .../fr/Excellent400.10606.10607.csv | 4 ++-- .../fr/Excellent400.10606.10607.plus.csv | 4 ++-- .../fr/Excellent400.10608.10706.csv | 4 ++-- .../fr/Excellent400.10608.10706.plus.csv | 4 ++-- .../fr/Excellent400.10801.10805.csv | 4 ++-- .../fr/Excellent400.10801.10805.plus.csv | 4 ++-- .../fr/Excellent400.10806.99999.csv | 4 ++-- .../fr/Excellent400.10806.99999.plus.csv | 4 ++-- .../fr/Excellent450.10604.10605.csv | 4 ++-- .../fr/Excellent450.10604.10605.plus.csv | 4 ++-- .../fr/Excellent450.10606.10607.csv | 4 ++-- .../fr/Excellent450.10606.10607.plus.csv | 4 ++-- .../fr/Excellent450.10608.10706.csv | 4 ++-- .../fr/Excellent450.10608.10706.plus.csv | 4 ++-- .../fr/Excellent450.10801.10805.csv | 4 ++-- .../fr/Excellent450.10801.10805.plus.csv | 4 ++-- .../fr/Excellent450.10806.99999.csv | 4 ++-- .../fr/Excellent450.10806.99999.plus.csv | 4 ++-- .../fr/Flair200.10101.99999.csv | 4 ++-- .../fr/Flair225.10101.99999.csv | 4 ++-- .../fr/Flair300.10101.20105.csv | 4 ++-- .../fr/Flair300.20106.99999.csv | 4 ++-- .../fr/Flair325.10101.20105.csv | 4 ++-- .../fr/Flair325.20106.99999.csv | 4 ++-- .../fr/Flair400.10101.20105.csv | 4 ++-- .../fr/Flair400.20106.99999.csv | 4 ++-- .../fr/Flair450.10101.99999.csv | 4 ++-- .../fr/Flair600.10101.99999.csv | 4 ++-- .../fr/Nather300.10703.10706.csv | 4 ++-- .../fr/Nather300.10703.10706.plus.csv | 4 ++-- .../fr/Nather300.10801.10805.csv | 4 ++-- .../fr/Nather300.10801.10805.plus.csv | 4 ++-- .../fr/Nather300.10806.99999.csv | 4 ++-- .../fr/Nather300.10806.99999.plus.csv | 4 ++-- .../fr/RenoventElan300.10604.10605.csv | 4 ++-- .../fr/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../fr/RenoventElan300.10606.10607.csv | 4 ++-- .../fr/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../fr/RenoventElan300.10608.10706.csv | 4 ++-- .../fr/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../fr/RenoventElan300.10801.10805.csv | 4 ++-- .../fr/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../fr/RenoventElan300.10806.99999.csv | 4 ++-- .../fr/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../fr/Sky150.10504.10603.csv | 4 ++-- .../fr/Sky150.10504.10603.plus.csv | 4 ++-- .../fr/Sky150.10604.10605.csv | 4 ++-- .../fr/Sky150.10604.10605.plus.csv | 4 ++-- .../fr/Sky150.10606.10607.csv | 4 ++-- .../fr/Sky150.10606.10607.plus.csv | 4 ++-- .../fr/Sky150.10608.10706.csv | 4 ++-- .../fr/Sky150.10608.10706.plus.csv | 4 ++-- .../fr/Sky150.10801.10805.csv | 4 ++-- .../fr/Sky150.10801.10805.plus.csv | 4 ++-- .../fr/Sky150.10806.99999.csv | 4 ++-- .../fr/Sky150.10806.99999.plus.csv | 4 ++-- .../fr/Sky200.10702.10706.csv | 4 ++-- .../fr/Sky200.10702.10706.plus.csv | 4 ++-- .../fr/Sky200.10801.10805.csv | 4 ++-- .../fr/Sky200.10801.10805.plus.csv | 4 ++-- .../fr/Sky200.10806.99999.csv | 4 ++-- .../fr/Sky200.10806.99999.plus.csv | 4 ++-- .../fr/Sky300.10401.10403.csv | 4 ++-- .../fr/Sky300.10401.10403.plus.csv | 4 ++-- .../fr/Sky300.10502.10603.csv | 4 ++-- .../fr/Sky300.10502.10603.plus.csv | 4 ++-- .../fr/Sky300.10604.10605.csv | 4 ++-- .../fr/Sky300.10604.10605.plus.csv | 4 ++-- .../fr/Sky300.10606.10607.csv | 4 ++-- .../fr/Sky300.10606.10607.plus.csv | 4 ++-- .../fr/Sky300.10608.10706.csv | 4 ++-- .../fr/Sky300.10608.10706.plus.csv | 4 ++-- .../fr/Sky300.10801.10805.csv | 4 ++-- .../fr/Sky300.10801.10805.plus.csv | 4 ++-- .../fr/Sky300.10806.99999.csv | 4 ++-- .../fr/Sky300.10806.99999.plus.csv | 4 ++-- .../fr/Vitovent200W.10104.10104.csv | 4 ++-- .../fr/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../fr/Vitovent200W.10105.10105.csv | 4 ++-- .../fr/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../fr/Vitovent200W.10106.99999.csv | 4 ++-- .../fr/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../fr/Vitovent300C.10101.10105.csv | 4 ++-- .../fr/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../fr/Vitovent300C.10106.99999.csv | 4 ++-- .../fr/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../fr/Vitovent300W300.10101.10105.csv | 4 ++-- .../fr/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../fr/Vitovent300W300.10106.99999.csv | 4 ++-- .../fr/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../fr/Vitovent300W400.10101.10105.csv | 4 ++-- .../fr/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../fr/Vitovent300W400.10106.99999.csv | 4 ++-- .../fr/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../fr/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../fr/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../fr/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../fr/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../fr/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../fr/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../fr/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../fr/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../it/CWLF250.10806.10808.csv | 4 ++-- .../it/CWLF250.10806.10808.plus.csv | 4 ++-- .../it/CWLF250.10809.99999.csv | 4 ++-- .../it/CWLF250.10809.99999.plus.csv | 4 ++-- .../it/CWLF350.10806.10808.csv | 4 ++-- .../it/CWLF350.10806.10808.plus.csv | 4 ++-- .../it/CWLF350.10809.99999.csv | 4 ++-- .../it/CWLF350.10809.99999.plus.csv | 4 ++-- .../it/CWLTower300.10603.10603.csv | 4 ++-- .../it/CWLTower300.10603.10603.plus.csv | 4 ++-- .../it/CWLTower300.10604.10605.csv | 4 ++-- .../it/CWLTower300.10604.10605.plus.csv | 4 ++-- .../it/CWLTower300.10606.10607.csv | 4 ++-- .../it/CWLTower300.10606.10607.plus.csv | 4 ++-- .../it/CWLTower300.10608.10706.csv | 4 ++-- .../it/CWLTower300.10608.10706.plus.csv | 4 ++-- .../it/CWLTower300.10801.10805.csv | 4 ++-- .../it/CWLTower300.10801.10805.plus.csv | 4 ++-- .../it/CWLTower300.10806.99999.csv | 4 ++-- .../it/CWLTower300.10806.99999.plus.csv | 4 ++-- .../it/ConstantRPM400.10505.99999.csv | 4 ++-- .../it/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../it/DecentralAir70.10101.10700.csv | 4 ++-- .../it/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../it/DecentralAir70.10701.99999.csv | 4 ++-- .../it/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../it/Elan10.10103.99999.csv | 4 ++-- .../it/Elan10.10103.99999.plus.csv | 4 ++-- .../it/Elan4.10104.99999.csv | 4 ++-- .../it/Elan4.10104.99999.plus.csv | 4 ++-- .../it/Excellent180.10503.10603.csv | 4 ++-- .../it/Excellent180.10503.10603.plus.csv | 4 ++-- .../it/Excellent180.10604.10605.csv | 4 ++-- .../it/Excellent180.10604.10605.plus.csv | 4 ++-- .../it/Excellent180.10606.10607.csv | 4 ++-- .../it/Excellent180.10606.10607.plus.csv | 4 ++-- .../it/Excellent180.10608.10706.csv | 4 ++-- .../it/Excellent180.10608.10706.plus.csv | 4 ++-- .../it/Excellent180.10801.10805.csv | 4 ++-- .../it/Excellent180.10801.10805.plus.csv | 4 ++-- .../it/Excellent180.10806.99999.csv | 4 ++-- .../it/Excellent180.10806.99999.plus.csv | 4 ++-- .../it/Excellent300.10502.10603.csv | 4 ++-- .../it/Excellent300.10502.10603.plus.csv | 4 ++-- .../it/Excellent300.10604.10605.csv | 4 ++-- .../it/Excellent300.10604.10605.plus.csv | 4 ++-- .../it/Excellent300.10606.10607.csv | 4 ++-- .../it/Excellent300.10606.10607.plus.csv | 4 ++-- .../it/Excellent300.10608.10706.csv | 4 ++-- .../it/Excellent300.10608.10706.plus.csv | 4 ++-- .../it/Excellent300.10801.10805.csv | 4 ++-- .../it/Excellent300.10801.10805.plus.csv | 4 ++-- .../it/Excellent300.10806.99999.csv | 4 ++-- .../it/Excellent300.10806.99999.plus.csv | 4 ++-- .../it/Excellent400.10401.10403.csv | 4 ++-- .../it/Excellent400.10401.10403.plus.csv | 4 ++-- .../it/Excellent400.10502.10603.csv | 4 ++-- .../it/Excellent400.10502.10603.plus.csv | 4 ++-- .../it/Excellent400.10604.10605.csv | 4 ++-- .../it/Excellent400.10604.10605.plus.csv | 4 ++-- .../it/Excellent400.10606.10607.csv | 4 ++-- .../it/Excellent400.10606.10607.plus.csv | 4 ++-- .../it/Excellent400.10608.10706.csv | 4 ++-- .../it/Excellent400.10608.10706.plus.csv | 4 ++-- .../it/Excellent400.10801.10805.csv | 4 ++-- .../it/Excellent400.10801.10805.plus.csv | 4 ++-- .../it/Excellent400.10806.99999.csv | 4 ++-- .../it/Excellent400.10806.99999.plus.csv | 4 ++-- .../it/Excellent450.10604.10605.csv | 4 ++-- .../it/Excellent450.10604.10605.plus.csv | 4 ++-- .../it/Excellent450.10606.10607.csv | 4 ++-- .../it/Excellent450.10606.10607.plus.csv | 4 ++-- .../it/Excellent450.10608.10706.csv | 4 ++-- .../it/Excellent450.10608.10706.plus.csv | 4 ++-- .../it/Excellent450.10801.10805.csv | 4 ++-- .../it/Excellent450.10801.10805.plus.csv | 4 ++-- .../it/Excellent450.10806.99999.csv | 4 ++-- .../it/Excellent450.10806.99999.plus.csv | 4 ++-- .../it/Flair200.10101.99999.csv | 4 ++-- .../it/Flair225.10101.99999.csv | 4 ++-- .../it/Flair300.10101.20105.csv | 4 ++-- .../it/Flair300.20106.99999.csv | 4 ++-- .../it/Flair325.10101.20105.csv | 4 ++-- .../it/Flair325.20106.99999.csv | 4 ++-- .../it/Flair400.10101.20105.csv | 4 ++-- .../it/Flair400.20106.99999.csv | 4 ++-- .../it/Flair450.10101.99999.csv | 4 ++-- .../it/Flair600.10101.99999.csv | 4 ++-- .../it/Nather300.10703.10706.csv | 4 ++-- .../it/Nather300.10703.10706.plus.csv | 4 ++-- .../it/Nather300.10801.10805.csv | 4 ++-- .../it/Nather300.10801.10805.plus.csv | 4 ++-- .../it/Nather300.10806.99999.csv | 4 ++-- .../it/Nather300.10806.99999.plus.csv | 4 ++-- .../it/RenoventElan300.10604.10605.csv | 4 ++-- .../it/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../it/RenoventElan300.10606.10607.csv | 4 ++-- .../it/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../it/RenoventElan300.10608.10706.csv | 4 ++-- .../it/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../it/RenoventElan300.10801.10805.csv | 4 ++-- .../it/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../it/RenoventElan300.10806.99999.csv | 4 ++-- .../it/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../it/Sky150.10504.10603.csv | 4 ++-- .../it/Sky150.10504.10603.plus.csv | 4 ++-- .../it/Sky150.10604.10605.csv | 4 ++-- .../it/Sky150.10604.10605.plus.csv | 4 ++-- .../it/Sky150.10606.10607.csv | 4 ++-- .../it/Sky150.10606.10607.plus.csv | 4 ++-- .../it/Sky150.10608.10706.csv | 4 ++-- .../it/Sky150.10608.10706.plus.csv | 4 ++-- .../it/Sky150.10801.10805.csv | 4 ++-- .../it/Sky150.10801.10805.plus.csv | 4 ++-- .../it/Sky150.10806.99999.csv | 4 ++-- .../it/Sky150.10806.99999.plus.csv | 4 ++-- .../it/Sky200.10702.10706.csv | 4 ++-- .../it/Sky200.10702.10706.plus.csv | 4 ++-- .../it/Sky200.10801.10805.csv | 4 ++-- .../it/Sky200.10801.10805.plus.csv | 4 ++-- .../it/Sky200.10806.99999.csv | 4 ++-- .../it/Sky200.10806.99999.plus.csv | 4 ++-- .../it/Sky300.10401.10403.csv | 4 ++-- .../it/Sky300.10401.10403.plus.csv | 4 ++-- .../it/Sky300.10502.10603.csv | 4 ++-- .../it/Sky300.10502.10603.plus.csv | 4 ++-- .../it/Sky300.10604.10605.csv | 4 ++-- .../it/Sky300.10604.10605.plus.csv | 4 ++-- .../it/Sky300.10606.10607.csv | 4 ++-- .../it/Sky300.10606.10607.plus.csv | 4 ++-- .../it/Sky300.10608.10706.csv | 4 ++-- .../it/Sky300.10608.10706.plus.csv | 4 ++-- .../it/Sky300.10801.10805.csv | 4 ++-- .../it/Sky300.10801.10805.plus.csv | 4 ++-- .../it/Sky300.10806.99999.csv | 4 ++-- .../it/Sky300.10806.99999.plus.csv | 4 ++-- .../it/Vitovent200W.10104.10104.csv | 4 ++-- .../it/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../it/Vitovent200W.10105.10105.csv | 4 ++-- .../it/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../it/Vitovent200W.10106.99999.csv | 4 ++-- .../it/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../it/Vitovent300C.10101.10105.csv | 4 ++-- .../it/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../it/Vitovent300C.10106.99999.csv | 4 ++-- .../it/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../it/Vitovent300W300.10101.10105.csv | 4 ++-- .../it/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../it/Vitovent300W300.10106.99999.csv | 4 ++-- .../it/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../it/Vitovent300W400.10101.10105.csv | 4 ++-- .../it/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../it/Vitovent300W400.10106.99999.csv | 4 ++-- .../it/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../it/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../it/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../it/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../it/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../it/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../it/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../it/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../it/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../nl/CWLF250.10806.10808.csv | 4 ++-- .../nl/CWLF250.10806.10808.plus.csv | 4 ++-- .../nl/CWLF250.10809.99999.csv | 4 ++-- .../nl/CWLF250.10809.99999.plus.csv | 4 ++-- .../nl/CWLF350.10806.10808.csv | 4 ++-- .../nl/CWLF350.10806.10808.plus.csv | 4 ++-- .../nl/CWLF350.10809.99999.csv | 4 ++-- .../nl/CWLF350.10809.99999.plus.csv | 4 ++-- .../nl/CWLTower300.10603.10603.csv | 4 ++-- .../nl/CWLTower300.10603.10603.plus.csv | 4 ++-- .../nl/CWLTower300.10604.10605.csv | 4 ++-- .../nl/CWLTower300.10604.10605.plus.csv | 4 ++-- .../nl/CWLTower300.10606.10607.csv | 4 ++-- .../nl/CWLTower300.10606.10607.plus.csv | 4 ++-- .../nl/CWLTower300.10608.10706.csv | 4 ++-- .../nl/CWLTower300.10608.10706.plus.csv | 4 ++-- .../nl/CWLTower300.10801.10805.csv | 4 ++-- .../nl/CWLTower300.10801.10805.plus.csv | 4 ++-- .../nl/CWLTower300.10806.99999.csv | 4 ++-- .../nl/CWLTower300.10806.99999.plus.csv | 4 ++-- .../nl/ConstantRPM400.10505.99999.csv | 4 ++-- .../nl/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../nl/DecentralAir70.10101.10700.csv | 4 ++-- .../nl/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../nl/DecentralAir70.10701.99999.csv | 4 ++-- .../nl/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../nl/Elan10.10103.99999.csv | 4 ++-- .../nl/Elan10.10103.99999.plus.csv | 4 ++-- .../nl/Elan4.10104.99999.csv | 4 ++-- .../nl/Elan4.10104.99999.plus.csv | 4 ++-- .../nl/Excellent180.10503.10603.csv | 4 ++-- .../nl/Excellent180.10503.10603.plus.csv | 4 ++-- .../nl/Excellent180.10604.10605.csv | 4 ++-- .../nl/Excellent180.10604.10605.plus.csv | 4 ++-- .../nl/Excellent180.10606.10607.csv | 4 ++-- .../nl/Excellent180.10606.10607.plus.csv | 4 ++-- .../nl/Excellent180.10608.10706.csv | 4 ++-- .../nl/Excellent180.10608.10706.plus.csv | 4 ++-- .../nl/Excellent180.10801.10805.csv | 4 ++-- .../nl/Excellent180.10801.10805.plus.csv | 4 ++-- .../nl/Excellent180.10806.99999.csv | 4 ++-- .../nl/Excellent180.10806.99999.plus.csv | 4 ++-- .../nl/Excellent300.10502.10603.csv | 4 ++-- .../nl/Excellent300.10502.10603.plus.csv | 4 ++-- .../nl/Excellent300.10604.10605.csv | 4 ++-- .../nl/Excellent300.10604.10605.plus.csv | 4 ++-- .../nl/Excellent300.10606.10607.csv | 4 ++-- .../nl/Excellent300.10606.10607.plus.csv | 4 ++-- .../nl/Excellent300.10608.10706.csv | 4 ++-- .../nl/Excellent300.10608.10706.plus.csv | 4 ++-- .../nl/Excellent300.10801.10805.csv | 4 ++-- .../nl/Excellent300.10801.10805.plus.csv | 4 ++-- .../nl/Excellent300.10806.99999.csv | 4 ++-- .../nl/Excellent300.10806.99999.plus.csv | 4 ++-- .../nl/Excellent400.10401.10403.csv | 4 ++-- .../nl/Excellent400.10401.10403.plus.csv | 4 ++-- .../nl/Excellent400.10502.10603.csv | 4 ++-- .../nl/Excellent400.10502.10603.plus.csv | 4 ++-- .../nl/Excellent400.10604.10605.csv | 4 ++-- .../nl/Excellent400.10604.10605.plus.csv | 4 ++-- .../nl/Excellent400.10606.10607.csv | 4 ++-- .../nl/Excellent400.10606.10607.plus.csv | 4 ++-- .../nl/Excellent400.10608.10706.csv | 4 ++-- .../nl/Excellent400.10608.10706.plus.csv | 4 ++-- .../nl/Excellent400.10801.10805.csv | 4 ++-- .../nl/Excellent400.10801.10805.plus.csv | 4 ++-- .../nl/Excellent400.10806.99999.csv | 4 ++-- .../nl/Excellent400.10806.99999.plus.csv | 4 ++-- .../nl/Excellent450.10604.10605.csv | 4 ++-- .../nl/Excellent450.10604.10605.plus.csv | 4 ++-- .../nl/Excellent450.10606.10607.csv | 4 ++-- .../nl/Excellent450.10606.10607.plus.csv | 4 ++-- .../nl/Excellent450.10608.10706.csv | 4 ++-- .../nl/Excellent450.10608.10706.plus.csv | 4 ++-- .../nl/Excellent450.10801.10805.csv | 4 ++-- .../nl/Excellent450.10801.10805.plus.csv | 4 ++-- .../nl/Excellent450.10806.99999.csv | 4 ++-- .../nl/Excellent450.10806.99999.plus.csv | 4 ++-- .../nl/Flair200.10101.99999.csv | 4 ++-- .../nl/Flair225.10101.99999.csv | 4 ++-- .../nl/Flair300.10101.20105.csv | 4 ++-- .../nl/Flair300.20106.99999.csv | 4 ++-- .../nl/Flair325.10101.20105.csv | 4 ++-- .../nl/Flair325.20106.99999.csv | 4 ++-- .../nl/Flair400.10101.20105.csv | 4 ++-- .../nl/Flair400.20106.99999.csv | 4 ++-- .../nl/Flair450.10101.99999.csv | 4 ++-- .../nl/Flair600.10101.99999.csv | 4 ++-- .../nl/Nather300.10703.10706.csv | 4 ++-- .../nl/Nather300.10703.10706.plus.csv | 4 ++-- .../nl/Nather300.10801.10805.csv | 4 ++-- .../nl/Nather300.10801.10805.plus.csv | 4 ++-- .../nl/Nather300.10806.99999.csv | 4 ++-- .../nl/Nather300.10806.99999.plus.csv | 4 ++-- .../nl/RenoventElan300.10604.10605.csv | 4 ++-- .../nl/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../nl/RenoventElan300.10606.10607.csv | 4 ++-- .../nl/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../nl/RenoventElan300.10608.10706.csv | 4 ++-- .../nl/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../nl/RenoventElan300.10801.10805.csv | 4 ++-- .../nl/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../nl/RenoventElan300.10806.99999.csv | 4 ++-- .../nl/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../nl/Sky150.10504.10603.csv | 4 ++-- .../nl/Sky150.10504.10603.plus.csv | 4 ++-- .../nl/Sky150.10604.10605.csv | 4 ++-- .../nl/Sky150.10604.10605.plus.csv | 4 ++-- .../nl/Sky150.10606.10607.csv | 4 ++-- .../nl/Sky150.10606.10607.plus.csv | 4 ++-- .../nl/Sky150.10608.10706.csv | 4 ++-- .../nl/Sky150.10608.10706.plus.csv | 4 ++-- .../nl/Sky150.10801.10805.csv | 4 ++-- .../nl/Sky150.10801.10805.plus.csv | 4 ++-- .../nl/Sky150.10806.99999.csv | 4 ++-- .../nl/Sky150.10806.99999.plus.csv | 4 ++-- .../nl/Sky200.10702.10706.csv | 4 ++-- .../nl/Sky200.10702.10706.plus.csv | 4 ++-- .../nl/Sky200.10801.10805.csv | 4 ++-- .../nl/Sky200.10801.10805.plus.csv | 4 ++-- .../nl/Sky200.10806.99999.csv | 4 ++-- .../nl/Sky200.10806.99999.plus.csv | 4 ++-- .../nl/Sky300.10401.10403.csv | 4 ++-- .../nl/Sky300.10401.10403.plus.csv | 4 ++-- .../nl/Sky300.10502.10603.csv | 4 ++-- .../nl/Sky300.10502.10603.plus.csv | 4 ++-- .../nl/Sky300.10604.10605.csv | 4 ++-- .../nl/Sky300.10604.10605.plus.csv | 4 ++-- .../nl/Sky300.10606.10607.csv | 4 ++-- .../nl/Sky300.10606.10607.plus.csv | 4 ++-- .../nl/Sky300.10608.10706.csv | 4 ++-- .../nl/Sky300.10608.10706.plus.csv | 4 ++-- .../nl/Sky300.10801.10805.csv | 4 ++-- .../nl/Sky300.10801.10805.plus.csv | 4 ++-- .../nl/Sky300.10806.99999.csv | 4 ++-- .../nl/Sky300.10806.99999.plus.csv | 4 ++-- .../nl/Vitovent200W.10104.10104.csv | 4 ++-- .../nl/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../nl/Vitovent200W.10105.10105.csv | 4 ++-- .../nl/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../nl/Vitovent200W.10106.99999.csv | 4 ++-- .../nl/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../nl/Vitovent300C.10101.10105.csv | 4 ++-- .../nl/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../nl/Vitovent300C.10106.99999.csv | 4 ++-- .../nl/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../nl/Vitovent300W300.10101.10105.csv | 4 ++-- .../nl/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../nl/Vitovent300W300.10106.99999.csv | 4 ++-- .../nl/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../nl/Vitovent300W400.10101.10105.csv | 4 ++-- .../nl/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../nl/Vitovent300W400.10106.99999.csv | 4 ++-- .../nl/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../nl/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../nl/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../nl/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../nl/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../nl/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../nl/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../nl/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../nl/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- .../pl/CWLF250.10806.10808.csv | 4 ++-- .../pl/CWLF250.10806.10808.plus.csv | 4 ++-- .../pl/CWLF250.10809.99999.csv | 4 ++-- .../pl/CWLF250.10809.99999.plus.csv | 4 ++-- .../pl/CWLF350.10806.10808.csv | 4 ++-- .../pl/CWLF350.10806.10808.plus.csv | 4 ++-- .../pl/CWLF350.10809.99999.csv | 4 ++-- .../pl/CWLF350.10809.99999.plus.csv | 4 ++-- .../pl/CWLTower300.10603.10603.csv | 4 ++-- .../pl/CWLTower300.10603.10603.plus.csv | 4 ++-- .../pl/CWLTower300.10604.10605.csv | 4 ++-- .../pl/CWLTower300.10604.10605.plus.csv | 4 ++-- .../pl/CWLTower300.10606.10607.csv | 4 ++-- .../pl/CWLTower300.10606.10607.plus.csv | 4 ++-- .../pl/CWLTower300.10608.10706.csv | 4 ++-- .../pl/CWLTower300.10608.10706.plus.csv | 4 ++-- .../pl/CWLTower300.10801.10805.csv | 4 ++-- .../pl/CWLTower300.10801.10805.plus.csv | 4 ++-- .../pl/CWLTower300.10806.99999.csv | 4 ++-- .../pl/CWLTower300.10806.99999.plus.csv | 4 ++-- .../pl/ConstantRPM400.10505.99999.csv | 4 ++-- .../pl/ConstantRPM400.10505.99999.plus.csv | 4 ++-- .../pl/DecentralAir70.10101.10700.csv | 4 ++-- .../pl/DecentralAir70.10101.10700.plus.csv | 4 ++-- .../pl/DecentralAir70.10701.99999.csv | 4 ++-- .../pl/DecentralAir70.10701.99999.plus.csv | 4 ++-- .../pl/Elan10.10103.99999.csv | 4 ++-- .../pl/Elan10.10103.99999.plus.csv | 4 ++-- .../pl/Elan4.10104.99999.csv | 4 ++-- .../pl/Elan4.10104.99999.plus.csv | 4 ++-- .../pl/Excellent180.10503.10603.csv | 4 ++-- .../pl/Excellent180.10503.10603.plus.csv | 4 ++-- .../pl/Excellent180.10604.10605.csv | 4 ++-- .../pl/Excellent180.10604.10605.plus.csv | 4 ++-- .../pl/Excellent180.10606.10607.csv | 4 ++-- .../pl/Excellent180.10606.10607.plus.csv | 4 ++-- .../pl/Excellent180.10608.10706.csv | 4 ++-- .../pl/Excellent180.10608.10706.plus.csv | 4 ++-- .../pl/Excellent180.10801.10805.csv | 4 ++-- .../pl/Excellent180.10801.10805.plus.csv | 4 ++-- .../pl/Excellent180.10806.99999.csv | 4 ++-- .../pl/Excellent180.10806.99999.plus.csv | 4 ++-- .../pl/Excellent300.10502.10603.csv | 4 ++-- .../pl/Excellent300.10502.10603.plus.csv | 4 ++-- .../pl/Excellent300.10604.10605.csv | 4 ++-- .../pl/Excellent300.10604.10605.plus.csv | 4 ++-- .../pl/Excellent300.10606.10607.csv | 4 ++-- .../pl/Excellent300.10606.10607.plus.csv | 4 ++-- .../pl/Excellent300.10608.10706.csv | 4 ++-- .../pl/Excellent300.10608.10706.plus.csv | 4 ++-- .../pl/Excellent300.10801.10805.csv | 4 ++-- .../pl/Excellent300.10801.10805.plus.csv | 4 ++-- .../pl/Excellent300.10806.99999.csv | 4 ++-- .../pl/Excellent300.10806.99999.plus.csv | 4 ++-- .../pl/Excellent400.10401.10403.csv | 4 ++-- .../pl/Excellent400.10401.10403.plus.csv | 4 ++-- .../pl/Excellent400.10502.10603.csv | 4 ++-- .../pl/Excellent400.10502.10603.plus.csv | 4 ++-- .../pl/Excellent400.10604.10605.csv | 4 ++-- .../pl/Excellent400.10604.10605.plus.csv | 4 ++-- .../pl/Excellent400.10606.10607.csv | 4 ++-- .../pl/Excellent400.10606.10607.plus.csv | 4 ++-- .../pl/Excellent400.10608.10706.csv | 4 ++-- .../pl/Excellent400.10608.10706.plus.csv | 4 ++-- .../pl/Excellent400.10801.10805.csv | 4 ++-- .../pl/Excellent400.10801.10805.plus.csv | 4 ++-- .../pl/Excellent400.10806.99999.csv | 4 ++-- .../pl/Excellent400.10806.99999.plus.csv | 4 ++-- .../pl/Excellent450.10604.10605.csv | 4 ++-- .../pl/Excellent450.10604.10605.plus.csv | 4 ++-- .../pl/Excellent450.10606.10607.csv | 4 ++-- .../pl/Excellent450.10606.10607.plus.csv | 4 ++-- .../pl/Excellent450.10608.10706.csv | 4 ++-- .../pl/Excellent450.10608.10706.plus.csv | 4 ++-- .../pl/Excellent450.10801.10805.csv | 4 ++-- .../pl/Excellent450.10801.10805.plus.csv | 4 ++-- .../pl/Excellent450.10806.99999.csv | 4 ++-- .../pl/Excellent450.10806.99999.plus.csv | 4 ++-- .../pl/Flair200.10101.99999.csv | 4 ++-- .../pl/Flair225.10101.99999.csv | 4 ++-- .../pl/Flair300.10101.20105.csv | 4 ++-- .../pl/Flair300.20106.99999.csv | 4 ++-- .../pl/Flair325.10101.20105.csv | 4 ++-- .../pl/Flair325.20106.99999.csv | 4 ++-- .../pl/Flair400.10101.20105.csv | 4 ++-- .../pl/Flair400.20106.99999.csv | 4 ++-- .../pl/Flair450.10101.99999.csv | 4 ++-- .../pl/Flair600.10101.99999.csv | 4 ++-- .../pl/Nather300.10703.10706.csv | 4 ++-- .../pl/Nather300.10703.10706.plus.csv | 4 ++-- .../pl/Nather300.10801.10805.csv | 4 ++-- .../pl/Nather300.10801.10805.plus.csv | 4 ++-- .../pl/Nather300.10806.99999.csv | 4 ++-- .../pl/Nather300.10806.99999.plus.csv | 4 ++-- .../pl/RenoventElan300.10604.10605.csv | 4 ++-- .../pl/RenoventElan300.10604.10605.plus.csv | 4 ++-- .../pl/RenoventElan300.10606.10607.csv | 4 ++-- .../pl/RenoventElan300.10606.10607.plus.csv | 4 ++-- .../pl/RenoventElan300.10608.10706.csv | 4 ++-- .../pl/RenoventElan300.10608.10706.plus.csv | 4 ++-- .../pl/RenoventElan300.10801.10805.csv | 4 ++-- .../pl/RenoventElan300.10801.10805.plus.csv | 4 ++-- .../pl/RenoventElan300.10806.99999.csv | 4 ++-- .../pl/RenoventElan300.10806.99999.plus.csv | 4 ++-- .../pl/Sky150.10504.10603.csv | 4 ++-- .../pl/Sky150.10504.10603.plus.csv | 4 ++-- .../pl/Sky150.10604.10605.csv | 4 ++-- .../pl/Sky150.10604.10605.plus.csv | 4 ++-- .../pl/Sky150.10606.10607.csv | 4 ++-- .../pl/Sky150.10606.10607.plus.csv | 4 ++-- .../pl/Sky150.10608.10706.csv | 4 ++-- .../pl/Sky150.10608.10706.plus.csv | 4 ++-- .../pl/Sky150.10801.10805.csv | 4 ++-- .../pl/Sky150.10801.10805.plus.csv | 4 ++-- .../pl/Sky150.10806.99999.csv | 4 ++-- .../pl/Sky150.10806.99999.plus.csv | 4 ++-- .../pl/Sky200.10702.10706.csv | 4 ++-- .../pl/Sky200.10702.10706.plus.csv | 4 ++-- .../pl/Sky200.10801.10805.csv | 4 ++-- .../pl/Sky200.10801.10805.plus.csv | 4 ++-- .../pl/Sky200.10806.99999.csv | 4 ++-- .../pl/Sky200.10806.99999.plus.csv | 4 ++-- .../pl/Sky300.10401.10403.csv | 4 ++-- .../pl/Sky300.10401.10403.plus.csv | 4 ++-- .../pl/Sky300.10502.10603.csv | 4 ++-- .../pl/Sky300.10502.10603.plus.csv | 4 ++-- .../pl/Sky300.10604.10605.csv | 4 ++-- .../pl/Sky300.10604.10605.plus.csv | 4 ++-- .../pl/Sky300.10606.10607.csv | 4 ++-- .../pl/Sky300.10606.10607.plus.csv | 4 ++-- .../pl/Sky300.10608.10706.csv | 4 ++-- .../pl/Sky300.10608.10706.plus.csv | 4 ++-- .../pl/Sky300.10801.10805.csv | 4 ++-- .../pl/Sky300.10801.10805.plus.csv | 4 ++-- .../pl/Sky300.10806.99999.csv | 4 ++-- .../pl/Sky300.10806.99999.plus.csv | 4 ++-- .../pl/Vitovent200W.10104.10104.csv | 4 ++-- .../pl/Vitovent200W.10104.10104.plus.csv | 4 ++-- .../pl/Vitovent200W.10105.10105.csv | 4 ++-- .../pl/Vitovent200W.10105.10105.plus.csv | 4 ++-- .../pl/Vitovent200W.10106.99999.csv | 4 ++-- .../pl/Vitovent200W.10106.99999.plus.csv | 4 ++-- .../pl/Vitovent300C.10101.10105.csv | 4 ++-- .../pl/Vitovent300C.10101.10105.plus.csv | 4 ++-- .../pl/Vitovent300C.10106.99999.csv | 4 ++-- .../pl/Vitovent300C.10106.99999.plus.csv | 4 ++-- .../pl/Vitovent300W300.10101.10105.csv | 4 ++-- .../pl/Vitovent300W300.10101.10105.plus.csv | 4 ++-- .../pl/Vitovent300W300.10106.99999.csv | 4 ++-- .../pl/Vitovent300W300.10106.99999.plus.csv | 4 ++-- .../pl/Vitovent300W400.10101.10105.csv | 4 ++-- .../pl/Vitovent300W400.10101.10105.plus.csv | 4 ++-- .../pl/Vitovent300W400.10106.99999.csv | 4 ++-- .../pl/Vitovent300W400.10106.99999.plus.csv | 4 ++-- .../pl/Vitovent300WH32SA225.10101.10109.csv | 4 ++-- .../pl/Vitovent300WH32SA225.10110.10110.csv | 4 ++-- .../pl/Vitovent300WH32SA225.10111.99999.csv | 4 ++-- .../pl/Vitovent300WH32SA600.10101.99999.csv | 4 ++-- .../pl/Vitovent300WH32SC325.10101.10110.csv | 4 ++-- .../pl/Vitovent300WH32SC325.10111.99999.csv | 4 ++-- .../pl/Vitovent300WH32SC400.10101.10110.csv | 4 ++-- .../pl/Vitovent300WH32SC400.10111.99999.csv | 4 ++-- src/ebus_message.py | 4 ++-- 1156 files changed, 2312 insertions(+), 2312 deletions(-) diff --git a/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv index d30e2bf2..97ac3395 100644 --- a/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv @@ -15,8 +15,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/de/3c.Sky300.csv b/ebusd-configuration-known-slave-address/de/3c.Sky300.csv index acb7bfd5..554fc901 100644 --- a/ebusd-configuration-known-slave-address/de/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/de/3c.Sky300.csv @@ -15,8 +15,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv index ebb62108..b417f425 100644 --- a/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv @@ -15,8 +15,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv index 1a28c8ae..2283f46f 100644 --- a/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv @@ -17,8 +17,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/en/3c.Sky300.csv b/ebusd-configuration-known-slave-address/en/3c.Sky300.csv index 9687e310..ace7a9aa 100644 --- a/ebusd-configuration-known-slave-address/en/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/en/3c.Sky300.csv @@ -17,8 +17,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv index 7c0a4666..4256c4aa 100644 --- a/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv @@ -17,8 +17,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv index 07f0e173..65110996 100644 --- a/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv @@ -15,8 +15,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/es/3c.Sky300.csv b/ebusd-configuration-known-slave-address/es/3c.Sky300.csv index 246d2184..0a8165e5 100644 --- a/ebusd-configuration-known-slave-address/es/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/es/3c.Sky300.csv @@ -15,8 +15,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv index 110d5f06..edc4465e 100644 --- a/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv @@ -15,8 +15,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv index 10811c43..c6c92f81 100644 --- a/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv @@ -15,8 +15,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv b/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv index 72ae5da4..f635acb9 100644 --- a/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv @@ -15,8 +15,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv index 56e41cbe..d7b37d18 100644 --- a/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv @@ -15,8 +15,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv index 43c37ac3..11eee3cf 100644 --- a/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv @@ -15,8 +15,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/it/3c.Sky300.csv b/ebusd-configuration-known-slave-address/it/3c.Sky300.csv index c687d16e..4c03d815 100644 --- a/ebusd-configuration-known-slave-address/it/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/it/3c.Sky300.csv @@ -15,8 +15,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv index edc5ae0a..147b28e7 100644 --- a/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv @@ -15,8 +15,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv index 40d0455b..6ab50481 100644 --- a/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv @@ -17,8 +17,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv b/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv index f93604aa..e89cdd56 100644 --- a/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv @@ -17,8 +17,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv index 8face426..bedaadf1 100644 --- a/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv @@ -17,8 +17,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv index 55ed8b41..2a04e518 100644 --- a/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv @@ -17,8 +17,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv b/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv index e7730e1f..5b08defa 100644 --- a/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv @@ -17,8 +17,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv index 42b2035b..4f86215a 100644 --- a/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv @@ -17,8 +17,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv index ea6015be..ecaa48d7 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv index 91a3cc07..da28cc52 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv index 4dc0a375..085b24bd 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv index 79e1654e..4bc1f8be 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv index 45793b3d..424bab07 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv index 6c47b395..c0bafde1 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv index 3dbb4656..1ca54781 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv index f960b600..e56c774d 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv index 337470de..08cfbecf 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv index 337470de..08cfbecf 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv index 24e41368..75da9c3c 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv index 24e41368..75da9c3c 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv index ab62d926..858bd014 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv index ab62d926..858bd014 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv index 43ea3410..e84ce667 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv index 43ea3410..e84ce667 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv index 0b14322a..1b206ae7 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv index 4d5c40c5..5a1b7709 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv index 6d9b208f..20d44eba 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv index 840e78ed..e4cd72fa 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv index a6c2e96d..f1daef25 100644 --- a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv index a6c2e96d..f1daef25 100644 --- a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv index e7beb80f..27cd98fc 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv index d5376f91..67d6b240 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv index 11fce51f..b6d9ee29 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv index aa89a1b3..27fc95c9 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv index 18b301db..6c37a57d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv index 18b301db..6c37a57d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv index 7c67d617..5dc57649 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv index 115e6746..295e6c55 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv index 2cd6fee8..edc0e1a2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv index 3a4ee5d4..339c8779 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv index 3d28b4ed..6ea0dba9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv index e84bfcfd..b212bd20 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv index 00a45323..c4b55a78 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv index 14ff484e..720c22d1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv index 957b909b..af9607f2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv index 6059166f..8b5b1ca9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv index 10fa3e3d..802c27ca 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv index 0c2a45ec..456be51b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv index 8302b999..cd7e927c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv index 93a209c2..ce4a84e8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv index 3870b307..14049ed7 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv index 1c03eae7..c8f64d1a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv index e836651e..a90b0734 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv index 008c4ea7..da64974f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv index c1c5499c..ca665d00 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv index 72d070b5..8944928d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv index 05dab1ca..ddbdccb9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv index c8c48f40..54fec1ef 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv index 044706a5..e9f98835 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv index 20c0064b..5f6508c2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv index 13063edc..f771adb4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv index 08633071..1b9f30a8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv index db62e266..416b4d02 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv index 37b9b5a8..faf00c8b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv index d7dedcdc..819230ff 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv index 82be32eb..b526cb44 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv index f021171f..57d6b683 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv index bbfc49cd..130bcf97 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv index 3eaa8d4d..0c7cf033 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv index 1846c471..4fa3e35f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv index d0fa16b4..c598bf4f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv index 43e42587..22e21f21 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv index 1c23a46e..a32e2f0d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv index 38b3a959..b92504a3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv index e5b562e1..e4854b19 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv index 95ec46e9..fcc95471 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv index 630771a7..0d0e15f4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv index 8c2a02a8..2630cc10 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv index 7f5da355..efbb4624 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv index d9f2b563..cd483302 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv index 10011ca5..e1d94b1a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv index f1e34f4d..a3643c6d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv index 0315ae43..b41582e1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv index 3ce7cc86..562b03d3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv index b24128d8..49dc3e2f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv index 8ac32815..deab0e02 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv index 4d627b01..3d77553a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv index 32b2d8eb..8bcbe617 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv index f51e6184..b19bcb6b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv index 0730b63a..693e60d3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv index 03481aaf..bf9d27df 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv index f1b9ad00..244323b1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv index cc54f939..28c63229 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv index c200388e..3b707951 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv index 4aece527..b257d892 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv index 5a7b6c18..b9a32574 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv index 6f056553..05968e0f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv index 6f056553..05968e0f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv index 836d5cc6..6186db3d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv index 781b8569..b0f1c501 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv index c0ca8c03..88abfef0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv index c0ca8c03..88abfef0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv index 6adf8a85..6d66fcca 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv index aa8024b7..bd06cbea 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv index 1ba5e077..5179c3b8 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv index 9c9fb4b4..773c4b48 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv index a609df78..958b2050 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv index e7ddf341..9c24033f 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv index b0bfacc7..3cdea785 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv index 13e54062..6c22d9c0 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv index 752525bf..babcc540 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv index 63f13047..b6dc73c1 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv index caae37dc..26107e1b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv index 514c520d..a3ecde89 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv index ee42c8aa..bffa7d9a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv index b7d8238d..f7f578c6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv index 0d8f74bb..28380c4d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv index 744fdbdc..f1595f8a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv index 4d14476a..b1b51492 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv index 138f4547..6bc048e8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv index 70f3229e..380f3674 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv index 4b738547..afebe06b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv index 9e12df8c..57b98ca2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv index 12022d1e..be6555d4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv index ad2230dd..1dfb1eb9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv index 337c9f58..671cde11 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv index fcee2575..ac932535 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv index 1a2ce1ad..8c13a319 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv index aaa7c36e..bde483bf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv index dacf7338..11d97d9b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv index 76c8ed2d..7c281603 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv index 38ac9506..29b8e1a9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv index 256e88fd..8c948f37 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv index 87e915ca..99c0063b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv index 72a0af6b..1ebe7f7c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv index 1bd27f37..c24665a1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv index 4890d061..0c43b9b7 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv index 387b6d24..d2b37265 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv index 4fbf068a..d9132357 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv index 73f3e531..bcd70479 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv index 3e4a66d7..3c5fbd9b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv index 7075c01e..26b564bf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv index 3ff79d30..6dcdbba0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv index 22a8f8e9..730f0348 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv index 5c72de11..4cec7d7d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv index 5c72de11..4cec7d7d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv index 225b1b1b..e80a4095 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv index 225b1b1b..e80a4095 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv index 8356cbfa..4bab9ed6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv index 8356cbfa..4bab9ed6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv index 7e69e177..91d13c54 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv index f389d7a5..6212d969 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv index 72e26f9e..077608c8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv index 2ca43402..e923ca1a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv index 21364904..0c043d57 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv index 8e470828..dbee554f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv index 9fe236ac..c87af37d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv index e5018c4a..a623ccb4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv index 1e67d2a8..b88f2adc 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv index d19faa6d..c9573f3b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv index 40b9f8a6..4887a056 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv index 8c7c1122..35bb01c4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv index fc810ace..3929f3c6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv index 031ec577..4b3a0e9e 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv index 889743bd..717fc70a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv index 90711232..d7777380 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv index 4947512c..5bfb97bb 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv index 50b454e3..cc0abafa 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv index 792f621a..0c168179 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv index 869f4828..c0a6d44f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv @@ -20,8 +20,8 @@ w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, -w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorbetriebAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,MaximalerDurchsatzFilter,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filterverwendung,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv index 5f103ead..59938ea1 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv index 081fbd5f..19476ef9 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv index 0f53eadb..194486cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv index 886f974c..f74212d2 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv index 0d2f79a1..c98f4e0a 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv index 3c30d8be..122b84d2 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv index 8ca496af..75c3cc65 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv index ed38cca8..cad1ec2c 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv index 84a0fa3d..262423ca 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv index 84a0fa3d..262423ca 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv index eb06de12..ea48fa24 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv index eb06de12..ea48fa24 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv index 7baca4ee..27ecebe0 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv index 7baca4ee..27ecebe0 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv index cac00eb8..989292ad 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv index cac00eb8..989292ad 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv index d849cdc4..4bb0d8cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv index bc2ab8d3..8f6dc745 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv index 65b937e6..6a2d19d4 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv index 7c5d352f..501e51e3 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv index 719f42e7..f2748d41 100644 --- a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv index 719f42e7..f2748d41 100644 --- a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv index d7026cda..f0984af2 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv index b66fcfc2..0c38d346 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv index 99ccd91d..c09c4e00 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv index d1ad7d75..295dfa68 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv index bace4617..e154a754 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv index bace4617..e154a754 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv index 65282713..9792f4dd 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv index b6124eee..4d6bfdaa 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv index 4802a478..00a041ee 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv index b47a0335..d4f5006a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv index 2ff17ce6..28a80141 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv index bafe258a..fcecbf47 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv index e7ee6563..8ee5a481 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv index 62356fef..82411f34 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv index 77615d92..8e9ab3d1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv index f4bd7c2c..a121d206 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv index f7d85d9a..2a2fa7e1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv index db1ec083..d25ae6a9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv index 5a80713f..e8b2a142 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv index 611b68b1..152240bb 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv index cc7eae7f..8fbb37b0 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv index 967c1e7e..70aed90e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv index b2ba9987..634d7479 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv index 7059686e..85a7821b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv index f6d814b7..845073c9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv index 56c54c68..268fd659 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv index 92c5efb0..58ebf9cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv index e56bb5b2..717a5fd7 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv index 655ae4a8..c1701c77 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv index 0875b617..5e9866ed 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv index 28c66a9f..2fc3d4f2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv index cf330402..3b4c506c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv index 7a7eed46..28df74f6 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv index 7a01eb23..621f4906 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv index 04da4d32..f863a90a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv index e582d853..e8cc0e0a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv index 6f1a00a0..0dd1bb74 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv index 4797ab75..50b90b39 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv index f22a1977..70b14c43 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv index 85d90729..350d40f8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv index 87c2d06c..c2118151 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv index 4c4e1119..e3974dc5 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv index 6c064781..9c8fc53f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv index 2115e035..aa087818 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv index 48fe449c..171767ee 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv index 386904b3..ad53fe8e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv index 7214a03d..45eede2c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv index de62476c..414c6291 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv index 6052ebc1..f7813cb3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv index ca97e9e5..264c0378 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv index c7e12707..4f8506d8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv index 482496f4..5b3e117f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv index acfe7cc5..0f09b4e2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv index 23ea4edd..3c16d7d0 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv index 5d386dcd..96f1e33f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv index 797eee74..2be7642e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv index 5ca856b7..154b1a6d 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv index f12c7a08..7630398b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv index 608fdc08..feede06f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv index 096bb847..2ed6b33c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv index 5953f771..01d36ae2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv index 4aaf70ec..f7c28db8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv index 17ab5099..1d2d1794 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv index b3050b45..e5a0b548 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv index 0800d9b8..3caf06cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv index 37ba95f4..7db79a7a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv index 7b8653a6..b933c499 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv index 7b8653a6..b933c499 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv index 0d9e5f2a..a89bc215 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv index f3322085..6a7c5c60 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv index 62a3ecb4..ebea83b2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv index 62a3ecb4..ebea83b2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv index b6ee1184..9606a415 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv index ea39c597..6db630cf 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv index a06bbade..ed860441 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv index 8091c214..288e4b91 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv index a51a8fcc..8dbf311c 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv index 5bf1ea63..b2e7d920 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv index 2df9f30c..2b4bda2e 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv index c3099600..076339bf 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv index 310520dd..1d347a5f 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv index 602776f9..cae6e895 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv index 1e5ac1cf..59f4b4a1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv index 36f2e821..9abb280f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv index b30e0d33..4ab73ccc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv index ee48bb62..3468d93b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv index 33ed7a83..922ec2a3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv index eb136af1..a5ac4faa 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv index dc7920ab..cfe6ea68 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv index 3091303a..a116a69c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv index 090e8a10..e1824dfd 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv index 1bfa7963..604506d2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv index 52c8c6a2..51b696cf 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv index 107fdfe1..d3749b6b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv index 765ee53c..9b063884 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv index 80ccb18b..4b52037c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv index 68808b9b..2fbef8eb 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv index 4a5c68bd..7db0a77c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv index d60f3ea4..a0bb1ee4 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv index dfbdcd99..255d2c7c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv index d6850b92..9f980538 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv index 69d63546..e360bd89 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv index 87660c3c..3fa35b95 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv index 2b302e8e..f66c2319 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv index e0bdc1a6..7f7c4c86 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv index 432c4638..7027320a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv index 88f993a9..f7f14302 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv index 252bc780..b3bc664c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv index 28d6b97a..87e52f21 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv index d5ba7dee..43b02fde 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv index 4ea0872f..be838d50 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv index d4ee5e84..19580e5e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv index b77208ea..13041cbc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv index d2ce7bf1..c97e88b6 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv index cf3a960f..52062172 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv index cf3a960f..52062172 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv index 03ddfe70..449b2495 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv index 03ddfe70..449b2495 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv index 590a2bf9..72b76254 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv index 590a2bf9..72b76254 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv index 0c01e3d6..3d90050b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv index 9c3d261b..fbc085a8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv index c826e411..ecd92d81 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv index 7f7e8123..b0907368 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv index 76384d49..87efff8e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv index 05dd986b..d955233e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv index 05ec7234..de4c52e1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv index d66edc7d..bba40f0b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv index f1c327c6..ec4f52a9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv index 6da87cd0..e3488fcb 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv index 7c5e79df..a99687cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv index c3a5b60e..4afc5704 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv index 9ab0da87..928b8898 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv index 15b54a63..2a7e07f1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv index 45842205..cee0d15f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv index f9f7cdc3..c1a9579e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv index 1ee6879c..005db8e2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv index c0226d4e..e27e2f59 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv index 99234b7d..f2d3b1c9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv index 1c07e607..8c00a379 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv @@ -22,8 +22,8 @@ w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, -w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,FanModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumFlow,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,FilterUsage,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv index 7ac35c10..eca20c1f 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv index e9aa57b8..baca14f9 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv index b051e74e..8531c8a1 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv index 940390bd..10b5c885 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv index f268fcc8..5ef39f77 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv index 37a9fa58..e5d3603b 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv index cf96ced3..76a1594e 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv index 6e2258a5..81653b5e 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv index f8c7fbea..a205af88 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv index f8c7fbea..a205af88 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv index 848b68ab..b8adae13 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv index 848b68ab..b8adae13 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv index 9d5a9c64..c7beb898 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv index 9d5a9c64..c7beb898 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv index 0dc67771..6c0b67cc 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv index 0dc67771..6c0b67cc 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv index 61b4bde6..8bd3f9e6 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv index 6d21fe09..0283a3d8 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv index f852093e..9dcd93ae 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv index ad11122a..bdd3c652 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv index 061867df..e7d5f944 100644 --- a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv index 061867df..e7d5f944 100644 --- a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv index 7e4de305..24271c2e 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv index beef96ed..62d3c970 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv index bb33e357..ff49611e 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv index 39f9f7f6..c24f770b 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv index f3cb1100..3cafeb29 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv index f3cb1100..3cafeb29 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv index 31f94a65..f5a6b2ee 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv index 7996ae21..25d021f4 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv index 91690f0e..de8761b2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv index dc5e24ab..dae40726 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv index 9498f1ab..f732e6d1 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv index 1a3e874c..d321d6ab 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv index c66e0da8..40883fb0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv index 02daf110..df3990bb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv index 11bc482c..7ab6c2ca 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv index fb8c34d8..23822a91 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv index 73c5757c..61d1c654 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv index 9e959ba8..884131a6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv index 2aab2f42..dd50f621 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv index 8d1dd9f4..d80ebbed 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv index d8f23915..a76fb05c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv index 9e7c2ab2..32bca20b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv index 78fe79d6..93aa5a76 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv index 787b7b2b..80e315bb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv index 0ed01b34..400db68e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv index 8af579bf..408ad599 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv index 750da9e9..0f89eb56 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv index 6d570130..cad4f290 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv index 22521d4e..7a48211f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv index c301acb9..b003032a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv index 8c213109..13f63c95 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv index d498bb65..7d48ced7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv index 4f774f47..6212d736 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv index 6220be4b..01107285 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv index 55341ff6..faee2898 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv index e81c35b3..149e9857 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv index 8f1250fb..dc046c83 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv index e40ed304..55f81270 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv index fc4dd584..fef3fac1 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv index 98f92985..aec9d131 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv index 17d00f8f..9344e262 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv index 3f0786d3..dd61ff64 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv index 2c669744..1d9e4692 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv index 9b978f61..63c9dc6b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv index b2ec7c48..71b27420 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv index e3173e64..d84423d5 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv index d36f0bef..dde5388f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv index 7ae196ca..6bb45c64 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv index 72eb916e..5a8f35c4 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv index c23af534..e963e7c3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv index 77e57a33..f1264e06 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv index d617d14b..484af153 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv index 04aa5c77..4a8fc8d7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv index 487c0c6d..f7ed7c7b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv index 6fcbb6ac..18be98e5 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv index c93abd4d..71b4f08f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv index 27c5c539..651a1b76 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv index bba9e817..1bc02bf8 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv index 8ed15f2c..3e0ab490 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv index ae11e044..62b08a81 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv index b86c72f5..668e311a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv index e98b0c68..3857bbe7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv index 350cd3f5..b0144da5 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv index 34c3c3a7..19aa50a9 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv index 96ee504b..3fb50d66 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv index 6947b93e..14a25eb8 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv index 15264b10..9a94e73d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv index 15264b10..9a94e73d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv index 16cbb35c..26280851 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv index c1cfc31a..1a0a886c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv index 66f9c927..6f0405d3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv index 66f9c927..6f0405d3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv index b2218fbf..c45ff257 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv index 0ac70874..e42891fa 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv index 44ede4ed..0b047b42 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv index ec781698..ee092a96 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv index 218f71ba..a480eff9 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv index 8b42bf6d..01b9d1ad 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv index 3358b705..1e9e8ded 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv index 0a5010b1..e24de20d 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv index 57ff034e..049d075a 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv index 66980e05..434e8034 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv index f1fbd73b..ea11d12a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv index 4b80f6cf..60561c32 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv index ed6df127..0b7376cd 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv index db184e92..fd977dad 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv index 12b3e54b..c707a4dd 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv index f8b98afa..b3ee56a8 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv index 15ca76a0..41cb5d65 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv index 3ca19855..7924b1ee 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv index dc9a6900..11883665 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv index 43ab36b8..28102d1f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv index 9fa54178..fc0a6cee 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv index 6ca01465..32b5b3d7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv index 6597d342..38383058 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv index 3a9bcccd..316bb34c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv index 1d70a16f..44557be0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv index eeb263cc..14d5d0e8 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv index 32985249..550e7650 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv index 81b37673..16d0bc59 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv index e7e11344..e1e59934 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv index 4c08ee4d..6dfb700f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv index 8faa6002..b6658930 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv index fd830a33..8389ab04 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv index b35ca6e9..727f8632 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv index 8c292df2..f0df9c40 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv index 1da2f213..f880e620 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv index 96599aba..447f33ac 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv index 3e98fb75..d0549085 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv index c756e4d6..6937cb12 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv index e045609c..cf27f399 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv index 5519d56a..39e21027 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv index 0111995b..3579d51c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv index 7886ee57..3c4d8b74 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv index 3d61de6e..27a5e5d6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv index 3d61de6e..27a5e5d6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv index 8b5f2c19..3c89bb25 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv index 8b5f2c19..3c89bb25 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv index 44f641d5..f04efa77 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv index 44f641d5..f04efa77 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv index ce774cac..5cb988d3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv index f6cf5732..fe796d45 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv index 9ffe5a95..b16d6530 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv index 670644f8..e5d53faa 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv index 879fee9a..1a045f41 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv index 495595a2..53704fca 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv index 904a9551..2e967d01 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv index bf288ca7..300cd963 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv index 8d100d46..84d2842d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv index a28a3b91..841ed683 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv index bb5889cd..aa207e36 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv index 4e3fb4b5..0221167c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv index 34ed5e33..738878ac 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv index 53d7ec13..10a70e10 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv index 85ca3efd..c31c08d0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv index 3f7a3e25..6254bcfa 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv index 87dfd09b..e5ed4cf3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv index 26bf36e6..69bb2c5e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv index 24b5b7e6..ef670dec 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv index ce3f510f..fdcf8351 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv @@ -20,8 +20,8 @@ w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModoDeVentiladorAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlujoMáximoDeFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UsoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv index 054d2793..8391584a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv index 91a18728..d5ffd4f8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv index 1b0d4893..922abd60 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv index c275d5a8..fdf15863 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv index 5865d0b8..6a86fe2e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv index d1050d2b..e5d983d7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv index 4f8c26d6..18b543af 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv index e8ae28a4..9d364f73 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv index c79771f1..b172c439 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv index c79771f1..b172c439 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv index 0acbb989..9f5f05ac 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv index 0acbb989..9f5f05ac 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv index fa727fdd..0160629a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv index fa727fdd..0160629a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv index 9c060519..cc804ca2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv index 9c060519..cc804ca2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv index f9d8f77d..3892a977 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv index e6fcad9a..934a042b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv index fea48647..d453967d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv index 3a8fa536..9fef0cc5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv index d7d8726e..d5e38a2f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv index d7d8726e..d5e38a2f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv index 5d38152c..253d82d6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv index 8b32e3c2..caa6a7af 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv index cba4d104..a6ba390e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv index 7fa4e661..96b8f024 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv index 2ec93d23..a760286f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv index 2ec93d23..a760286f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv index c9e3ab6a..467159aa 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv index 51b09f90..9eea22b9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv index c90f50b7..dd15218e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv index f394cc01..9ce2b45c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv index 89354cfa..6e874d0e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv index b5dcdcec..8352854f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv index d2bd9b09..460b422e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv index 15b60f9c..0d9f2af1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv index 34ddef1a..a53b9948 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv index 2083943e..f4dd7b3f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv index 2c07d880..dda15250 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv index f029310f..26278565 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv index b3b7eac5..5be3c223 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv index 979a3f3c..8de4960e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv index 8c885f71..ca25dcee 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv index baa0b721..e0b1ce10 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv index 75045ed9..13d366ca 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv index 06ef1e1e..2f5fd44a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv index 31f035ae..feca4ba3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv index 4c47bf76..5710966b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv index 4d5587ae..fc1d6d6a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv index 5569da62..517f6746 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv index cbef5c6b..367883e0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv index 280e2458..068b1c0c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv index 95a49fbf..2d8aa55e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv index c483f5f8..72bb339d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv index 653563de..654b2d34 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv index d17256d9..4f250ed2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv index 05a6b76e..3c1e064b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv index 9e610409..69297bae 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv index 0f23da9b..ef9d9cf9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv index 2436e12f..560a43ff 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv index 8b405138..bc144215 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv index 712da02c..3e69b29d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv index 9ba00fe2..dde8c721 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv index dfd1f798..9a8c4671 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv index 621f59a5..f69b95c9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv index abba5802..bf276b32 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv index 313a98b3..361121e9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv index 1e970a29..615f62af 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv index 80351c45..0aaccd9f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv index f499cbb7..4a5807dc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv index d150c4b4..70e3862e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv index 2e205aad..f8fd83c6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv index b043ecbb..1fbd5424 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv index f2f187f7..3046c6f5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv index 8dd942c3..ab058983 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv index d2a056cc..291db724 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv index 716cb170..e69ac6e1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv index 9d7fbeb0..39cf1c8b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv index 324ff3a6..e5e46f65 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv index 7459e720..2b38a8c8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv index d3c777b1..ffac4868 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv index 2b523b2d..2b9334b5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv index a8c93c55..3882b741 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv index b58a5266..cc2a04b9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv index 359594b9..9ce0ddb0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv index 7f9161bb..9a3eb503 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv index 34649402..d037a82c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv index 7ee65512..bedfd4c6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv index 882421b2..d47710ad 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv index 882421b2..d47710ad 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv index 2e96534d..7f0c598b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv index e367e52c..467eb613 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv index 0d0405df..b286278c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv index 0d0405df..b286278c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv index de6a63ff..3c6d119b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv index cb5a23d8..e873af16 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv index 37353175..bbb2a48e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv index dd7d114f..6c66e087 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv index ac9b0fb6..8d93fc0a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv index 4138e5a7..a4db99d9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv index 025c0ab1..c8beb1e5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv index 1a804e29..06200274 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv index b467cab0..45280f12 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv index 8791b3c3..adabc1cc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv index aa6bf731..729d4223 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv index bab5b8e6..5dd85fe2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv index 3bac4379..e5b90913 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv index ad0cd834..56af6f94 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv index 71b8bd86..905f7add 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv index 039f41cc..2229f9ee 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv index ee09e332..3f72a686 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv index 26877054..fe733f5b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv index 18ab5f40..844743b0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv index 0b2038f2..c6679a09 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv index fff2249f..a220008f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv index ebb1e65f..7bc48ca6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv index 932a8823..0ecfe67a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv index 16e54560..0cec821f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv index f23c1c90..8fd2d7e1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv index 180fc08e..1c99fed4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv index 8c52cc51..b695e5c4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv index e1fa788a..e2a1aada 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv index d8a4f155..31f5f30e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv index 6b7da5fd..2b09a0a2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv index 6bc85b44..e56c0c5d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv index a2858561..846d154e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv index 82a04a1e..58bca8cf 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv index c6d8eb95..e09c10a1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv index 70b006db..82fdb315 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv index 7707d5f3..acbe131e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv index 22c89dcb..d88b142e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv index 534d7c02..fd06866e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv index c46b2c8a..2d58c596 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv index a1965907..926064ef 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv index 17e3b122..ae810479 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv index a34a0f57..282bfb3a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv index 554b075e..f96b84a5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv index 554b075e..f96b84a5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv index 67ca8a08..9ce5b8d2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv index 67ca8a08..9ce5b8d2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv index 7d4d9f82..9f712b6d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv index 7d4d9f82..9f712b6d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv index faf213a4..1b8b4a60 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv index bd4ac83e..d88e804f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv index e567bed5..176e1b68 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv index 1ea656c8..01b6490b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv index 3733d034..d20d0c46 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv index 7d348872..198104fa 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv index d8772bf6..1366d39f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv index 9621b8ec..06926de3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv index 09f601dd..b6367d97 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv index a64bfb6e..76f7b5a0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv index 7e1e7075..fcddc3af 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv index ad7aa336..485a44c3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv index 6d465a2e..a2710476 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv index e46fc59f..59298fa4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv index f4f092a3..9247bc5b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv index aa92eabc..db5a9149 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv index 6e380f2d..4fb12a51 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv index a2b74f46..bce2e220 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv index e8882fb7..49ba13b0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv index b90846cd..cb3854c9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv @@ -20,8 +20,8 @@ w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, -w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,ModeVentilateurAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltreFluxMaximum,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilisationDuFiltre,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv index ccbf47d8..4232df7d 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv index 00968c5b..65079418 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv index 7aba87cc..41fd9c48 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv index 144d497b..a6af0b63 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv index ff826ca4..650e3027 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv index fc5e2a4a..7ba9736a 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv index 8dad1777..156a7ac9 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv index 875c4842..9277ba81 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv index 2eddc4b4..5bdf6562 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv index 2eddc4b4..5bdf6562 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv index 628a6d9e..5e228769 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv index 628a6d9e..5e228769 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv index 1adc7a0c..23ae60b1 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv index 1adc7a0c..23ae60b1 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv index c89d9a76..15cf7ce2 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv index c89d9a76..15cf7ce2 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv index b3e591e9..6b74af95 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv index 0e4435f1..6853b8f1 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv index c7879605..134f569a 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv index fd8dc035..f463e1d4 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv index a9a764e2..3d7641ed 100644 --- a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv index a9a764e2..3d7641ed 100644 --- a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv index adc31ece..f32d9e7f 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv index eb528989..6535c0fe 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv index b0f4b7e7..f98e752a 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv index b2a40f13..5161ee3f 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv index 0014f82b..da41ee93 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv index 0014f82b..da41ee93 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv index 88104f67..4aa94cfc 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv index 0941e194..32a16335 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv index f8150668..369ced30 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv index c5a98d49..6915a535 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv index 514c4927..47e18d76 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv index 6945a14e..db5eabad 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv index d1abc216..b81c2c97 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv index 380d9fce..5cbdfa16 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv index d709ea58..3e52343d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv index c5bc340e..d25b9d33 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv index aaaec953..b49c2a31 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv index d517a7dd..aa341de0 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv index 732bb389..84efbfc7 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv index d49535be..61944d85 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv index 212dd0c5..13931bb8 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv index 6c33b4c0..0682c434 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv index e2d351c9..0220fe85 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv index fd9e3f15..843b6539 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv index affe45fe..63cc1b01 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv index c608b295..a8cb2291 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv index c7206413..fe748201 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv index 3b244e58..7a0cc5f9 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv index b536f631..474368f9 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv index 7748ba6f..7d8c8f56 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv index f35ffbfd..f23d15f2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv index 137b1a4e..a04b181b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv index c168d1c0..6d594d15 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv index 6115ba29..af48478b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv index f6771b4a..bbe997c2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv index 7b0293a2..6792f004 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv index 4260ce36..97bc8ef9 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv index 30d2148c..47210dca 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv index 98b4324f..2f97e450 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv index 0ec8f53b..9e2444f1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv index aecaf8d7..bfd2b8b7 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv index a1751276..acce2e8b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv index 6a5a75f2..75f45024 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv index c9ad0e15..92a644f0 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv index 5e2cef63..3685d904 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv index e06bbcaa..865c580a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv index b3ae74cc..a1adbd78 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv index bb7b8f75..7716c7a2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv index 3c0f857e..82ff2fee 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv index 397ba37d..830f2a62 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv index 4fbd4bab..d84dfbaa 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv index 80326cc3..58452e7b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv index 252c62d7..82fb7781 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv index 45bca98c..d67958dd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv index b5a5f57d..3ac31c0d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv index 8825798f..56197147 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv index 0058c509..0e22e45a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv index 39b55de3..4afa7795 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv index 72cf561c..7a86aeaf 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv index 6bb87c8d..976c6af3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv index 06cd5211..0129c0df 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv index f9a3ac81..08762d35 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv index 45fce399..3964c492 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv index 6dd53845..3df8df95 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv index 8c094be6..80075efa 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv index b2c5c972..9c59d5b2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv index 3b950a9c..7dabdf3d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv index 3b950a9c..7dabdf3d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv index 6dee216f..a7981c99 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv index 915d2ddf..5737d19f 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv index b20a4899..8d8c40ff 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv index b20a4899..8d8c40ff 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv index 5cc56416..97bdc118 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv index f1e4717e..01c4085a 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv index d5b901a0..f6134c43 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv index c2e6c42a..229b34f8 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv index eca0bc85..ea91054d 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv index e38be664..a8f7cfc9 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv index 278ae4c1..6c8b7aa6 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv index f3427c35..282c8aef 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv index 4e09c564..e9070530 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv index ed9cd217..29c2fc31 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv index 02d53c8d..676ba108 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv index 526cbb2d..2ec93c23 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv index 4232c743..807052fd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv index eb76ac0f..94b7ba13 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv index a2f10db3..c36f50bd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv index e156afc3..b4eae664 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv index 7e93a8cf..7a782e51 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv index 8765515f..cd0f2471 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv index 75da0eb9..7ae26f61 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv index 696dba75..769f2ef6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv index 3416b3b2..25e08bae 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv index 1d49362f..5427e6c4 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv index b1effc76..ec0ae4ff 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv index 79668ba0..a12e11b2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv index c6fd86c0..7364039e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv index ec0af16b..93ab3f24 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv index 9023e57a..82399830 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv index 176e8846..5f765b06 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv index 617931d4..a7bea513 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv index e621bd34..8def33b6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv index 10b3e039..02a1ad94 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv index 6316b308..d00ec3e6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv index b9ba7f5e..0927c0e6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv index 2eaf8a4a..ce7e942a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv index 8b6624a7..9e69225b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv index 2ce0f18b..e69faf0a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv index 30e213a6..400aa027 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv index 70b57db5..d6f2e819 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv index c3afe841..31b6d443 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv index 86774e6b..4c463850 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv index 764623d3..e87e83a3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv index 5491acf3..1c6f3b5a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv index 3e1d5ee4..c17d4c33 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv index 3e1d5ee4..c17d4c33 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv index 9a1f728d..99bd38d1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv index 9a1f728d..99bd38d1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv index 6eee4bb5..f3d158d3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv index 6eee4bb5..f3d158d3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv index 0733ed77..82025036 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv index 761b5910..fffb6b46 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv index a62d4147..74ad3c0b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv index 0573f960..997692ef 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv index 763ec870..c049ffe8 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv index 9c72b251..cd90c543 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv index 4bab8750..77ee93d1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv index 337d310d..0c17e616 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv index 731c5007..785aa5e1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv index 53b5f461..8bf6ee80 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv index 5d3e672a..51e5df18 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv index d9e56f00..899e63e6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv index 66b82d9e..ca72432e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv index ada52de0..1db97731 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv index 0b4a7084..31a4f6b4 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv index 03ac446e..82f209eb 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv index 78bcd210..e4cd5966 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv index 342ba24c..efeb82dd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv index 68a88031..22aadd30 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv index 01af835d..e9a3996a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv @@ -20,8 +20,8 @@ w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, -w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,PosizioneVentilatoreAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FlussoMassimoFiltro,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,UtilizzoDelFiltro,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv index c4dae32c..f16f1a70 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv index 165a7b7a..cfb14055 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv index 8cf5f2e4..9ffffdcc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv index 65d3a798..1bcfd4cc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv index 43b31fe1..6eacd216 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv index b9b60d68..83f1cd58 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv index 267d53f8..dd943d34 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv index 881a2112..06ac57e8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv index 7074f351..0dccad8f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv index 7074f351..0dccad8f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv index 673fe75c..8757c21f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv index 673fe75c..8757c21f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv index 5d564ec4..ffa66749 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv index 5d564ec4..ffa66749 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv index f8cc3781..ee86a009 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv index f8cc3781..ee86a009 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv index 131c6a10..d600df81 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv index 30103c7b..408d995c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv index 54f53899..897de4ea 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv index 73001d7a..b9c2aac4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv index 8b3cc83c..f6495af5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv index 8b3cc83c..f6495af5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv index a5fa429f..d3ca3703 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv index e5eff181..1b147a95 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv index 22a61625..7ed2999e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv index 61888d07..9f1674ee 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv index 7eb7988a..8b502c2a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv index 7eb7988a..8b502c2a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv index 8904dd41..f7fc898f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv index 38986970..ad2953cf 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv index 425a752a..bd238b68 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv index e3be0025..cebd0bf7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv index e536540c..0a84be81 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv index 85127775..24a13514 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv index a66afeb7..da4ff36f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv index 75682a9e..eb560585 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv index cc200910..48735b3a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv index 20a82c3b..f06d56e2 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv index 0126f302..2c3a1d8b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv index f304040d..9254672a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv index 80d3352a..1db594c9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv index e4b11f7b..7fbfb540 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv index 134b1e6a..a0ea61de 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv index 76e5a3ba..3faa0b6f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv index 93f303ac..9f355d97 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv index 5ffbd3b0..37eb91af 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv index d4528c00..b9ca69fa 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv index 700b5855..0684bc0d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv index 1786bd4a..6891e9b3 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv index 6ca13067..7b1f46aa 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv index 9d0db77b..3c9a9ecb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv index 64837206..a68e2f92 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv index 81202f02..23c3888f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv index ffadc23a..6bdb66d7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv index fe3af9bb..6046f6dd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv index 965eb015..d8f12275 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv index 0b5b580b..5502d818 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv index 9207b81c..130c5763 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv index 24c96529..6695be87 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv index cacf1158..53a35879 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv index 32a2dc03..dc6c4b58 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv index 7c2dba5a..e0480578 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv index 875f2b60..f89678a7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv index cd45ea88..81352f1a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv index f003045d..f84945cb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv index 759f7c70..99033db0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv index ebdc00d7..80d9e061 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv index b679319f..8cb4d8dc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv index f606d0e6..4cc312b3 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv index 488f1552..1f6a262c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv index d8c9a4b5..42317355 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv index dd0012a2..b5650d3e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv index 5248a3fa..c337e1cf 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv index bc9469fa..9d0374ea 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv index 95cab817..13448e30 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv index 320cb1fb..ebfd1806 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv index 4c6eb818..9e07df2d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv index 7195e65f..7987a2d5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv index b199193d..78a05f30 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv index 43de7101..5f6cd35f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv index 82232ccb..c5387c4e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv index 760b6e1f..0f3d74b0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv index d38f433c..42620b6f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv index 02e1622c..85568a64 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv index 69f5d0e0..56d2a67b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv index 3f6221be..f175e95a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv index 9a327b20..e9ebe0f5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv index 301a4902..57753d03 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv index 429ae0ec..7ef49289 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv index 429ae0ec..7ef49289 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv index 5335412b..d38efb45 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv index 822480a8..3d739786 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv index 142d7fcc..493ce81b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv index 142d7fcc..493ce81b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv index 5dad0ab4..8101b620 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv index 1fb9c11d..277a3743 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv index e5e880a5..da00d348 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv index f2ce2ad3..baa71a82 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv index fe67e215..d654a49b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv index d1df8023..c72c5155 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv index eb08c58a..fcbea80c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv index e2b813a0..9a9b6615 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv index 0f6cd57c..8a341f94 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv index 2be9aae0..f1d7b9f5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv index 79b00e33..cd803b62 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv index 04d88862..0768a110 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv index 7aff93fa..84c12ca6 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv index 49c8117f..6bad08bb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv index 332b4437..fbaf0505 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv index 048851d0..d56c05ae 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv index 1d6290a4..790b6db7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv index bf8f5b44..c86949f0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv index 0d28c1e1..e7963277 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv index c495b5ca..1daeea70 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv index a2a26166..6448f72e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv index 47385aa5..1e71c9b1 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv index d60d5f4d..c42de74e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv index 100d9615..89c667da 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv index c0e6ff2a..1dc2c0f5 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv index 23a68fd3..d1646133 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv index e78626b6..545deeaa 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv index 099e31a9..fa6fbd6c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv index fb31a80c..7cdf4229 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv index bfb88344..830e8c75 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv index 80ed9e11..9fee1de8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv index e2306ac9..e2f049ac 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv index 9df8e7c2..6bded80f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv index e0c487b2..6562c65d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv index dd62abc4..3febb160 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv index 325bd925..ac1801a4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv index ef20fee1..2206c343 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv index a68d5890..ec0a290e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv index 50e02a1f..0fb61a74 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv index 535e62a0..e7dec700 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv index 631f6ffb..c9d8f881 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv index 6653fe0d..07c3c877 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv index a4862a72..9fc09ea2 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv index a4862a72..9fc09ea2 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv index 03819c65..7e4e5c73 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv index 03819c65..7e4e5c73 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv index c225024d..ba12ef8a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv index c225024d..ba12ef8a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv index c8847fdd..10e288ac 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv index 78e1edf8..35cbfa6b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv index d2544cc7..6e1a57d7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv index 376364fb..e7dc2a63 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv index db42d9cf..b64d3416 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv index 98c1b77f..37eedaf9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv index e5c8b2f6..4e0a12fa 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv index 6cc2954b..c455f428 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv index 763e2d79..7b9300da 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv index 267e4a99..c8c50b28 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv index 2a963321..f3c1b07b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv index 60f387c6..62285bf4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv index ccb8d3bd..175f8370 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv index cc8d607a..d82f0614 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv index aa2403bc..3816beea 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv index d655f218..78a6d775 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv index 9e17f02b..ae4d42d4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv index 76176c2f..920cf1cb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv index ccf30aeb..18e5e58d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv index a2ec63a4..6c86176f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv @@ -22,8 +22,8 @@ w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, -w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,VentilatorModeAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,FilterMaximumDebiet,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,Filtergebruik,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv index 909cab20..dcca2fec 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv index 1b513fbb..d203c269 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv index 08256b28..3036e56c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv index 77043077..75ec71bf 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv index c40dbf36..c29aa58f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv index 553b5cda..0cf7d049 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv index 560d3115..e15e0077 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv index 7aa99a51..7034f85f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv index f2353e9b..4f4971cc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv index f2353e9b..4f4971cc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv index 30446deb..2adfedcc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv index 30446deb..2adfedcc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv index dd94a7e5..ac5fda45 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv index dd94a7e5..ac5fda45 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv index d1a05711..340b8542 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv index d1a05711..340b8542 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv index a4ac4b81..7ac0ad47 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv index 869ed9fd..066b2603 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv index bf14de94..cacb5760 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv index 21492dae..648dd7a2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv index 2db61105..392acfd5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv index 2db61105..392acfd5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv index a3d04956..32cc620f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv index 030a7a7b..b48288f0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv index abb0a02c..8f68279b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv index d218018e..e3776b97 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,min,,UIR,-5,Hours,,max,,UIR,-5,Hours,,step,,UIR,-5,Hours,,default,,UIR,-5,Hours, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv index d91088d3..142bc9ed 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv index d91088d3..142bc9ed 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv index 7b8506b3..2937d633 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv index 918b7038..85bcc12c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv index 242a41cf..c5dc1d7a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv index 4d022852..91d16b4a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv index 3d4ed370..07266221 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv index 8a3b8e5f..e5e3d792 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv index 8dd7ebc1..a6c9ae96 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv index 24fc2376..b18898f5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv index a3eb417e..ede4d0b6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv index 6da5a885..66170d4b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv index 82d9d1cf..80ca14f9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv index 2e62ca32..2b5361ea 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv index 6cd8c205..f2d17efd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv index 645423d8..3930b48e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv index 337789eb..70dfe4f7 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv index 84fec11c..6fb778f4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv index be8aa2e2..d2cad078 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv index 14679d4b..57a4c7dc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv index 798da9d9..980295a3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv index ba9eeb07..a736229a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv index 2b5a0c35..89dcf144 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv index 93fea21c..f47829bc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv index fa3dfeb9..d1f60091 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv index c46545b3..d817162a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv index e91ce4f6..1a9dd97b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv index c8fc7a9c..38fff497 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv index 6e91da92..ba9da9fd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv index c60e4e96..305ec290 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv index 837fd6bb..53a61598 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv index 9c5f8f39..6ae52d69 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv index 10d74546..296a1417 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv index 51f7cb63..14be8a6f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv index c9132a2e..5fddbe32 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv index 95033e56..11cabb6f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv index 31ccf1eb..252ca09d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv index 7c34f12a..391eca23 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv index b6c27653..a19ead4e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv index f68a1c28..86c0ebfd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv index b60ff6d6..35c3422c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv index 8ed42b79..175d4109 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv index d062494d..acdd4c91 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv index e4dc8fca..61144597 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv index fa6b3d8e..8f775ebe 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv index 1fea0b20..bb05503f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv index 8a062bc5..55eb629d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv index 4d1696f3..f8b57470 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv index 7f57e491..7f2edccd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv index 8c880e7f..138c8fb8 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv index acb07540..512f2798 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv index c6964913..010a9467 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv index 5ae343c7..04ab1977 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv index 0b4a8140..a8b8fe7a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv index 4e10bc4e..44344b8a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv index 5d035ce1..f4007095 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv index 6360e8e0..64c23fc1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv index cbe7ed51..8cae7eb1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv index 0a281862..a90dde85 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv index b4bbf71a..8fa97cf2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv index bf3a7300..d2c723a2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv index 80e679e3..88706e76 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv index 86b6838c..f9cfbf02 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv index 86b6838c..f9cfbf02 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv index ab5175e5..7e536bd6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv index 28c120ab..28d985b2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv index b2aa51d2..7b777753 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv index b2aa51d2..7b777753 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv index c162d000..9eeed16f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv index 89aa294d..55f01222 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv index 8150d71e..b0d1c510 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv index dc4fa623..abb607e9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv index 4eaf2022..1b563439 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv index 55e0d824..4661dd15 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv index b33fea3e..e1c6a8a9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv index 287da339..fb5937e1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv index 49888129..dc12013b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv index 34e7eb82..2527ca70 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv index cae2a6b5..536e4a73 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv index cbded1c5..19589c32 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv index 156d12c1..19e1ee4a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv index d7699000..3a1f86a6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv index 6e250797..b28a668b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv index 25e3d191..2a811d26 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv index 38a3db72..b1ea41b3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv index c8e9d2f3..ea6f8811 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv index e5fe473b..5c02e37a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv index 9118dc20..a32b8ce6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv index 8ff83c5d..3f8f1c20 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv index f6d63e72..6b396af3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv index 9ea7a59b..1e97c956 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv index 9da84f6d..3e3b1b11 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv index 3a53d1a6..38cb0421 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv index a0f35a8d..4b572fe0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv index d7326e98..95ed7609 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv index cc5677cb..5099de4e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv index 2cf7ac59..b2ad85d1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv index ccd74c95..9e5e179d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv index a0f46b95..08b5f8e6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv index 4b29534a..28f1aaf3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv index 01fd9618..59869412 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv index b3f65417..96c63298 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv index 66c19969..ef6f82c4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv index 074edd8b..e82d358d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv index af8196c7..a9cc554e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv index c0528ad0..6d651174 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv index 76f24880..8c00a118 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv index 28f285b1..aca53d7f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv index 5aa0805b..ff6fc4d4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv index 08d55eb7..c2f4f3cb 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv index 55c75b4d..2d87df11 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv index 55c75b4d..2d87df11 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv index 2291ff71..5eadab47 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv index 2291ff71..5eadab47 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv index 6be99f3a..0795cab6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv index 6be99f3a..0795cab6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv index 235ca71a..b05cd905 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv index 93dc592a..2107e9e9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv index 4d665f2a..a74ca82c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv index b3b07f04..2a4d6e0d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv index ec0d7960..9235ec78 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv index 8d249fe9..adb28596 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv index 90727e7d..4e9901d3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv index 25ff3c57..99edf568 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv index 5a8a3c14..d5989c84 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv index 7e7db46b..ce66e476 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv index 2004015f..64568e39 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv index 2ee75042..336940d0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv index 4a329d98..56d4939f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv index a3e3a52d..e808f1af 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv index 951ef519..4efd2786 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv index 5b0bec3c..94294ddc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv index 65711091..028e97ec 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv index 9c6bdecb..4ffef303 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv index 6dabdb7e..498efee2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv index 7ee6e004..accf667c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv @@ -22,8 +22,8 @@ w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0100=Errors;0x0001=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified. r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, -w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,,Temporary settings which resets after few minutes +w,,TrybWentylatoraAlternative,FanModeAlternative,,,40cb,0101,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel r,,PrzepływMaksymalnyFiltra,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,min,,UIR,,Days,,max,,UIR,,Days,,step,,UIR,,Days,,default,,UIR,,Days, r,,ZużycieFiltra,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³, diff --git a/src/ebus_message.py b/src/ebus_message.py index 01556c46..31f43554 100644 --- a/src/ebus_message.py +++ b/src/ebus_message.py @@ -125,10 +125,10 @@ def __init__(self, name: str, parameter_name: str, id: int, type: str, is_signed EbusMessage('RequestErrorList', 'errorHistoryViewTableTitle', 0x4090, 0x00, 'r', [Field('', 'HEX:18', 18, 1.0, '', '')]), # This one is only temporary and resets after one or two minutes - EbusMessage('FanMode', 'parameterDescriptionFanMode', 0x40a1, None, 'w', [Field('', 'ULR', 4, 1.0, '0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High', '')]), + EbusMessage('FanMode', 'parameterDescriptionFanMode', 0x40a1, None, 'w', [Field('', 'ULR', 4, 1.0, '0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High', '', 'Temporary settings which resets after few minutes')]), # This one does not reset after one minute, at least in my Sky300 with latest SW; this is the message sent by Brink AirControl wall panel - EbusMessage('FanModeAlternative', 'parameterDescriptionFanMode', 0x40cb, 0x0101, 'w', [Field('', 'UIR', 1, 1.0, '0=Holiday;1=Reduced;2=Normal;3=High', '')], 'Alternative'), + EbusMessage('FanModeAlternative', 'parameterDescriptionFanMode', 0x40cb, 0x0101, 'w', [Field('', 'UIR', 1, 1.0, '0=Holiday;1=Reduced;2=Normal;3=High', '', 'Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel')], 'Alternative'), # The following message simply does not work. The last IGN bytes clearly can be zeroes only sometimes, in general they need to be filed with some value that I was not able to decode the meaning. # EbusMessage('FanMode', 'parameterDescriptionFanMode',0x40a3, 0x01, 'w', [Field('', 'UCH', 1, 1.0, '0=Holiday;1=Reduced;2=Normal;3=High', ''), Field('', 'IGN:2', 2, 1.0, '', '')]),