From 9115dd70982293f6a1c0020700189bacf928d753 Mon Sep 17 00:00:00 2001 From: Petr <5851137+pvyleta@users.noreply.github.com> Date: Wed, 27 Mar 2024 01:19:17 +0100 Subject: [PATCH] added translation even for tha common fields --- .../3c.Excellent300.csv | 160 ------------- .../3c.Sky300.csv | 160 ------------- .../7c.Excellent400.csv | 160 ------------- .../de/3c.Excellent300.csv | 18 +- .../de/3c.Sky300.csv | 18 +- .../de/7c.Excellent400.csv | 18 +- .../en/3c.Excellent300.csv | 18 +- .../en/3c.Sky300.csv | 18 +- .../en/7c.Excellent400.csv | 18 +- .../es/3c.Excellent300.csv | 18 +- .../es/3c.Sky300.csv | 18 +- .../es/7c.Excellent400.csv | 18 +- .../fr/3c.Excellent300.csv | 18 +- .../fr/3c.Sky300.csv | 18 +- .../fr/7c.Excellent400.csv | 18 +- .../it/3c.Excellent300.csv | 18 +- .../it/3c.Sky300.csv | 18 +- .../it/7c.Excellent400.csv | 18 +- .../nl/3c.Excellent300.csv | 18 +- .../nl/3c.Sky300.csv | 18 +- .../nl/7c.Excellent400.csv | 18 +- .../pl/3c.Excellent300.csv | 18 +- .../pl/3c.Sky300.csv | 18 +- .../pl/7c.Excellent400.csv | 18 +- .../CWLF250.10806.10808.csv | 84 ------- .../CWLF250.10806.10808.plus.csv | 110 --------- .../CWLF250.10809.99999.csv | 125 ---------- .../CWLF250.10809.99999.plus.csv | 151 ------------ .../CWLF350.10806.10808.csv | 84 ------- .../CWLF350.10806.10808.plus.csv | 110 --------- .../CWLF350.10809.99999.csv | 125 ---------- .../CWLF350.10809.99999.plus.csv | 151 ------------ .../CWLTower300.10603.10603.csv | 122 ---------- .../CWLTower300.10603.10603.plus.csv | 122 ---------- .../CWLTower300.10604.10605.csv | 148 ------------ .../CWLTower300.10604.10605.plus.csv | 148 ------------ .../CWLTower300.10606.10607.csv | 150 ------------ .../CWLTower300.10606.10607.plus.csv | 150 ------------ .../CWLTower300.10608.10706.csv | 152 ------------ .../CWLTower300.10608.10706.plus.csv | 152 ------------ .../CWLTower300.10801.10805.csv | 152 ------------ .../CWLTower300.10801.10805.plus.csv | 160 ------------- .../CWLTower300.10806.99999.csv | 152 ------------ .../CWLTower300.10806.99999.plus.csv | 162 ------------- .../ConstantRPM400.10505.99999.csv | 85 ------- .../ConstantRPM400.10505.99999.plus.csv | 85 ------- .../DecentralAir70.10101.10700.csv | 98 -------- .../DecentralAir70.10101.10700.plus.csv | 112 --------- .../DecentralAir70.10701.99999.csv | 98 -------- .../DecentralAir70.10701.99999.plus.csv | 112 --------- .../Elan10.10103.99999.csv | 86 ------- .../Elan10.10103.99999.plus.csv | 86 ------- .../Elan4.10104.99999.csv | 112 --------- .../Elan4.10104.99999.plus.csv | 122 ---------- .../Excellent180.10503.10603.csv | 92 -------- .../Excellent180.10503.10603.plus.csv | 126 ---------- .../Excellent180.10604.10605.csv | 100 -------- .../Excellent180.10604.10605.plus.csv | 152 ------------ .../Excellent180.10606.10607.csv | 102 -------- .../Excellent180.10606.10607.plus.csv | 154 ------------ .../Excellent180.10608.10706.csv | 104 -------- .../Excellent180.10608.10706.plus.csv | 156 ------------ .../Excellent180.10801.10805.csv | 104 -------- .../Excellent180.10801.10805.plus.csv | 164 ------------- .../Excellent180.10806.99999.csv | 124 ---------- .../Excellent180.10806.99999.plus.csv | 166 ------------- .../Excellent300.10502.10603.csv | 91 ------- .../Excellent300.10502.10603.plus.csv | 125 ---------- .../Excellent300.10604.10605.csv | 99 -------- .../Excellent300.10604.10605.plus.csv | 151 ------------ .../Excellent300.10606.10607.csv | 101 -------- .../Excellent300.10606.10607.plus.csv | 153 ------------ .../Excellent300.10608.10706.csv | 103 -------- .../Excellent300.10608.10706.plus.csv | 155 ------------ .../Excellent300.10801.10805.csv | 103 -------- .../Excellent300.10801.10805.plus.csv | 163 ------------- .../Excellent300.10806.99999.csv | 125 ---------- .../Excellent300.10806.99999.plus.csv | 165 ------------- .../Excellent400.10401.10403.csv | 85 ------- .../Excellent400.10401.10403.plus.csv | 119 ---------- .../Excellent400.10502.10603.csv | 91 ------- .../Excellent400.10502.10603.plus.csv | 125 ---------- .../Excellent400.10604.10605.csv | 99 -------- .../Excellent400.10604.10605.plus.csv | 151 ------------ .../Excellent400.10606.10607.csv | 101 -------- .../Excellent400.10606.10607.plus.csv | 153 ------------ .../Excellent400.10608.10706.csv | 103 -------- .../Excellent400.10608.10706.plus.csv | 155 ------------ .../Excellent400.10801.10805.csv | 103 -------- .../Excellent400.10801.10805.plus.csv | 163 ------------- .../Excellent400.10806.99999.csv | 125 ---------- .../Excellent400.10806.99999.plus.csv | 165 ------------- .../Excellent450.10604.10605.csv | 99 -------- .../Excellent450.10604.10605.plus.csv | 151 ------------ .../Excellent450.10606.10607.csv | 101 -------- .../Excellent450.10606.10607.plus.csv | 153 ------------ .../Excellent450.10608.10706.csv | 103 -------- .../Excellent450.10608.10706.plus.csv | 155 ------------ .../Excellent450.10801.10805.csv | 103 -------- .../Excellent450.10801.10805.plus.csv | 163 ------------- .../Excellent450.10806.99999.csv | 125 ---------- .../Excellent450.10806.99999.plus.csv | 165 ------------- .../Flair200.10101.99999.csv | 222 ----------------- .../Flair225.10101.99999.csv | 222 ----------------- .../Flair300.10101.20105.csv | 222 ----------------- .../Flair300.20106.99999.csv | 222 ----------------- .../Flair325.10101.20105.csv | 222 ----------------- .../Flair325.20106.99999.csv | 222 ----------------- .../Flair400.10101.20105.csv | 222 ----------------- .../Flair400.20106.99999.csv | 222 ----------------- .../Flair450.10101.99999.csv | 223 ------------------ .../Flair600.10101.99999.csv | 223 ------------------ .../MultiRoomCtrlT01.0.10101.csv | 50 ---- .../MultiRoomCtrlT01.10102.10102.csv | 58 ----- .../MultiRoomCtrlT01.10103.99999.csv | 80 ------- .../Nather300.10703.10706.csv | 90 ------- .../Nather300.10703.10706.plus.csv | 90 ------- .../Nather300.10801.10805.csv | 90 ------- .../Nather300.10801.10805.plus.csv | 98 -------- .../Nather300.10806.99999.csv | 100 -------- .../Nather300.10806.99999.plus.csv | 100 -------- .../RenoventElan300.10604.10605.csv | 100 -------- .../RenoventElan300.10604.10605.plus.csv | 152 ------------ .../RenoventElan300.10606.10607.csv | 102 -------- .../RenoventElan300.10606.10607.plus.csv | 154 ------------ .../RenoventElan300.10608.10706.csv | 104 -------- .../RenoventElan300.10608.10706.plus.csv | 156 ------------ .../RenoventElan300.10801.10805.csv | 104 -------- .../RenoventElan300.10801.10805.plus.csv | 164 ------------- .../RenoventElan300.10806.99999.csv | 106 --------- .../RenoventElan300.10806.99999.plus.csv | 166 ------------- .../Sky150.10504.10603.csv | 89 ------- .../Sky150.10504.10603.plus.csv | 123 ---------- .../Sky150.10604.10605.csv | 97 -------- .../Sky150.10604.10605.plus.csv | 149 ------------ .../Sky150.10606.10607.csv | 99 -------- .../Sky150.10606.10607.plus.csv | 151 ------------ .../Sky150.10608.10706.csv | 101 -------- .../Sky150.10608.10706.plus.csv | 153 ------------ .../Sky150.10801.10805.csv | 101 -------- .../Sky150.10801.10805.plus.csv | 161 ------------- .../Sky150.10806.99999.csv | 125 ---------- .../Sky150.10806.99999.plus.csv | 163 ------------- .../Sky200.10702.10706.csv | 101 -------- .../Sky200.10702.10706.plus.csv | 153 ------------ .../Sky200.10801.10805.csv | 101 -------- .../Sky200.10801.10805.plus.csv | 161 ------------- .../Sky200.10806.99999.csv | 125 ---------- .../Sky200.10806.99999.plus.csv | 163 ------------- .../Sky300.10401.10403.csv | 85 ------- .../Sky300.10401.10403.plus.csv | 119 ---------- .../Sky300.10502.10603.csv | 91 ------- .../Sky300.10502.10603.plus.csv | 125 ---------- .../Sky300.10604.10605.csv | 99 -------- .../Sky300.10604.10605.plus.csv | 151 ------------ .../Sky300.10606.10607.csv | 101 -------- .../Sky300.10606.10607.plus.csv | 153 ------------ .../Sky300.10608.10706.csv | 103 -------- .../Sky300.10608.10706.plus.csv | 155 ------------ .../Sky300.10801.10805.csv | 103 -------- .../Sky300.10801.10805.plus.csv | 163 ------------- .../Sky300.10806.99999.csv | 125 ---------- .../Sky300.10806.99999.plus.csv | 165 ------------- .../ValveT01.0.99999.csv | 83 ------- .../Vitovent200W.10104.10104.csv | 94 -------- .../Vitovent200W.10104.10104.plus.csv | 94 -------- .../Vitovent200W.10105.10105.csv | 99 -------- .../Vitovent200W.10105.10105.plus.csv | 99 -------- .../Vitovent200W.10106.99999.csv | 99 -------- .../Vitovent200W.10106.99999.plus.csv | 99 -------- .../Vitovent300C.10101.10105.csv | 101 -------- .../Vitovent300C.10101.10105.plus.csv | 153 ------------ .../Vitovent300C.10106.99999.csv | 101 -------- .../Vitovent300C.10106.99999.plus.csv | 153 ------------ .../Vitovent300W300.10101.10105.csv | 103 -------- .../Vitovent300W300.10101.10105.plus.csv | 155 ------------ .../Vitovent300W300.10106.99999.csv | 103 -------- .../Vitovent300W300.10106.99999.plus.csv | 155 ------------ .../Vitovent300W400.10101.10105.csv | 103 -------- .../Vitovent300W400.10101.10105.plus.csv | 155 ------------ .../Vitovent300W400.10106.99999.csv | 103 -------- .../Vitovent300W400.10106.99999.plus.csv | 155 ------------ .../Vitovent300WH32SA225.10101.10109.csv | 106 --------- .../Vitovent300WH32SA225.10110.10110.csv | 174 -------------- .../Vitovent300WH32SA225.10111.99999.csv | 180 -------------- .../Vitovent300WH32SA600.10101.99999.csv | 183 -------------- .../Vitovent300WH32SC325.10101.10110.csv | 174 -------------- .../Vitovent300WH32SC325.10111.99999.csv | 180 -------------- .../Vitovent300WH32SC400.10101.10110.csv | 174 -------------- .../Vitovent300WH32SC400.10111.99999.csv | 180 -------------- .../de/CWLF250.10806.10808.csv | 18 +- .../de/CWLF250.10806.10808.plus.csv | 18 +- .../de/CWLF250.10809.99999.csv | 18 +- .../de/CWLF250.10809.99999.plus.csv | 18 +- .../de/CWLF350.10806.10808.csv | 18 +- .../de/CWLF350.10806.10808.plus.csv | 18 +- .../de/CWLF350.10809.99999.csv | 18 +- .../de/CWLF350.10809.99999.plus.csv | 18 +- .../de/CWLTower300.10603.10603.csv | 18 +- .../de/CWLTower300.10603.10603.plus.csv | 18 +- .../de/CWLTower300.10604.10605.csv | 18 +- .../de/CWLTower300.10604.10605.plus.csv | 18 +- .../de/CWLTower300.10606.10607.csv | 18 +- .../de/CWLTower300.10606.10607.plus.csv | 18 +- .../de/CWLTower300.10608.10706.csv | 18 +- .../de/CWLTower300.10608.10706.plus.csv | 18 +- .../de/CWLTower300.10801.10805.csv | 18 +- .../de/CWLTower300.10801.10805.plus.csv | 18 +- .../de/CWLTower300.10806.99999.csv | 18 +- .../de/CWLTower300.10806.99999.plus.csv | 18 +- .../de/ConstantRPM400.10505.99999.csv | 18 +- .../de/ConstantRPM400.10505.99999.plus.csv | 18 +- .../de/DecentralAir70.10101.10700.csv | 16 +- .../de/DecentralAir70.10101.10700.plus.csv | 16 +- .../de/DecentralAir70.10701.99999.csv | 16 +- .../de/DecentralAir70.10701.99999.plus.csv | 16 +- .../de/Elan10.10103.99999.csv | 18 +- .../de/Elan10.10103.99999.plus.csv | 18 +- .../de/Elan4.10104.99999.csv | 18 +- .../de/Elan4.10104.99999.plus.csv | 18 +- .../de/Excellent180.10503.10603.csv | 18 +- .../de/Excellent180.10503.10603.plus.csv | 18 +- .../de/Excellent180.10604.10605.csv | 18 +- .../de/Excellent180.10604.10605.plus.csv | 18 +- .../de/Excellent180.10606.10607.csv | 18 +- .../de/Excellent180.10606.10607.plus.csv | 18 +- .../de/Excellent180.10608.10706.csv | 18 +- .../de/Excellent180.10608.10706.plus.csv | 18 +- .../de/Excellent180.10801.10805.csv | 18 +- .../de/Excellent180.10801.10805.plus.csv | 18 +- .../de/Excellent180.10806.99999.csv | 18 +- .../de/Excellent180.10806.99999.plus.csv | 18 +- .../de/Excellent300.10502.10603.csv | 18 +- .../de/Excellent300.10502.10603.plus.csv | 18 +- .../de/Excellent300.10604.10605.csv | 18 +- .../de/Excellent300.10604.10605.plus.csv | 18 +- .../de/Excellent300.10606.10607.csv | 18 +- .../de/Excellent300.10606.10607.plus.csv | 18 +- .../de/Excellent300.10608.10706.csv | 18 +- .../de/Excellent300.10608.10706.plus.csv | 18 +- .../de/Excellent300.10801.10805.csv | 18 +- .../de/Excellent300.10801.10805.plus.csv | 18 +- .../de/Excellent300.10806.99999.csv | 18 +- .../de/Excellent300.10806.99999.plus.csv | 18 +- .../de/Excellent400.10401.10403.csv | 18 +- .../de/Excellent400.10401.10403.plus.csv | 18 +- .../de/Excellent400.10502.10603.csv | 18 +- .../de/Excellent400.10502.10603.plus.csv | 18 +- .../de/Excellent400.10604.10605.csv | 18 +- .../de/Excellent400.10604.10605.plus.csv | 18 +- .../de/Excellent400.10606.10607.csv | 18 +- .../de/Excellent400.10606.10607.plus.csv | 18 +- .../de/Excellent400.10608.10706.csv | 18 +- .../de/Excellent400.10608.10706.plus.csv | 18 +- .../de/Excellent400.10801.10805.csv | 18 +- .../de/Excellent400.10801.10805.plus.csv | 18 +- .../de/Excellent400.10806.99999.csv | 18 +- .../de/Excellent400.10806.99999.plus.csv | 18 +- .../de/Excellent450.10604.10605.csv | 18 +- .../de/Excellent450.10604.10605.plus.csv | 18 +- .../de/Excellent450.10606.10607.csv | 18 +- .../de/Excellent450.10606.10607.plus.csv | 18 +- .../de/Excellent450.10608.10706.csv | 18 +- .../de/Excellent450.10608.10706.plus.csv | 18 +- .../de/Excellent450.10801.10805.csv | 18 +- .../de/Excellent450.10801.10805.plus.csv | 18 +- .../de/Excellent450.10806.99999.csv | 18 +- .../de/Excellent450.10806.99999.plus.csv | 18 +- .../de/Flair200.10101.99999.csv | 18 +- .../de/Flair225.10101.99999.csv | 18 +- .../de/Flair300.10101.20105.csv | 18 +- .../de/Flair300.20106.99999.csv | 18 +- .../de/Flair325.10101.20105.csv | 18 +- .../de/Flair325.20106.99999.csv | 18 +- .../de/Flair400.10101.20105.csv | 18 +- .../de/Flair400.20106.99999.csv | 18 +- .../de/Flair450.10101.99999.csv | 18 +- .../de/Flair600.10101.99999.csv | 18 +- .../de/MultiRoomCtrlT01.0.10101.csv | 6 +- .../de/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../de/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../de/Nather300.10703.10706.csv | 18 +- .../de/Nather300.10703.10706.plus.csv | 18 +- .../de/Nather300.10801.10805.csv | 18 +- .../de/Nather300.10801.10805.plus.csv | 18 +- .../de/Nather300.10806.99999.csv | 18 +- .../de/Nather300.10806.99999.plus.csv | 18 +- .../de/RenoventElan300.10604.10605.csv | 18 +- .../de/RenoventElan300.10604.10605.plus.csv | 18 +- .../de/RenoventElan300.10606.10607.csv | 18 +- .../de/RenoventElan300.10606.10607.plus.csv | 18 +- .../de/RenoventElan300.10608.10706.csv | 18 +- .../de/RenoventElan300.10608.10706.plus.csv | 18 +- .../de/RenoventElan300.10801.10805.csv | 18 +- .../de/RenoventElan300.10801.10805.plus.csv | 18 +- .../de/RenoventElan300.10806.99999.csv | 18 +- .../de/RenoventElan300.10806.99999.plus.csv | 18 +- .../de/Sky150.10504.10603.csv | 18 +- .../de/Sky150.10504.10603.plus.csv | 18 +- .../de/Sky150.10604.10605.csv | 18 +- .../de/Sky150.10604.10605.plus.csv | 18 +- .../de/Sky150.10606.10607.csv | 18 +- .../de/Sky150.10606.10607.plus.csv | 18 +- .../de/Sky150.10608.10706.csv | 18 +- .../de/Sky150.10608.10706.plus.csv | 18 +- .../de/Sky150.10801.10805.csv | 18 +- .../de/Sky150.10801.10805.plus.csv | 18 +- .../de/Sky150.10806.99999.csv | 18 +- .../de/Sky150.10806.99999.plus.csv | 18 +- .../de/Sky200.10702.10706.csv | 18 +- .../de/Sky200.10702.10706.plus.csv | 18 +- .../de/Sky200.10801.10805.csv | 18 +- .../de/Sky200.10801.10805.plus.csv | 18 +- .../de/Sky200.10806.99999.csv | 18 +- .../de/Sky200.10806.99999.plus.csv | 18 +- .../de/Sky300.10401.10403.csv | 18 +- .../de/Sky300.10401.10403.plus.csv | 18 +- .../de/Sky300.10502.10603.csv | 18 +- .../de/Sky300.10502.10603.plus.csv | 18 +- .../de/Sky300.10604.10605.csv | 18 +- .../de/Sky300.10604.10605.plus.csv | 18 +- .../de/Sky300.10606.10607.csv | 18 +- .../de/Sky300.10606.10607.plus.csv | 18 +- .../de/Sky300.10608.10706.csv | 18 +- .../de/Sky300.10608.10706.plus.csv | 18 +- .../de/Sky300.10801.10805.csv | 18 +- .../de/Sky300.10801.10805.plus.csv | 18 +- .../de/Sky300.10806.99999.csv | 18 +- .../de/Sky300.10806.99999.plus.csv | 18 +- .../de/ValveT01.0.99999.csv | 6 +- .../de/Vitovent200W.10104.10104.csv | 18 +- .../de/Vitovent200W.10104.10104.plus.csv | 18 +- .../de/Vitovent200W.10105.10105.csv | 18 +- .../de/Vitovent200W.10105.10105.plus.csv | 18 +- .../de/Vitovent200W.10106.99999.csv | 18 +- .../de/Vitovent200W.10106.99999.plus.csv | 18 +- .../de/Vitovent300C.10101.10105.csv | 18 +- .../de/Vitovent300C.10101.10105.plus.csv | 18 +- .../de/Vitovent300C.10106.99999.csv | 18 +- .../de/Vitovent300C.10106.99999.plus.csv | 18 +- .../de/Vitovent300W300.10101.10105.csv | 18 +- .../de/Vitovent300W300.10101.10105.plus.csv | 18 +- .../de/Vitovent300W300.10106.99999.csv | 18 +- .../de/Vitovent300W300.10106.99999.plus.csv | 18 +- .../de/Vitovent300W400.10101.10105.csv | 18 +- .../de/Vitovent300W400.10101.10105.plus.csv | 18 +- .../de/Vitovent300W400.10106.99999.csv | 18 +- .../de/Vitovent300W400.10106.99999.plus.csv | 18 +- .../de/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../de/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../de/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../de/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../de/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../de/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../de/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../de/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../en/CWLF250.10806.10808.csv | 18 +- .../en/CWLF250.10806.10808.plus.csv | 18 +- .../en/CWLF250.10809.99999.csv | 18 +- .../en/CWLF250.10809.99999.plus.csv | 18 +- .../en/CWLF350.10806.10808.csv | 18 +- .../en/CWLF350.10806.10808.plus.csv | 18 +- .../en/CWLF350.10809.99999.csv | 18 +- .../en/CWLF350.10809.99999.plus.csv | 18 +- .../en/CWLTower300.10603.10603.csv | 18 +- .../en/CWLTower300.10603.10603.plus.csv | 18 +- .../en/CWLTower300.10604.10605.csv | 18 +- .../en/CWLTower300.10604.10605.plus.csv | 18 +- .../en/CWLTower300.10606.10607.csv | 18 +- .../en/CWLTower300.10606.10607.plus.csv | 18 +- .../en/CWLTower300.10608.10706.csv | 18 +- .../en/CWLTower300.10608.10706.plus.csv | 18 +- .../en/CWLTower300.10801.10805.csv | 18 +- .../en/CWLTower300.10801.10805.plus.csv | 18 +- .../en/CWLTower300.10806.99999.csv | 18 +- .../en/CWLTower300.10806.99999.plus.csv | 18 +- .../en/ConstantRPM400.10505.99999.csv | 18 +- .../en/ConstantRPM400.10505.99999.plus.csv | 18 +- .../en/DecentralAir70.10101.10700.csv | 16 +- .../en/DecentralAir70.10101.10700.plus.csv | 16 +- .../en/DecentralAir70.10701.99999.csv | 16 +- .../en/DecentralAir70.10701.99999.plus.csv | 16 +- .../en/Elan10.10103.99999.csv | 18 +- .../en/Elan10.10103.99999.plus.csv | 18 +- .../en/Elan4.10104.99999.csv | 18 +- .../en/Elan4.10104.99999.plus.csv | 18 +- .../en/Excellent180.10503.10603.csv | 18 +- .../en/Excellent180.10503.10603.plus.csv | 18 +- .../en/Excellent180.10604.10605.csv | 18 +- .../en/Excellent180.10604.10605.plus.csv | 18 +- .../en/Excellent180.10606.10607.csv | 18 +- .../en/Excellent180.10606.10607.plus.csv | 18 +- .../en/Excellent180.10608.10706.csv | 18 +- .../en/Excellent180.10608.10706.plus.csv | 18 +- .../en/Excellent180.10801.10805.csv | 18 +- .../en/Excellent180.10801.10805.plus.csv | 18 +- .../en/Excellent180.10806.99999.csv | 18 +- .../en/Excellent180.10806.99999.plus.csv | 18 +- .../en/Excellent300.10502.10603.csv | 18 +- .../en/Excellent300.10502.10603.plus.csv | 18 +- .../en/Excellent300.10604.10605.csv | 18 +- .../en/Excellent300.10604.10605.plus.csv | 18 +- .../en/Excellent300.10606.10607.csv | 18 +- .../en/Excellent300.10606.10607.plus.csv | 18 +- .../en/Excellent300.10608.10706.csv | 18 +- .../en/Excellent300.10608.10706.plus.csv | 18 +- .../en/Excellent300.10801.10805.csv | 18 +- .../en/Excellent300.10801.10805.plus.csv | 18 +- .../en/Excellent300.10806.99999.csv | 18 +- .../en/Excellent300.10806.99999.plus.csv | 18 +- .../en/Excellent400.10401.10403.csv | 18 +- .../en/Excellent400.10401.10403.plus.csv | 18 +- .../en/Excellent400.10502.10603.csv | 18 +- .../en/Excellent400.10502.10603.plus.csv | 18 +- .../en/Excellent400.10604.10605.csv | 18 +- .../en/Excellent400.10604.10605.plus.csv | 18 +- .../en/Excellent400.10606.10607.csv | 18 +- .../en/Excellent400.10606.10607.plus.csv | 18 +- .../en/Excellent400.10608.10706.csv | 18 +- .../en/Excellent400.10608.10706.plus.csv | 18 +- .../en/Excellent400.10801.10805.csv | 18 +- .../en/Excellent400.10801.10805.plus.csv | 18 +- .../en/Excellent400.10806.99999.csv | 18 +- .../en/Excellent400.10806.99999.plus.csv | 18 +- .../en/Excellent450.10604.10605.csv | 18 +- .../en/Excellent450.10604.10605.plus.csv | 18 +- .../en/Excellent450.10606.10607.csv | 18 +- .../en/Excellent450.10606.10607.plus.csv | 18 +- .../en/Excellent450.10608.10706.csv | 18 +- .../en/Excellent450.10608.10706.plus.csv | 18 +- .../en/Excellent450.10801.10805.csv | 18 +- .../en/Excellent450.10801.10805.plus.csv | 18 +- .../en/Excellent450.10806.99999.csv | 18 +- .../en/Excellent450.10806.99999.plus.csv | 18 +- .../en/Flair200.10101.99999.csv | 18 +- .../en/Flair225.10101.99999.csv | 18 +- .../en/Flair300.10101.20105.csv | 18 +- .../en/Flair300.20106.99999.csv | 18 +- .../en/Flair325.10101.20105.csv | 18 +- .../en/Flair325.20106.99999.csv | 18 +- .../en/Flair400.10101.20105.csv | 18 +- .../en/Flair400.20106.99999.csv | 18 +- .../en/Flair450.10101.99999.csv | 18 +- .../en/Flair600.10101.99999.csv | 18 +- .../en/MultiRoomCtrlT01.0.10101.csv | 6 +- .../en/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../en/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../en/Nather300.10703.10706.csv | 18 +- .../en/Nather300.10703.10706.plus.csv | 18 +- .../en/Nather300.10801.10805.csv | 18 +- .../en/Nather300.10801.10805.plus.csv | 18 +- .../en/Nather300.10806.99999.csv | 18 +- .../en/Nather300.10806.99999.plus.csv | 18 +- .../en/RenoventElan300.10604.10605.csv | 18 +- .../en/RenoventElan300.10604.10605.plus.csv | 18 +- .../en/RenoventElan300.10606.10607.csv | 18 +- .../en/RenoventElan300.10606.10607.plus.csv | 18 +- .../en/RenoventElan300.10608.10706.csv | 18 +- .../en/RenoventElan300.10608.10706.plus.csv | 18 +- .../en/RenoventElan300.10801.10805.csv | 18 +- .../en/RenoventElan300.10801.10805.plus.csv | 18 +- .../en/RenoventElan300.10806.99999.csv | 18 +- .../en/RenoventElan300.10806.99999.plus.csv | 18 +- .../en/Sky150.10504.10603.csv | 18 +- .../en/Sky150.10504.10603.plus.csv | 18 +- .../en/Sky150.10604.10605.csv | 18 +- .../en/Sky150.10604.10605.plus.csv | 18 +- .../en/Sky150.10606.10607.csv | 18 +- .../en/Sky150.10606.10607.plus.csv | 18 +- .../en/Sky150.10608.10706.csv | 18 +- .../en/Sky150.10608.10706.plus.csv | 18 +- .../en/Sky150.10801.10805.csv | 18 +- .../en/Sky150.10801.10805.plus.csv | 18 +- .../en/Sky150.10806.99999.csv | 18 +- .../en/Sky150.10806.99999.plus.csv | 18 +- .../en/Sky200.10702.10706.csv | 18 +- .../en/Sky200.10702.10706.plus.csv | 18 +- .../en/Sky200.10801.10805.csv | 18 +- .../en/Sky200.10801.10805.plus.csv | 18 +- .../en/Sky200.10806.99999.csv | 18 +- .../en/Sky200.10806.99999.plus.csv | 18 +- .../en/Sky300.10401.10403.csv | 18 +- .../en/Sky300.10401.10403.plus.csv | 18 +- .../en/Sky300.10502.10603.csv | 18 +- .../en/Sky300.10502.10603.plus.csv | 18 +- .../en/Sky300.10604.10605.csv | 18 +- .../en/Sky300.10604.10605.plus.csv | 18 +- .../en/Sky300.10606.10607.csv | 18 +- .../en/Sky300.10606.10607.plus.csv | 18 +- .../en/Sky300.10608.10706.csv | 18 +- .../en/Sky300.10608.10706.plus.csv | 18 +- .../en/Sky300.10801.10805.csv | 18 +- .../en/Sky300.10801.10805.plus.csv | 18 +- .../en/Sky300.10806.99999.csv | 18 +- .../en/Sky300.10806.99999.plus.csv | 18 +- .../en/ValveT01.0.99999.csv | 6 +- .../en/Vitovent200W.10104.10104.csv | 18 +- .../en/Vitovent200W.10104.10104.plus.csv | 18 +- .../en/Vitovent200W.10105.10105.csv | 18 +- .../en/Vitovent200W.10105.10105.plus.csv | 18 +- .../en/Vitovent200W.10106.99999.csv | 18 +- .../en/Vitovent200W.10106.99999.plus.csv | 18 +- .../en/Vitovent300C.10101.10105.csv | 18 +- .../en/Vitovent300C.10101.10105.plus.csv | 18 +- .../en/Vitovent300C.10106.99999.csv | 18 +- .../en/Vitovent300C.10106.99999.plus.csv | 18 +- .../en/Vitovent300W300.10101.10105.csv | 18 +- .../en/Vitovent300W300.10101.10105.plus.csv | 18 +- .../en/Vitovent300W300.10106.99999.csv | 18 +- .../en/Vitovent300W300.10106.99999.plus.csv | 18 +- .../en/Vitovent300W400.10101.10105.csv | 18 +- .../en/Vitovent300W400.10101.10105.plus.csv | 18 +- .../en/Vitovent300W400.10106.99999.csv | 18 +- .../en/Vitovent300W400.10106.99999.plus.csv | 18 +- .../en/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../en/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../en/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../en/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../en/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../en/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../en/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../en/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../es/CWLF250.10806.10808.csv | 18 +- .../es/CWLF250.10806.10808.plus.csv | 18 +- .../es/CWLF250.10809.99999.csv | 18 +- .../es/CWLF250.10809.99999.plus.csv | 18 +- .../es/CWLF350.10806.10808.csv | 18 +- .../es/CWLF350.10806.10808.plus.csv | 18 +- .../es/CWLF350.10809.99999.csv | 18 +- .../es/CWLF350.10809.99999.plus.csv | 18 +- .../es/CWLTower300.10603.10603.csv | 18 +- .../es/CWLTower300.10603.10603.plus.csv | 18 +- .../es/CWLTower300.10604.10605.csv | 18 +- .../es/CWLTower300.10604.10605.plus.csv | 18 +- .../es/CWLTower300.10606.10607.csv | 18 +- .../es/CWLTower300.10606.10607.plus.csv | 18 +- .../es/CWLTower300.10608.10706.csv | 18 +- .../es/CWLTower300.10608.10706.plus.csv | 18 +- .../es/CWLTower300.10801.10805.csv | 18 +- .../es/CWLTower300.10801.10805.plus.csv | 18 +- .../es/CWLTower300.10806.99999.csv | 18 +- .../es/CWLTower300.10806.99999.plus.csv | 18 +- .../es/ConstantRPM400.10505.99999.csv | 18 +- .../es/ConstantRPM400.10505.99999.plus.csv | 18 +- .../es/DecentralAir70.10101.10700.csv | 16 +- .../es/DecentralAir70.10101.10700.plus.csv | 16 +- .../es/DecentralAir70.10701.99999.csv | 16 +- .../es/DecentralAir70.10701.99999.plus.csv | 16 +- .../es/Elan10.10103.99999.csv | 18 +- .../es/Elan10.10103.99999.plus.csv | 18 +- .../es/Elan4.10104.99999.csv | 18 +- .../es/Elan4.10104.99999.plus.csv | 18 +- .../es/Excellent180.10503.10603.csv | 18 +- .../es/Excellent180.10503.10603.plus.csv | 18 +- .../es/Excellent180.10604.10605.csv | 18 +- .../es/Excellent180.10604.10605.plus.csv | 18 +- .../es/Excellent180.10606.10607.csv | 18 +- .../es/Excellent180.10606.10607.plus.csv | 18 +- .../es/Excellent180.10608.10706.csv | 18 +- .../es/Excellent180.10608.10706.plus.csv | 18 +- .../es/Excellent180.10801.10805.csv | 18 +- .../es/Excellent180.10801.10805.plus.csv | 18 +- .../es/Excellent180.10806.99999.csv | 18 +- .../es/Excellent180.10806.99999.plus.csv | 18 +- .../es/Excellent300.10502.10603.csv | 18 +- .../es/Excellent300.10502.10603.plus.csv | 18 +- .../es/Excellent300.10604.10605.csv | 18 +- .../es/Excellent300.10604.10605.plus.csv | 18 +- .../es/Excellent300.10606.10607.csv | 18 +- .../es/Excellent300.10606.10607.plus.csv | 18 +- .../es/Excellent300.10608.10706.csv | 18 +- .../es/Excellent300.10608.10706.plus.csv | 18 +- .../es/Excellent300.10801.10805.csv | 18 +- .../es/Excellent300.10801.10805.plus.csv | 18 +- .../es/Excellent300.10806.99999.csv | 18 +- .../es/Excellent300.10806.99999.plus.csv | 18 +- .../es/Excellent400.10401.10403.csv | 18 +- .../es/Excellent400.10401.10403.plus.csv | 18 +- .../es/Excellent400.10502.10603.csv | 18 +- .../es/Excellent400.10502.10603.plus.csv | 18 +- .../es/Excellent400.10604.10605.csv | 18 +- .../es/Excellent400.10604.10605.plus.csv | 18 +- .../es/Excellent400.10606.10607.csv | 18 +- .../es/Excellent400.10606.10607.plus.csv | 18 +- .../es/Excellent400.10608.10706.csv | 18 +- .../es/Excellent400.10608.10706.plus.csv | 18 +- .../es/Excellent400.10801.10805.csv | 18 +- .../es/Excellent400.10801.10805.plus.csv | 18 +- .../es/Excellent400.10806.99999.csv | 18 +- .../es/Excellent400.10806.99999.plus.csv | 18 +- .../es/Excellent450.10604.10605.csv | 18 +- .../es/Excellent450.10604.10605.plus.csv | 18 +- .../es/Excellent450.10606.10607.csv | 18 +- .../es/Excellent450.10606.10607.plus.csv | 18 +- .../es/Excellent450.10608.10706.csv | 18 +- .../es/Excellent450.10608.10706.plus.csv | 18 +- .../es/Excellent450.10801.10805.csv | 18 +- .../es/Excellent450.10801.10805.plus.csv | 18 +- .../es/Excellent450.10806.99999.csv | 18 +- .../es/Excellent450.10806.99999.plus.csv | 18 +- .../es/Flair200.10101.99999.csv | 18 +- .../es/Flair225.10101.99999.csv | 18 +- .../es/Flair300.10101.20105.csv | 18 +- .../es/Flair300.20106.99999.csv | 18 +- .../es/Flair325.10101.20105.csv | 18 +- .../es/Flair325.20106.99999.csv | 18 +- .../es/Flair400.10101.20105.csv | 18 +- .../es/Flair400.20106.99999.csv | 18 +- .../es/Flair450.10101.99999.csv | 18 +- .../es/Flair600.10101.99999.csv | 18 +- .../es/MultiRoomCtrlT01.0.10101.csv | 6 +- .../es/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../es/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../es/Nather300.10703.10706.csv | 18 +- .../es/Nather300.10703.10706.plus.csv | 18 +- .../es/Nather300.10801.10805.csv | 18 +- .../es/Nather300.10801.10805.plus.csv | 18 +- .../es/Nather300.10806.99999.csv | 18 +- .../es/Nather300.10806.99999.plus.csv | 18 +- .../es/RenoventElan300.10604.10605.csv | 18 +- .../es/RenoventElan300.10604.10605.plus.csv | 18 +- .../es/RenoventElan300.10606.10607.csv | 18 +- .../es/RenoventElan300.10606.10607.plus.csv | 18 +- .../es/RenoventElan300.10608.10706.csv | 18 +- .../es/RenoventElan300.10608.10706.plus.csv | 18 +- .../es/RenoventElan300.10801.10805.csv | 18 +- .../es/RenoventElan300.10801.10805.plus.csv | 18 +- .../es/RenoventElan300.10806.99999.csv | 18 +- .../es/RenoventElan300.10806.99999.plus.csv | 18 +- .../es/Sky150.10504.10603.csv | 18 +- .../es/Sky150.10504.10603.plus.csv | 18 +- .../es/Sky150.10604.10605.csv | 18 +- .../es/Sky150.10604.10605.plus.csv | 18 +- .../es/Sky150.10606.10607.csv | 18 +- .../es/Sky150.10606.10607.plus.csv | 18 +- .../es/Sky150.10608.10706.csv | 18 +- .../es/Sky150.10608.10706.plus.csv | 18 +- .../es/Sky150.10801.10805.csv | 18 +- .../es/Sky150.10801.10805.plus.csv | 18 +- .../es/Sky150.10806.99999.csv | 18 +- .../es/Sky150.10806.99999.plus.csv | 18 +- .../es/Sky200.10702.10706.csv | 18 +- .../es/Sky200.10702.10706.plus.csv | 18 +- .../es/Sky200.10801.10805.csv | 18 +- .../es/Sky200.10801.10805.plus.csv | 18 +- .../es/Sky200.10806.99999.csv | 18 +- .../es/Sky200.10806.99999.plus.csv | 18 +- .../es/Sky300.10401.10403.csv | 18 +- .../es/Sky300.10401.10403.plus.csv | 18 +- .../es/Sky300.10502.10603.csv | 18 +- .../es/Sky300.10502.10603.plus.csv | 18 +- .../es/Sky300.10604.10605.csv | 18 +- .../es/Sky300.10604.10605.plus.csv | 18 +- .../es/Sky300.10606.10607.csv | 18 +- .../es/Sky300.10606.10607.plus.csv | 18 +- .../es/Sky300.10608.10706.csv | 18 +- .../es/Sky300.10608.10706.plus.csv | 18 +- .../es/Sky300.10801.10805.csv | 18 +- .../es/Sky300.10801.10805.plus.csv | 18 +- .../es/Sky300.10806.99999.csv | 18 +- .../es/Sky300.10806.99999.plus.csv | 18 +- .../es/ValveT01.0.99999.csv | 6 +- .../es/Vitovent200W.10104.10104.csv | 18 +- .../es/Vitovent200W.10104.10104.plus.csv | 18 +- .../es/Vitovent200W.10105.10105.csv | 18 +- .../es/Vitovent200W.10105.10105.plus.csv | 18 +- .../es/Vitovent200W.10106.99999.csv | 18 +- .../es/Vitovent200W.10106.99999.plus.csv | 18 +- .../es/Vitovent300C.10101.10105.csv | 18 +- .../es/Vitovent300C.10101.10105.plus.csv | 18 +- .../es/Vitovent300C.10106.99999.csv | 18 +- .../es/Vitovent300C.10106.99999.plus.csv | 18 +- .../es/Vitovent300W300.10101.10105.csv | 18 +- .../es/Vitovent300W300.10101.10105.plus.csv | 18 +- .../es/Vitovent300W300.10106.99999.csv | 18 +- .../es/Vitovent300W300.10106.99999.plus.csv | 18 +- .../es/Vitovent300W400.10101.10105.csv | 18 +- .../es/Vitovent300W400.10101.10105.plus.csv | 18 +- .../es/Vitovent300W400.10106.99999.csv | 18 +- .../es/Vitovent300W400.10106.99999.plus.csv | 18 +- .../es/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../es/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../es/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../es/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../es/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../es/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../es/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../es/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../fr/CWLF250.10806.10808.csv | 18 +- .../fr/CWLF250.10806.10808.plus.csv | 18 +- .../fr/CWLF250.10809.99999.csv | 18 +- .../fr/CWLF250.10809.99999.plus.csv | 18 +- .../fr/CWLF350.10806.10808.csv | 18 +- .../fr/CWLF350.10806.10808.plus.csv | 18 +- .../fr/CWLF350.10809.99999.csv | 18 +- .../fr/CWLF350.10809.99999.plus.csv | 18 +- .../fr/CWLTower300.10603.10603.csv | 18 +- .../fr/CWLTower300.10603.10603.plus.csv | 18 +- .../fr/CWLTower300.10604.10605.csv | 18 +- .../fr/CWLTower300.10604.10605.plus.csv | 18 +- .../fr/CWLTower300.10606.10607.csv | 18 +- .../fr/CWLTower300.10606.10607.plus.csv | 18 +- .../fr/CWLTower300.10608.10706.csv | 18 +- .../fr/CWLTower300.10608.10706.plus.csv | 18 +- .../fr/CWLTower300.10801.10805.csv | 18 +- .../fr/CWLTower300.10801.10805.plus.csv | 18 +- .../fr/CWLTower300.10806.99999.csv | 18 +- .../fr/CWLTower300.10806.99999.plus.csv | 18 +- .../fr/ConstantRPM400.10505.99999.csv | 18 +- .../fr/ConstantRPM400.10505.99999.plus.csv | 18 +- .../fr/DecentralAir70.10101.10700.csv | 16 +- .../fr/DecentralAir70.10101.10700.plus.csv | 16 +- .../fr/DecentralAir70.10701.99999.csv | 16 +- .../fr/DecentralAir70.10701.99999.plus.csv | 16 +- .../fr/Elan10.10103.99999.csv | 18 +- .../fr/Elan10.10103.99999.plus.csv | 18 +- .../fr/Elan4.10104.99999.csv | 18 +- .../fr/Elan4.10104.99999.plus.csv | 18 +- .../fr/Excellent180.10503.10603.csv | 18 +- .../fr/Excellent180.10503.10603.plus.csv | 18 +- .../fr/Excellent180.10604.10605.csv | 18 +- .../fr/Excellent180.10604.10605.plus.csv | 18 +- .../fr/Excellent180.10606.10607.csv | 18 +- .../fr/Excellent180.10606.10607.plus.csv | 18 +- .../fr/Excellent180.10608.10706.csv | 18 +- .../fr/Excellent180.10608.10706.plus.csv | 18 +- .../fr/Excellent180.10801.10805.csv | 18 +- .../fr/Excellent180.10801.10805.plus.csv | 18 +- .../fr/Excellent180.10806.99999.csv | 18 +- .../fr/Excellent180.10806.99999.plus.csv | 18 +- .../fr/Excellent300.10502.10603.csv | 18 +- .../fr/Excellent300.10502.10603.plus.csv | 18 +- .../fr/Excellent300.10604.10605.csv | 18 +- .../fr/Excellent300.10604.10605.plus.csv | 18 +- .../fr/Excellent300.10606.10607.csv | 18 +- .../fr/Excellent300.10606.10607.plus.csv | 18 +- .../fr/Excellent300.10608.10706.csv | 18 +- .../fr/Excellent300.10608.10706.plus.csv | 18 +- .../fr/Excellent300.10801.10805.csv | 18 +- .../fr/Excellent300.10801.10805.plus.csv | 18 +- .../fr/Excellent300.10806.99999.csv | 18 +- .../fr/Excellent300.10806.99999.plus.csv | 18 +- .../fr/Excellent400.10401.10403.csv | 18 +- .../fr/Excellent400.10401.10403.plus.csv | 18 +- .../fr/Excellent400.10502.10603.csv | 18 +- .../fr/Excellent400.10502.10603.plus.csv | 18 +- .../fr/Excellent400.10604.10605.csv | 18 +- .../fr/Excellent400.10604.10605.plus.csv | 18 +- .../fr/Excellent400.10606.10607.csv | 18 +- .../fr/Excellent400.10606.10607.plus.csv | 18 +- .../fr/Excellent400.10608.10706.csv | 18 +- .../fr/Excellent400.10608.10706.plus.csv | 18 +- .../fr/Excellent400.10801.10805.csv | 18 +- .../fr/Excellent400.10801.10805.plus.csv | 18 +- .../fr/Excellent400.10806.99999.csv | 18 +- .../fr/Excellent400.10806.99999.plus.csv | 18 +- .../fr/Excellent450.10604.10605.csv | 18 +- .../fr/Excellent450.10604.10605.plus.csv | 18 +- .../fr/Excellent450.10606.10607.csv | 18 +- .../fr/Excellent450.10606.10607.plus.csv | 18 +- .../fr/Excellent450.10608.10706.csv | 18 +- .../fr/Excellent450.10608.10706.plus.csv | 18 +- .../fr/Excellent450.10801.10805.csv | 18 +- .../fr/Excellent450.10801.10805.plus.csv | 18 +- .../fr/Excellent450.10806.99999.csv | 18 +- .../fr/Excellent450.10806.99999.plus.csv | 18 +- .../fr/Flair200.10101.99999.csv | 18 +- .../fr/Flair225.10101.99999.csv | 18 +- .../fr/Flair300.10101.20105.csv | 18 +- .../fr/Flair300.20106.99999.csv | 18 +- .../fr/Flair325.10101.20105.csv | 18 +- .../fr/Flair325.20106.99999.csv | 18 +- .../fr/Flair400.10101.20105.csv | 18 +- .../fr/Flair400.20106.99999.csv | 18 +- .../fr/Flair450.10101.99999.csv | 18 +- .../fr/Flair600.10101.99999.csv | 18 +- .../fr/MultiRoomCtrlT01.0.10101.csv | 6 +- .../fr/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../fr/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../fr/Nather300.10703.10706.csv | 18 +- .../fr/Nather300.10703.10706.plus.csv | 18 +- .../fr/Nather300.10801.10805.csv | 18 +- .../fr/Nather300.10801.10805.plus.csv | 18 +- .../fr/Nather300.10806.99999.csv | 18 +- .../fr/Nather300.10806.99999.plus.csv | 18 +- .../fr/RenoventElan300.10604.10605.csv | 18 +- .../fr/RenoventElan300.10604.10605.plus.csv | 18 +- .../fr/RenoventElan300.10606.10607.csv | 18 +- .../fr/RenoventElan300.10606.10607.plus.csv | 18 +- .../fr/RenoventElan300.10608.10706.csv | 18 +- .../fr/RenoventElan300.10608.10706.plus.csv | 18 +- .../fr/RenoventElan300.10801.10805.csv | 18 +- .../fr/RenoventElan300.10801.10805.plus.csv | 18 +- .../fr/RenoventElan300.10806.99999.csv | 18 +- .../fr/RenoventElan300.10806.99999.plus.csv | 18 +- .../fr/Sky150.10504.10603.csv | 18 +- .../fr/Sky150.10504.10603.plus.csv | 18 +- .../fr/Sky150.10604.10605.csv | 18 +- .../fr/Sky150.10604.10605.plus.csv | 18 +- .../fr/Sky150.10606.10607.csv | 18 +- .../fr/Sky150.10606.10607.plus.csv | 18 +- .../fr/Sky150.10608.10706.csv | 18 +- .../fr/Sky150.10608.10706.plus.csv | 18 +- .../fr/Sky150.10801.10805.csv | 18 +- .../fr/Sky150.10801.10805.plus.csv | 18 +- .../fr/Sky150.10806.99999.csv | 18 +- .../fr/Sky150.10806.99999.plus.csv | 18 +- .../fr/Sky200.10702.10706.csv | 18 +- .../fr/Sky200.10702.10706.plus.csv | 18 +- .../fr/Sky200.10801.10805.csv | 18 +- .../fr/Sky200.10801.10805.plus.csv | 18 +- .../fr/Sky200.10806.99999.csv | 18 +- .../fr/Sky200.10806.99999.plus.csv | 18 +- .../fr/Sky300.10401.10403.csv | 18 +- .../fr/Sky300.10401.10403.plus.csv | 18 +- .../fr/Sky300.10502.10603.csv | 18 +- .../fr/Sky300.10502.10603.plus.csv | 18 +- .../fr/Sky300.10604.10605.csv | 18 +- .../fr/Sky300.10604.10605.plus.csv | 18 +- .../fr/Sky300.10606.10607.csv | 18 +- .../fr/Sky300.10606.10607.plus.csv | 18 +- .../fr/Sky300.10608.10706.csv | 18 +- .../fr/Sky300.10608.10706.plus.csv | 18 +- .../fr/Sky300.10801.10805.csv | 18 +- .../fr/Sky300.10801.10805.plus.csv | 18 +- .../fr/Sky300.10806.99999.csv | 18 +- .../fr/Sky300.10806.99999.plus.csv | 18 +- .../fr/ValveT01.0.99999.csv | 6 +- .../fr/Vitovent200W.10104.10104.csv | 18 +- .../fr/Vitovent200W.10104.10104.plus.csv | 18 +- .../fr/Vitovent200W.10105.10105.csv | 18 +- .../fr/Vitovent200W.10105.10105.plus.csv | 18 +- .../fr/Vitovent200W.10106.99999.csv | 18 +- .../fr/Vitovent200W.10106.99999.plus.csv | 18 +- .../fr/Vitovent300C.10101.10105.csv | 18 +- .../fr/Vitovent300C.10101.10105.plus.csv | 18 +- .../fr/Vitovent300C.10106.99999.csv | 18 +- .../fr/Vitovent300C.10106.99999.plus.csv | 18 +- .../fr/Vitovent300W300.10101.10105.csv | 18 +- .../fr/Vitovent300W300.10101.10105.plus.csv | 18 +- .../fr/Vitovent300W300.10106.99999.csv | 18 +- .../fr/Vitovent300W300.10106.99999.plus.csv | 18 +- .../fr/Vitovent300W400.10101.10105.csv | 18 +- .../fr/Vitovent300W400.10101.10105.plus.csv | 18 +- .../fr/Vitovent300W400.10106.99999.csv | 18 +- .../fr/Vitovent300W400.10106.99999.plus.csv | 18 +- .../fr/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../fr/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../fr/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../fr/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../fr/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../fr/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../fr/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../fr/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../it/CWLF250.10806.10808.csv | 18 +- .../it/CWLF250.10806.10808.plus.csv | 18 +- .../it/CWLF250.10809.99999.csv | 18 +- .../it/CWLF250.10809.99999.plus.csv | 18 +- .../it/CWLF350.10806.10808.csv | 18 +- .../it/CWLF350.10806.10808.plus.csv | 18 +- .../it/CWLF350.10809.99999.csv | 18 +- .../it/CWLF350.10809.99999.plus.csv | 18 +- .../it/CWLTower300.10603.10603.csv | 18 +- .../it/CWLTower300.10603.10603.plus.csv | 18 +- .../it/CWLTower300.10604.10605.csv | 18 +- .../it/CWLTower300.10604.10605.plus.csv | 18 +- .../it/CWLTower300.10606.10607.csv | 18 +- .../it/CWLTower300.10606.10607.plus.csv | 18 +- .../it/CWLTower300.10608.10706.csv | 18 +- .../it/CWLTower300.10608.10706.plus.csv | 18 +- .../it/CWLTower300.10801.10805.csv | 18 +- .../it/CWLTower300.10801.10805.plus.csv | 18 +- .../it/CWLTower300.10806.99999.csv | 18 +- .../it/CWLTower300.10806.99999.plus.csv | 18 +- .../it/ConstantRPM400.10505.99999.csv | 18 +- .../it/ConstantRPM400.10505.99999.plus.csv | 18 +- .../it/DecentralAir70.10101.10700.csv | 16 +- .../it/DecentralAir70.10101.10700.plus.csv | 16 +- .../it/DecentralAir70.10701.99999.csv | 16 +- .../it/DecentralAir70.10701.99999.plus.csv | 16 +- .../it/Elan10.10103.99999.csv | 18 +- .../it/Elan10.10103.99999.plus.csv | 18 +- .../it/Elan4.10104.99999.csv | 18 +- .../it/Elan4.10104.99999.plus.csv | 18 +- .../it/Excellent180.10503.10603.csv | 18 +- .../it/Excellent180.10503.10603.plus.csv | 18 +- .../it/Excellent180.10604.10605.csv | 18 +- .../it/Excellent180.10604.10605.plus.csv | 18 +- .../it/Excellent180.10606.10607.csv | 18 +- .../it/Excellent180.10606.10607.plus.csv | 18 +- .../it/Excellent180.10608.10706.csv | 18 +- .../it/Excellent180.10608.10706.plus.csv | 18 +- .../it/Excellent180.10801.10805.csv | 18 +- .../it/Excellent180.10801.10805.plus.csv | 18 +- .../it/Excellent180.10806.99999.csv | 18 +- .../it/Excellent180.10806.99999.plus.csv | 18 +- .../it/Excellent300.10502.10603.csv | 18 +- .../it/Excellent300.10502.10603.plus.csv | 18 +- .../it/Excellent300.10604.10605.csv | 18 +- .../it/Excellent300.10604.10605.plus.csv | 18 +- .../it/Excellent300.10606.10607.csv | 18 +- .../it/Excellent300.10606.10607.plus.csv | 18 +- .../it/Excellent300.10608.10706.csv | 18 +- .../it/Excellent300.10608.10706.plus.csv | 18 +- .../it/Excellent300.10801.10805.csv | 18 +- .../it/Excellent300.10801.10805.plus.csv | 18 +- .../it/Excellent300.10806.99999.csv | 18 +- .../it/Excellent300.10806.99999.plus.csv | 18 +- .../it/Excellent400.10401.10403.csv | 18 +- .../it/Excellent400.10401.10403.plus.csv | 18 +- .../it/Excellent400.10502.10603.csv | 18 +- .../it/Excellent400.10502.10603.plus.csv | 18 +- .../it/Excellent400.10604.10605.csv | 18 +- .../it/Excellent400.10604.10605.plus.csv | 18 +- .../it/Excellent400.10606.10607.csv | 18 +- .../it/Excellent400.10606.10607.plus.csv | 18 +- .../it/Excellent400.10608.10706.csv | 18 +- .../it/Excellent400.10608.10706.plus.csv | 18 +- .../it/Excellent400.10801.10805.csv | 18 +- .../it/Excellent400.10801.10805.plus.csv | 18 +- .../it/Excellent400.10806.99999.csv | 18 +- .../it/Excellent400.10806.99999.plus.csv | 18 +- .../it/Excellent450.10604.10605.csv | 18 +- .../it/Excellent450.10604.10605.plus.csv | 18 +- .../it/Excellent450.10606.10607.csv | 18 +- .../it/Excellent450.10606.10607.plus.csv | 18 +- .../it/Excellent450.10608.10706.csv | 18 +- .../it/Excellent450.10608.10706.plus.csv | 18 +- .../it/Excellent450.10801.10805.csv | 18 +- .../it/Excellent450.10801.10805.plus.csv | 18 +- .../it/Excellent450.10806.99999.csv | 18 +- .../it/Excellent450.10806.99999.plus.csv | 18 +- .../it/Flair200.10101.99999.csv | 18 +- .../it/Flair225.10101.99999.csv | 18 +- .../it/Flair300.10101.20105.csv | 18 +- .../it/Flair300.20106.99999.csv | 18 +- .../it/Flair325.10101.20105.csv | 18 +- .../it/Flair325.20106.99999.csv | 18 +- .../it/Flair400.10101.20105.csv | 18 +- .../it/Flair400.20106.99999.csv | 18 +- .../it/Flair450.10101.99999.csv | 18 +- .../it/Flair600.10101.99999.csv | 18 +- .../it/MultiRoomCtrlT01.0.10101.csv | 6 +- .../it/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../it/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../it/Nather300.10703.10706.csv | 18 +- .../it/Nather300.10703.10706.plus.csv | 18 +- .../it/Nather300.10801.10805.csv | 18 +- .../it/Nather300.10801.10805.plus.csv | 18 +- .../it/Nather300.10806.99999.csv | 18 +- .../it/Nather300.10806.99999.plus.csv | 18 +- .../it/RenoventElan300.10604.10605.csv | 18 +- .../it/RenoventElan300.10604.10605.plus.csv | 18 +- .../it/RenoventElan300.10606.10607.csv | 18 +- .../it/RenoventElan300.10606.10607.plus.csv | 18 +- .../it/RenoventElan300.10608.10706.csv | 18 +- .../it/RenoventElan300.10608.10706.plus.csv | 18 +- .../it/RenoventElan300.10801.10805.csv | 18 +- .../it/RenoventElan300.10801.10805.plus.csv | 18 +- .../it/RenoventElan300.10806.99999.csv | 18 +- .../it/RenoventElan300.10806.99999.plus.csv | 18 +- .../it/Sky150.10504.10603.csv | 18 +- .../it/Sky150.10504.10603.plus.csv | 18 +- .../it/Sky150.10604.10605.csv | 18 +- .../it/Sky150.10604.10605.plus.csv | 18 +- .../it/Sky150.10606.10607.csv | 18 +- .../it/Sky150.10606.10607.plus.csv | 18 +- .../it/Sky150.10608.10706.csv | 18 +- .../it/Sky150.10608.10706.plus.csv | 18 +- .../it/Sky150.10801.10805.csv | 18 +- .../it/Sky150.10801.10805.plus.csv | 18 +- .../it/Sky150.10806.99999.csv | 18 +- .../it/Sky150.10806.99999.plus.csv | 18 +- .../it/Sky200.10702.10706.csv | 18 +- .../it/Sky200.10702.10706.plus.csv | 18 +- .../it/Sky200.10801.10805.csv | 18 +- .../it/Sky200.10801.10805.plus.csv | 18 +- .../it/Sky200.10806.99999.csv | 18 +- .../it/Sky200.10806.99999.plus.csv | 18 +- .../it/Sky300.10401.10403.csv | 18 +- .../it/Sky300.10401.10403.plus.csv | 18 +- .../it/Sky300.10502.10603.csv | 18 +- .../it/Sky300.10502.10603.plus.csv | 18 +- .../it/Sky300.10604.10605.csv | 18 +- .../it/Sky300.10604.10605.plus.csv | 18 +- .../it/Sky300.10606.10607.csv | 18 +- .../it/Sky300.10606.10607.plus.csv | 18 +- .../it/Sky300.10608.10706.csv | 18 +- .../it/Sky300.10608.10706.plus.csv | 18 +- .../it/Sky300.10801.10805.csv | 18 +- .../it/Sky300.10801.10805.plus.csv | 18 +- .../it/Sky300.10806.99999.csv | 18 +- .../it/Sky300.10806.99999.plus.csv | 18 +- .../it/ValveT01.0.99999.csv | 6 +- .../it/Vitovent200W.10104.10104.csv | 18 +- .../it/Vitovent200W.10104.10104.plus.csv | 18 +- .../it/Vitovent200W.10105.10105.csv | 18 +- .../it/Vitovent200W.10105.10105.plus.csv | 18 +- .../it/Vitovent200W.10106.99999.csv | 18 +- .../it/Vitovent200W.10106.99999.plus.csv | 18 +- .../it/Vitovent300C.10101.10105.csv | 18 +- .../it/Vitovent300C.10101.10105.plus.csv | 18 +- .../it/Vitovent300C.10106.99999.csv | 18 +- .../it/Vitovent300C.10106.99999.plus.csv | 18 +- .../it/Vitovent300W300.10101.10105.csv | 18 +- .../it/Vitovent300W300.10101.10105.plus.csv | 18 +- .../it/Vitovent300W300.10106.99999.csv | 18 +- .../it/Vitovent300W300.10106.99999.plus.csv | 18 +- .../it/Vitovent300W400.10101.10105.csv | 18 +- .../it/Vitovent300W400.10101.10105.plus.csv | 18 +- .../it/Vitovent300W400.10106.99999.csv | 18 +- .../it/Vitovent300W400.10106.99999.plus.csv | 18 +- .../it/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../it/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../it/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../it/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../it/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../it/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../it/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../it/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../nl/CWLF250.10806.10808.csv | 18 +- .../nl/CWLF250.10806.10808.plus.csv | 18 +- .../nl/CWLF250.10809.99999.csv | 18 +- .../nl/CWLF250.10809.99999.plus.csv | 18 +- .../nl/CWLF350.10806.10808.csv | 18 +- .../nl/CWLF350.10806.10808.plus.csv | 18 +- .../nl/CWLF350.10809.99999.csv | 18 +- .../nl/CWLF350.10809.99999.plus.csv | 18 +- .../nl/CWLTower300.10603.10603.csv | 18 +- .../nl/CWLTower300.10603.10603.plus.csv | 18 +- .../nl/CWLTower300.10604.10605.csv | 18 +- .../nl/CWLTower300.10604.10605.plus.csv | 18 +- .../nl/CWLTower300.10606.10607.csv | 18 +- .../nl/CWLTower300.10606.10607.plus.csv | 18 +- .../nl/CWLTower300.10608.10706.csv | 18 +- .../nl/CWLTower300.10608.10706.plus.csv | 18 +- .../nl/CWLTower300.10801.10805.csv | 18 +- .../nl/CWLTower300.10801.10805.plus.csv | 18 +- .../nl/CWLTower300.10806.99999.csv | 18 +- .../nl/CWLTower300.10806.99999.plus.csv | 18 +- .../nl/ConstantRPM400.10505.99999.csv | 18 +- .../nl/ConstantRPM400.10505.99999.plus.csv | 18 +- .../nl/DecentralAir70.10101.10700.csv | 16 +- .../nl/DecentralAir70.10101.10700.plus.csv | 16 +- .../nl/DecentralAir70.10701.99999.csv | 16 +- .../nl/DecentralAir70.10701.99999.plus.csv | 16 +- .../nl/Elan10.10103.99999.csv | 18 +- .../nl/Elan10.10103.99999.plus.csv | 18 +- .../nl/Elan4.10104.99999.csv | 18 +- .../nl/Elan4.10104.99999.plus.csv | 18 +- .../nl/Excellent180.10503.10603.csv | 18 +- .../nl/Excellent180.10503.10603.plus.csv | 18 +- .../nl/Excellent180.10604.10605.csv | 18 +- .../nl/Excellent180.10604.10605.plus.csv | 18 +- .../nl/Excellent180.10606.10607.csv | 18 +- .../nl/Excellent180.10606.10607.plus.csv | 18 +- .../nl/Excellent180.10608.10706.csv | 18 +- .../nl/Excellent180.10608.10706.plus.csv | 18 +- .../nl/Excellent180.10801.10805.csv | 18 +- .../nl/Excellent180.10801.10805.plus.csv | 18 +- .../nl/Excellent180.10806.99999.csv | 18 +- .../nl/Excellent180.10806.99999.plus.csv | 18 +- .../nl/Excellent300.10502.10603.csv | 18 +- .../nl/Excellent300.10502.10603.plus.csv | 18 +- .../nl/Excellent300.10604.10605.csv | 18 +- .../nl/Excellent300.10604.10605.plus.csv | 18 +- .../nl/Excellent300.10606.10607.csv | 18 +- .../nl/Excellent300.10606.10607.plus.csv | 18 +- .../nl/Excellent300.10608.10706.csv | 18 +- .../nl/Excellent300.10608.10706.plus.csv | 18 +- .../nl/Excellent300.10801.10805.csv | 18 +- .../nl/Excellent300.10801.10805.plus.csv | 18 +- .../nl/Excellent300.10806.99999.csv | 18 +- .../nl/Excellent300.10806.99999.plus.csv | 18 +- .../nl/Excellent400.10401.10403.csv | 18 +- .../nl/Excellent400.10401.10403.plus.csv | 18 +- .../nl/Excellent400.10502.10603.csv | 18 +- .../nl/Excellent400.10502.10603.plus.csv | 18 +- .../nl/Excellent400.10604.10605.csv | 18 +- .../nl/Excellent400.10604.10605.plus.csv | 18 +- .../nl/Excellent400.10606.10607.csv | 18 +- .../nl/Excellent400.10606.10607.plus.csv | 18 +- .../nl/Excellent400.10608.10706.csv | 18 +- .../nl/Excellent400.10608.10706.plus.csv | 18 +- .../nl/Excellent400.10801.10805.csv | 18 +- .../nl/Excellent400.10801.10805.plus.csv | 18 +- .../nl/Excellent400.10806.99999.csv | 18 +- .../nl/Excellent400.10806.99999.plus.csv | 18 +- .../nl/Excellent450.10604.10605.csv | 18 +- .../nl/Excellent450.10604.10605.plus.csv | 18 +- .../nl/Excellent450.10606.10607.csv | 18 +- .../nl/Excellent450.10606.10607.plus.csv | 18 +- .../nl/Excellent450.10608.10706.csv | 18 +- .../nl/Excellent450.10608.10706.plus.csv | 18 +- .../nl/Excellent450.10801.10805.csv | 18 +- .../nl/Excellent450.10801.10805.plus.csv | 18 +- .../nl/Excellent450.10806.99999.csv | 18 +- .../nl/Excellent450.10806.99999.plus.csv | 18 +- .../nl/Flair200.10101.99999.csv | 18 +- .../nl/Flair225.10101.99999.csv | 18 +- .../nl/Flair300.10101.20105.csv | 18 +- .../nl/Flair300.20106.99999.csv | 18 +- .../nl/Flair325.10101.20105.csv | 18 +- .../nl/Flair325.20106.99999.csv | 18 +- .../nl/Flair400.10101.20105.csv | 18 +- .../nl/Flair400.20106.99999.csv | 18 +- .../nl/Flair450.10101.99999.csv | 18 +- .../nl/Flair600.10101.99999.csv | 18 +- .../nl/MultiRoomCtrlT01.0.10101.csv | 6 +- .../nl/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../nl/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../nl/Nather300.10703.10706.csv | 18 +- .../nl/Nather300.10703.10706.plus.csv | 18 +- .../nl/Nather300.10801.10805.csv | 18 +- .../nl/Nather300.10801.10805.plus.csv | 18 +- .../nl/Nather300.10806.99999.csv | 18 +- .../nl/Nather300.10806.99999.plus.csv | 18 +- .../nl/RenoventElan300.10604.10605.csv | 18 +- .../nl/RenoventElan300.10604.10605.plus.csv | 18 +- .../nl/RenoventElan300.10606.10607.csv | 18 +- .../nl/RenoventElan300.10606.10607.plus.csv | 18 +- .../nl/RenoventElan300.10608.10706.csv | 18 +- .../nl/RenoventElan300.10608.10706.plus.csv | 18 +- .../nl/RenoventElan300.10801.10805.csv | 18 +- .../nl/RenoventElan300.10801.10805.plus.csv | 18 +- .../nl/RenoventElan300.10806.99999.csv | 18 +- .../nl/RenoventElan300.10806.99999.plus.csv | 18 +- .../nl/Sky150.10504.10603.csv | 18 +- .../nl/Sky150.10504.10603.plus.csv | 18 +- .../nl/Sky150.10604.10605.csv | 18 +- .../nl/Sky150.10604.10605.plus.csv | 18 +- .../nl/Sky150.10606.10607.csv | 18 +- .../nl/Sky150.10606.10607.plus.csv | 18 +- .../nl/Sky150.10608.10706.csv | 18 +- .../nl/Sky150.10608.10706.plus.csv | 18 +- .../nl/Sky150.10801.10805.csv | 18 +- .../nl/Sky150.10801.10805.plus.csv | 18 +- .../nl/Sky150.10806.99999.csv | 18 +- .../nl/Sky150.10806.99999.plus.csv | 18 +- .../nl/Sky200.10702.10706.csv | 18 +- .../nl/Sky200.10702.10706.plus.csv | 18 +- .../nl/Sky200.10801.10805.csv | 18 +- .../nl/Sky200.10801.10805.plus.csv | 18 +- .../nl/Sky200.10806.99999.csv | 18 +- .../nl/Sky200.10806.99999.plus.csv | 18 +- .../nl/Sky300.10401.10403.csv | 18 +- .../nl/Sky300.10401.10403.plus.csv | 18 +- .../nl/Sky300.10502.10603.csv | 18 +- .../nl/Sky300.10502.10603.plus.csv | 18 +- .../nl/Sky300.10604.10605.csv | 18 +- .../nl/Sky300.10604.10605.plus.csv | 18 +- .../nl/Sky300.10606.10607.csv | 18 +- .../nl/Sky300.10606.10607.plus.csv | 18 +- .../nl/Sky300.10608.10706.csv | 18 +- .../nl/Sky300.10608.10706.plus.csv | 18 +- .../nl/Sky300.10801.10805.csv | 18 +- .../nl/Sky300.10801.10805.plus.csv | 18 +- .../nl/Sky300.10806.99999.csv | 18 +- .../nl/Sky300.10806.99999.plus.csv | 18 +- .../nl/ValveT01.0.99999.csv | 6 +- .../nl/Vitovent200W.10104.10104.csv | 18 +- .../nl/Vitovent200W.10104.10104.plus.csv | 18 +- .../nl/Vitovent200W.10105.10105.csv | 18 +- .../nl/Vitovent200W.10105.10105.plus.csv | 18 +- .../nl/Vitovent200W.10106.99999.csv | 18 +- .../nl/Vitovent200W.10106.99999.plus.csv | 18 +- .../nl/Vitovent300C.10101.10105.csv | 18 +- .../nl/Vitovent300C.10101.10105.plus.csv | 18 +- .../nl/Vitovent300C.10106.99999.csv | 18 +- .../nl/Vitovent300C.10106.99999.plus.csv | 18 +- .../nl/Vitovent300W300.10101.10105.csv | 18 +- .../nl/Vitovent300W300.10101.10105.plus.csv | 18 +- .../nl/Vitovent300W300.10106.99999.csv | 18 +- .../nl/Vitovent300W300.10106.99999.plus.csv | 18 +- .../nl/Vitovent300W400.10101.10105.csv | 18 +- .../nl/Vitovent300W400.10101.10105.plus.csv | 18 +- .../nl/Vitovent300W400.10106.99999.csv | 18 +- .../nl/Vitovent300W400.10106.99999.plus.csv | 18 +- .../nl/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../nl/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../nl/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../nl/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../nl/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../nl/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../nl/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../nl/Vitovent300WH32SC400.10111.99999.csv | 18 +- .../pl/CWLF250.10806.10808.csv | 18 +- .../pl/CWLF250.10806.10808.plus.csv | 18 +- .../pl/CWLF250.10809.99999.csv | 18 +- .../pl/CWLF250.10809.99999.plus.csv | 18 +- .../pl/CWLF350.10806.10808.csv | 18 +- .../pl/CWLF350.10806.10808.plus.csv | 18 +- .../pl/CWLF350.10809.99999.csv | 18 +- .../pl/CWLF350.10809.99999.plus.csv | 18 +- .../pl/CWLTower300.10603.10603.csv | 18 +- .../pl/CWLTower300.10603.10603.plus.csv | 18 +- .../pl/CWLTower300.10604.10605.csv | 18 +- .../pl/CWLTower300.10604.10605.plus.csv | 18 +- .../pl/CWLTower300.10606.10607.csv | 18 +- .../pl/CWLTower300.10606.10607.plus.csv | 18 +- .../pl/CWLTower300.10608.10706.csv | 18 +- .../pl/CWLTower300.10608.10706.plus.csv | 18 +- .../pl/CWLTower300.10801.10805.csv | 18 +- .../pl/CWLTower300.10801.10805.plus.csv | 18 +- .../pl/CWLTower300.10806.99999.csv | 18 +- .../pl/CWLTower300.10806.99999.plus.csv | 18 +- .../pl/ConstantRPM400.10505.99999.csv | 18 +- .../pl/ConstantRPM400.10505.99999.plus.csv | 18 +- .../pl/DecentralAir70.10101.10700.csv | 16 +- .../pl/DecentralAir70.10101.10700.plus.csv | 16 +- .../pl/DecentralAir70.10701.99999.csv | 16 +- .../pl/DecentralAir70.10701.99999.plus.csv | 16 +- .../pl/Elan10.10103.99999.csv | 18 +- .../pl/Elan10.10103.99999.plus.csv | 18 +- .../pl/Elan4.10104.99999.csv | 18 +- .../pl/Elan4.10104.99999.plus.csv | 18 +- .../pl/Excellent180.10503.10603.csv | 18 +- .../pl/Excellent180.10503.10603.plus.csv | 18 +- .../pl/Excellent180.10604.10605.csv | 18 +- .../pl/Excellent180.10604.10605.plus.csv | 18 +- .../pl/Excellent180.10606.10607.csv | 18 +- .../pl/Excellent180.10606.10607.plus.csv | 18 +- .../pl/Excellent180.10608.10706.csv | 18 +- .../pl/Excellent180.10608.10706.plus.csv | 18 +- .../pl/Excellent180.10801.10805.csv | 18 +- .../pl/Excellent180.10801.10805.plus.csv | 18 +- .../pl/Excellent180.10806.99999.csv | 18 +- .../pl/Excellent180.10806.99999.plus.csv | 18 +- .../pl/Excellent300.10502.10603.csv | 18 +- .../pl/Excellent300.10502.10603.plus.csv | 18 +- .../pl/Excellent300.10604.10605.csv | 18 +- .../pl/Excellent300.10604.10605.plus.csv | 18 +- .../pl/Excellent300.10606.10607.csv | 18 +- .../pl/Excellent300.10606.10607.plus.csv | 18 +- .../pl/Excellent300.10608.10706.csv | 18 +- .../pl/Excellent300.10608.10706.plus.csv | 18 +- .../pl/Excellent300.10801.10805.csv | 18 +- .../pl/Excellent300.10801.10805.plus.csv | 18 +- .../pl/Excellent300.10806.99999.csv | 18 +- .../pl/Excellent300.10806.99999.plus.csv | 18 +- .../pl/Excellent400.10401.10403.csv | 18 +- .../pl/Excellent400.10401.10403.plus.csv | 18 +- .../pl/Excellent400.10502.10603.csv | 18 +- .../pl/Excellent400.10502.10603.plus.csv | 18 +- .../pl/Excellent400.10604.10605.csv | 18 +- .../pl/Excellent400.10604.10605.plus.csv | 18 +- .../pl/Excellent400.10606.10607.csv | 18 +- .../pl/Excellent400.10606.10607.plus.csv | 18 +- .../pl/Excellent400.10608.10706.csv | 18 +- .../pl/Excellent400.10608.10706.plus.csv | 18 +- .../pl/Excellent400.10801.10805.csv | 18 +- .../pl/Excellent400.10801.10805.plus.csv | 18 +- .../pl/Excellent400.10806.99999.csv | 18 +- .../pl/Excellent400.10806.99999.plus.csv | 18 +- .../pl/Excellent450.10604.10605.csv | 18 +- .../pl/Excellent450.10604.10605.plus.csv | 18 +- .../pl/Excellent450.10606.10607.csv | 18 +- .../pl/Excellent450.10606.10607.plus.csv | 18 +- .../pl/Excellent450.10608.10706.csv | 18 +- .../pl/Excellent450.10608.10706.plus.csv | 18 +- .../pl/Excellent450.10801.10805.csv | 18 +- .../pl/Excellent450.10801.10805.plus.csv | 18 +- .../pl/Excellent450.10806.99999.csv | 18 +- .../pl/Excellent450.10806.99999.plus.csv | 18 +- .../pl/Flair200.10101.99999.csv | 18 +- .../pl/Flair225.10101.99999.csv | 18 +- .../pl/Flair300.10101.20105.csv | 18 +- .../pl/Flair300.20106.99999.csv | 18 +- .../pl/Flair325.10101.20105.csv | 18 +- .../pl/Flair325.20106.99999.csv | 18 +- .../pl/Flair400.10101.20105.csv | 18 +- .../pl/Flair400.20106.99999.csv | 18 +- .../pl/Flair450.10101.99999.csv | 18 +- .../pl/Flair600.10101.99999.csv | 18 +- .../pl/MultiRoomCtrlT01.0.10101.csv | 6 +- .../pl/MultiRoomCtrlT01.10102.10102.csv | 6 +- .../pl/MultiRoomCtrlT01.10103.99999.csv | 6 +- .../pl/Nather300.10703.10706.csv | 18 +- .../pl/Nather300.10703.10706.plus.csv | 18 +- .../pl/Nather300.10801.10805.csv | 18 +- .../pl/Nather300.10801.10805.plus.csv | 18 +- .../pl/Nather300.10806.99999.csv | 18 +- .../pl/Nather300.10806.99999.plus.csv | 18 +- .../pl/RenoventElan300.10604.10605.csv | 18 +- .../pl/RenoventElan300.10604.10605.plus.csv | 18 +- .../pl/RenoventElan300.10606.10607.csv | 18 +- .../pl/RenoventElan300.10606.10607.plus.csv | 18 +- .../pl/RenoventElan300.10608.10706.csv | 18 +- .../pl/RenoventElan300.10608.10706.plus.csv | 18 +- .../pl/RenoventElan300.10801.10805.csv | 18 +- .../pl/RenoventElan300.10801.10805.plus.csv | 18 +- .../pl/RenoventElan300.10806.99999.csv | 18 +- .../pl/RenoventElan300.10806.99999.plus.csv | 18 +- .../pl/Sky150.10504.10603.csv | 18 +- .../pl/Sky150.10504.10603.plus.csv | 18 +- .../pl/Sky150.10604.10605.csv | 18 +- .../pl/Sky150.10604.10605.plus.csv | 18 +- .../pl/Sky150.10606.10607.csv | 18 +- .../pl/Sky150.10606.10607.plus.csv | 18 +- .../pl/Sky150.10608.10706.csv | 18 +- .../pl/Sky150.10608.10706.plus.csv | 18 +- .../pl/Sky150.10801.10805.csv | 18 +- .../pl/Sky150.10801.10805.plus.csv | 18 +- .../pl/Sky150.10806.99999.csv | 18 +- .../pl/Sky150.10806.99999.plus.csv | 18 +- .../pl/Sky200.10702.10706.csv | 18 +- .../pl/Sky200.10702.10706.plus.csv | 18 +- .../pl/Sky200.10801.10805.csv | 18 +- .../pl/Sky200.10801.10805.plus.csv | 18 +- .../pl/Sky200.10806.99999.csv | 18 +- .../pl/Sky200.10806.99999.plus.csv | 18 +- .../pl/Sky300.10401.10403.csv | 18 +- .../pl/Sky300.10401.10403.plus.csv | 18 +- .../pl/Sky300.10502.10603.csv | 18 +- .../pl/Sky300.10502.10603.plus.csv | 18 +- .../pl/Sky300.10604.10605.csv | 18 +- .../pl/Sky300.10604.10605.plus.csv | 18 +- .../pl/Sky300.10606.10607.csv | 18 +- .../pl/Sky300.10606.10607.plus.csv | 18 +- .../pl/Sky300.10608.10706.csv | 18 +- .../pl/Sky300.10608.10706.plus.csv | 18 +- .../pl/Sky300.10801.10805.csv | 18 +- .../pl/Sky300.10801.10805.plus.csv | 18 +- .../pl/Sky300.10806.99999.csv | 18 +- .../pl/Sky300.10806.99999.plus.csv | 18 +- .../pl/ValveT01.0.99999.csv | 6 +- .../pl/Vitovent200W.10104.10104.csv | 18 +- .../pl/Vitovent200W.10104.10104.plus.csv | 18 +- .../pl/Vitovent200W.10105.10105.csv | 18 +- .../pl/Vitovent200W.10105.10105.plus.csv | 18 +- .../pl/Vitovent200W.10106.99999.csv | 18 +- .../pl/Vitovent200W.10106.99999.plus.csv | 18 +- .../pl/Vitovent300C.10101.10105.csv | 18 +- .../pl/Vitovent300C.10101.10105.plus.csv | 18 +- .../pl/Vitovent300C.10106.99999.csv | 18 +- .../pl/Vitovent300C.10106.99999.plus.csv | 18 +- .../pl/Vitovent300W300.10101.10105.csv | 18 +- .../pl/Vitovent300W300.10101.10105.plus.csv | 18 +- .../pl/Vitovent300W300.10106.99999.csv | 18 +- .../pl/Vitovent300W300.10106.99999.plus.csv | 18 +- .../pl/Vitovent300W400.10101.10105.csv | 18 +- .../pl/Vitovent300W400.10101.10105.plus.csv | 18 +- .../pl/Vitovent300W400.10106.99999.csv | 18 +- .../pl/Vitovent300W400.10106.99999.plus.csv | 18 +- .../pl/Vitovent300WH32SA225.10101.10109.csv | 18 +- .../pl/Vitovent300WH32SA225.10110.10110.csv | 18 +- .../pl/Vitovent300WH32SA225.10111.99999.csv | 18 +- .../pl/Vitovent300WH32SA600.10101.99999.csv | 18 +- .../pl/Vitovent300WH32SC325.10101.10110.csv | 18 +- .../pl/Vitovent300WH32SC325.10111.99999.csv | 18 +- .../pl/Vitovent300WH32SC400.10101.10110.csv | 18 +- .../pl/Vitovent300WH32SC400.10111.99999.csv | 18 +- src/ebus_message.py | 34 +-- src/out.py | 4 +- 1354 files changed, 10472 insertions(+), 32686 deletions(-) delete mode 100644 ebusd-configuration-known-slave-address/3c.Excellent300.csv delete mode 100644 ebusd-configuration-known-slave-address/3c.Sky300.csv delete mode 100644 ebusd-configuration-known-slave-address/7c.Excellent400.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.csv delete mode 100644 ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Elan10.10103.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Elan10.10103.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Elan4.10104.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Elan4.10104.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair200.10101.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair225.10101.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair300.10101.20105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair300.20106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair325.10101.20105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair325.20106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair400.10101.20105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair400.20106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair450.10101.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Flair600.10101.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.0.10101.csv delete mode 100644 ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10102.10102.csv delete mode 100644 ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10103.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10703.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10703.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Nather300.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10504.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10504.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky150.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10702.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10702.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky200.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10401.10403.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10401.10403.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10502.10603.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10502.10603.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10604.10605.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10604.10605.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10606.10607.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10606.10607.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10608.10706.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10608.10706.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10801.10805.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10801.10805.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10806.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Sky300.10806.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/ValveT01.0.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.plus.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10101.10109.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10110.10110.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10111.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SA600.10101.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10101.10110.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10111.99999.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10101.10110.csv delete mode 100644 ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10111.99999.csv diff --git a/ebusd-configuration-known-slave-address/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/3c.Excellent300.csv deleted file mode 100644 index fe424570..00000000 --- a/ebusd-configuration-known-slave-address/3c.Excellent300.csv +++ /dev/null @@ -1,160 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -*r,Excellent300,,,,3c, -*w,Excellent300,,,,3c, - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-known-slave-address/3c.Sky300.csv b/ebusd-configuration-known-slave-address/3c.Sky300.csv deleted file mode 100644 index 4c965f37..00000000 --- a/ebusd-configuration-known-slave-address/3c.Sky300.csv +++ /dev/null @@ -1,160 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -*r,Sky300,,,,3c, -*w,Sky300,,,,3c, - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-known-slave-address/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/7c.Excellent400.csv deleted file mode 100644 index 8b7d0db6..00000000 --- a/ebusd-configuration-known-slave-address/7c.Excellent400.csv +++ /dev/null @@ -1,160 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -*r,Excellent400,,,,7c, -*w,Excellent400,,,,7c, - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv index accdf45c..7519c9aa 100644 --- a/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/de/3c.Excellent300.csv @@ -12,15 +12,15 @@ *w,Excellent300,,,,3c, ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/de/3c.Sky300.csv b/ebusd-configuration-known-slave-address/de/3c.Sky300.csv index 18de6cff..4293443a 100644 --- a/ebusd-configuration-known-slave-address/de/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/de/3c.Sky300.csv @@ -12,15 +12,15 @@ *w,Sky300,,,,3c, ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv index 465ae5c6..61efcdb2 100644 --- a/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/de/7c.Excellent400.csv @@ -12,15 +12,15 @@ *w,Excellent400,,,,7c, ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv index 5e9d318d..42e140b8 100644 --- a/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/en/3c.Excellent300.csv @@ -14,15 +14,15 @@ *w,Excellent300,,,,3c, ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/en/3c.Sky300.csv b/ebusd-configuration-known-slave-address/en/3c.Sky300.csv index 2067e61f..e625137a 100644 --- a/ebusd-configuration-known-slave-address/en/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/en/3c.Sky300.csv @@ -14,15 +14,15 @@ *w,Sky300,,,,3c, ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv index d578a738..17b93db7 100644 --- a/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/en/7c.Excellent400.csv @@ -14,15 +14,15 @@ *w,Excellent400,,,,7c, ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv index 3ddc77d4..ab9c67c6 100644 --- a/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/es/3c.Excellent300.csv @@ -12,15 +12,15 @@ *w,Excellent300,,,,3c, ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/es/3c.Sky300.csv b/ebusd-configuration-known-slave-address/es/3c.Sky300.csv index b2efa86a..bd19e346 100644 --- a/ebusd-configuration-known-slave-address/es/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/es/3c.Sky300.csv @@ -12,15 +12,15 @@ *w,Sky300,,,,3c, ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv index aa7e2d51..9adbbc8d 100644 --- a/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/es/7c.Excellent400.csv @@ -12,15 +12,15 @@ *w,Excellent400,,,,7c, ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv index 1757d63d..84ea3d1d 100644 --- a/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/fr/3c.Excellent300.csv @@ -12,15 +12,15 @@ *w,Excellent300,,,,3c, ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv b/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv index 90c6ba87..11d02d32 100644 --- a/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/fr/3c.Sky300.csv @@ -12,15 +12,15 @@ *w,Sky300,,,,3c, ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv index acfdb9ff..6f155dca 100644 --- a/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/fr/7c.Excellent400.csv @@ -12,15 +12,15 @@ *w,Excellent400,,,,7c, ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv index 843e217d..791e7434 100644 --- a/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/it/3c.Excellent300.csv @@ -12,15 +12,15 @@ *w,Excellent300,,,,3c, ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/it/3c.Sky300.csv b/ebusd-configuration-known-slave-address/it/3c.Sky300.csv index 1b7bf1ce..1f3fb58d 100644 --- a/ebusd-configuration-known-slave-address/it/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/it/3c.Sky300.csv @@ -12,15 +12,15 @@ *w,Sky300,,,,3c, ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv index 662edc91..49ee91a9 100644 --- a/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/it/7c.Excellent400.csv @@ -12,15 +12,15 @@ *w,Excellent400,,,,7c, ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv index 59612777..c1fef63c 100644 --- a/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/nl/3c.Excellent300.csv @@ -14,15 +14,15 @@ *w,Excellent300,,,,3c, ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv b/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv index 03c16fc4..646896b0 100644 --- a/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/nl/3c.Sky300.csv @@ -14,15 +14,15 @@ *w,Sky300,,,,3c, ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv index e02fd7ce..f8e0aa7f 100644 --- a/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/nl/7c.Excellent400.csv @@ -14,15 +14,15 @@ *w,Excellent400,,,,7c, ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv b/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv index 6d87e8a4..e8388bd5 100644 --- a/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv +++ b/ebusd-configuration-known-slave-address/pl/3c.Excellent300.csv @@ -14,15 +14,15 @@ *w,Excellent300,,,,3c, ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv b/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv index 46620064..e31dae40 100644 --- a/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv +++ b/ebusd-configuration-known-slave-address/pl/3c.Sky300.csv @@ -14,15 +14,15 @@ *w,Sky300,,,,3c, ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv b/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv index 2f07c2d1..db262a8c 100644 --- a/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv +++ b/ebusd-configuration-known-slave-address/pl/7c.Excellent400.csv @@ -14,15 +14,15 @@ *w,Excellent400,,,,7c, ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.csv deleted file mode 100644 index 8ec1f73d..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.csv +++ /dev/null @@ -1,84 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF250 SW version from 1.08.06 to 1.08.08 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF250,,,,[fill_your_slave_address_here], -*w,CWLF250,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.plus.csv deleted file mode 100644 index 3a08f51c..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF250.10806.10808.plus.csv +++ /dev/null @@ -1,110 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF250 SW version from 1.08.06 to 1.08.08 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF250,,,,[fill_your_slave_address_here], -*w,CWLF250,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] diff --git a/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.csv deleted file mode 100644 index 76d100e3..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF250 SW version from 1.08.09 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF250,,,,[fill_your_slave_address_here], -*w,CWLF250,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.plus.csv deleted file mode 100644 index 2a4ca465..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF250.10809.99999.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF250 SW version from 1.08.09 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF250,,,,[fill_your_slave_address_here], -*w,CWLF250,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] diff --git a/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.csv deleted file mode 100644 index 7d04396c..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.csv +++ /dev/null @@ -1,84 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF350 SW version from 1.08.06 to 1.08.08 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF350,,,,[fill_your_slave_address_here], -*w,CWLF350,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.plus.csv deleted file mode 100644 index d923f414..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF350.10806.10808.plus.csv +++ /dev/null @@ -1,110 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF350 SW version from 1.08.06 to 1.08.08 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF350,,,,[fill_your_slave_address_here], -*w,CWLF350,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] diff --git a/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.csv deleted file mode 100644 index d3fb27af..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF350 SW version from 1.08.09 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF350,,,,[fill_your_slave_address_here], -*w,CWLF350,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.plus.csv deleted file mode 100644 index da126d68..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLF350.10809.99999.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLF350 SW version from 1.08.09 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLF350,,,,[fill_your_slave_address_here], -*w,CWLF350,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.csv deleted file mode 100644 index 96b6b755..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.csv +++ /dev/null @@ -1,122 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.plus.csv deleted file mode 100644 index 96b6b755..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10603.10603.plus.csv +++ /dev/null @@ -1,122 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.csv deleted file mode 100644 index a539912e..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.csv +++ /dev/null @@ -1,148 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.plus.csv deleted file mode 100644 index a539912e..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10604.10605.plus.csv +++ /dev/null @@ -1,148 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.csv deleted file mode 100644 index 9f38552c..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.csv +++ /dev/null @@ -1,150 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.plus.csv deleted file mode 100644 index 9f38552c..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10606.10607.plus.csv +++ /dev/null @@ -1,150 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.csv deleted file mode 100644 index bd00373d..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.plus.csv deleted file mode 100644 index bd00373d..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10608.10706.plus.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.csv deleted file mode 100644 index 6c6a0072..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.plus.csv deleted file mode 100644 index 808527bd..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10801.10805.plus.csv +++ /dev/null @@ -1,160 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.csv deleted file mode 100644 index 3f2d5018..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.plus.csv deleted file mode 100644 index 381aceec..00000000 --- a/ebusd-configuration-unknown-slave-address/CWLTower300.10806.99999.plus.csv +++ /dev/null @@ -1,162 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for CWLTower300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,CWLTower300,,,,[fill_your_slave_address_here], -*w,CWLTower300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:4;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:4],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.csv deleted file mode 100644 index 5036ea69..00000000 --- a/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.csv +++ /dev/null @@ -1,85 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for ConstantRPM400 SW version from 1.05.05 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,ConstantRPM400,,,,[fill_your_slave_address_here], -*w,ConstantRPM400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,01,,,SIR,,%,[min:15;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,02,,,SIR,,%,[min:15;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,03,,,SIR,,%,[min:15;max:100;step:1;default:48] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:48] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,04,,,SIR,,%,[min:15;max:100;step:1;default:48] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:48] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,05,,,SIR,,%,[min:15;max:100;step:1;default:68] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:68] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,06,,,SIR,,%,[min:15;max:100;step:1;default:68] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:68] -w,,TemperaturaByPassu,BypassTemp,,,4080,07,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,2e,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,2e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,08,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,08,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.plus.csv deleted file mode 100644 index 5036ea69..00000000 --- a/ebusd-configuration-unknown-slave-address/ConstantRPM400.10505.99999.plus.csv +++ /dev/null @@ -1,85 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for ConstantRPM400 SW version from 1.05.05 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,ConstantRPM400,,,,[fill_your_slave_address_here], -*w,ConstantRPM400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,01,,,SIR,,%,[min:15;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,02,,,SIR,,%,[min:15;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,03,,,SIR,,%,[min:15;max:100;step:1;default:48] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:48] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,04,,,SIR,,%,[min:15;max:100;step:1;default:48] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:48] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,05,,,SIR,,%,[min:15;max:100;step:1;default:68] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:68] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,06,,,SIR,,%,[min:15;max:100;step:1;default:68] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:15],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:68] -w,,TemperaturaByPassu,BypassTemp,,,4080,07,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,2e,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,2e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,08,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,08,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.csv deleted file mode 100644 index cb78991c..00000000 --- a/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.csv +++ /dev/null @@ -1,98 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for DecentralAir70 SW version from 1.01.01 to 1.07.00 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,DecentralAir70,,,,[fill_your_slave_address_here], -*w,DecentralAir70,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,WersjaOprogramowaniaDodatkowego,PlusSoftwareVersion,,,4022,f0,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Off;1=Preset_01;1=Preset_01;2=Preset_02;3=Preset_03;4=Preset_04;5=Preset_05;240=AutoMode,, -r,,PrędkośćWentylatora,SpeedFan,,,4022,02,,,UIR,,rpm, -r,,Mikroprzełącznik,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,TemperatureInside,,,4022,07,,,SIR,10,°C, -r,,TempZewn,TemperatureOutside,,,4022,08,,,SIR,10,°C, -r,,NastawaPrzepływu,FlowSetpoint,,,4022,09,,,UIR,,m³/h, -r,,PrzepływRzeczywisty,FlowActualValue,,,4022,0b,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusZasilaniaEBus,EBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,NaciśniętyPrzycisk,UIFButtons,,,4022,19,,,UIR,,, -r,,StykZewnętrzny,ExternalContact1,,,4022,1b,,,UIR,0=Off;1=On,, -r,,RelativeHumidity,RHSensorValue,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityControlStatus,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatora,PWMFan,,,4022,24,,,UIR,,, -r,,StatusCzujnikaCO2,CO2SensorStatus,,,4022,38,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,WartośćCzujnikaCO2,CO2SensorValue,,,4022,39,,,UIR,,ppm, -r,,StatusWentylatorów,FanStatus,,,4022,3a,,,UIR,0=Off;1=On;2=Blocked;255=Error,, -r,,ZużycieFiltraDni,FilterUsedInDays,,,4022,3c,,,UIR,,Days, -r,,ZużycieFiltra1000m3,FilterUsedIn1000M3,,,4022,3d,,,UIR,-1000,m³, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,-1000,m³, -r,,ZużycieFiltra,FilterUsedInM3,,,4022,85,,,ULR,,m³, -r,,PrzepływCałkowity,TotalFlowInM3,,,4022,84,,,ULR,,m³, -r,,WykrywanieKołpaka,CapDetection,,,4022,42,,,UIR,0=Off;1=On,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,ULR,,, -r,,StatusSystemu,SystemStatus,,,4022,41,,,UIR,0=PowerUp;1=Off;2=TemporaryOff;3=Normal;4=CoolingDown;5=FrostMode;6=FrostModeReduced;7=FanOff;100=TestMode,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,BłędyZłączaEBus,EBusSyncGenErrors,,,4022,64,,,UIR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4080,50,,,UIR,,,[min:0;max:5;step:1;default:3] -r,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4050,50,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:5],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4080,51,,,UIR,,m³/h,[min:15;max:70;step:1;default:15] -r,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4050,51,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:15] -w,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4080,52,,,UIR,,m³/h,[min:15;max:70;step:1;default:25] -r,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4050,52,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:25] -w,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4080,53,,,UIR,,m³/h,[min:15;max:70;step:1;default:40] -r,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4050,53,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:40] -w,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4080,54,,,UIR,,m³/h,[min:15;max:70;step:1;default:55] -r,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4050,54,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:55] -w,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4080,55,,,UIR,,m³/h,[min:15;max:70;step:1;default:70] -r,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4050,55,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:70] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4080,1c,,,UIR,,m³/h,[min:0;max:2000;step:1;default:86] -r,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4050,1c,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:2000],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:86] -w,,JasnośćLED,LedIntensity,,,4080,1d,,,UIR,,%,[min:20;max:100;step:1;default:100] -r,,JasnośćLED,LedIntensity,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:20],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4080,48,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4050,48,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4080,49,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4050,49,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,WyjścieOświetlenia,LightOutput,,,4080,56,,,UIR,,%,[min:0;max:100;step:1;default:0] -r,,WyjścieOświetlenia,LightOutput,,,4050,56,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.plus.csv deleted file mode 100644 index 686d7976..00000000 --- a/ebusd-configuration-unknown-slave-address/DecentralAir70.10101.10700.plus.csv +++ /dev/null @@ -1,112 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for DecentralAir70 SW version from 1.01.01 to 1.07.00 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,DecentralAir70,,,,[fill_your_slave_address_here], -*w,DecentralAir70,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,WersjaOprogramowaniaDodatkowego,PlusSoftwareVersion,,,4022,f0,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Off;1=Preset_01;1=Preset_01;2=Preset_02;3=Preset_03;4=Preset_04;5=Preset_05;240=AutoMode,, -r,,PrędkośćWentylatora,SpeedFan,,,4022,02,,,UIR,,rpm, -r,,Mikroprzełącznik,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,TemperatureInside,,,4022,07,,,SIR,10,°C, -r,,TempZewn,TemperatureOutside,,,4022,08,,,SIR,10,°C, -r,,NastawaPrzepływu,FlowSetpoint,,,4022,09,,,UIR,,m³/h, -r,,PrzepływRzeczywisty,FlowActualValue,,,4022,0b,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusZasilaniaEBus,EBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,NaciśniętyPrzycisk,UIFButtons,,,4022,19,,,UIR,,, -r,,StykZewnętrzny,ExternalContact1,,,4022,1b,,,UIR,0=Off;1=On,, -r,,RelativeHumidity,RHSensorValue,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityControlStatus,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatora,PWMFan,,,4022,24,,,UIR,,, -r,,StatusCzujnikaCO2,CO2SensorStatus,,,4022,38,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,WartośćCzujnikaCO2,CO2SensorValue,,,4022,39,,,UIR,,ppm, -r,,StatusWentylatorów,FanStatus,,,4022,3a,,,UIR,0=Off;1=On;2=Blocked;255=Error,, -r,,ZużycieFiltraDni,FilterUsedInDays,,,4022,3c,,,UIR,,Days, -r,,ZużycieFiltra1000m3,FilterUsedIn1000M3,,,4022,3d,,,UIR,-1000,m³, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,-1000,m³, -r,,ZużycieFiltra,FilterUsedInM3,,,4022,85,,,ULR,,m³, -r,,PrzepływCałkowity,TotalFlowInM3,,,4022,84,,,ULR,,m³, -r,,WykrywanieKołpaka,CapDetection,,,4022,42,,,UIR,0=Off;1=On,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,ULR,,, -r,,StatusSystemu,SystemStatus,,,4022,41,,,UIR,0=PowerUp;1=Off;2=TemporaryOff;3=Normal;4=CoolingDown;5=FrostMode;6=FrostModeReduced;7=FanOff;100=TestMode,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,BłędyZłączaEBus,EBusSyncGenErrors,,,4022,64,,,UIR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4080,50,,,UIR,,,[min:0;max:5;step:1;default:3] -r,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4050,50,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:5],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4080,51,,,UIR,,m³/h,[min:15;max:70;step:1;default:15] -r,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4050,51,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:15] -w,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4080,52,,,UIR,,m³/h,[min:15;max:70;step:1;default:25] -r,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4050,52,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:25] -w,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4080,53,,,UIR,,m³/h,[min:15;max:70;step:1;default:40] -r,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4050,53,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:40] -w,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4080,54,,,UIR,,m³/h,[min:15;max:70;step:1;default:55] -r,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4050,54,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:55] -w,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4080,55,,,UIR,,m³/h,[min:15;max:70;step:1;default:70] -r,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4050,55,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:70] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4080,1c,,,UIR,,m³/h,[min:0;max:2000;step:1;default:86] -r,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4050,1c,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:2000],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:86] -w,,JasnośćLED,LedIntensity,,,4080,1d,,,UIR,,%,[min:20;max:100;step:1;default:100] -r,,JasnośćLED,LedIntensity,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:20],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4080,48,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4050,48,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4080,49,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4050,49,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,WyjścieOświetlenia,LightOutput,,,4080,56,,,UIR,,%,[min:0;max:100;step:1;default:0] -r,,WyjścieOświetlenia,LightOutput,,,4050,56,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:0] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,44,,,SIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,44,,,SIR,,,,Min,,SIR,,,[min:1],Max,,SIR,,,[max:247],Step,,SIR,,,[step:1],Default,,SIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,45,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,45,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,46,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,46,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,47,,,UIR,,,[min:0;max:1;step:1;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,47,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,StrojeniePrzepływu,FlowTuning,,,4080,3d,,,UIR,,%,[min:75;max:125;step:1;default:100] -r,,StrojeniePrzepływu,FlowTuning,,,4050,3d,,,UIR,,%,,Min,,UIR,,%,[min:75],Max,,UIR,,%,[max:125],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:8] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:8] diff --git a/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.csv deleted file mode 100644 index 75a8d9df..00000000 --- a/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.csv +++ /dev/null @@ -1,98 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for DecentralAir70 SW version from 1.07.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,DecentralAir70,,,,[fill_your_slave_address_here], -*w,DecentralAir70,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,WersjaOprogramowaniaDodatkowego,PlusSoftwareVersion,,,4022,f0,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Preset_01;1=Preset_02;2=Preset_03;3=Preset_04;4=Preset_05;240=AutoMode;254=Off,, -r,,PrędkośćWentylatora,SpeedFan,,,4022,02,,,UIR,,rpm, -r,,Mikroprzełącznik,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,TemperatureInside,,,4022,07,,,SIR,10,°C, -r,,TempZewn,TemperatureOutside,,,4022,08,,,SIR,10,°C, -r,,NastawaPrzepływu,FlowSetpoint,,,4022,09,,,UIR,,m³/h, -r,,PrzepływRzeczywisty,FlowActualValue,,,4022,0b,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusZasilaniaEBus,EBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,NaciśniętyPrzycisk,UIFButtons,,,4022,19,,,UIR,,, -r,,StykZewnętrzny,ExternalContact1,,,4022,1b,,,UIR,0=Off;1=On,, -r,,RelativeHumidity,RHSensorValue,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityControlStatus,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatora,PWMFan,,,4022,24,,,UIR,,, -r,,StatusCzujnikaCO2,CO2SensorStatus,,,4022,38,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,WartośćCzujnikaCO2,CO2SensorValue,,,4022,39,,,UIR,,ppm, -r,,StatusWentylatorów,FanStatus,,,4022,3a,,,UIR,0=Off;1=On;2=Blocked;255=Error,, -r,,ZużycieFiltraDni,FilterUsedInDays,,,4022,3c,,,UIR,,Days, -r,,ZużycieFiltra1000m3,FilterUsedIn1000M3,,,4022,3d,,,UIR,-1000,m³, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,-1000,m³, -r,,ZużycieFiltra,FilterUsedInM3,,,4022,85,,,ULR,,m³, -r,,PrzepływCałkowity,TotalFlowInM3,,,4022,84,,,ULR,,m³, -r,,WykrywanieKołpaka,CapDetection,,,4022,42,,,UIR,0=Off;1=On,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,ULR,,, -r,,StatusSystemu,SystemStatus,,,4022,41,,,UIR,0=PowerUp;1=Off;2=TemporaryOff;3=Normal;4=CoolingDown;5=FrostMode;6=FrostModeReduced;7=FanOff;8=SelfTestMode;9=TestMode,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,BłędyZłączaEBus,EBusSyncGenErrors,,,4022,64,,,UIR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4080,50,,,UIR,,,[min:0;max:5;step:1;default:3] -r,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4050,50,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:5],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4080,51,,,UIR,,m³/h,[min:15;max:70;step:1;default:15] -r,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4050,51,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:15] -w,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4080,52,,,UIR,,m³/h,[min:15;max:70;step:1;default:25] -r,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4050,52,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:25] -w,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4080,53,,,UIR,,m³/h,[min:15;max:70;step:1;default:40] -r,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4050,53,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:40] -w,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4080,54,,,UIR,,m³/h,[min:15;max:70;step:1;default:55] -r,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4050,54,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:55] -w,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4080,55,,,UIR,,m³/h,[min:15;max:70;step:1;default:70] -r,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4050,55,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:70] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4080,1c,,,UIR,,m³/h,[min:0;max:2000;step:1;default:86] -r,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4050,1c,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:2000],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:86] -w,,JasnośćLED,LedIntensity,,,4080,1d,,,UIR,,%,[min:20;max:100;step:1;default:100] -r,,JasnośćLED,LedIntensity,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:20],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4080,48,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4050,48,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4080,49,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4050,49,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,WyjścieOświetlenia,LightOutput,,,4080,56,,,UIR,,%,[min:0;max:100;step:1;default:0] -r,,WyjścieOświetlenia,LightOutput,,,4050,56,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.plus.csv deleted file mode 100644 index 7f589e55..00000000 --- a/ebusd-configuration-unknown-slave-address/DecentralAir70.10701.99999.plus.csv +++ /dev/null @@ -1,112 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for DecentralAir70 SW version from 1.07.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,DecentralAir70,,,,[fill_your_slave_address_here], -*w,DecentralAir70,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,WersjaOprogramowaniaDodatkowego,PlusSoftwareVersion,,,4022,f0,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Preset_01;1=Preset_02;2=Preset_03;3=Preset_04;4=Preset_05;240=AutoMode;254=Off,, -r,,PrędkośćWentylatora,SpeedFan,,,4022,02,,,UIR,,rpm, -r,,Mikroprzełącznik,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,TemperatureInside,,,4022,07,,,SIR,10,°C, -r,,TempZewn,TemperatureOutside,,,4022,08,,,SIR,10,°C, -r,,NastawaPrzepływu,FlowSetpoint,,,4022,09,,,UIR,,m³/h, -r,,PrzepływRzeczywisty,FlowActualValue,,,4022,0b,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusZasilaniaEBus,EBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,NaciśniętyPrzycisk,UIFButtons,,,4022,19,,,UIR,,, -r,,StykZewnętrzny,ExternalContact1,,,4022,1b,,,UIR,0=Off;1=On,, -r,,RelativeHumidity,RHSensorValue,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityControlStatus,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatora,PWMFan,,,4022,24,,,UIR,,, -r,,StatusCzujnikaCO2,CO2SensorStatus,,,4022,38,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,WartośćCzujnikaCO2,CO2SensorValue,,,4022,39,,,UIR,,ppm, -r,,StatusWentylatorów,FanStatus,,,4022,3a,,,UIR,0=Off;1=On;2=Blocked;255=Error,, -r,,ZużycieFiltraDni,FilterUsedInDays,,,4022,3c,,,UIR,,Days, -r,,ZużycieFiltra1000m3,FilterUsedIn1000M3,,,4022,3d,,,UIR,-1000,m³, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,-1000,m³, -r,,ZużycieFiltra,FilterUsedInM3,,,4022,85,,,ULR,,m³, -r,,PrzepływCałkowity,TotalFlowInM3,,,4022,84,,,ULR,,m³, -r,,WykrywanieKołpaka,CapDetection,,,4022,42,,,UIR,0=Off;1=On,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,ULR,,, -r,,StatusSystemu,SystemStatus,,,4022,41,,,UIR,0=PowerUp;1=Off;2=TemporaryOff;3=Normal;4=CoolingDown;5=FrostMode;6=FrostModeReduced;7=FanOff;8=SelfTestMode;9=TestMode,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,BłędyZłączaEBus,EBusSyncGenErrors,,,4022,64,,,UIR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4080,50,,,UIR,,,[min:0;max:5;step:1;default:3] -r,,OstatniaWartośćUstawieniaWstępnegoPrzepływu,LastFlowPresetValue,,,4050,50,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:5],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4080,51,,,UIR,,m³/h,[min:15;max:70;step:1;default:15] -r,,UstawienieWstępnePrzepływu01,FlowPreset01,,,4050,51,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:15] -w,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4080,52,,,UIR,,m³/h,[min:15;max:70;step:1;default:25] -r,,UstawienieWstępnePrzepływu02,FlowPreset02,,,4050,52,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:25] -w,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4080,53,,,UIR,,m³/h,[min:15;max:70;step:1;default:40] -r,,UstawienieWstępnePrzepływu03,FlowPreset03,,,4050,53,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:40] -w,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4080,54,,,UIR,,m³/h,[min:15;max:70;step:1;default:55] -r,,UstawienieWstępnePrzepływu04,FlowPreset04,,,4050,54,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:55] -w,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4080,55,,,UIR,,m³/h,[min:15;max:70;step:1;default:70] -r,,UstawienieWstępnePrzepływu05,FlowPreset05,,,4050,55,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:15],Max,,UIR,,m³/h,[max:70],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:70] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4080,1c,,,UIR,,m³/h,[min:0;max:2000;step:1;default:86] -r,,PrzepływMaksymalnyFiltra,FilterMaximumFlow,,,4050,1c,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:2000],Step,,UIR,,m³/h,[step:1],Default,,UIR,,m³/h,[default:86] -w,,JasnośćLED,LedIntensity,,,4080,1d,,,UIR,,%,[min:20;max:100;step:1;default:100] -r,,JasnośćLED,LedIntensity,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:20],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4080,48,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,NiskiPoziomCzujnikaCO2,CO2SensorLowLevel,,,4050,48,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4080,49,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,WysokiPoziomCzujnikaCO2,CO2SensorHighLevel,,,4050,49,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,WyjścieOświetlenia,LightOutput,,,4080,56,,,UIR,,%,[min:0;max:100;step:1;default:0] -r,,WyjścieOświetlenia,LightOutput,,,4050,56,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:0] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,44,,,SIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,44,,,SIR,,,,Min,,SIR,,,[min:1],Max,,SIR,,,[max:247],Step,,SIR,,,[step:1],Default,,SIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,45,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,45,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,46,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,46,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,47,,,UIR,,,[min:0;max:1;step:1;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,47,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,StrojeniePrzepływu,FlowTuning,,,4080,3d,,,UIR,,%,[min:75;max:125;step:1;default:100] -r,,StrojeniePrzepływu,FlowTuning,,,4050,3d,,,UIR,,%,,Min,,UIR,,%,[min:75],Max,,UIR,,%,[max:125],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:8] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:8] diff --git a/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.csv deleted file mode 100644 index 5ffb1c87..00000000 --- a/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.csv +++ /dev/null @@ -1,86 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Elan10 SW version from 1.01.03 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Elan10,,,,[fill_your_slave_address_here], -*w,Elan10,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, -r,,NastawaWentylatora,FanSetpoint,,,4022,09,,,UIR,,%, -r,,PrędkośćWentylatora,FanRPMSpeed,,,4022,02,,,UIR,,rpm, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UCH,0=NotInitialized;1=Initializing;2=Stopped;3=Running;4=Error,, -r,,StatusFiltra,DirtyFilterState,,,4022,18,,,UCH,0=Clean;1=Dirty,, -r,,PozostałeDniEksploatacjiFiltra,FilterDaysLeft,,,4022,26,,,UIR,,, -r,,TemperaturaWylotowa,ExhaustTemperature,,,4022,07,,,SIR,10,°C, -r,,TemperaturaWężownicy,CoilTemperature,,,4022,08,,,SIR,10,°C, -r,,TemperaturaWejściowa,InputCooling,,,4022,1b,,,UCH,0=Off;1=On,, -r,,BłądWejścia,InputError,,,4022,1c,,,UCH,0=Off;1=On,, -r,,ChłodzenieWyjścia,OutputCooling,,,4022,24,,,UCH,0=Off;1=On,, -r,,ZabezpieczenieWyjściaPrzedMrozem,OutputFrostProtection,,,4022,25,,,UCH,0=Off;1=On,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,03,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaEBus,EBusSwitchPosition,,,4022,04,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaAktywności,ActiveSwitchPosition,,,4022,06,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,StatusMrozu,FrostState,,,4022,16,,,UCH,0=NoFrost;1=FrostLevel_1;2=FrostLevel_2,, -r,,StatusZasilaniaEBus,EBusPowerState,,,4022,17,,,UCH,0=Off;1=On,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,Mikroprzełącznik,Dipswitch,,,4022,10,,,UCH,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4080,01,,,UIR,,%,[min:10;max:100;step:1;default:20] -r,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4050,01,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:20] -w,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4080,02,,,UIR,,%,[min:10;max:100;step:1;default:65] -r,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4050,02,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:65] -w,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4080,03,,,UIR,,%,[min:10;max:100;step:1;default:80] -r,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4050,03,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:80] -w,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4080,04,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4080,05,,,SIR,10,°C,[min:0;max:1000;step:5;default:600] -r,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:600] -w,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4080,06,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4050,06,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4080,07,,,SIR,10,°C,[min:0;max:1000;step:5;default:250] -r,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4080,08,,,SIR,10,°C,[min:0;max:50;step:1;default:10] -r,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4050,08,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:10] -w,,ProgramWentylacji,VentilationProgram,,,4080,09,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ProgramWentylacji,VentilationProgram,,,4050,09,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4080,0a,,,SIR,10,°C,[min:-200;max:300;step:5;default:50] -r,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4080,0b,,,SIR,10,°C,[min:-200;max:300;step:5;default:0] -r,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:0] -w,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4080,0c,,,SIR,10,°C,[min:0;max:50;step:1;default:20] -r,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4050,0c,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:20] -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:1] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,d3,,,UIR,,%,[min:0;max:100;step:5;default:70] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,d3,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:70] -w,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4080,d2,,,UIR,,Minutes,[min:0;max:60;step:1;default:15] -r,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4050,d2,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:15] diff --git a/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.plus.csv deleted file mode 100644 index 5ffb1c87..00000000 --- a/ebusd-configuration-unknown-slave-address/Elan10.10103.99999.plus.csv +++ /dev/null @@ -1,86 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Elan10 SW version from 1.01.03 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Elan10,,,,[fill_your_slave_address_here], -*w,Elan10,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, -r,,NastawaWentylatora,FanSetpoint,,,4022,09,,,UIR,,%, -r,,PrędkośćWentylatora,FanRPMSpeed,,,4022,02,,,UIR,,rpm, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UCH,0=NotInitialized;1=Initializing;2=Stopped;3=Running;4=Error,, -r,,StatusFiltra,DirtyFilterState,,,4022,18,,,UCH,0=Clean;1=Dirty,, -r,,PozostałeDniEksploatacjiFiltra,FilterDaysLeft,,,4022,26,,,UIR,,, -r,,TemperaturaWylotowa,ExhaustTemperature,,,4022,07,,,SIR,10,°C, -r,,TemperaturaWężownicy,CoilTemperature,,,4022,08,,,SIR,10,°C, -r,,TemperaturaWejściowa,InputCooling,,,4022,1b,,,UCH,0=Off;1=On,, -r,,BłądWejścia,InputError,,,4022,1c,,,UCH,0=Off;1=On,, -r,,ChłodzenieWyjścia,OutputCooling,,,4022,24,,,UCH,0=Off;1=On,, -r,,ZabezpieczenieWyjściaPrzedMrozem,OutputFrostProtection,,,4022,25,,,UCH,0=Off;1=On,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,03,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaEBus,EBusSwitchPosition,,,4022,04,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaAktywności,ActiveSwitchPosition,,,4022,06,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,StatusMrozu,FrostState,,,4022,16,,,UCH,0=NoFrost;1=FrostLevel_1;2=FrostLevel_2,, -r,,StatusZasilaniaEBus,EBusPowerState,,,4022,17,,,UCH,0=Off;1=On,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,Mikroprzełącznik,Dipswitch,,,4022,10,,,UCH,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4080,01,,,UIR,,%,[min:10;max:100;step:1;default:20] -r,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4050,01,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:20] -w,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4080,02,,,UIR,,%,[min:10;max:100;step:1;default:65] -r,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4050,02,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:65] -w,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4080,03,,,UIR,,%,[min:10;max:100;step:1;default:80] -r,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4050,03,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:80] -w,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4080,04,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4080,05,,,SIR,10,°C,[min:0;max:1000;step:5;default:600] -r,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:600] -w,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4080,06,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4050,06,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4080,07,,,SIR,10,°C,[min:0;max:1000;step:5;default:250] -r,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4080,08,,,SIR,10,°C,[min:0;max:50;step:1;default:10] -r,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4050,08,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:10] -w,,ProgramWentylacji,VentilationProgram,,,4080,09,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ProgramWentylacji,VentilationProgram,,,4050,09,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4080,0a,,,SIR,10,°C,[min:-200;max:300;step:5;default:50] -r,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4080,0b,,,SIR,10,°C,[min:-200;max:300;step:5;default:0] -r,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:0] -w,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4080,0c,,,SIR,10,°C,[min:0;max:50;step:1;default:20] -r,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4050,0c,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:20] -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:1] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,d3,,,UIR,,%,[min:0;max:100;step:5;default:70] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,d3,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:70] -w,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4080,d2,,,UIR,,Minutes,[min:0;max:60;step:1;default:15] -r,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4050,d2,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:15] diff --git a/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.csv deleted file mode 100644 index 351c04db..00000000 --- a/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.csv +++ /dev/null @@ -1,112 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Elan4 SW version from 1.01.04 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Elan4,,,,[fill_your_slave_address_here], -*w,Elan4,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, -r,,NastawaWentylatora,FanSetpoint,,,4022,09,,,UIR,,%, -r,,PrędkośćWentylatora,FanRPMSpeed,,,4022,02,,,UIR,,rpm, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UCH,0=NotInitialized;1=Initializing;2=Stopped;3=Running;4=Error,, -r,,StatusFiltra,DirtyFilterState,,,4022,18,,,UCH,0=Clean;1=Dirty,, -r,,PozostałeDniEksploatacjiFiltra,FilterDaysLeft,,,4022,26,,,UIR,,, -r,,TemperaturaWylotowa,ExhaustTemperature,,,4022,07,,,SIR,10,°C, -r,,TemperaturaWężownicy,CoilTemperature,,,4022,08,,,SIR,10,°C, -r,,TemperaturaWejściowa,InputCooling,,,4022,1b,,,UCH,0=Off;1=On,, -r,,BłądWejścia,InputError,,,4022,1c,,,UCH,0=Off;1=On,, -r,,ChłodzenieWyjścia,OutputCooling,,,4022,24,,,UCH,0=Off;1=On,, -r,,ZabezpieczenieWyjściaPrzedMrozem,OutputFrostProtection,,,4022,25,,,UCH,0=Off;1=On,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,03,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaEBus,EBusSwitchPosition,,,4022,04,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaAktywności,ActiveSwitchPosition,,,4022,06,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,StatusMrozu,FrostState,,,4022,16,,,UCH,0=NoFrost;1=FrostLevel_1;2=FrostLevel_2,, -r,,StatusZasilaniaEBus,EBusPowerState,,,4022,17,,,UCH,0=Off;1=On,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,Mikroprzełącznik,Dipswitch,,,4022,10,,,UCH,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4080,01,,,UIR,,%,[min:10;max:100;step:1;default:20] -r,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4050,01,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:20] -w,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4080,02,,,UIR,,%,[min:10;max:100;step:1;default:65] -r,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4050,02,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:65] -w,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4080,03,,,UIR,,%,[min:10;max:100;step:1;default:80] -r,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4050,03,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:80] -w,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4080,04,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4080,05,,,SIR,10,°C,[min:0;max:1000;step:5;default:600] -r,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:600] -w,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4080,06,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4050,06,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4080,07,,,SIR,10,°C,[min:0;max:1000;step:5;default:250] -r,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4080,08,,,SIR,10,°C,[min:0;max:50;step:1;default:10] -r,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4050,08,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:10] -w,,ProgramWentylacji,VentilationProgram,,,4080,09,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,ProgramWentylacji,VentilationProgram,,,4050,09,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4080,0a,,,SIR,10,°C,[min:-200;max:300;step:5;default:50] -r,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4080,0b,,,SIR,10,°C,[min:-200;max:300;step:5;default:0] -r,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:0] -w,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4080,0c,,,SIR,10,°C,[min:0;max:50;step:1;default:20] -r,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4050,0c,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:20] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,AdresCzujnika1CO2,CO2Sensor1Address,,,4080,61,,,UIR,,,[min:0;max:30;step:1;default:4] -r,,AdresCzujnika1CO2,CO2Sensor1Address,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:4] -w,,AdresCzujnika2CO2,CO2Sensor2Address,,,4080,62,,,UIR,,,[min:0;max:30;step:1;default:5] -r,,AdresCzujnika2CO2,CO2Sensor2Address,,,4050,62,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,AdresCzujnika3CO2,CO2Sensor3Address,,,4080,63,,,UIR,,,[min:0;max:30;step:1;default:6] -r,,AdresCzujnika3CO2,CO2Sensor3Address,,,4050,63,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:6] -w,,AdresCzujnika4CO2,CO2Sensor4Address,,,4080,64,,,UIR,,,[min:0;max:30;step:1;default:7] -r,,AdresCzujnika4CO2,CO2Sensor4Address,,,4050,64,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:7] diff --git a/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.plus.csv deleted file mode 100644 index 5743c784..00000000 --- a/ebusd-configuration-unknown-slave-address/Elan4.10104.99999.plus.csv +++ /dev/null @@ -1,122 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Elan4 SW version from 1.01.04 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Elan4,,,,[fill_your_slave_address_here], -*w,Elan4,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, -r,,NastawaWentylatora,FanSetpoint,,,4022,09,,,UIR,,%, -r,,PrędkośćWentylatora,FanRPMSpeed,,,4022,02,,,UIR,,rpm, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UCH,0=NotInitialized;1=Initializing;2=Stopped;3=Running;4=Error,, -r,,StatusFiltra,DirtyFilterState,,,4022,18,,,UCH,0=Clean;1=Dirty,, -r,,PozostałeDniEksploatacjiFiltra,FilterDaysLeft,,,4022,26,,,UIR,,, -r,,TemperaturaWylotowa,ExhaustTemperature,,,4022,07,,,SIR,10,°C, -r,,TemperaturaWężownicy,CoilTemperature,,,4022,08,,,SIR,10,°C, -r,,TemperaturaWejściowa,InputCooling,,,4022,1b,,,UCH,0=Off;1=On,, -r,,BłądWejścia,InputError,,,4022,1c,,,UCH,0=Off;1=On,, -r,,ChłodzenieWyjścia,OutputCooling,,,4022,24,,,UCH,0=Off;1=On,, -r,,ZabezpieczenieWyjściaPrzedMrozem,OutputFrostProtection,,,4022,25,,,UCH,0=Off;1=On,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,03,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaEBus,EBusSwitchPosition,,,4022,04,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PozycjaŁącznikaAktywności,ActiveSwitchPosition,,,4022,06,,,UCH,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,StatusMrozu,FrostState,,,4022,16,,,UCH,0=NoFrost;1=FrostLevel_1;2=FrostLevel_2,, -r,,StatusZasilaniaEBus,EBusPowerState,,,4022,17,,,UCH,0=Off;1=On,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,Mikroprzełącznik,Dipswitch,,,4022,10,,,UCH,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hours, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4080,01,,,UIR,,%,[min:10;max:100;step:1;default:20] -r,,MinimumSterowaniaPrzepływem,ControlFlowMinimum,,,4050,01,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:20] -w,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4080,02,,,UIR,,%,[min:10;max:100;step:1;default:65] -r,,MaksimumSterowaniaPrzepływem,ControlFlowMaximum,,,4050,02,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:65] -w,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4080,03,,,UIR,,%,[min:10;max:100;step:1;default:80] -r,,ChłodzenieSterowaniaPrzepływem,ControlFlowCooling,,,4050,03,,,UIR,,%,,Min,,UIR,,%,[min:10],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:80] -w,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4080,04,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaPoczątkowaSterowania,ControlStartTemp10,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4080,05,,,SIR,10,°C,[min:0;max:1000;step:5;default:600] -r,,TemperaturaKońcowaSterowania,ControlEndTemp10,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:600] -w,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4080,06,,,SIR,10,°C,[min:0;max:1000;step:5;default:300] -r,,TemperaturaUruchomieniaWentylatora,FanStartTemp10,,,4050,06,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:300] -w,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4080,07,,,SIR,10,°C,[min:0;max:1000;step:5;default:250] -r,,TemperaturaWyłączeniaWentylatora,FanOffTemp10,,,4050,07,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:1000],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4080,08,,,SIR,10,°C,[min:0;max:50;step:1;default:10] -r,,HisterezaTemperaturyUruchomieniaWentylatora,FanStartTempHyst10,,,4050,08,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:10] -w,,ProgramWentylacji,VentilationProgram,,,4080,09,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,ProgramWentylacji,VentilationProgram,,,4050,09,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4080,0a,,,SIR,10,°C,[min:-200;max:300;step:5;default:50] -r,,Temperatura1LimituMrozowego,FrostLimitOneTemp10,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4080,0b,,,SIR,10,°C,[min:-200;max:300;step:5;default:0] -r,,Temperatura2LimituMrozowego,FrostLimitTwoTemp10,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-200],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:0] -w,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4080,0c,,,SIR,10,°C,[min:0;max:50;step:1;default:20] -r,,HisterezaTemperaturyMrozu,FrostTempHyst10,,,4050,0c,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:20] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,AdresCzujnika1CO2,CO2Sensor1Address,,,4080,61,,,UIR,,,[min:0;max:30;step:1;default:4] -r,,AdresCzujnika1CO2,CO2Sensor1Address,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:4] -w,,AdresCzujnika2CO2,CO2Sensor2Address,,,4080,62,,,UIR,,,[min:0;max:30;step:1;default:5] -r,,AdresCzujnika2CO2,CO2Sensor2Address,,,4050,62,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,AdresCzujnika3CO2,CO2Sensor3Address,,,4080,63,,,UIR,,,[min:0;max:30;step:1;default:6] -r,,AdresCzujnika3CO2,CO2Sensor3Address,,,4050,63,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:6] -w,,AdresCzujnika4CO2,CO2Sensor4Address,,,4080,64,,,UIR,,,[min:0;max:30;step:1;default:7] -r,,AdresCzujnika4CO2,CO2Sensor4Address,,,4050,64,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:30],Step,,UIR,,,[step:1],Default,,UIR,,,[default:7] -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:1] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,GrupaAdresówPodłączonychWTW,MasterWTWeBusGroup,,,4080,70,,,UIR,,,[min:1;max:8;step:1;default:7] -r,,GrupaAdresówPodłączonychWTW,MasterWTWeBusGroup,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:7] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,PoziomPodświetlenia,BacklightLevel,,,4080,d3,,,UIR,,%,[min:0;max:100;step:5;default:70] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,d3,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:70] -w,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4080,d2,,,UIR,,Minutes,[min:0;max:60;step:1;default:15] -r,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4050,d2,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:15] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.csv deleted file mode 100644 index 15c9d52e..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.csv +++ /dev/null @@ -1,92 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.05.03 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.plus.csv deleted file mode 100644 index 65f702f4..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10503.10603.plus.csv +++ /dev/null @@ -1,126 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.05.03 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.csv deleted file mode 100644 index a6ab1cbc..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.csv +++ /dev/null @@ -1,100 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.plus.csv deleted file mode 100644 index edc9f7fc..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10604.10605.plus.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.csv deleted file mode 100644 index 263f11a0..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.csv +++ /dev/null @@ -1,102 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.plus.csv deleted file mode 100644 index 99105a26..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10606.10607.plus.csv +++ /dev/null @@ -1,154 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.csv deleted file mode 100644 index 0bf0d9fb..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.csv +++ /dev/null @@ -1,104 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.plus.csv deleted file mode 100644 index b2df8bc0..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10608.10706.plus.csv +++ /dev/null @@ -1,156 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.csv deleted file mode 100644 index 3c7689a8..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.csv +++ /dev/null @@ -1,104 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.plus.csv deleted file mode 100644 index 371d0a23..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10801.10805.plus.csv +++ /dev/null @@ -1,164 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.csv deleted file mode 100644 index 35f8cbd5..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.csv +++ /dev/null @@ -1,124 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.plus.csv deleted file mode 100644 index a21d8636..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent180.10806.99999.plus.csv +++ /dev/null @@ -1,166 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent180 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent180,,,,[fill_your_slave_address_here], -*w,Excellent180,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:180;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:180;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:180;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:180],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.csv deleted file mode 100644 index 61f006d9..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.csv +++ /dev/null @@ -1,91 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.plus.csv deleted file mode 100644 index 6891f03a..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10502.10603.plus.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.csv deleted file mode 100644 index c9c1e241..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.plus.csv deleted file mode 100644 index 39d96d11..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10604.10605.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.csv deleted file mode 100644 index 3109f9f8..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.plus.csv deleted file mode 100644 index 73eb19d6..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10606.10607.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.csv deleted file mode 100644 index d5164ac5..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.plus.csv deleted file mode 100644 index 12276ad3..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10608.10706.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.csv deleted file mode 100644 index 71838f54..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.plus.csv deleted file mode 100644 index 50a23eed..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10801.10805.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.csv deleted file mode 100644 index b8e588f7..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] diff --git a/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.plus.csv deleted file mode 100644 index 57c0bbb9..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent300.10806.99999.plus.csv +++ /dev/null @@ -1,165 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent300,,,,[fill_your_slave_address_here], -*w,Excellent300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.csv deleted file mode 100644 index 8f35eb71..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.csv +++ /dev/null @@ -1,85 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.04.01 to 1.04.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.plus.csv deleted file mode 100644 index b2704904..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10401.10403.plus.csv +++ /dev/null @@ -1,119 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.04.01 to 1.04.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:6;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:6],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:6;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:6],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:6;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:6],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:6;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:6],Step,,UIR,,,[step:1],Default,,UIR,,,[default:5] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.csv deleted file mode 100644 index 76049b2e..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.csv +++ /dev/null @@ -1,91 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.plus.csv deleted file mode 100644 index 79a3795d..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10502.10603.plus.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.csv deleted file mode 100644 index 559fcb8a..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.plus.csv deleted file mode 100644 index 5857621b..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10604.10605.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.csv deleted file mode 100644 index acd2aaea..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.plus.csv deleted file mode 100644 index 480249c4..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10606.10607.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.csv deleted file mode 100644 index 6e186a3d..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.plus.csv deleted file mode 100644 index 0752b174..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10608.10706.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.csv deleted file mode 100644 index 77e4c256..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.plus.csv deleted file mode 100644 index 7820ca2b..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10801.10805.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.csv deleted file mode 100644 index 7d36c431..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] diff --git a/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.plus.csv deleted file mode 100644 index aa878bdb..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent400.10806.99999.plus.csv +++ /dev/null @@ -1,165 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent400 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent400,,,,[fill_your_slave_address_here], -*w,Excellent400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.csv deleted file mode 100644 index 9893f620..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.plus.csv deleted file mode 100644 index 2c6bd3fc..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10604.10605.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.csv deleted file mode 100644 index d56f1f03..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.plus.csv deleted file mode 100644 index ef1cc5d2..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10606.10607.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.csv deleted file mode 100644 index 9bb6d3e0..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.plus.csv deleted file mode 100644 index c0686c1f..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10608.10706.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.csv deleted file mode 100644 index 76c4f9c4..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.plus.csv deleted file mode 100644 index ee3ed3d4..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10801.10805.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.csv deleted file mode 100644 index fce321bb..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] diff --git a/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.plus.csv deleted file mode 100644 index 226e4bfd..00000000 --- a/ebusd-configuration-unknown-slave-address/Excellent450.10806.99999.plus.csv +++ /dev/null @@ -1,165 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Excellent450 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Excellent450,,,,[fill_your_slave_address_here], -*w,Excellent450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/Flair200.10101.99999.csv deleted file mode 100644 index ee86ba6a..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair200.10101.99999.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair200 SW version from 1.01.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair200,,,,[fill_your_slave_address_here], -*w,Flair200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:200;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:200] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/Flair225.10101.99999.csv deleted file mode 100644 index 9f262f5a..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair225.10101.99999.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair225 SW version from 1.01.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair225,,,,[fill_your_slave_address_here], -*w,Flair225,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:225;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:225],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:225;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:225],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:225;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:225],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:225;step:5;default:175] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:225],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:175] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/Flair300.10101.20105.csv deleted file mode 100644 index ad8f0fd7..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair300.10101.20105.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair300 SW version from 1.01.01 to 2.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair300,,,,[fill_your_slave_address_here], -*w,Flair300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:300;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/Flair300.20106.99999.csv deleted file mode 100644 index 4b240bd3..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair300.20106.99999.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair300 SW version from 2.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair300,,,,[fill_your_slave_address_here], -*w,Flair300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:300;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/Flair325.10101.20105.csv deleted file mode 100644 index 5b60f537..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair325.10101.20105.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair325 SW version from 1.01.01 to 2.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair325,,,,[fill_your_slave_address_here], -*w,Flair325,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:325;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/Flair325.20106.99999.csv deleted file mode 100644 index 167db591..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair325.20106.99999.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair325 SW version from 2.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair325,,,,[fill_your_slave_address_here], -*w,Flair325,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:325;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/Flair400.10101.20105.csv deleted file mode 100644 index 77dab72f..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair400.10101.20105.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair400 SW version from 1.01.01 to 2.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair400,,,,[fill_your_slave_address_here], -*w,Flair400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:400;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/Flair400.20106.99999.csv deleted file mode 100644 index 436b4624..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair400.20106.99999.csv +++ /dev/null @@ -1,222 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair400 SW version from 2.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair400,,,,[fill_your_slave_address_here], -*w,Flair400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:400;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/Flair450.10101.99999.csv deleted file mode 100644 index 6498c6b8..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair450.10101.99999.csv +++ /dev/null @@ -1,223 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair450 SW version from 1.01.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair450,,,,[fill_your_slave_address_here], -*w,Flair450,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,InsideTemperature,,,4022,08,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:450;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:450;step:5;default:125] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:450;step:5;default:250] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:450;step:5;default:350] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:450],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:350] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/Flair600.10101.99999.csv deleted file mode 100644 index fd0ff83b..00000000 --- a/ebusd-configuration-unknown-slave-address/Flair600.10101.99999.csv +++ /dev/null @@ -1,223 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Flair600 SW version from 1.01.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Flair600,,,,[fill_your_slave_address_here], -*w,Flair600,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,InsideTemperature,,,4022,08,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:600;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:600;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:600;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:600;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:5;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:90] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TypKomunikacjiRS485,RS485Mode,,,4080,80,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,TypKomunikacjiRS485,RS485Mode,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,41,,,UIR,,,[min:1;max:247;step:1;default:20] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:20] -w,,PrędkośćModBus,ModbusSpeed,,,4080,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:4] -r,,PrędkośćModBus,ModbusSpeed,,,4050,42,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:4] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,43,,,UIR,,,[min:0;max:2;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,43,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,,,[min:0;max:8;step:1;default:0] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4080,70,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego1,AnaInput1Mode,,,4050,70,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4080,71,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWejściaAnalogowego2,AnaInput2Mode,,,4050,71,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4080,73,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,PozycjaDomyślnaZaworuGHE,EWTValveDefaultPos,,,4050,73,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4080,72,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,WyjścieUżywanegoZaworuGHE,EWTValveOutput,,,4050,72,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.0.10101.csv deleted file mode 100644 index 5c9a1291..00000000 --- a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.0.10101.csv +++ /dev/null @@ -1,50 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for MultiRoomCtrlT01 SW version from 0.. to 1.01.01 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], -*w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hour, -r,,StatusMRC,MRCStatus,,,4022,82,,,UIR,0=Error;1=NotInitialized;2=Idle;3=PowerUp;4=Running,, -r,,StatusKonfiguracjiMRC,MRCConfigurationStatus,,,4022,a0,,,HEX:9,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4080,a0,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4050,a0,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4080,a1,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4050,a1,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4080,a2,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4050,a2,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4080,a3,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4050,a3,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4080,a4,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4050,a4,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4080,a5,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4050,a5,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4080,a6,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4050,a6,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] diff --git a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10102.10102.csv deleted file mode 100644 index 8894d69e..00000000 --- a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10102.10102.csv +++ /dev/null @@ -1,58 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for MultiRoomCtrlT01 SW version 1.01.02 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], -*w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hour, -r,,StatusMRC,MRCStatus,,,4022,82,,,UIR,0=Error;1=NotInitialized;2=Idle;3=PowerUp;4=Running,, -r,,StatusKonfiguracjiMRC,MRCConfigurationStatus,,,4022,a0,,,HEX:9,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4080,a0,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4050,a0,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4080,a1,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4050,a1,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4080,a2,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4050,a2,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4080,a3,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4050,a3,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4080,a4,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4050,a4,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4080,a5,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4050,a5,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4080,a6,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4050,a6,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,ŁazienkaOpóźnienieUruchomienia,BathroomStartDelay,,,4080,ab,,,UIR,,Minutes,[min:0;max:10;step:1;default:6] -r,,ŁazienkaOpóźnienieUruchomienia,BathroomStartDelay,,,4050,ab,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:10],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:6] -w,,ŁazienkaCzasWybiegu,BathroomRunoutTime,,,4080,ac,,,UIR,,Minutes,[min:15;max:60;step:1;default:20] -r,,ŁazienkaCzasWybiegu,BathroomRunoutTime,,,4050,ac,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:15],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:20] -w,,KuchniaCzasWybiegu,KitchenRunoutTime,,,4080,ad,,,UIR,,Minutes,[min:0;max:60;step:1;default:30] -r,,KuchniaCzasWybiegu,KitchenRunoutTime,,,4050,ad,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:30] -w,,KuchniaTypŁącznikaWzmocnienia,KitchenSwitchType,,,4080,ae,,,UIR,,,[min:0;max:1;step:1;default:1] -r,,KuchniaTypŁącznikaWzmocnienia,KitchenSwitchType,,,4050,ae,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] diff --git a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10103.99999.csv deleted file mode 100644 index 305b23d3..00000000 --- a/ebusd-configuration-unknown-slave-address/MultiRoomCtrlT01.10103.99999.csv +++ /dev/null @@ -1,80 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for MultiRoomCtrlT01 SW version from 1.01.03 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], -*w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hour, -r,,StatusMRC,MRCStatus,,,4022,82,,,UIR,0=Error;1=NotInitialized;2=Idle;3=PowerUp;4=Running,, -r,,StatusKonfiguracjiMRC,MRCConfigurationStatus,,,4022,a0,,,HEX:9,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4080,a0,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMKuchnia,PPMThresholdKitchen,,,4050,a0,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4080,a1,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka1,PPMThresholdUnit01,,,4050,a1,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4080,a2,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka2,PPMThresholdUnit02,,,4050,a2,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4080,a3,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka3,PPMThresholdUnit03,,,4050,a3,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4080,a4,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka4,PPMThresholdUnit04,,,4050,a4,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4080,a5,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka5,PPMThresholdUnit05,,,4050,a5,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4080,a6,,,UIR,,ppm,[min:0;max:2000;step:10;default:600] -r,,WartośćProgowaPPMJednostka6,PPMThresholdUnit06,,,4050,a6,,,UIR,,ppm,,Min,,UIR,,ppm,[min:0],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:10],Default,,UIR,,ppm,[default:600] -w,,ŁazienkaOpóźnienieUruchomienia,BathroomStartDelay,,,4080,ab,,,UIR,,Minutes,[min:0;max:10;step:1;default:6] -r,,ŁazienkaOpóźnienieUruchomienia,BathroomStartDelay,,,4050,ab,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:10],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:6] -w,,ŁazienkaCzasWybiegu,BathroomRunoutTime,,,4080,ac,,,UIR,,Minutes,[min:15;max:60;step:1;default:20] -r,,ŁazienkaCzasWybiegu,BathroomRunoutTime,,,4050,ac,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:15],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:20] -w,,KuchniaCzasWybiegu,KitchenRunoutTime,,,4080,ad,,,UIR,,Minutes,[min:0;max:60;step:1;default:30] -r,,KuchniaCzasWybiegu,KitchenRunoutTime,,,4050,ad,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:30] -w,,KuchniaTypŁącznikaWzmocnienia,KitchenSwitchType,,,4080,ae,,,UIR,,,[min:0;max:1;step:1;default:1] -r,,KuchniaTypŁącznikaWzmocnienia,KitchenSwitchType,,,4050,ae,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,NastawaPrzepływuKorytarz,SetpointFlowHallway,,,4080,af,,,UIR,,m³/h,[min:0;max:50;step:5;default:25] -r,,NastawaPrzepływuKorytarz,SetpointFlowHallway,,,4050,af,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:50],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:25] -w,,NastawaPrzepływuWTWUstawienie1,SetpointFlowWTWSetting1,,,4080,b0,,,UIR,,m³/h,[min:50;max:400;step:5;default:75] -r,,NastawaPrzepływuWTWUstawienie1,SetpointFlowWTWSetting1,,,4050,b0,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:75] -w,,NastawaPrzepływuWTWUstawienie2,SetpointFlowWTWSetting2,,,4080,b1,,,UIR,,m³/h,[min:50;max:400;step:5;default:125] -r,,NastawaPrzepływuWTWUstawienie2,SetpointFlowWTWSetting2,,,4050,b1,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:125] -w,,NastawaPrzepływuWTWUstawienie3,SetpointFlowWTWSetting3,,,4080,b2,,,UIR,,m³/h,[min:50;max:400;step:5;default:175] -r,,NastawaPrzepływuWTWUstawienie3,SetpointFlowWTWSetting3,,,4050,b2,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:175] -w,,NastawaPrzepływuWTWUstawienie4,SetpointFlowWTWSetting4,,,4080,b3,,,UIR,,m³/h,[min:50;max:400;step:5;default:125] -r,,NastawaPrzepływuWTWUstawienie4,SetpointFlowWTWSetting4,,,4050,b3,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:125] -w,,NastawaPrzepływuWTWUstawienie5,SetpointFlowWTWSetting5,,,4080,b4,,,UIR,,m³/h,[min:50;max:400;step:5;default:175] -r,,NastawaPrzepływuWTWUstawienie5,SetpointFlowWTWSetting5,,,4050,b4,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:175] -w,,NastawaPrzepływuWTWUstawienie6,SetpointFlowWTWSetting6,,,4080,b5,,,UIR,,m³/h,[min:50;max:400;step:5;default:225] -r,,NastawaPrzepływuWTWUstawienie6,SetpointFlowWTWSetting6,,,4050,b5,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:225] -w,,NastawaPrzepływuWTWUstawienie7,SetpointFlowWTWSetting7,,,4080,b6,,,UIR,,m³/h,[min:50;max:400;step:5;default:175] -r,,NastawaPrzepływuWTWUstawienie7,SetpointFlowWTWSetting7,,,4050,b6,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:175] -w,,NastawaPrzepływuWTWUstawienie8,SetpointFlowWTWSetting8,,,4080,b7,,,UIR,,m³/h,[min:50;max:400;step:5;default:225] -r,,NastawaPrzepływuWTWUstawienie8,SetpointFlowWTWSetting8,,,4050,b7,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:225] -w,,NastawaPrzepływuWTWUstawienie9,SetpointFlowWTWSetting9,,,4080,b8,,,UIR,,m³/h,[min:50;max:400;step:5;default:275] -r,,NastawaPrzepływuWTWUstawienie9,SetpointFlowWTWSetting9,,,4050,b8,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:50],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:275] -w,,PrzepływMaksymalnyWTWWydajność,WTWFlowMaximum,,,4080,b9,,,UIR,,m³/h,[min:0;max:1000;step:5;default:400] -r,,PrzepływMaksymalnyWTWWydajność,WTWFlowMaximum,,,4050,b9,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:1000],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:400] diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.csv deleted file mode 100644 index f091f12f..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.csv +++ /dev/null @@ -1,90 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.07.03 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.plus.csv deleted file mode 100644 index f091f12f..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10703.10706.plus.csv +++ /dev/null @@ -1,90 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.07.03 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.csv deleted file mode 100644 index f12ca400..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.csv +++ /dev/null @@ -1,90 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.plus.csv deleted file mode 100644 index 2ed6b89a..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10801.10805.plus.csv +++ /dev/null @@ -1,98 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.csv deleted file mode 100644 index 6fef04c1..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.csv +++ /dev/null @@ -1,100 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.plus.csv deleted file mode 100644 index 6fef04c1..00000000 --- a/ebusd-configuration-unknown-slave-address/Nather300.10806.99999.plus.csv +++ /dev/null @@ -1,100 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Nather300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Nather300,,,,[fill_your_slave_address_here], -*w,Nather300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:230] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:230] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.csv deleted file mode 100644 index aebd515c..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.csv +++ /dev/null @@ -1,100 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.plus.csv deleted file mode 100644 index f8675841..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10604.10605.plus.csv +++ /dev/null @@ -1,152 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.csv deleted file mode 100644 index 5ef14727..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.csv +++ /dev/null @@ -1,102 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.plus.csv deleted file mode 100644 index 1bb53945..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10606.10607.plus.csv +++ /dev/null @@ -1,154 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.csv deleted file mode 100644 index a3e4b7f5..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.csv +++ /dev/null @@ -1,104 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.plus.csv deleted file mode 100644 index f6af5369..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10608.10706.plus.csv +++ /dev/null @@ -1,156 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.csv deleted file mode 100644 index 7611ccda..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.csv +++ /dev/null @@ -1,104 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.plus.csv deleted file mode 100644 index 376b3f84..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10801.10805.plus.csv +++ /dev/null @@ -1,164 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.csv deleted file mode 100644 index 4d90ca83..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.csv +++ /dev/null @@ -1,106 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.plus.csv deleted file mode 100644 index daf16aec..00000000 --- a/ebusd-configuration-unknown-slave-address/RenoventElan300.10806.99999.plus.csv +++ /dev/null @@ -1,166 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for RenoventElan300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,RenoventElan300,,,,[fill_your_slave_address_here], -*w,RenoventElan300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:70;step:70;default:70] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:70],Step,,SIR,,m³/h,[step:70],Default,,SIR,,m³/h,[default:70] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:70;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:70;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:70;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:70],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.csv deleted file mode 100644 index 31309cc7..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.csv +++ /dev/null @@ -1,89 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.05.04 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.plus.csv deleted file mode 100644 index ad04fbb5..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10504.10603.plus.csv +++ /dev/null @@ -1,123 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.05.04 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.csv deleted file mode 100644 index 1881f00f..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.csv +++ /dev/null @@ -1,97 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.plus.csv deleted file mode 100644 index 4af23c2c..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10604.10605.plus.csv +++ /dev/null @@ -1,149 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.csv deleted file mode 100644 index 20c5a644..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.plus.csv deleted file mode 100644 index 1ba0cefc..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10606.10607.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.csv deleted file mode 100644 index 72bbae9e..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.plus.csv deleted file mode 100644 index fd1e5b0a..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10608.10706.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.csv deleted file mode 100644 index ddf66d1e..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.plus.csv deleted file mode 100644 index b3c49d25..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10801.10805.plus.csv +++ /dev/null @@ -1,161 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.csv deleted file mode 100644 index 12a56af6..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] diff --git a/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.plus.csv deleted file mode 100644 index 771baa5c..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky150.10806.99999.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky150 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky150,,,,[fill_your_slave_address_here], -*w,Sky150,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.csv deleted file mode 100644 index 090edb80..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.07.02 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.plus.csv deleted file mode 100644 index 2c10ac62..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10702.10706.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.07.02 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.csv deleted file mode 100644 index e57dabe0..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.plus.csv deleted file mode 100644 index 650629fb..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10801.10805.plus.csv +++ /dev/null @@ -1,161 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.csv deleted file mode 100644 index 1dc461b4..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] diff --git a/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.plus.csv deleted file mode 100644 index b39d665a..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky200.10806.99999.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky200 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky200,,,,[fill_your_slave_address_here], -*w,Sky200,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:200;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:200;step:5;default:125] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:200;step:5;default:150] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:200],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.csv deleted file mode 100644 index d7312d25..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.csv +++ /dev/null @@ -1,85 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.04.01 to 1.04.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.plus.csv deleted file mode 100644 index 35dab035..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10401.10403.plus.csv +++ /dev/null @@ -1,119 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.04.01 to 1.04.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.csv deleted file mode 100644 index 577fbbe8..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.csv +++ /dev/null @@ -1,91 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.plus.csv deleted file mode 100644 index bb3c4e5c..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10502.10603.plus.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.05.02 to 1.06.03 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.csv deleted file mode 100644 index 9ea70af6..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.plus.csv deleted file mode 100644 index 0f7ff1be..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10604.10605.plus.csv +++ /dev/null @@ -1,151 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.04 to 1.06.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.csv deleted file mode 100644 index 9d5358f4..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.plus.csv deleted file mode 100644 index cae8f427..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10606.10607.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.06 to 1.06.07 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.csv deleted file mode 100644 index 2d6b6163..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.plus.csv deleted file mode 100644 index b7819837..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10608.10706.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.06.08 to 1.07.06 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.csv deleted file mode 100644 index 977b71ea..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.plus.csv deleted file mode 100644 index 293f9cb5..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10801.10805.plus.csv +++ /dev/null @@ -1,163 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.08.01 to 1.08.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.csv deleted file mode 100644 index bb919e84..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.csv +++ /dev/null @@ -1,125 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.plus.csv deleted file mode 100644 index 21b208b1..00000000 --- a/ebusd-configuration-unknown-slave-address/Sky300.10806.99999.plus.csv +++ /dev/null @@ -1,165 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Sky300 SW version from 1.08.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Sky300,,,,[fill_your_slave_address_here], -*w,Sky300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4080,31,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,PodłączenieNagrzewnicyWstępnej,PreheaterPresent,,,4050,31,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,45,,,UIR,,,[min:1;max:365;step:1;default:90] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,45,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:365],Step,,UIR,,,[step:1],Default,,UIR,,,[default:90] -w,,InterfejsModBus,ModbusInterface,,,4080,41,,,UIR,,,[min:0;max:3;step:2;default:1] -r,,InterfejsModBus,ModbusInterface,,,4050,41,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:2],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4080,42,,,UIR,,,[min:1;max:247;step:1;default:11] -r,,AdresUrządzeniaPodrzędnegoModBus,ModbusSlaveAddress,,,4050,42,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:247],Step,,UIR,,,[step:1],Default,,UIR,,,[default:11] -w,,PrędkośćModBus,ModbusSpeed,,,4080,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[min:0;max:7;step:1;default:3] -r,,PrędkośćModBus,ModbusSpeed,,,4050,43,,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,,,,IGN:6,,,,Default,,UIR,0=1200 Baud;1=2400 Baud;2=4800 Baud;3=9600 Baud;4=19k2 Baud;5=38k4 Baud;6=56k Baud;7=115k Baud,,[default:3] - min/max/step fields of enum message omitted -w,,ParzystośćModBus,ModbusParity,,,4080,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[min:0;max:3;step:1;default:1] -r,,ParzystośćModBus,ModbusParity,,,4050,44,,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,,,,IGN:6,,,,Default,,UIR,0=No Parity;1=Even Parity;2=Odd Parity;3=Unknown,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/ValveT01.0.99999.csv deleted file mode 100644 index 41e57792..00000000 --- a/ebusd-configuration-unknown-slave-address/ValveT01.0.99999.csv +++ /dev/null @@ -1,83 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for ValveT01 SW version from 0.. to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,ValveT01,,,,[fill_your_slave_address_here], -*w,ValveT01,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,UCH,,, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,Hour, -r,,StatusZaworu,ValveStatus,,,4022,82,,,UIR,0=Error;1=NotInitialized;2=NotCalibrated;3=Traveling;4=InPosition;5=Calibrating,, -r,,PozycjaZaworu,ValvePosition,,,4022,81,,,UIR,,, -r,,LiczbaStopniPozycjiKońcowej,EndPositionStepCount,,,4022,89,,,UIR,,Steps, -r,,LiczbaStopniPozycji,PositionStepCount,,,4022,8a,,,UIR,,Steps, -r,,KierunekBiegu,RunDirection,,,4022,8b,,,UIR,0=CW;1=CCW,, -r,,KonfiguracjaStrefyPoprawna,ConfigurationValid,,,4022,8c,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,NumerGrupyEBus,EBusGroupNumber,,,4080,d0,,,UIR,,,[min:1;max:8;step:1;default:1] -r,,NumerGrupyEBus,EBusGroupNumber,,,4050,d0,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:8],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,AdresUrządzeniaPodrzędnegoEBus,EBusSlaveNumber,,,4080,d1,,,UIR,,,[min:1;max:9;step:1;default:1] -r,,AdresUrządzeniaPodrzędnegoEBus,EBusSlaveNumber,,,4050,d1,,,UIR,,,,Min,,UIR,,,[min:1],Max,,UIR,,,[max:9],Step,,UIR,,,[step:1],Default,,UIR,,,[default:1] -w,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4080,d2,,,UIR,,Minutes,[min:0;max:60;step:1;default:15] -r,,LimitCzasowyHeartbeat,HeartBeatTimeout,,,4050,d2,,,UIR,,Minutes,,Min,,UIR,,Minutes,[min:0],Max,,UIR,,Minutes,[max:60],Step,,UIR,,Minutes,[step:1],Default,,UIR,,Minutes,[default:15] -w,,StrefaPozycji1,PositionZone01,,,4080,80,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,StrefaPozycji1,PositionZone01,,,4050,80,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,StrefaPozycji2,PositionZone02,,,4080,81,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,StrefaPozycji2,PositionZone02,,,4050,81,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,PozycjaBezpieczna,SafePosition,,,4080,82,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,PozycjaBezpieczna,SafePosition,,,4050,82,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,OczekiwanaPozycjaKońcowa,ExpectedEndPosition,,,4080,83,,,UIR,,,[min:0;max:6000;step:1;default:2825] -r,,OczekiwanaPozycjaKońcowa,ExpectedEndPosition,,,4050,83,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:6000],Step,,UIR,,,[step:1],Default,,UIR,,,[default:2825] -w,,TolerancjaKalibracji,CalibrationTolerance,,,4080,84,,,UIR,,,[min:0;max:200;step:1;default:50] -r,,TolerancjaKalibracji,CalibrationTolerance,,,4050,84,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:200],Step,,UIR,,,[step:1],Default,,UIR,,,[default:50] -w,,TolerancjePozycji,PositionTolerance,,,4080,85,,,UIR,,,[min:0;max:200;step:1;default:50] -r,,TolerancjePozycji,PositionTolerance,,,4050,85,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:200],Step,,UIR,,,[step:1],Default,,UIR,,,[default:50] -w,,PrzepływMaksymalny,FlowMaximum,,,4080,86,,,UIR,,m³/h,[min:0;max:400;step:5;default:100] -r,,PrzepływMaksymalny,FlowMaximum,,,4050,86,,,UIR,,m³/h,,Min,,UIR,,m³/h,[min:0],Max,,UIR,,m³/h,[max:400],Step,,UIR,,m³/h,[step:5],Default,,UIR,,m³/h,[default:100] -w,,KątPozycjiKońcowej,EndPositionAngle,,,4080,87,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,KątPozycjiKońcowej,EndPositionAngle,,,4050,87,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,LiczbaPozycji,NrOfPositions,,,4080,88,,,UIR,,,[min:2;max:10;step:1;default:2] -r,,LiczbaPozycji,NrOfPositions,,,4050,88,,,UIR,,,,Min,,UIR,,,[min:2],Max,,UIR,,,[max:10],Step,,UIR,,,[step:1],Default,,UIR,,,[default:2] -w,,PozycjaKątowa0,PositionAngle00,,,4080,89,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa0,PositionAngle00,,,4050,89,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa1,PositionAngle01,,,4080,8a,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa1,PositionAngle01,,,4050,8a,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa2,PositionAngle02,,,4080,8b,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa2,PositionAngle02,,,4050,8b,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa3,PositionAngle03,,,4080,8c,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa3,PositionAngle03,,,4050,8c,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa4,PositionAngle04,,,4080,8d,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa4,PositionAngle04,,,4050,8d,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa5,PositionAngle05,,,4080,8e,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa5,PositionAngle05,,,4050,8e,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa6,PositionAngle06,,,4080,8f,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa6,PositionAngle06,,,4050,8f,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa7,PositionAngle07,,,4080,90,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa7,PositionAngle07,,,4050,90,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa8,PositionAngle08,,,4080,91,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa8,PositionAngle08,,,4050,91,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] -w,,PozycjaKątowa9,PositionAngle09,,,4080,92,,,UIR,,°,[min:0;max:360;step:1;default:180] -r,,PozycjaKątowa9,PositionAngle09,,,4050,92,,,UIR,,°,,Min,,UIR,,°,[min:0],Max,,UIR,,°,[max:360],Step,,UIR,,°,[step:1],Default,,UIR,,°,[default:180] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.csv deleted file mode 100644 index 7328fbe9..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.csv +++ /dev/null @@ -1,94 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version 1.01.04 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.plus.csv deleted file mode 100644 index 7328fbe9..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10104.10104.plus.csv +++ /dev/null @@ -1,94 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version 1.01.04 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.csv deleted file mode 100644 index 58a160be..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WyświetlPozycjęPrzełącznika,DispSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4080,2a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4050,2a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,2b,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,2b,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.plus.csv deleted file mode 100644 index 58a160be..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10105.10105.plus.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WyświetlPozycjęPrzełącznika,DispSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4080,2a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4050,2a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,2b,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,2b,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.csv deleted file mode 100644 index 303e0bd5..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WyświetlPozycjęPrzełącznika,DispSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4080,2a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4050,2a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,2b,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,2b,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.plus.csv deleted file mode 100644 index 303e0bd5..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent200W.10106.99999.plus.csv +++ /dev/null @@ -1,99 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent200W SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent200W,,,,[fill_your_slave_address_here], -*w,Vitovent200W,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,%, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,%, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,%, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,%, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WyświetlPozycjęPrzełącznika,DispSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,RPMNawiewTryb0,RpmInletMode0,,,4080,01,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMNawiewTryb0,RpmInletMode0,,,4050,01,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMWywiewTryb0,RpmExhaustMode0,,,4080,02,,,SIR,,%,[min:10;max:100;step:1;default:15] -r,,RPMWywiewTryb0,RpmExhaustMode0,,,4050,02,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:15] -w,,RPMNawiewTryb1,RpmInletMode1,,,4080,03,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMNawiewTryb1,RpmInletMode1,,,4050,03,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMWywiewTryb1,RpmExhaustMode1,,,4080,04,,,SIR,,%,[min:10;max:100;step:1;default:25] -r,,RPMWywiewTryb1,RpmExhaustMode1,,,4050,04,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:25] -w,,RPMNawiewTryb2,RpmInletMode2,,,4080,05,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMNawiewTryb2,RpmInletMode2,,,4050,05,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMWywiewTryb2,RpmExhaustMode2,,,4080,06,,,SIR,,%,[min:10;max:100;step:1;default:50] -r,,RPMWywiewTryb2,RpmExhaustMode2,,,4050,06,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:50] -w,,RPMNawiewTryb3,RpmInletMode3,,,4080,07,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMNawiewTryb3,RpmInletMode3,,,4050,07,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,RPMWywiewTryb3,RpmExhaustMode3,,,4080,08,,,SIR,,%,[min:10;max:100;step:1;default:75] -r,,RPMWywiewTryb3,RpmExhaustMode3,,,4050,08,,,SIR,,%,,Min,,SIR,,%,[min:10],Max,,SIR,,%,[max:100],Step,,SIR,,%,[step:1],Default,,SIR,,%,[default:75] -w,,TemperaturaByPassu,BypassTemp,,,4080,0a,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,0a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,0b,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,09,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,09,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4080,0d,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,DodatkowaNagrzewnicaWstępnaObecna,ExtraPreheater,,,4050,0d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,0e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,0e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,0f,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,0f,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,10,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,10,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4080,2a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,WłączPrzełącznikWyświetlania,DispSwitchActive,,,4050,2a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,2b,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,2b,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.csv deleted file mode 100644 index df9793be..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300C SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300C,,,,[fill_your_slave_address_here], -*w,Vitovent300C,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.plus.csv deleted file mode 100644 index 144ffe27..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300C.10101.10105.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300C SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300C,,,,[fill_your_slave_address_here], -*w,Vitovent300C,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.csv deleted file mode 100644 index 1baabe52..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.csv +++ /dev/null @@ -1,101 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300C SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300C,,,,[fill_your_slave_address_here], -*w,Vitovent300C,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.plus.csv deleted file mode 100644 index 0572f364..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300C.10106.99999.plus.csv +++ /dev/null @@ -1,153 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300C SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300C,,,,[fill_your_slave_address_here], -*w,Vitovent300C,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:30;default:30] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:30],Default,,SIR,,m³/h,[default:30] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:30;max:150;step:5;default:75] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:75] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:30;max:150;step:5;default:100] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:30;max:150;step:5;default:125] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:30],Max,,SIR,,m³/h,[max:150],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:125] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-50;max:50;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-50],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.csv deleted file mode 100644 index 9d388963..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W300 SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W300,,,,[fill_your_slave_address_here], -*w,Vitovent300W300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.plus.csv deleted file mode 100644 index 8354b89a..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10101.10105.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W300 SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W300,,,,[fill_your_slave_address_here], -*w,Vitovent300W300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.csv deleted file mode 100644 index f40843f2..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W300 SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W300,,,,[fill_your_slave_address_here], -*w,Vitovent300W300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.plus.csv deleted file mode 100644 index d874c035..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W300.10106.99999.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W300 SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W300,,,,[fill_your_slave_address_here], -*w,Vitovent300W300,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:300;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:300;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:300;step:5;default:225] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:300],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:225] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.csv deleted file mode 100644 index e4182409..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W400 SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W400,,,,[fill_your_slave_address_here], -*w,Vitovent300W400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.plus.csv deleted file mode 100644 index ae5898d3..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10101.10105.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W400 SW version from 1.01.01 to 1.01.05 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W400,,,,[fill_your_slave_address_here], -*w,Vitovent300W400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:220] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:220] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.csv deleted file mode 100644 index 0bdb10b9..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.csv +++ /dev/null @@ -1,103 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W400 SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W400,,,,[fill_your_slave_address_here], -*w,Vitovent300W400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.plus.csv deleted file mode 100644 index 7b1e3131..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300W400.10106.99999.plus.csv +++ /dev/null @@ -1,155 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300W400 SW version from 1.01.06 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300W400,,,,[fill_your_slave_address_here], -*w,Vitovent300W400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,PozycjaPerilex,PerilexPosition,,,4022,05,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,PrzełączyćPozycję,SwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,Kontakt1Pozycję,Contact1Position,,,4022,1b,,,UIR,0=Off;1=On,, -r,,Kontakt2Pozycję,Contact2Position,,,4022,1c,,,UIR,0=Off;1=On,, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,, -r,,ByPassuPrąd,BypassCurrent,,,4022,0d,,,UIR,,, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,StatusNagrzewnicyWtórnej,PostheaterStatus,,,4022,1d,,,UIR,0=Initializing;1=Off;2=On,, -r,,MocNagrzewnicyWtórnej,PostheaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=NoFrost;17=NoFrost;2=DefrostWait;3=Preheater;18=Preheater;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,, -r,,StatusWentylatorów,FanStatus,,,4022,11,,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,, -r,,TempWewn,InsideTemperature,,,4022,07,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,08,,,SIR,10,°C, -r,,UstawieniaOpcjiTemp,OptionTemperature,,,4022,1a,,,SIR,10,°C, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa, -r,,AktualneCiśnienieNawiewu,PressureInlet,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,PressureExhaust,,,4022,15,,,UIR,10,Pa, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,TemperaturaByPassu,BypassTemp,,,4080,04,,,SIR,10,°C,[min:100;max:300;step:5;default:200] -r,,TemperaturaByPassu,BypassTemp,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:100],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:200] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,SIR,,m³/h,[min:-100;max:100;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:-100],Max,,SIR,,m³/h,[max:100],Step,,SIR,,m³/h,[step:1],Default,,SIR,,m³/h,[default:0] -w,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4080,0a,,,UIR,,,[min:0;max:2;step:1;default:0] -r,,TypDodatkowejNagrzewnicy,ExtraHeaterType,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:2],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,WybórWejścia1,Input1Mode,,,4080,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:0] -r,,WybórWejścia1,Input1Mode,,,4050,0c,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:0] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia1,Input1VMin,,,4080,0d,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia1,Input1VMin,,,4050,0d,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia1,Input1VMax,,,4080,0e,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia1,Input1VMax,,,4050,0e,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt1,CN1Coupling,,,4080,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt1,CN1Coupling,,,4050,0f,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4080,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora1,CN1Inlet,,,4050,10,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4080,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora1,CN1Exhaust,,,4050,11,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WybórWejścia2,Input2Mode,,,4080,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[min:0;max:4;step:1;default:1] -r,,WybórWejścia2,Input2Mode,,,4050,12,,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,,,,IGN:6,,,,Default,,UIR,0=Normally Closed;1=0-10V input;2=Normally Open;3=12V Bypass Open/0V Bypass Closed;4=0V Bypass Open/12V Bypass Closed,,[default:1] - min/max/step fields of enum message omitted -w,,MinNapięcieWejścia2,Input2VMin,,,4080,13,,,SIR,10,V,[min:0;max:100;step:5;default:0] -r,,MinNapięcieWejścia2,Input2VMin,,,4050,13,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:0] -w,,MaxNapięcieWejścia2,Input2VMax,,,4080,14,,,SIR,10,V,[min:0;max:100;step:5;default:100] -r,,MaxNapięcieWejścia2,Input2VMax,,,4050,14,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:5],Default,,SIR,10,V,[default:100] -w,,WarunkiKontakt2,CN2Coupling,,,4080,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[min:0;max:4;step:1;default:0] -r,,WarunkiKontakt2,CN2Coupling,,,4050,15,,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,,,,IGN:6,,,,Default,,UIR,0=off;1=on;2=on if bypass open condition satisfied;3=bypass control;4=Bedroom valve,,[default:0] - min/max/step fields of enum message omitted -w,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4080,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WlotKontaktPracyWentylatora2,CN2Inlet,,,4050,16,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4080,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[min:0;max:7;step:1;default:5] -r,,WyciągKontaktTrybuWentylatora2,CN2Exhaust,,,4050,17,,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,,,IGN:6,,,,Default,,UIR,0=FanOff;1=Minimal flow 50m³/h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted -w,,GWC,EWTMode,,,4080,18,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,GWC,EWTMode,,,4050,18,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,MinimalnaTemperaturaGWC,EWTTempMin,,,4080,19,,,SIR,10,°C,[min:0;max:100;step:5;default:50] -r,,MinimalnaTemperaturaGWC,EWTTempMin,,,4050,19,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:100],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:50] -w,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4080,1a,,,SIR,10,°C,[min:150;max:400;step:5;default:250] -r,,MaksymalnaTemperaturaGWC,EWTTempMax,,,4050,1a,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:400],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:250] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,PoziomPodświetlenia,BacklightLevel,,,4080,1d,,,UIR,,%,[min:0;max:100;step:5;default:10] -r,,PoziomPodświetlenia,BacklightLevel,,,4050,1d,,,UIR,,%,,Min,,UIR,,%,[min:0],Max,,UIR,,%,[max:100],Step,,UIR,,%,[step:5],Default,,UIR,,%,[default:10] -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,KorekcjaPrzepływu,FlowCorrection,,,4080,3f,,,UIR,,%,[min:90;max:110;step:1;default:100] -r,,KorekcjaPrzepływu,FlowCorrection,,,4050,3f,,,UIR,,%,,Min,,UIR,,%,[min:90],Max,,UIR,,%,[max:110],Step,,UIR,,%,[step:1],Default,,UIR,,%,[default:100] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10101.10109.csv deleted file mode 100644 index cacbf062..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10101.10109.csv +++ /dev/null @@ -1,106 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SA225 SW version from 1.01.01 to 1.01.09 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10110.10110.csv deleted file mode 100644 index 9903f8e4..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10110.10110.csv +++ /dev/null @@ -1,174 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SA225 SW version 1.01.10 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10111.99999.csv deleted file mode 100644 index b2aa1709..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA225.10111.99999.csv +++ /dev/null @@ -1,180 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SA225 SW version from 1.01.11 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanActivated,ExternalFanEnable,,,4080,a5,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ExtFanActivated,ExternalFanEnable,,,4050,a5,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanMinimumVoltage,ExternalFanVmin,,,4080,a6,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMinimumVoltage,ExternalFanVmin,,,4050,a6,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] -w,,ExtFanMaximumVoltage,ExternalFanVmax,,,4080,a7,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMaximumVoltage,ExternalFanVmax,,,4050,a7,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA600.10101.99999.csv deleted file mode 100644 index a95a878c..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SA600.10101.99999.csv +++ /dev/null @@ -1,183 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SA600 SW version from 1.01.01 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempWewn,InsideTemperature,,,4022,08,,,SIR,10,°C, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:600;step:5;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:600;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:600;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:600;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:600],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4080,04,,,SIR,10,°C,[min:150;max:350;step:5;default:240] -r,,TemperaturaObejściaOdWewnątrz,BypassTempFromInside,,,4050,04,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:350],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:240] -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanActivated,ExternalFanEnable,,,4080,a5,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ExtFanActivated,ExternalFanEnable,,,4050,a5,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanMinimumVoltage,ExternalFanVmin,,,4080,a6,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMinimumVoltage,ExternalFanVmin,,,4050,a6,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] -w,,ExtFanMaximumVoltage,ExternalFanVmax,,,4080,a7,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMaximumVoltage,ExternalFanVmax,,,4050,a7,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10101.10110.csv deleted file mode 100644 index a7e990af..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10101.10110.csv +++ /dev/null @@ -1,174 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SC325 SW version from 1.01.01 to 1.01.10 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10111.99999.csv deleted file mode 100644 index e45da15d..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC325.10111.99999.csv +++ /dev/null @@ -1,180 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SC325 SW version from 1.01.11 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:325;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:325;step:5;default:150] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:150] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:325;step:5;default:250] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:325],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:250] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanActivated,ExternalFanEnable,,,4080,a5,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ExtFanActivated,ExternalFanEnable,,,4050,a5,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanMinimumVoltage,ExternalFanVmin,,,4080,a6,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMinimumVoltage,ExternalFanVmin,,,4050,a6,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] -w,,ExtFanMaximumVoltage,ExternalFanVmax,,,4080,a7,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMaximumVoltage,ExternalFanVmax,,,4050,a7,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10101.10110.csv deleted file mode 100644 index d02fdb7f..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10101.10110.csv +++ /dev/null @@ -1,174 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SC400 SW version from 1.01.01 to 1.01.10 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] diff --git a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10111.99999.csv deleted file mode 100644 index 1f19e768..00000000 --- a/ebusd-configuration-unknown-slave-address/Vitovent300WH32SC400.10111.99999.csv +++ /dev/null @@ -1,180 +0,0 @@ -# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment,field5,part (m/s),datatypes/templates,divider/values,unit,comment -## This ebus config may work for Ubbink, VisionAIR, WOLF CWL series, Viessmann and some other systems that are just re-branded Brink devices -## sources: -## - Original idea and some dividers: https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 -## - Brink Service Tool (decompiled via Jetbrains DotPeak): https://www.brinkclimatesystems.nl/tools/software-brink-service-tool-en -## - Renovent 150 Datasheet: https://manuals.plus/brink/renovent-sky-150-plus-mechanical-ventilation-with-heat-recovery-manual -## - Modbus Module Datasheet: https://www.brinkclimatesystems.nl/documenten/modbus-uwa2-b-uwa2-e-installation-regulations-614882.pdf -## Message names are based on official Brink Service Tool translations with removed spaces and special characters. -## Message comment is the name of the parameter as used internally in code (as to help if the translation itself is confusing) -## -## For ebusd configuration files for the complete Brink portfolio go to https://github.com/pvyleta/ebusd-brink-hru - -## This file is for Vitovent300WH32SC400 SW version from 1.01.11 to 9.99.99 ## - -## Slave address and Circuit ## -# Fill in the slave address of your device (hexa without '0x' prefix) instead of [fill_your_slave_address_here] -# Then just rename this file to [fill_your_slave_address_here].csv and you should be good to use it in ebusd. -*r,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], -*w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], - -## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, - -## Curent state and sensors ## -r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, -r,,TrybWentylatora,VentilationMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, -r,,AktualnaPrędkośćNawiewu,InletFanSpeed,,,4022,02,,,UIR,,rpm, -r,,AktualnaPrędkośćWywiewu,ExhaustFanSpeed,,,4022,03,,,UIR,,rpm, -r,,WartośćMikrołącznikach,DipswitchValue,,,4022,04,,,UIR,,, -r,,PrzełączyćPozycję,FlowSwitchPosition,,,4022,06,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,TempZewn,OutsideTemperature,,,4022,07,,,SIR,10,°C, -r,,UstawieniaNawiewu,SettingInletFlow,,,4022,09,,,UIR,,m³/h, -r,,UstawieniaWywiewu,SettingExhaustFlow,,,4022,0a,,,UIR,,m³/h, -r,,AktualnyNawiew,InletFlow,,,4022,0b,,,UIR,,m³/h, -r,,AktualnyWywiewFlow,ExhaustFlow,,,4022,0c,,,UIR,,m³/h, -r,,PoziomWykrywaniaObejścia,BypassSenseLevel,,,4022,0d,,,UIR,,m³/h, -r,,StatusByPassu,BypassStatus,,,4022,0e,,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error,m³/h, -r,,StatusNagrzewnicyWstępnej,PreheaterStatus,,,4022,0f,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyWstępnej,PreheaterPower,,,4022,10,,,UIR,,%, -r,,TypSterowaniaWentylatorem,FanControlType,,,4022,11,,,UIR,0=MassBalance;1=ConstantFlow;2=ConstantPWM,, -r,,StatusWentylatoraWlotowego,InletFanStatus,,,4022,12,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,StatusWentylatoraWylotowego,ExhaustFanStatus,,,4022,13,,,UIR,0=NotInitialized;2=NoCommunication;3=Idle;4=Running;5=Blocked;6=Error,, -r,,AktualneCiśnienieNawiewu,InletPressure,,,4022,14,,,UIR,10,Pa, -r,,AktualneCiśnienieWywiewu,ExhaustPressure,,,4022,15,,,UIR,10,Pa, -r,,StatusSystemuPrzeciwzamrożeniowego,FrostStatus,,,4022,16,,,UIR,0=Initializing;1=Initializing;2=NoFrost;3=NoFrostDelay;4=FrostCtrlStartDelay;5=WaitForIcing;6=IceDetectedDelay;7=Preheater;8=HeaterCoolDown;9=FanCtrlStartDelay;10=FanCtrlWait;11=FanCtrl;12=FanCtrlFanOffDelay;13=FanCtrlFanOff;14=FanCtrlFanRestart;15=Error;16=TestMode,, -r,,StatusZasilaniaEBus,eBusPowerStatus,,,4022,17,,,UIR,0=PowerUp;1=Initialize;2=PowerOff;3=PowerOn;4=WaitForPowerOff;5=SlavePowerOff;255=Error,, -r,,PowiadomienieOStanieFiltrów,FilterStatus,,,4022,18,,,UIR,0=Clean;1=Dirty,, -r,,StatusPrzyciskówUIF,UIFButtonsStatus,,,4022,19,,,UIR,,, -r,,UstawieniaOpcjiTemp,ExtTemperature,,,4022,1a,,,SIR,10,°C, -r,,Kontakt1Pozycję,ExtContact1Position,,,4022,1b,,,UIR,0=Open;1=Closed,, -r,,Kontakt2Pozycję,ExtContact2Position,,,4022,1c,,,UIR,0=Open;1=Closed,, -r,,StatusNagrzewnicyZewnętrznej,ExtHeaterStatus,,,4022,1d,,,UIR,0=Off;1=On;2=LockedValue;3=LockedValueMaximum,, -r,,MocNagrzewnicyZewnętrznej,ExtHeaterPower,,,4022,1e,,,UIR,,%, -r,,StatusGWC,EWTStatus,,,4022,1f,,,UIR,0=OpenLow;1=Closed;2=OpenHigh,, -r,,RelativeHumidity,RelativeHumidity,,,4022,20,,,SIR,10,%, -r,,HumidityBoostState,HumidityBoostState,,,4022,21,,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,, -r,,NastawaPWMWentylatoraWlotowego,InletFanPWMValue,,,4022,24,,,UIR,,PWM, -r,,NastawaPWMWentylatoraWylotowego,ExhaustFanPWMValue,,,4022,25,,,UIR,,PWM, -r,,AktywnaFunkcjaWTW,WTWActiveFunction,,,4022,25,,,UIR,0=Standby;1=Bootloader;2=NonBlockingError;3=BlockingError;4=MAnual;5=Holiday;6=NightVentilation;7=Party;8=BypassBoost;9=NormalBoost;10=AutoCO2;11=AutoEBus;12=AutoModbus;13=AutoLanWLanPortal;14=AutoLanWLanLocal,Pa, -r,,StatusCzujnika1CO2,CO2Sensor1Status,,,4022,28,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika1CO2,CO2Sensor1Value,,,4022,29,,,UIR,,ppm, -r,,StatusCzujnika2CO2,CO2Sensor2Status,,,4022,2a,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika2CO2,CO2Sensor2Value,,,4022,2b,,,UIR,,ppm, -r,,StatusCzujnika3CO2,CO2Sensor3Status,,,4022,2c,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika3CO2,CO2Sensor3Value,,,4022,2d,,,UIR,,ppm, -r,,StatusCzujnika4CO2,CO2Sensor4Status,,,4022,2e,,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,, -r,,PoziomCzujnika4CO2,CO2Sensor4Value,,,4022,2f,,,UIR,,ppm, -r,,PozycjaŁącznikaUIF,LocalUIFSwitchPosition,,,4022,30,,,UIR,0=Position_0;1=Position_1;2=Position_2;3=Position_3;,, -r,,ZużycieFiltraDni,FiltersUsedInDays,,,4022,3c,,,UIR,,, -r,,ZużycieFiltra1000m3,FiltersUsedIn1000M3,,,4022,3d,,,UIR,,, -r,,PrzepływCałkowity1000m3,TotalFlowIn1000M3,,,4022,3e,,,UIR,,, -r,,ObniżenieWentylatoraMrozowego,FanFrostReduction,,,4022,3f,,,UIR,,%, -r,,DeviceType,DeviceType,,,4022,40,,,UIR,,, -r,,PozycjaStopniaObejścia,BypassStepPosition,,,4022,43,,,UIR,,, -r,,Temperatura,InletFanSensorTemperature,,,4022,45,,,SIR,10,°C, -r,,Wilgotność,InletFanSensorHumidity,,,4022,46,,,SIR,10,%, -r,,Temperatura,ExhaustFanSensorTemperature,,,4022,47,,,SIR,10,°C, -r,,Wilgotność,ExhaustFanSensorHumidity,,,4022,48,,,SIR,10,%, -r,,WyjścieSygnału,SignalOutput,,,4022,49,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe1,ExtRelayOutput_01,,,4022,4a,,,UIR,0=Off;1=On,, -r,,WyjściePrzekaźnikowe2,ExtRelayOutput_02,,,4022,4b,,,UIR,0=Off;1=On,, -r,,WejścieAnalogowe1,ExtAnaloqueInput_01,,,4022,4c,,,SIR,10,V, -r,,WejścieAnalogowe2,ExtAnaloqueInput_02,,,4022,4d,,,SIR,10,V, -r,,WyjścieAnalogowe1,ExtAnaloqueOutput_01,,,4022,4e,,,SIR,10,V, -r,,WyjścieAnalogowe2,ExtAnaloqueOutput_02,,,4022,4f,,,SIR,10,V, -r,,AdresowanieEBus,EBusAddressing,,,4022,50,,,ULR,,V, -r,,NumerSeryjny,SerialNumber,,,4022,51,,,STR:12,,V, -r,,BłędyZłączaEBus,EBusSyncGenErrorCount,,,4022,64,,,UIR,,, -r,,IDUrządzenia,DeviceID,,,4022,80,,,ULR,,, -r,,CzasPracy,OperatingTime,,,4022,83,,,ULR,,, -r,,WersjaOprogramowania,SoftwareVersionBaseModule,,,4022,f0,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionBaseModule,,,4022,f1,,,STR:4,,, -r,,WersjaOprogramowania,SoftwareVersionUIFModule,,,4022,f2,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionUIFModule,,,4022,f1,,,STR:4,,, -r,,WersjaJęzyka,LanguageVersionUIFModule,,,4022,f4,,,STR:13,,, -r,,WersjaObrazu,ImageVersionUIFModule,,,4022,f5,,,STR:13,,, -r,,WersjaOprogramowania,SoftwareVersionExtensionModule,,,4022,f6,,,STR:13,,, -r,,WersjaSprzętu,HardwareVersionExtensionModule,,,4022,f7,,,STR:4,,, - -## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) -w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] -r,,PrzepływPowietrzaTryb0,FlowMode0,,,4050,21,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:0],Max,,SIR,,m³/h,[max:50],Step,,SIR,,m³/h,[step:50],Default,,SIR,,m³/h,[default:50] -w,,PrzepływPowietrzaTryb1,FlowMode1,,,4080,01,,,SIR,,m³/h,[min:50;max:400;step:5;default:100] -r,,PrzepływPowietrzaTryb1,FlowMode1,,,4050,01,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:100] -w,,PrzepływPowietrzaTryb2,FlowMode2,,,4080,02,,,SIR,,m³/h,[min:50;max:400;step:5;default:200] -r,,PrzepływPowietrzaTryb2,FlowMode2,,,4050,02,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:200] -w,,PrzepływPowietrzaTryb3,FlowMode3,,,4080,03,,,SIR,,m³/h,[min:50;max:400;step:5;default:300] -r,,PrzepływPowietrzaTryb3,FlowMode3,,,4050,03,,,SIR,,m³/h,,Min,,SIR,,m³/h,[min:50],Max,,SIR,,m³/h,[max:400],Step,,SIR,,m³/h,[step:5],Default,,SIR,,m³/h,[default:300] -w,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4080,08,,,UIR,0=Not Permitted;1=Permitted,,[min:0;max:1;step:1;default:1] -r,,DopuszczalnaNierównowagaPrzepływu,UnbalanceMode,,,4050,08,,,UIR,0=Not Permitted;1=Permitted,,,,,IGN:6,,,,Default,,UIR,0=Not Permitted;1=Permitted,,[default:1] - min/max/step fields of enum message omitted -w,,StałaNierównowaga,UnbalanceFlow,,,4080,09,,,UIR,10,%,[min:0;max:200;step:1;default:0] -r,,StałaNierównowaga,UnbalanceFlow,,,4050,09,,,UIR,10,%,,Min,,UIR,10,%,[min:0],Max,,UIR,10,%,[max:200],Step,,UIR,10,%,[step:1],Default,,UIR,10,%,[default:0] -w,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4080,4a,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,KorektaPrzepływuWlot,FlowOffsetInlet,,,4050,4a,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4080,4b,,,SIR,10,%,[min:-150;max:150;step:1;default:0] -r,,UchybPrzepływuWylot,FlowOffsetExhaust,,,4050,4b,,,SIR,10,%,,Min,,SIR,10,%,[min:-150],Max,,SIR,10,%,[max:150],Step,,SIR,10,%,[step:1],Default,,SIR,10,%,[default:0] -w,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4080,40,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:1] -r,,ŁącznikPozycjiDomyślnej,SwitchDefaultPos,,,4050,40,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted -w,,DaneDotByPassu,BypassMode,,,4080,1b,,,UIR,0=Auto;1=Closed;2=Open,,[min:0;max:2;step:1;default:0] -r,,DaneDotByPassu,BypassMode,,,4050,1b,,,UIR,0=Auto;1=Closed;2=Open,,,,,IGN:6,,,,Default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted -w,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4080,05,,,SIR,10,°C,[min:70;max:150;step:1;default:100] -r,,TemperaturaObejściaOdZewnątrz,BypassTempFromOutside,,,4050,05,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:150],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:100] -w,,HisteryzaByPassu,BypassTempHyst,,,4080,30,,,SIR,10,°C,[min:0;max:50;step:5;default:20] -r,,HisteryzaByPassu,BypassTempHyst,,,4050,30,,,SIR,10,°C,,Min,,SIR,10,°C,[min:0],Max,,SIR,10,°C,[max:50],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:20] -w,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4080,4c,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybWzmocnieniaObejścia,BypassBoostMode,,,4050,4c,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4080,4d,,,UIR,,,[min:0;max:3;step:1;default:3] -r,,UstawienieWstępnePrzepływuWzmocnieniaObejścia,BypassBoostFlowPreset,,,4050,4d,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:3] -w,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4080,4e,,,SIR,10,°C,[min:-15;max:15;step:1;default:0] -r,,TemperaturaUruchomieniaTrybuMrozowego,FrostStartTemperature,,,4050,4e,,,SIR,10,°C,,Min,,SIR,10,°C,[min:-15],Max,,SIR,10,°C,[max:15],Step,,SIR,10,°C,[step:1],Default,,SIR,10,°C,[default:0] -w,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4080,62,,,SIR,10,°C,[min:70;max:220;step:5;default:100] -r,,MinimalnaTemperaturaWlotowa,FrostMinInletTemperature,,,4050,62,,,SIR,10,°C,,Min,,SIR,10,°C,[min:70],Max,,SIR,10,°C,[max:220],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:100] -w,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4080,4f,,,UIR,,Day,[min:1;max:365;step:1;default:365] -r,,DniEksploatacjiFiltraDoAlarmu,FilterDaysBeforeWarning,,,4050,4f,,,UIR,,Day,,Min,,UIR,,Day,[min:1],Max,,UIR,,Day,[max:365],Step,,UIR,,Day,[step:1],Default,,UIR,,Day,[default:365] -w,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4080,0a,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyWstępnej,ExternalPreHeaterMode,,,4050,0a,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4080,1e,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,TrybZewnętrznejNagrzewnicyKońcowej,ExternalPostHeaterMode,,,4050,1e,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4080,0b,,,SIR,10,°C,[min:150;max:300;step:5;default:210] -r,,TemperaturaNagrzewnicyWtórnej,PostheaterTemp,,,4050,0b,,,SIR,10,°C,,Min,,SIR,10,°C,[min:150],Max,,SIR,10,°C,[max:300],Step,,SIR,10,°C,[step:5],Default,,SIR,10,°C,[default:210] -w,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4080,3c,,,UIR,0=no;1=yes,,[min:0;max:1;step:1;default:0] -r,,CzujnikiCO2Uaktywnione,CO2SensorsActivated,,,4050,3c,,,UIR,0=no;1=yes,,,,,IGN:6,,,,Default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted -w,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4080,34,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika1CO2,CO2Sensor1LowerLimit,,,4050,34,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4080,35,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika1CO2,CO2Sensor1UpperLimit,,,4050,35,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4080,36,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika2CO2,CO2Sensor2LowerLimit,,,4050,36,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4080,37,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika2CO2,CO2Sensor2UpperLimit,,,4050,37,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4080,38,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika3CO2,CO2Sensor3LowerLimit,,,4050,38,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4080,39,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika3CO2,CO2Sensor3UpperLimit,,,4050,39,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4080,3a,,,UIR,,ppm,[min:400;max:2000;step:25;default:400] -r,,LimitDolnyCzujnika4CO2,CO2Sensor4LowerLimit,,,4050,3a,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:400] -w,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4080,3b,,,UIR,,ppm,[min:400;max:2000;step:25;default:1200] -r,,LimitGórnyCzujnika4CO2,CO2Sensor4UpperLimit,,,4050,3b,,,UIR,,ppm,,Min,,UIR,,ppm,[min:400],Max,,UIR,,ppm,[max:2000],Step,,UIR,,ppm,[step:25],Default,,UIR,,ppm,[default:1200] -w,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4080,32,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,CzujnikWilgotnościWzględnejObecny,RHTSensorPresent,,,4050,32,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4080,33,,,SIR,,,[min:-2;max:2;step:1;default:0] -r,,CzułośćCzujnikaWilgotnościWzględnej,RHTSensorSensitivity,,,4050,33,,,SIR,,,,Min,,SIR,,,[min:-2],Max,,SIR,,,[max:2],Step,,SIR,,,[step:1],Default,,SIR,,,[default:0] -w,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4080,07,,,UIR,0=off;1=on,,[min:0;max:1;step:1;default:0] -r,,CentralneOgrzewanieOdzyskCiepła,CVWTWMode,,,4050,07,,,UIR,0=off;1=on,,,,,IGN:6,,,,Default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted -w,,TrybWyjściaSygnału,SignalOutputMode,,,4080,61,,,UIR,,,[min:0;max:3;step:1;default:0] -r,,TrybWyjściaSygnału,SignalOutputMode,,,4050,61,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:3],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanActivated,ExternalFanEnable,,,4080,a5,,,UIR,,,[min:0;max:1;step:1;default:0] -r,,ExtFanActivated,ExternalFanEnable,,,4050,a5,,,UIR,,,,Min,,UIR,,,[min:0],Max,,UIR,,,[max:1],Step,,UIR,,,[step:1],Default,,UIR,,,[default:0] -w,,ExtFanMinimumVoltage,ExternalFanVmin,,,4080,a6,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMinimumVoltage,ExternalFanVmin,,,4050,a6,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] -w,,ExtFanMaximumVoltage,ExternalFanVmax,,,4080,a7,,,SIR,10,V,[min:0;max:100;step:1;default:10] -r,,ExtFanMaximumVoltage,ExternalFanVmax,,,4050,a7,,,SIR,10,V,,Min,,SIR,10,V,[min:0],Max,,SIR,10,V,[max:100],Step,,SIR,10,V,[step:1],Default,,SIR,10,V,[default:10] diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv index dc8223ce..51938d1b 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Konfigurationsparameter ## (Werte in Klammern neben dem Feld sind Definitionen dieser Feldwerte aus dem Brink Service Tool.) w,,LuftmengeStufe0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv index 81b1badf..871f68a4 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Konfigurationsparameter ## (Werte in Klammern neben dem Feld sind Definitionen dieser Feldwerte aus dem Brink Service Tool.) w,,LuftmengeStufe0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv index dfe177be..09a893be 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv index 5e31a82d..c600b922 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF250.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv index f2b55245..565d57c0 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Konfigurationsparameter ## (Werte in Klammern neben dem Feld sind Definitionen dieser Feldwerte aus dem Brink Service Tool.) w,,LuftmengeStufe0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv index e55209c4..3e63a897 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Konfigurationsparameter ## (Werte in Klammern neben dem Feld sind Definitionen dieser Feldwerte aus dem Brink Service Tool.) w,,LuftmengeStufe0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv index fe9afb19..c33ce039 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv index e409e58d..7c79e641 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLF350.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv index c3a9c11f..3652013d 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv index c3a9c11f..3652013d 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10603.10603.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv index dc398db8..caa0687e 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv index dc398db8..caa0687e 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv index 1c6d012c..060b6bb7 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv index 1c6d012c..060b6bb7 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv index 745e23bd..2ec9bd2b 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv index 745e23bd..2ec9bd2b 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv index 25d09ec0..86425b32 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv index 27c5919a..87a1e9ea 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv index eec1b598..18866016 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv index f39d743e..a8b0f656 100644 --- a/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/CWLTower300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv index 01380a23..e0032b43 100644 --- a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv index 01380a23..e0032b43 100644 --- a/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/ConstantRPM400.10505.99999.plus.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv index 6be61fc2..7d985b69 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv index bb97f911..b264f709 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10101.10700.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv index b6831716..98a7a3cd 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv index d9a77935..52aaf776 100644 --- a/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/DecentralAir70.10701.99999.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv index 404f2d03..df8904fc 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Elanstatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv index 404f2d03..df8904fc 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan10.10103.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Elanstatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv index 71e6454e..388a7c47 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Elanstatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv index eb3f0ffa..28a13fd3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Elan4.10104.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Elanstatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv index bbac30be..5b1f9f11 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv index af4b64ff..da98d4cf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10503.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv index f72e0e00..d624c0d6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv index 5d7cfc58..11286378 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv index b9a98f6d..db3f4890 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv index f1a5dfc2..c312cee0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv index c838e95f..00223c91 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv index bd45c36b..ac49a840 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv index 47e8b464..2d2d5667 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv index 233d7006..5591761d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv index 25dd89db..72b99389 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv index 8206d2ca..94dc1bcb 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent180.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv index 54a09fa9..20f26cbe 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv index 465c0609..b18e8dd7 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv index d29c7e6a..a5be9542 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv index 7a6cb380..1ed2c007 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv index ad4d2223..0748955c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv index 7be5bf08..0742e5d2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv index 311521d8..578732f1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv index 968b3d50..6bb09ec4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv index 03d111c9..b05631af 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv index 7f3092fc..4f82edcb 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv index 9f1c0982..22434107 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv index 78230433..dc45dd9d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv index 071c4a03..81b5cd7a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv index 07f4f23a..e6c10303 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv index 34f068d0..11b25337 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv index 1180a3cc..c938395c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv index 56308535..e42575f8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv index af0c6342..ef833ebe 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv index f9c9191b..76986453 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv index 25468983..75d8cfd2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv index af37991b..a4b4ed53 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv index 95baaf79..62f2686f 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv index 5bac56cf..5653e5c2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv index 383a7adc..9d73d498 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv index b51f0ff4..1fbc102e 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv index 20b337c1..e9a59c27 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent400.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv index 3929b787..0015c001 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv index 3d65901f..9cb1e062 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv index ddcfbead..1ef0e322 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv index 5a9c0fa1..a8e42413 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv index b664aa74..903abf6a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv index a771019e..0019803b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv index 0eea47a0..9629d782 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv index 9cc44bc5..9120411b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv index 2db71b4b..dc849866 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv index 5612397c..5f67f363 100644 --- a/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Excellent450.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv index 001d11e0..d0696836 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair200.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv index 17f54aa2..f24e6380 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair225.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv index 0cc82a52..75c31eb1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair300.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv index 43e54a3b..1b40b222 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair300.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv index 4a7e311c..de4685b9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair325.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv index 2bef3421..ebf17887 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair325.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv index b971f835..98a517e6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair400.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv index db9ad47a..08e9a2ed 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair400.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv index abbe2868..29ae22b0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair450.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv index 7792f5e5..6da9d178 100644 --- a/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Flair600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.0.10101.csv index d2de6f6a..b659f322 100644 --- a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.0.10101.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10102.10102.csv index 0dadbe24..68b1e0e7 100644 --- a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10102.10102.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10103.99999.csv index a7a975a3..23e21a18 100644 --- a/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/MultiRoomCtrlT01.10103.99999.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv index d0b3d4c2..99634975 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv index d0b3d4c2..99634975 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10703.10706.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv index 9c17fcab..aa65c2c1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv index 57f64859..c2e01483 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv index 367a88cc..9f644f56 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv index 367a88cc..9f644f56 100644 --- a/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Nather300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv index 31fb7cc1..80b28729 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv index bbca524a..86146680 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv index fa3b6a42..941583ca 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv index 3df0cb99..58db1634 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv index 2b940298..bc047907 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv index a033a842..051d4aff 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv index de10f40c..7e9301a2 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv index 2a250739..ce8077e3 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv index 8fd43806..c5b9218f 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv index 139d8eae..751bf3b0 100644 --- a/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/RenoventElan300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv index 769cab03..81b28689 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv index 7c2de0b6..8fad9bb8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10504.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv index 408590a9..e430c4e4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv index 43daaa6d..e43b9b66 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv index ef9e6605..3b0524d1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv index d3d61f17..13715dd1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv index e2930b2f..4cade537 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv index f0ec0159..6412efb9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv index efb9c0c6..36846fbe 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv index 123215f4..32a11690 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv index 8a33d9be..146bba2d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv index 97105fab..dfd8d792 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky150.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv index 81dedcbd..d2d5e4f2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv index 41bbf20e..07d628f3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10702.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv index f422b2e2..57e8c7d9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv index e5e2341b..cb1d7fda 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv index 25316c03..7e390df4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv index e51f55d4..4e4476f5 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky200.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv index 19486a69..000efe1d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv index f58f3681..3663cbcf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv index 54c28dcc..fd1d2ea3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv index 3d83408e..501244e4 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv index 4cdca5aa..40dc366c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv index a4e58f92..867ed678 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv index e25b62e0..1f884361 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv index 40d9aa86..a9f151cb 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv index ca297c05..7a84b220 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv index aff9105c..7c276020 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv index ef449450..3378c06a 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv index 92c11e1d..00f7ca93 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv index d4d20cf2..40de2df2 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv index 1d3b0b80..c66c1c7d 100644 --- a/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Sky300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/de/ValveT01.0.99999.csv index a0363108..9f223cd4 100644 --- a/ebusd-configuration-unknown-slave-address/de/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/ValveT01.0.99999.csv @@ -17,9 +17,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv index 1eaa464e..210527f1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv index 1eaa464e..210527f1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10104.10104.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv index f3fbdf54..227b1d83 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv index f3fbdf54..227b1d83 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10105.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv index 9a783801..76394b5b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv index 9a783801..76394b5b 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent200W.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv index 2636243d..230c3088 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv index 42d29d14..e6c48ff6 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv index 8e4b26a3..633aa960 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv index 8b690043..e457b7d1 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300C.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv index 684c47ee..4952abae 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv index f8e66ea2..3efb9ab9 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv index 0e3c1933..c3119227 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv index 8750e881..b00b5293 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W300.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv index 5c458c6f..51a9dcfd 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv index d08c798b..b95b8960 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv index fc197ad4..0e73f8d3 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv index a77dd050..00852a21 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300W400.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,Ventilatorbetrieb,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv index 967bb707..9cef60b8 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10101.10109.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv index b13bb333..9dcae159 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10110.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv index 8b2e8e34..dd2f2988 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA225.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv index ac0d389c..1e585b70 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SA600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv index 8458a16e..9438a6bf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv index c24bda5f..44e0cabf 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC325.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv index c8e69301..e5b58d0c 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv index 2e162af4..92a1c0d0 100644 --- a/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/de/Vitovent300WH32SC400.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## ALLGEMEINE HRU BEFEHLE ## (WTWCommands.cs - Einige davon sind möglicherweise nicht für dieses Gerät anwendbar, mit Vorsicht verwenden) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RücksetzenAufWerkseinstellung,FactoryReset,,,40ff,466163746f72795265736574 +w,,Fehlerliste,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,GespeicherteFehler,RequestErrorList,,,4090,,,,HEX:18,,, +w,,Ventilatorbetrieb,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filterverwendung1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterverwendungTage,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filterverwendung1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Betriebsdauer,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,Gesamtdurchsatz1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktueller Zustand und Sensoren ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv index 1fffa7b9..79022276 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) w,,AirFlowRateMode0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv index 047063a1..dd66ba4d 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) w,,AirFlowRateMode0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv index b3b81b69..076b7063 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv index 5013d6a3..cbfbcc15 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF250.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv index 882fa3ac..7abced18 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) w,,AirFlowRateMode0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv index c2f6494d..899cb7f8 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuration parameters ## (values in brackets next to field are definitions of those fields values from Brink Service Tool.) w,,AirFlowRateMode0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv index da09df4b..a56d88d1 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv index 58e700ba..38a91982 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLF350.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv index 5295c3d5..bced794b 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv index 5295c3d5..bced794b 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10603.10603.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv index b2244aa5..31d3eeed 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv index b2244aa5..31d3eeed 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv index 9bdcb07d..03f6967a 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv index 9bdcb07d..03f6967a 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv index d05349ea..a413a0be 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv index d05349ea..a413a0be 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv index 869c0023..50334122 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv index a3b0c404..213979f0 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv index b48d0f85..f6fc1f88 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv index eb035c18..d66f5439 100644 --- a/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/CWLTower300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv index 5076f023..897b4537 100644 --- a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv index 5076f023..897b4537 100644 --- a/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/ConstantRPM400.10505.99999.plus.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv index a398ed50..d39db0b2 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv index 5f5b9db4..fb3dd5f8 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10101.10700.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv index c8ed642b..c60b7030 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv index 85401823..3c8db4bd 100644 --- a/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/DecentralAir70.10701.99999.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv index f02b6926..fbe46608 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv index f02b6926..fbe46608 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan10.10103.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv index 522dcb66..47a07989 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv index 2dabb15c..2209675f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Elan4.10104.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv index ca2b9824..921d1d37 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv index 159b1aeb..338eac97 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10503.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv index df569299..3aa861dc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv index 89a06d53..b96255e6 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv index 813699a5..0e6d9180 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv index ff762d30..2bff42e6 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv index 1c64cc2c..e7718664 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv index b50ed59d..ae632b14 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv index aae611ca..2a3bad1e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv index f6ba08f5..9afd8511 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv index 4464318d..56ebcf0e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv index 894e77c8..74eb91bf 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent180.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv index 8219afc1..ab83cf48 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv index 584ecb27..4641ee57 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv index cf046b90..78887966 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv index 98bbd65d..e443b56e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv index fe3bc944..14d43917 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv index 0385bf05..25b3a5a4 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv index bc6a7af9..220cd2c9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv index 855e1181..19b4f9ce 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv index 2d17de49..372b29d3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv index 383c183a..27ed2821 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv index 72fffca5..742a4725 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv index 6e4ded27..7c551502 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv index 735ddfb1..99c05f8f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv index a321aef6..ebdb765a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv index c62b9be9..6dbfbd93 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv index d011fd28..2b5090cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv index 56cb2a7a..77f476b3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv index 3c19ee59..07c83412 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv index ca7959d1..0c79d919 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv index 748b75f2..b3dea87f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv index 524ccf10..78e9572c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv index 59bce116..c9766338 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv index 3c6e730e..53e5125a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv index 59dbb885..7f22e47d 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv index 112f2da9..b62fd36d 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv index 11d473f9..c84a629c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent400.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv index 694d49ca..03dec12a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv index e1fea7d6..97ad6426 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv index c00bc90d..701cb2e4 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv index 7a62e88e..de3e6ac2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv index 57a64984..42e0ca61 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv index 1ce05ce2..49ce4da2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv index eaa35d6a..99a401a4 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv index b7e1f116..4bac738f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv index 583e41c6..c430a044 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv index 713938fe..24c541d8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Excellent450.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv index 6fff223a..2ac02697 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair200.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv index ecf2968f..bf4900ed 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair225.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv index cbcb9e36..80f4c679 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair300.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv index e598f8a8..1a6bc586 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair300.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv index a346cd7b..68fc0837 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair325.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv index a6d90af5..0decccea 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair325.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv index 91ffa280..704388aa 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair400.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv index 7531326f..ec1f9e70 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair400.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv index 66f89e18..b4b04800 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair450.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv index 7b9f780b..2b3709cc 100644 --- a/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Flair600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.0.10101.csv index 38b37259..089604ec 100644 --- a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.0.10101.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10102.10102.csv index da51e2b1..c7f78361 100644 --- a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10102.10102.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10103.99999.csv index d19e5656..b03d99db 100644 --- a/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/MultiRoomCtrlT01.10103.99999.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv index 0a3b3e4f..942d162c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv index 0a3b3e4f..942d162c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10703.10706.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv index 5abcf969..4354fd59 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv index 832d00f9..769049e0 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv index 4f9cb04a..a53a054b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv index 4f9cb04a..a53a054b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Nather300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv index a20ba854..1c403688 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv index e88ae376..fc761f35 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv index 64d06b60..abda01e7 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv index d4cd2d93..f179971f 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv index 6ac53c77..a0b4aa1d 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv index 5c3195e2..653ab0ea 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv index 409a2164..fd2191dd 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv index 22407e33..87459dd9 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv index 86cace86..b8cdbc23 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv index bf798ceb..0f1ef33f 100644 --- a/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/RenoventElan300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv index 833852cd..612a17b6 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv index a4f2a27f..3ebc3de3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10504.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv index 314736e9..1cedf57c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv index ec4ecab8..811fa203 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv index 39bdf655..a11a71fe 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv index b898ebcc..666769ab 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv index 3cb1404c..53890a56 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv index 6150d29c..e7d1e878 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv index 5d4afe01..ccfa790e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv index 00297f97..082542bb 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv index ce818962..786c186e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv index b6561032..d3176f96 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky150.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv index 16cad3d0..5df429f1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv index e4674ebe..81199bee 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10702.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv index 9c4c1fe9..6f87088c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv index 27b5a9fa..cd139ed8 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv index e50f8db3..f47a183b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv index e00c8f1c..d0d7d2ec 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky200.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv index 442be35c..66430e1f 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv index 8190dd5b..be77a81c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv index adbe209b..b290e023 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv index 63f7151a..e36ac6ee 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv index d639cbae..76deefe2 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv index ae776c97..8a3f0518 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv index 82dea518..bd781f5e 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv index 3881d33d..d73a87df 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv index a9251bef..3447da48 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv index 2af65b7a..2bba5313 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv index 6854992a..aebee9da 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv index 92d310ba..202949b1 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv index e0fc7d7a..f8e9f706 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv index 27731cb4..2595834a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Sky300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/en/ValveT01.0.99999.csv index 6ce0d9f4..bde3f069 100644 --- a/ebusd-configuration-unknown-slave-address/en/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/ValveT01.0.99999.csv @@ -19,9 +19,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv index 88ea83b9..a3897419 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv index 88ea83b9..a3897419 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10104.10104.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv index 1f9e040b..25b878b9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv index 1f9e040b..25b878b9 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10105.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv index 5cb8fe94..63821636 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv index 5cb8fe94..63821636 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent200W.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv index 15ced5ea..536dc0d3 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv index e3c0f117..4363f99b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv index c9fad190..6baa7749 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv index 6b81e272..330808bd 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300C.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv index 8c68861a..23307041 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv index 2c5a5cc1..658ab3ea 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv index 43f38d29..652dd038 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv index bdfb90dd..3ee22148 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W300.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv index 778f1a18..e57ece5c 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv index 10f72dea..5064968a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv index 6c2c30ac..23a8882a 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv index 3859cb4c..7d77ab8d 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300W400.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,FanMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv index bc964620..1b9ba84b 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10101.10109.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv index 04bf99f3..4a6b9f92 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10110.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv index 55f85d70..cd9915f5 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA225.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv index ed792faa..ec7ee360 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SA600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv index e72ee949..32f5753d 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv index 4880eccb..7f7ed9ed 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC325.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv index c7cd954e..a455b274 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv index dc5598de..6acd9578 100644 --- a/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/en/Vitovent300WH32SC400.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMMON HRU COMMANDS ## (WTWCommands.cs - Some of them might not be applicable for this device, use with caution) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FactoryReset,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,ErrorHistory,RequestErrorList,,,4090,,,,HEX:18,,, +w,,FanMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FilterUsage1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FilterUsageDays,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,FilterUsage1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,OperatingTime,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotalFlow1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Curent state and sensors ## r,,SoftwareVersion,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv index 658303d7..642ddb80 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parámetros de configuración ## (los valores entre paréntesis junto al campo son definiciones de esos valores de campo del Herramienta de Servicio Brink.) w,,ModoDeVelocidadDeFlujoDeAire0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv index ad863649..a79e5cd7 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parámetros de configuración ## (los valores entre paréntesis junto al campo son definiciones de esos valores de campo del Herramienta de Servicio Brink.) w,,ModoDeVelocidadDeFlujoDeAire0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv index be8ffcab..2a34897f 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv index 6369560b..0da848a0 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF250.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv index 4f3a5545..bb1249fa 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parámetros de configuración ## (los valores entre paréntesis junto al campo son definiciones de esos valores de campo del Herramienta de Servicio Brink.) w,,ModoDeVelocidadDeFlujoDeAire0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv index 1c2c7871..08fac2d4 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parámetros de configuración ## (los valores entre paréntesis junto al campo son definiciones de esos valores de campo del Herramienta de Servicio Brink.) w,,ModoDeVelocidadDeFlujoDeAire0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv index 3eaaf00f..811b2657 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv index 6ed95895..86f7c486 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLF350.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv index 96be539b..bcf82a89 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv index 96be539b..bcf82a89 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10603.10603.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv index b5d568b6..9b4017d9 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv index b5d568b6..9b4017d9 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv index 5b921da5..4b523b93 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv index 5b921da5..4b523b93 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv index ef7797ad..ebf2bd0c 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv index ef7797ad..ebf2bd0c 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv index 485620dc..91794e5c 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv index 30e3ec3a..130f494d 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv index 466005ac..d17b34d8 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv index eb58726f..1d9ebacb 100644 --- a/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/CWLTower300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv index 0c6be6fe..52db763c 100644 --- a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv index 0c6be6fe..52db763c 100644 --- a/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/ConstantRPM400.10505.99999.plus.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv index 147bdcf7..46c4b7c3 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv index a4245249..c1e4d96c 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10101.10700.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv index f596cb32..27849fce 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv index f2efd7a3..4e0aec86 100644 --- a/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/DecentralAir70.10701.99999.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv index 71611736..6474e11b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,EstadoDeElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv index 71611736..6474e11b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan10.10103.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,EstadoDeElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv index 4335005e..9f3f8b59 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,EstadoDeElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv index bdcfb25f..af93d186 100644 --- a/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Elan4.10104.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,EstadoDeElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv index 51612622..a95aa172 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv index 03e7a538..b0eb0661 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10503.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv index e9f95e72..109bfe26 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv index 251805cd..966dcd82 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv index c9f0221a..1ab104b0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv index a15f699f..e1b56248 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv index 3f6241e4..87d4f6ac 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv index 87199024..9d7ffe19 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv index 5419420e..ca497f7a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv index 6696c4ee..b0293f6a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv index bd3b3bbb..1b6fd746 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv index 8250a225..019040be 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent180.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv index fdb6042b..e1862c3f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv index 4218795e..c746161c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv index 84ca3e60..d622cbed 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv index f8b95401..e0c2cc53 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv index d79815b7..358e3f70 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv index 021695c4..99c0dd4b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv index dc302fc4..c2ccefd1 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv index 99fd79c8..58116e5d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv index 5b4854c4..0b2dd13b 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv index f86d4b7d..7100c95c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv index cf878bb4..295844b9 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv index aa0ed7ab..17142f59 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv index dea5ce74..e9257cb2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv index fd4f24b0..ad52e7f1 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv index 739fed94..b68caa37 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv index 19e60aab..53ff1619 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv index 0ba4c195..19234f00 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv index 6d8a94cc..d621da61 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv index d5832636..28b37349 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv index 00695341..8a34b7e0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv index dcb76be0..734d2e97 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv index 3aceed95..d0420d7e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv index e42cced3..9db9c776 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv index d8927ab1..ba03249a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv index bbaa6ee4..ab7cecf9 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv index 1fc4bd78..80893d9c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent400.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv index 2aefc0ea..1e92769e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv index 3b413321..19444a0d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv index 84d8c9d1..a59ce2c6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv index dca2d361..00048e4e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv index 9874cb16..52d744e2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv index 47e92c2d..07bc85f2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv index 03088f50..d90b2b3c 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv index b7396c66..acaaf6a7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv index 4e8f9564..53d73387 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv index 433d8671..f00f9bd2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Excellent450.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv index 6e97ebf9..3de40957 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair200.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv index d88b8ec2..70fa4b95 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair225.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv index 81a43757..a133b588 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair300.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv index 068de3ab..dd43cc90 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair300.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv index de67eedb..f13f1cb3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair325.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv index 40fbc2c5..55d675e2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair325.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv index 2503edb2..79f15e5a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair400.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv index 500ae618..3af702ef 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair400.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv index 220e93c7..1b931304 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair450.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv index dca74b09..691feadf 100644 --- a/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Flair600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.0.10101.csv index d33f34c9..c97097bb 100644 --- a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.0.10101.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10102.10102.csv index 767128ce..ee6fa163 100644 --- a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10102.10102.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10103.99999.csv index a506266e..1c086f46 100644 --- a/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/MultiRoomCtrlT01.10103.99999.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv index 90b7fb86..076f70cc 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv index 90b7fb86..076f70cc 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10703.10706.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv index 01d121ee..34aac00f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv index bce55625..e55d6d04 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv index 45cbce92..d19684e6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv index 45cbce92..d19684e6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Nather300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv index bc2f1127..53c17e7d 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv index 8861148f..5fcefb9c 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv index daf021f5..bf0d84da 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv index 9902a4ab..68536212 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv index b65d9e83..49557521 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv index 07321ccc..452dc2be 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv index 7033f763..d0e4df89 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv index a41fc241..3e9346af 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv index 05ad10c3..efd27433 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv index 52765e40..0bc20505 100644 --- a/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/RenoventElan300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv index 782b810a..749222b3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv index 64353575..554972b5 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10504.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv index 133d5457..95e864d4 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv index fb615d00..9927e145 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv index a4072a18..5fa4ad50 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv index 29af702e..891b7321 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv index ca65303e..07eb3e86 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv index 725e23b7..aff0f1c3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv index 554b714a..d127cca1 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv index aa983b6a..c1f28d51 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv index 062cf9d3..2d5767c7 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv index 21d32ebc..4e3ead68 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky150.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv index f4c18af7..2422ef79 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv index bf3a916c..539084c3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10702.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv index a50d4cf7..2e21d5e4 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv index 24d40107..916b1f6f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv index 3d91dbd0..067cefff 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv index 14ddcd53..9c32aba3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky200.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv index 698b3305..9c3e18db 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv index 082b4595..6ce1899f 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv index de2ede7d..536ce792 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv index 2e47c792..152468b2 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv index a7a98fcf..9b8340d9 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv index 67be3260..9d7646fe 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv index 2e126270..a7519b48 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv index fa311fe8..96a130aa 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv index aee4efa1..3b40011e 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv index 79dfc0fa..55795813 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv index 91f02f31..6de51327 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv index 5403716d..29901611 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv index 71fcb961..f7e0b306 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv index e9bccdf7..748c25a3 100644 --- a/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Sky300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/es/ValveT01.0.99999.csv index 0bdcf4e2..049c22c2 100644 --- a/ebusd-configuration-unknown-slave-address/es/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/ValveT01.0.99999.csv @@ -17,9 +17,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv index ca42da55..ac5778cb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv index ca42da55..ac5778cb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10104.10104.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv index a0ab4f08..b161ef63 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv index a0ab4f08..b161ef63 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10105.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv index 09404b14..db556942 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv index 09404b14..db556942 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent200W.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv index af6b7ee2..6935fdb6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv index fcc57eec..a62115ad 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv index cc236f91..8fc0c7ac 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv index 9135aebc..c3afa819 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300C.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv index 2c9fff39..50e33975 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv index 9668182f..137e81f0 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv index 5f8834bb..f9f744fb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv index 54c5b386..eda48833 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W300.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv index a355efe2..e17d83d6 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv index 65429952..8649d172 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv index 452dae45..952f101d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv index d64909f4..837dd318 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300W400.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,ModoDeVentilador,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv index e78d088f..2bea34cb 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10101.10109.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv index bdcdeddc..c83402ae 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10110.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv index 99dc2c49..125ba946 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA225.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv index 393d3185..ad0a772a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SA600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv index 5d33ee25..3abc458d 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv index 111d98fb..78789896 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC325.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv index 1360679d..d2ccdbde 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv index 4f4e6a0d..1c36602a 100644 --- a/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/es/Vitovent300WH32SC400.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMANDOS HRU COMUNES ## (WTWCommands.cs - Algunos de ellos pueden no ser aplicables para este dispositivo, usar con precaución) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RestablecimientoDeLosAjustesDeFábrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,RestablecerNotificaciones,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistorialDeErrores,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModoDeVentilador,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UsoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UsoDelFiltroDías,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UsoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TiempoDeFuncionamiento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlujoTotal1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Estado actual y sensores ## r,,VersiónDeSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv index f8bfb034..e29871ee 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Paramètres de configuration ## (les valeurs entre parenthèses à côté du champ sont des définitions de ces valeurs de champ du Brink Service Tool.) w,,DébitDAirPosition0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv index d8844597..94d61bf0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Paramètres de configuration ## (les valeurs entre parenthèses à côté du champ sont des définitions de ces valeurs de champ du Brink Service Tool.) w,,DébitDAirPosition0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv index 8610843d..d3bd9f56 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv index a27fa8bc..a24c8d8c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF250.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv index 56ee0cbe..056521ba 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Paramètres de configuration ## (les valeurs entre parenthèses à côté du champ sont des définitions de ces valeurs de champ du Brink Service Tool.) w,,DébitDAirPosition0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv index 5baa46d0..2c2b6481 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Paramètres de configuration ## (les valeurs entre parenthèses à côté du champ sont des définitions de ces valeurs de champ du Brink Service Tool.) w,,DébitDAirPosition0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv index 18487e20..62fb721d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv index ef8a80b0..72c80d94 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLF350.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv index 35ddd43a..e2a754f6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv index 35ddd43a..e2a754f6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10603.10603.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv index 4b977436..0c6a1eb4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv index 4b977436..0c6a1eb4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv index db105164..e1427627 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv index db105164..e1427627 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv index 860eaeba..154c4c90 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv index 860eaeba..154c4c90 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv index 0275c6b1..f687a26c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv index 7bf42dca..33801764 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv index b3f10709..91b6b8bf 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv index 5726aa5e..eb1b8e59 100644 --- a/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/CWLTower300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv index 453c9353..bcc8938c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv index 453c9353..bcc8938c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/ConstantRPM400.10505.99999.plus.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv index e7b4098b..1fcfa337 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv index 5867dd36..c3b5d9a6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10101.10700.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv index c82f1235..6abb94aa 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv index 6d029fb4..8b536f3f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/DecentralAir70.10701.99999.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv index 380f3a86..d0e0b2be 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ÉtatElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv index 380f3a86..d0e0b2be 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan10.10103.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ÉtatElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv index 242ded4c..35b0e2bc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ÉtatElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv index dba4e4ba..c45fd870 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Elan4.10104.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ÉtatElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv index 4ed598a3..e1afa2de 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv index 2073450a..b1db15cc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10503.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv index 80b83a5b..3439fdd3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv index 8cdf46de..2070187f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv index dc844b51..3f347366 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv index 2447bfec..293f849f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv index 744aa20a..717b863b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv index 4c550434..b902e30b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv index b3eaa8a7..1c3f5e7f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv index 4d9ddc7e..e3fb88b5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv index e728b7a8..1785f3c1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv index b6b9aa56..8c5adcf5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent180.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv index 359f1a7c..c5689627 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv index 7670f3f0..013da8b8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv index 383b62ca..f04c4c69 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv index 866669f6..78ac8646 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv index 35ed8ba3..87356a25 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv index 8890f019..86951a0c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv index 97952ec6..71a1e4c0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv index 611b4ef0..ea7a691d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv index 5578226a..5e84e436 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv index c50fa624..73ba6670 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv index bb85cefe..5073bfea 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv index 321d3bcf..e63c4cbb 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv index 7f123ad1..fe6cf1f7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv index 38557711..ec7c08a9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv index 8343f75c..9169c315 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv index c6820bb5..fda17976 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv index 8b79f1ca..a28d0940 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv index 8b105335..faa64474 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv index b85e9f41..a48b6efe 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv index 81e1a9e3..cad3eca0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv index f7adf2ec..ed083008 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv index d1cadc81..c32fefb3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv index b0946c73..d4761b5b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv index a6f42b75..f9309b0d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv index 815f7222..ffc89040 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv index 5b43477a..c5850f54 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent400.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv index 2597e32e..bdcc517a 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv index ed21491b..5f21bc87 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv index 5bf3749a..c0d50705 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv index 5df5afbf..4c029bf3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv index e086a17e..3631e2d6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv index 4000884f..e66d27f9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv index 0ffd8b44..7ed72196 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv index 031e028e..709b0c10 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv index c174f55f..f5d1f615 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv index 0ac457eb..daeba1d6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Excellent450.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv index b3c4cb7b..470dfe9c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair200.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv index 45c81193..2c1e590c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair225.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv index b6bbce0a..1d2ea542 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair300.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv index 4eee9225..e3c04a47 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair300.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv index 2c267c1e..ac6fd033 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair325.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv index 779332f8..5296265c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair325.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv index 71ed7940..1ae5667b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair400.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv index 9275857c..10fd95ca 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair400.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv index 4642052a..08f30b69 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair450.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv index 0c3a31f3..05b7bc96 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Flair600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.0.10101.csv index 0b1dfb5b..57868366 100644 --- a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.0.10101.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10102.10102.csv index e518403b..2fa56214 100644 --- a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10102.10102.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10103.99999.csv index d240a2d3..808751dd 100644 --- a/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/MultiRoomCtrlT01.10103.99999.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv index f679922f..2cf0f117 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv index f679922f..2cf0f117 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10703.10706.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv index a7bd3628..59558e34 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv index 69e093c6..7f5a4a3f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv index 23622029..8efe78e7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv index 23622029..8efe78e7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Nather300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv index 75468277..3852be1f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv index 4fba3236..871442ef 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv index 2cfa92e3..89932f9e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv index 0ba74282..4ce1a965 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv index ecc1f529..6dbe3ed5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv index 64e64d03..f8b9d8f3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv index b5d9ada5..1cf7376e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv index fd28bcde..031917d3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv index ebe65479..d2de2701 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv index d1bfe27b..78903e2f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/RenoventElan300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv index 03237860..05ac37bd 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv index 252ab8f3..c91df9bb 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10504.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv index eb94dd85..a26338a9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv index a1900d89..a8ff687e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv index 2975a70d..b85fd9b7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv index 1e7c7776..69efbe89 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv index b66e8b32..6dc3b57d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv index ed501fba..1913d390 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv index 98a5913f..6d994e7d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv index 9b36934f..65380ff4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv index 635c9f26..c1fe81f4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv index fed17ef4..544a3a36 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky150.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv index 63f33140..e6e5bc0e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv index e7a8ef49..b94516e2 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10702.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv index 55b48cba..b98b00eb 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv index 57d1bf65..641e5b5b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv index cb0d9a34..ae7465bc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv index be9d4ec6..ce89fbf9 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky200.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv index 61922079..d078b4ac 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv index a5df9298..5b7cc7fb 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv index 9efa8767..f6ef1c90 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv index dcde3c67..4dd27f3b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv index e35d2458..f71b085d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv index a7fd8484..4102f133 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv index 3f0e9d0c..227f5ea3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv index ddec3275..231fef05 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv index 58411273..313f271c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv index f80946a3..d464eba7 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv index 727cf171..62cca3c1 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv index 7577954f..740fbd03 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv index f24651ca..d4aa5610 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv index c4d835fb..795993f4 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Sky300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/fr/ValveT01.0.99999.csv index a4f1ec89..cdb19d22 100644 --- a/ebusd-configuration-unknown-slave-address/fr/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/ValveT01.0.99999.csv @@ -17,9 +17,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv index c4ca46ad..65633ec8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv index c4ca46ad..65633ec8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10104.10104.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv index 0877f402..12835fd5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv index 0877f402..12835fd5 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10105.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv index e4fe70f7..4acc2dac 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv index e4fe70f7..4acc2dac 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent200W.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv index c9a53b92..3091f8dc 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv index 0374f4fe..8cdc9e3d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv index 5c983080..2d111957 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv index 60414c2d..1f957cd6 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300C.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv index f617b3b9..f3b58068 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv index bf5ec55e..7594c128 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv index 7a9781db..75a8f253 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv index f5f10af4..4ce9852c 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W300.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv index 73a96966..88f6f8c0 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv index 59baee37..246037c3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv index 2219fd96..c6138d03 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv index d5fd41ff..5ed2d3e8 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300W400.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,ModeVentilateur,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv index d70ab7d5..cfb83ff3 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10101.10109.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv index ea785ba7..745bf75b 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10110.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv index f806374d..4fbb51ce 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA225.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv index 79c4ef14..818d2a3e 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SA600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv index 04a4c625..b8b3f791 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv index 6882988d..bc295bdb 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC325.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv index 1aa96f26..fae6f05d 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv index 13bd1efe..121f328f 100644 --- a/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/fr/Vitovent300WH32SC400.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMMANDES HRU COMMUNES ## (WTWCommands.cs - Certaines d'entre elles peuvent ne pas être applicables pour cet appareil, à utiliser avec prudence) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,RéinitialiserRéglagesDUsine,FactoryReset,,,40ff,466163746f72795265736574 +w,,RéinitialiserLesNotifications,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriqueDesErreurs,RequestErrorList,,,4090,,,,HEX:18,,, +w,,ModeVentilateur,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilisationDuFiltre1000m³,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilisationDuFiltreJours,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilisationDuFiltre1000m³,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,TempsDeFonctionnement,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FluxTotal1000m³,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## État actuel et capteurs ## r,,VersionDuLogiciel,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv index a41aaf22..cdc5e324 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametri di configurazione ## (i valori tra parentesi accanto al campo sono definizioni di quei valori dei campi dallo Strumento di servizio Brink.) w,,PortataDAriaPosizione0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv index 4b66a63b..ef0d85a9 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametri di configurazione ## (i valori tra parentesi accanto al campo sono definizioni di quei valori dei campi dallo Strumento di servizio Brink.) w,,PortataDAriaPosizione0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv index 0349ce07..ccb08eca 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv index c57d7d81..504262ad 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF250.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv index 04628391..e46b8225 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametri di configurazione ## (i valori tra parentesi accanto al campo sono definizioni di quei valori dei campi dallo Strumento di servizio Brink.) w,,PortataDAriaPosizione0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv index 14e0efc5..a3424f36 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10806.10808.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametri di configurazione ## (i valori tra parentesi accanto al campo sono definizioni di quei valori dei campi dallo Strumento di servizio Brink.) w,,PortataDAriaPosizione0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv index 0df6e6e9..258e9eee 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv index df9ee5a0..9ecede70 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLF350.10809.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv index a5c62e77..ac87a9b1 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv index a5c62e77..ac87a9b1 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10603.10603.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv index 350eb5e7..1c242098 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv index 350eb5e7..1c242098 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv index 38bb7b97..58d9ac2c 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv index 38bb7b97..58d9ac2c 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv index e85a0fcb..8a0b9c9e 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv index e85a0fcb..8a0b9c9e 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv index 593fb3ad..9bf40d1f 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv index 1d56c9f9..37a9eab8 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv index a83c8e32..a91b0164 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv index bec5e6f3..fd067c7c 100644 --- a/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/CWLTower300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv index 0377e897..07f02ae6 100644 --- a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv index 0377e897..07f02ae6 100644 --- a/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/ConstantRPM400.10505.99999.plus.csv @@ -17,15 +17,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv index 40953f65..b68ab507 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv index 0b789c59..1d56b5b4 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10101.10700.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv index 82245ccd..5a233440 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv index 92ac1340..f448b2db 100644 --- a/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/DecentralAir70.10701.99999.plus.csv @@ -17,14 +17,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv index b87bb635..bca32fb5 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,StatoElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv index b87bb635..bca32fb5 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan10.10103.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,StatoElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv index cac703af..59eb0832 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,StatoElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv index d089d174..6e8f4ccf 100644 --- a/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Elan4.10104.99999.plus.csv @@ -17,15 +17,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,StatoElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv index 3c666649..fa852de3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv index ab818d1d..cddc4a7e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10503.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv index 874d962a..0d36d5ad 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv index cf149c49..72886e72 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv index f5cc4a0a..a9123e11 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv index b01d9229..1bb44014 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv index 7abb6ca3..478e5f04 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv index 4fd10dad..090663f7 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv index d8e6843b..eb799f4c 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv index ed90f647..e2b1cf8b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv index bb5f4d03..3483229d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv index d0414ec0..c5a0b7d1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent180.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv index 550a19ac..1007ef14 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv index ac46cf28..cbcb8aea 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv index 5a009986..3e7b19ce 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv index b86ff45f..cd5d2ef1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv index 9ce6da4c..0c7730b3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv index a77d0dee..ebe93597 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv index 4696f303..49ed6d01 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv index 86dcd224..a184cca1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv index 31d75e34..eb41029f 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv index a49c9ac3..80d5b4a7 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv index 289da1c1..2aeeb10d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv index d438cde4..7c5003aa 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv index 55db028b..a173ba58 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv index 42600893..2a22c8ab 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv index a7778e92..14f923b5 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv index 4371c46b..a1bbc75d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv index 9265a56f..56c0dcce 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv index c6a9b7c7..54836e3a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv index 66122ed4..818a6153 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv index 138d346a..b81bea0b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv index fbc3e1d3..23958dc1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv index 9a0973fc..31db9e73 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv index 7a079e04..9b5615f2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv index 8ee59c69..bd273536 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv index 06fcb94b..87b9c60a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv index 2a07fe33..1c5736b1 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent400.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv index b7b7f6c3..67bd142d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv index 28bfbd4f..dc156748 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv index 7922eb24..25bee469 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv index 6a199bde..3acd3e5e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv index c4cff004..96066dfc 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv index 3bf5678b..2858d9bd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv index 7a6794c7..5024115a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv index a3dce963..f239472f 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv index a15c3052..4db4a399 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv index 5ebfeece..cf1d4bfb 100644 --- a/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Excellent450.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv index 1686e3b2..ad464491 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair200.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv index 68365493..8c1467c4 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair225.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv index b060049a..6e369418 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair300.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv index 20930daa..a2358178 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair300.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv index 92f0776d..e9890226 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair325.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv index 08eada4f..ca595c0e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair325.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv index 5bdaba16..fa9621ac 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair400.10101.20105.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv index 320fdac8..bca4a648 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair400.20106.99999.csv @@ -17,15 +17,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv index 42cd5160..f15df2cf 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair450.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv index 1832f6bb..9f553fc6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Flair600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.0.10101.csv index 101bf419..27b81fd8 100644 --- a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.0.10101.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10102.10102.csv index 5a8c5fb3..548f1913 100644 --- a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10102.10102.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10103.99999.csv index a146ad23..acfa7cc4 100644 --- a/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/MultiRoomCtrlT01.10103.99999.csv @@ -17,9 +17,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv index 934e2882..6d4c8ebd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv index 934e2882..6d4c8ebd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10703.10706.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv index 2f8de2a2..0f996665 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv index 57cb826c..9491721c 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv index 8b84ac5e..52dc8800 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv index 8b84ac5e..52dc8800 100644 --- a/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Nather300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv index 09f1f6fe..8afcc457 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv index 5fea50ae..f376ef67 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv index 45d1a2e8..f53a79ea 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv index 3711037d..1dd3460a 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv index ef471ec4..a3efbb19 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv index dbf5fc1a..316ebeaa 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv index 944c8615..275d0dbd 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv index abc476fa..20e024d8 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv index 90702566..ddf3a7a3 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv index 6223335b..9bd5d787 100644 --- a/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/RenoventElan300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv index 72833579..aa6326ab 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv index 318af408..008a74f0 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10504.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv index b6a6677c..94e6a496 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv index 5a7f2bcd..2b286069 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv index 1fd9fd2a..9aa5d42a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv index 53669620..9ae2aa63 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv index a842d617..e85f6206 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv index 1549ded8..d3aa0e67 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv index 5f79a4e3..8ddb0b5b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv index ff8f779c..a00030a7 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv index 3f775ec5..bfd3fb9d 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv index d4bcffc3..08748bbe 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky150.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv index 359e371d..eb1c384e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv index 7e037962..efdd0b09 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10702.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv index 0893a355..1ee0fbd5 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv index 163034e5..f0972c40 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv index 3dbed263..4215b3c8 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv index e860d77b..8b777c25 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky200.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv index bcf40be7..0e9922ad 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv index 80db61cb..cfa409c8 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10401.10403.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv index 413bddf1..d08dcd63 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv index 7829f8f0..998b10b2 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10502.10603.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv index 430db9ba..9c286780 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv index 8e34f557..b9c50e9e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10604.10605.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv index 59bc8382..8786562f 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv index 8ef34185..7d6e1115 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10606.10607.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv index b0084a51..0266eec6 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv index 91bcadff..49639481 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10608.10706.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv index 398e9e4b..7276b743 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv index 7d12d17d..a05ce8bd 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10801.10805.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv index ba26a921..0ce43922 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv index b180535c..ecf3e6b8 100644 --- a/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Sky300.10806.99999.plus.csv @@ -17,15 +17,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/it/ValveT01.0.99999.csv index ca07b48b..dcee7929 100644 --- a/ebusd-configuration-unknown-slave-address/it/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/ValveT01.0.99999.csv @@ -17,9 +17,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv index 01b7cdd3..7842bd3a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv index 01b7cdd3..7842bd3a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10104.10104.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv index 54d478b3..4ac88d45 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv index 54d478b3..4ac88d45 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10105.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv index b3a9e6f6..25ae7b35 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv index b3a9e6f6..25ae7b35 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent200W.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv index c50d34d1..807dd941 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv index a9bea128..92412958 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv index 18e4149f..a0e71134 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv index e64e8a3f..a708362e 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300C.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv index 220a2fde..cbb73850 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv index 98c9d4b0..d8586c04 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv index 4e0aec6f..4b5e9ec3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv index 8d4941c9..1e2a7dfb 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W300.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv index f94f3a4f..19e033a3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv index 0574c2c0..4d47352b 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10101.10105.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv index c6637495..e931dc93 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv index de518771..09051019 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300W400.10106.99999.plus.csv @@ -17,15 +17,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,PosizioneVentilatore,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv index 859fb1f5..1f4520e5 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10101.10109.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv index 2a9c2ebc..d2fe90f9 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10110.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv index 85047c16..f98b10f3 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA225.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv index d4f7ebcc..56ba1785 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SA600.10101.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv index eba09488..c3359e43 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv index f5f14f6f..e425a93a 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC325.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv index b6c29f7b..134b95ab 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10101.10110.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv index 3d1da7c3..2b255d38 100644 --- a/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/it/Vitovent300WH32SC400.10111.99999.csv @@ -17,15 +17,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## COMANDI HRU COMUNI ## (WTWCommands.cs - Alcuni di essi potrebbero non essere applicabili per questo dispositivo, usare con cautela) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,ResetDiFabbrica,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResettaLeNotifiche,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,CronologiaDegliErrori,RequestErrorList,,,4090,,,,HEX:18,,, +w,,PosizioneVentilatore,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,UtilizzoDelFiltro1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,UtilizzoDelFiltroGiorni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,UtilizzoDelFiltro1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,DurataDiFunzionamento,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,FlussoTotale1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Stato corrente e sensori ## r,,VersioneDelSoftware,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv index 12f3813d..18ea4d5a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuratieparameters ## (waarden tussen haakjes naast veld zijn definities van die veldwaarden uit Brink Service Tool.) w,,LuchtdebietStand0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv index d6021084..202b75ea 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuratieparameters ## (waarden tussen haakjes naast veld zijn definities van die veldwaarden uit Brink Service Tool.) w,,LuchtdebietStand0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv index 1a030613..78851d79 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv index 4d1b88a6..38486df1 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF250.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv index 9df48da2..f8e6e789 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuratieparameters ## (waarden tussen haakjes naast veld zijn definities van die veldwaarden uit Brink Service Tool.) w,,LuchtdebietStand0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv index 762c6ca2..3a077afc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Configuratieparameters ## (waarden tussen haakjes naast veld zijn definities van die veldwaarden uit Brink Service Tool.) w,,LuchtdebietStand0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv index 10996595..ed618ecf 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv index fa32d620..26208e8b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLF350.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv index ecb3386a..0027477a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv index ecb3386a..0027477a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10603.10603.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv index d3a4b1fc..3bb88423 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv index d3a4b1fc..3bb88423 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv index a307adb0..020b82f7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv index a307adb0..020b82f7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv index c918aea3..d2debcde 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv index c918aea3..d2debcde 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv index 5c4af519..ce9d5188 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv index f8bd5aee..8b82090b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv index a57092ca..2aeacbec 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv index 1a9c303b..9025e9fd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/CWLTower300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv index d33ac13b..1d4d5ba0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv index d33ac13b..1d4d5ba0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/ConstantRPM400.10505.99999.plus.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv index 4d49fa07..25a28d8a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv index 87debe82..88772654 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10101.10700.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv index 16870dca..8bc2f6d1 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv index d41c6f3a..be825f0a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/DecentralAir70.10701.99999.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv index 1dc48dae..d0fb13d2 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv index 1dc48dae..d0fb13d2 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan10.10103.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv index 6f2bce42..667018a0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv index 4ea540ec..15f5ff40 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Elan4.10104.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,ElanStatus,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv index 7bbf5afe..133d383f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv index 13750948..888a2626 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10503.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv index e13de0c4..937b6275 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv index b8a78cb5..c04f9b7f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv index a4e20263..c15c1a69 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv index e8d573a1..b583d408 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv index 2f6eef3e..be867104 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv index 3246e1e2..d07e2bc9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv index 96d10ac6..03ebfe72 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv index a4c37b3a..45a6e251 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv index 587b3220..fb8a4a0e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv index 2839009b..8f66056b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent180.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv index 80fd209b..637f6c0b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv index 6434dc25..79859629 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv index be059948..827419a6 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv index e3445c15..a85e2d0e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv index 2f7cd92d..59121534 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv index b27e3d66..9a92dc5a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv index 83e95a59..3574974a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv index 9933823f..feb5c1dc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv index 1f13cc78..5d030cb8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv index 287b67eb..2cd19326 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv index 0dc14123..cb5260c7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv index ed3634d8..f7471a30 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv index ed3ec8d2..93c270f8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv index 27f28189..a2f702a9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv index 9b73fa52..a22b255a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv index 17376f83..8f4397f8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv index 0ab5c86f..04deda12 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv index a1af36c5..d291992c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv index 8185c0d1..0a2d984d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv index 2c78e5e8..98893250 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv index 9761c32d..8fe8474e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv index 2b1da90a..ae049c9f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv index 6066f2f4..7da0782c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv index 15676981..bdab7418 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv index 714c638c..68a15f97 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv index 0d5faaee..9c019eed 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent400.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv index 102c0832..b725ba84 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv index 9febc5e0..47fbfd68 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv index fe5ba633..c06b7926 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv index fe199ef6..2cbb0f76 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv index 2ca9080f..cd8a829f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv index 140dbcc6..16919ddb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv index 7977197e..a2d6a760 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv index b57e344b..7c8540dd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv index a45f0f18..eafb9d80 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv index 517790cc..5077c406 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Excellent450.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv index a3c3f036..ceb81292 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair200.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv index 8322142c..eddfbf19 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair225.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv index 48c35cfe..ecd61782 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair300.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv index 72e24fb8..4d31deeb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair300.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv index 248e28c1..5d97cdff 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair325.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv index 773c924c..11722562 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair325.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv index 82ec75c7..155fe922 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair400.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv index 3812d3db..6a605560 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair400.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv index efe34eeb..9d5936be 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair450.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv index 56659498..5d672c3b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Flair600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.0.10101.csv index 0e28d731..3f229773 100644 --- a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.0.10101.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10102.10102.csv index e581b4bd..07a853ff 100644 --- a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10102.10102.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10103.99999.csv index c4311c1e..cf90a4a7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/MultiRoomCtrlT01.10103.99999.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv index 03d21aa6..acf0cf32 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv index 03d21aa6..acf0cf32 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10703.10706.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv index 1227a1f3..7d9a44d7 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv index d3d2505a..07071396 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv index 59ddd0d4..102c8187 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv index 59ddd0d4..102c8187 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Nather300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv index 5a9cad10..e12a6956 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv index 11cd76ba..4d2065cd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv index e0e57709..ddf03805 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv index dda21ca4..27e91c9b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv index dfe49d58..817b0fc8 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv index 14158a6a..e7dc94e9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv index d66bf39b..90a8e201 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv index abc225cb..7449ae3b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv index 1ad93401..d139faa6 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv index 4475004a..6555ebfd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/RenoventElan300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv index b2796d7a..9dc78094 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv index f225f7eb..afb94686 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10504.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv index 11272354..fcd7139d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv index 672736c2..8a9a0238 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv index d4b24a7c..7ebf4fbd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv index 77093408..2b023022 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv index f01dcc53..a50ffc4f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv index bc4f8cd6..e9f602fc 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv index e7c5969b..62eee558 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv index 7070e360..08bec71a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv index 4b22fc25..77fec973 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv index a0417a81..f7899055 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky150.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv index e18b9e23..7d787901 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv index cba55166..170773e0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10702.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv index 796344ac..1992b2dd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv index 0b7daf69..210012da 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv index dc34bf40..5584babf 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv index 16c62ec6..f482814e 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky200.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv index 9a10358c..f3b1c092 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv index 87855426..91e41c49 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv index 7272bee8..b768c9b0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv index c4bcea43..cd393708 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv index e0a441ca..010748b3 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv index b84dd5e1..5a8c6f4d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv index 98a83d1e..4c9a879d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv index c26d67e7..c5eb1455 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv index ccbe05e4..3924712f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv index a637e2ee..5f7cad84 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv index 39501bfe..763ba99a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv index e92fbe56..8b61997b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv index 0d8212fb..b12eb4ea 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv index 4a78b887..bf59704c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Sky300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/nl/ValveT01.0.99999.csv index d2227694..b5df4e73 100644 --- a/ebusd-configuration-unknown-slave-address/nl/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/ValveT01.0.99999.csv @@ -19,9 +19,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv index 471e211a..317f22f0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv index 471e211a..317f22f0 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10104.10104.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv index c34b5b63..cd5fbaa4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv index c34b5b63..cd5fbaa4 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10105.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv index 753d943a..469ffd59 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv index 753d943a..469ffd59 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent200W.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv index aa6c4dfa..fae579fd 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv index e2bb2ab0..178c0c16 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv index a9b05d0a..c0766bb9 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv index 0676d639..85e10c5d 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300C.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv index 0ab96993..22db7f15 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv index 7e36a557..a4a5792a 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv index c22c3ec7..53f4d6ce 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv index 3db8cb89..06886e73 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W300.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv index 1bc53f1a..36264d24 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv index d5d99562..e29e4312 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv index 84086291..4e5eecbb 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv index a40569a6..5af9f98f 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300W400.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,VentilatorMode,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv index 662ef0a3..9255eaed 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10101.10109.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv index b721ec1a..eb60871b 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10110.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv index 818c6786..e5853365 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA225.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv index 910931a4..30d02f93 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SA600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv index 8959574c..e33a3c01 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv index b9ff5adf..8abbca84 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC325.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv index 1399a645..03e0b51c 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv index dddcdb4c..b5356838 100644 --- a/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/nl/Vitovent300WH32SC400.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## GEMEENSCHAPPELIJKE HRU COMMANDO'S ## (WTWCommands.cs - Sommige zijn mogelijk niet van toepassing op dit apparaat, gebruik met voorzichtigheid) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,FabrieksinstellingenInstellen,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetMeldingen,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,FoutHistorie,RequestErrorList,,,4090,,,,HEX:18,,, +w,,VentilatorMode,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,Filtergebruik1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,FiltergebruikDagen,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,Filtergebruik1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,Bedieningstijd,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,TotaalDebiet1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Huidige staat en sensoren ## r,,SoftwareVersie,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv index 27d46f3a..98d3ddb4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametry konfiguracyjne ## (wartości w nawiasach obok pola to definicje tych wartości pól z Narzędzia serwisowego Brink.) w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv index 8d9332f1..75513fc2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametry konfiguracyjne ## (wartości w nawiasach obok pola to definicje tych wartości pól z Narzędzia serwisowego Brink.) w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv index 3207c408..89ceb3b1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv index c411261b..b602e35c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF250.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF250,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv index 0c5c5161..350eaae9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametry konfiguracyjne ## (wartości w nawiasach obok pola to definicje tych wartości pól z Narzędzia serwisowego Brink.) w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv index 6e9ba7a0..e614e8f1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10806.10808.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Parametry konfiguracyjne ## (wartości w nawiasach obok pola to definicje tych wartości pól z Narzędzia serwisowego Brink.) w,,PrzepływPowietrzaTryb0,FlowMode0,,,4080,21,,,SIR,,m³/h,[min:0;max:50;step:50;default:50] diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv index 50ef476e..5207dfa1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv index 94e84cfd..5b4bcf8c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLF350.10809.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLF350,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv index 4c931e06..1097abf5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv index 4c931e06..1097abf5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10603.10603.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv index e6a645e3..03c19dbd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv index e6a645e3..03c19dbd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv index 30afc4c1..6ee4ff03 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv index 30afc4c1..6ee4ff03 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv index 574e231a..12de3b7e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv index 574e231a..12de3b7e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv index 07c0a1a6..8c3b346d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv index f474d8f8..3c9e5e31 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv index 8a859532..25b012f7 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv index 79b00dd3..a97e68d1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/CWLTower300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,CWLTower300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv index 7bce151a..ba3ca3d2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv index 7bce151a..ba3ca3d2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/ConstantRPM400.10505.99999.plus.csv @@ -19,15 +19,15 @@ *w,ConstantRPM400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv index cbc36b54..d6e4ce0e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv index 243468bc..5f17e18f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10101.10700.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv index e96c9c4e..2b84ed8b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv index 8400912e..cdc4fbbe 100644 --- a/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/DecentralAir70.10701.99999.plus.csv @@ -19,14 +19,14 @@ *w,DecentralAir70,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv index 865e97a6..a35974df 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv index 865e97a6..a35974df 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan10.10103.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan10,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv index a41a0046..f981cf12 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv index 72da3886..1db94288 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Elan4.10104.99999.plus.csv @@ -19,15 +19,15 @@ *w,Elan4,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,StatusElan,ElanStatus,,,4022,01,,,UCH,0=NotInitialized;1=UnknownError;2=PowerUp;3=ModeLow;4=ModeHigh;5=ModeNormal;6=ModeOffNormal;7=ModeCooling;8=ModeOutSideHigh;9=ErrorMinFlow;10=ErrorNoFlow,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv index 84569cad..46fc908e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv index 90a222ba..9d89b10e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10503.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv index 41cd61c1..eff443d5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv index f2f220c0..b08843df 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv index 1f12154d..a6523c36 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv index 9d647e7d..1db0a998 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv index b6683cc9..086d4fa6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv index 5f709c5d..eab19165 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv index 67e6da36..33fc6d77 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv index b21b2d3d..27e58de5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv index d6dff1f5..12e2af7f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv index 37282326..c34b5d40 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent180.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent180,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv index 3a84f9d5..ba6cd66d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv index 21ea05ec..16967b7f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv index d3a3af19..e5fbd288 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv index 56f5ddd0..540c76f6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv index 40191ea8..b05d77a2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv index b4a87ca3..c320ecdc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv index faeef7e6..262fbcb3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv index 5855fb61..9a99f051 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv index e6cfb101..834c8b27 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv index 037bf4dc..b9fca104 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv index c0173ab0..0d39fb5f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv index 96051171..25d09e68 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv index 0f765b1f..7213509c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv index 11a2025b..213829f0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv index 1906c588..52d6a584 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv index 09a41fba..f915264d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv index edb21ffc..cf7e99ad 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv index 7f09dd49..84440e97 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv index 31700727..c6316433 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv index d5750371..7556c770 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv index 1c8cf6f7..1eb5f188 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv index a72a4324..616d2639 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv index 3cb29614..978670e3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv index 10662e69..e3064d25 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv index 29f17c68..3eeded3f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv index 28aa44b2..5bfe6200 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent400.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv index d1fd7aba..30054ca8 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv index 78e0b0ca..bf1a483b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv index 2f707f77..7718fada 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv index 46d3fd77..c569f506 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv index f9cb424c..678577ab 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv index baa24afe..b3676c84 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv index 34fd6822..4d18f9a6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv index f4f4ae2d..9debc1a9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv index 8f09e132..cbcd8a79 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv index 6cf499e8..0131422c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Excellent450.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Excellent450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv index e90148a6..c5268a30 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair200.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv index f87ee3e6..47765ebd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair225.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair225,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv index 5f81af5f..24192abd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair300.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv index 3860adac..1ca6b388 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair300.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv index d270586a..1342c3fb 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair325.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv index a16b4509..9cd5d0e9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair325.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair325,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv b/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv index 9fcb0078..ea5d5cb9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair400.10101.20105.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv index a4d4b3dd..db61ebc9 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair400.20106.99999.csv @@ -19,15 +19,15 @@ *w,Flair400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv index 98b399a4..aeadb4e5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair450.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair450,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv index 93800429..cc4a60dd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Flair600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Flair600,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.0.10101.csv b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.0.10101.csv index a191d75b..afae48de 100644 --- a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.0.10101.csv +++ b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.0.10101.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10102.10102.csv b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10102.10102.csv index 6767e068..d0f6cf8f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10102.10102.csv +++ b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10102.10102.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10103.99999.csv b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10103.99999.csv index f0f2948b..7563f6e7 100644 --- a/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10103.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/MultiRoomCtrlT01.10103.99999.csv @@ -19,9 +19,9 @@ *w,MultiRoomCtrlT01,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv index 28381953..46248318 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv index 28381953..46248318 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10703.10706.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv index 964bae40..e5c180bc 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv index 2b4a4289..3b500203 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv index 2c38b78d..9290a53f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv index 2c38b78d..9290a53f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Nather300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Nather300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv index b98ae12a..682bb70b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv index dfc67059..b288f12a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv index 76b29a86..88cd5a7e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv index c637381a..7852d17d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv index b0cf0f63..707ce790 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv index 7abc0957..8a1be71a 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv index 00c488de..26a05ff3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv index d4d08030..bf61084b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv index edd4d6b5..db3d9184 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv index 35e99293..6ddf7b32 100644 --- a/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/RenoventElan300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,RenoventElan300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv index f1a9a27c..828e4868 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv index 4bc3bae8..2cffd444 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10504.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv index 2365eed3..f95c2d30 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv index 2cadd05d..f9a25586 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv index ea28abcf..22e6b6f3 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv index 79d170af..5af5eed2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv index 5f1f9df2..ce770952 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv index 859b8679..38aa55dd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv index 736eaf52..7b333879 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv index fe968747..6e8b535c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv index aedfcf46..ba53196e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv index 4c6d6410..67b37fa4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky150.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky150,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv index 614ae9b0..4e884de2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv index 0ceb8094..42c8d68e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10702.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv index 23fa8558..3867063e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv index 4ece2ba0..5b823ef6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv index ac27493c..63c89eae 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv index 55781533..35a19d1c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky200.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky200,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv index d7ba5d02..380d598b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv index 6c83c817..70c7eccd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10401.10403.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv index 3b7d512f..86a3dd30 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv index 38194836..d24d8141 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10502.10603.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv index dfb8c21b..79cc4be0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv index 2f95978d..eac242f6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10604.10605.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv index 70c97e8a..245956e4 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv index 3b2e99ab..ccc45f0f 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10606.10607.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv index 1683cfd5..a525a5e1 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv index 2ad617e5..0d3e22f0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10608.10706.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv index 8485b19f..ddff3159 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv index 8b0c7001..eeb27521 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10801.10805.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv index 55fc792a..9985ae9d 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv index 52cf16ad..de90d7b5 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Sky300.10806.99999.plus.csv @@ -19,15 +19,15 @@ *w,Sky300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/ValveT01.0.99999.csv b/ebusd-configuration-unknown-slave-address/pl/ValveT01.0.99999.csv index a7216932..013713fb 100644 --- a/ebusd-configuration-unknown-slave-address/pl/ValveT01.0.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/ValveT01.0.99999.csv @@ -19,9 +19,9 @@ *w,ValveT01,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv index 3e5e0900..57c14f40 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv index 3e5e0900..57c14f40 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10104.10104.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv index a68353d6..1eb98399 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv index a68353d6..1eb98399 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10105.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv index a2636cf0..de8f8d00 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv index a2636cf0..de8f8d00 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent200W.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent200W,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv index 6e84be2f..19a8f6f2 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv index 9bff1e37..8ebf5eaf 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv index 9d8c002c..10229af6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv index 33ed5c59..4bd148d0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300C.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300C,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv index 60f0acb6..d2f188b8 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv index eaa8bf81..ee8e7504 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv index 0d8b620d..89d56e3e 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv index 6e07f667..74fa6804 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W300.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W300,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv index 79d7c967..d877d89c 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv index 16ecc308..a543190b 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10101.10105.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv index 4a20b29a..c69645fd 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv index f9c526aa..09ae04c7 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300W400.10106.99999.plus.csv @@ -19,15 +19,15 @@ *w,Vitovent300W400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,TrybWentylatora,FanMode,,,4022,01,,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv index 801aa11e..e8499053 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10101.10109.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv index 9a21f838..e4404224 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10110.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv index 7909e848..23c1becb 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA225.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA225,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv index d2e94ab3..9f46bbe6 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SA600.10101.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SA600,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv index c844f01f..04686247 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv index 2ed635ae..10a63ecf 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC325.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC325,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv index 92f0a6ac..f25a22d7 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10101.10110.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv index 1ca946aa..52034ab0 100644 --- a/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv +++ b/ebusd-configuration-unknown-slave-address/pl/Vitovent300WH32SC400.10111.99999.csv @@ -19,15 +19,15 @@ *w,Vitovent300WH32SC400,,,,[fill_your_slave_address_here], ## WSPÓLNE KOMENDY HRU ## (WTWCommands.cs - Niektóre z nich mogą nie być odpowiednie dla tego urządzenia, używaj z ostrożnością) -w,,FactoryReset,,,,40ff,466163746f72795265736574 -w,,ResetNotifications,,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. -r,,RequestErrorList,,,,4090,,,,HEX:18,,, -w,,FanMode,,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, -r,,FilterNotificationFlow,,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalFilterDays,,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, -r,,TotalFilterFlow,,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, -r,,TotalOperatingHours,,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, -r,,TotalFlow,,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +w,,PrzywracanieUstawieńFabrycznych,FactoryReset,,,40ff,466163746f72795265736574 +w,,ResetujPowiadomienia,ResetNotifications,,,4091,,,,UIR,0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. +r,,HistoriaBłędów,RequestErrorList,,,4090,,,,HEX:18,,, +w,,TrybWentylatora,FanMode,,,40a1,,,,ULR,0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High,, +r,,ZużycieFiltra1000m3,FilterNotificationFlow,,,4050,1c,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,ZużycieFiltraDni,TotalFilterDays,,,4050,22,,,UIR,,Days,,Min,,UIR,,Days,,Max,,UIR,,Days,,Step,,UIR,,Days,,Default,,UIR,,Days, +r,,ZużycieFiltra1000m3,TotalFilterFlow,,,4050,23,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, +r,,CzasPracy,TotalOperatingHours,,,4050,24,,,UIR,-5,Hours,,Min,,UIR,-5,Hours,,Max,,UIR,-5,Hours,,Step,,UIR,-5,Hours,,Default,,UIR,-5,Hours, +r,,PrzepływCałkowity1000m3,TotalFlow,,,4050,25,,,UIR,-1000,m³,,Min,,UIR,-1000,m³,,Max,,UIR,-1000,m³,,Step,,UIR,-1000,m³,,Default,,UIR,-1000,m³, ## Aktualny stan i czujniki ## r,,WersjaOprogramowania,SoftwareVersion,,,4022,00,,,STR:13,,, diff --git a/src/ebus_message.py b/src/ebus_message.py index a0c252d7..7c56b4d4 100644 --- a/src/ebus_message.py +++ b/src/ebus_message.py @@ -1,3 +1,5 @@ +from parse_xaml import get_name + MSG_TYPE_WRITE = 'w' MSG_TYPE_READ = 'r' @@ -35,14 +37,16 @@ def __hash__(self): def __repr__(self): return str(self) +# TODO translate the fields names +# TODO translate the values in enums class EbusMessage: - def __init__(self, name: str, pbsb: int, id: int|None, type: str, fields: list[Field], comment: str = ''): + def __init__(self, name: str, parameter_name: str, pbsb: int, id: int|None, type: str, fields: list[Field]): self.name: str = name self.pbsb: int = pbsb self.id: int|None = id self.type: str = type self.fields: list[Field] = fields - self.comment: str = comment + self.parameter_name = parameter_name # This one is necessary for correct translation def __str__(self): return str([vars(self)[key] for key in sorted(vars(self).keys())]) @@ -59,10 +63,10 @@ def __hash__(self): def __repr__(self): return str(self) - def dump(self, circuit: str = '', slave_address: str = '') -> str: + def dump(self, language: str, circuit: str = '', slave_address: str = '') -> str: # type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment id_str = f'{self.id:02x}' if self.id else '' - result = f'{self.type},{circuit},{self.name},{self.comment},,{slave_address},{self.pbsb:04x},{id_str}' + result = f'{self.type},{circuit},{get_name(self.parameter_name, language)},{self.name},,{slave_address},{self.pbsb:04x},{id_str}' for field in self.fields: values_str = multiplier_to_divider(field.multiplier) if field.values == '' else field.values result += f',{field.name},,{field.datatype},{values_str},{field.unit},{field.comment}' @@ -70,12 +74,12 @@ def dump(self, circuit: str = '', slave_address: str = '') -> str: class BrinkConfigEbusMessage(EbusMessage): - def __init__(self, name: str, id: int, type: str, is_signed: bool, multiplier: float, values: str, unit: str, comment: str = ''): + def __init__(self, name: str, parameter_name: str, id: int, type: str, is_signed: bool, multiplier: float, values: str, unit: str): field_names = ['', 'Min', 'Max', 'Step', 'Default'] self.name = name self.id = id self.type = type - self.comment = comment + self.parameter_name = parameter_name # This one is necessary for correct translation if is_signed: datatype = 'SIR' @@ -104,17 +108,17 @@ def __init__(self, name: str, id: int, type: str, is_signed: bool, multiplier: f # Factory reset is a write to address 40FF with no ID and a string "FactoryReset" in ascii -> "40FF0C466163746F72795265736574" # EbusMessage('FactoryReset', 0x40ff, None, 'w', [Field('', 'STR:12', 12, 1.0, '0x466163746F72795265736574=FactoryReset', '')]), - EbusMessage('FactoryReset', 0x40ff, 0x466163746F72795265736574, 'w', []), + EbusMessage('FactoryReset', 'diagnosticsViewbtnFactoryReset', 0x40ff, 0x466163746F72795265736574, 'w', []), # Filter and error reset is split to two messages - one for writing and one for reading. I am unaware how to otherwise specify this so that MQTT would understand this Command-Response type of message ## # ru,,ResetErrors,409103FFFFFF,,,4091,3c0001,,,UIR,0=ResetNotRequested;1=ResetSuccessful;2=ResetRelayed;3=NoErrorsFound;4=ResetFailed;5=BlockingErrors,,,,,IGN:2,,, # ru,,ResetFilter,409103FFFFFF,,,4091,3c0100,,,IGN:1,,,,,,UIR,0=ResetNotRequested;1=ResetSuccessful;2=ResetRelayed;3=FilterWarningWasNotSet;4=ResetFailed,,,,,IGN:1,,, # Reset notification logic and response codes is based on HandleResetNotificationsResponse function from BCSServiceTool - EbusMessage('ResetNotifications', 0x4091, 0x00, 'w', [Field('', 'UIR', 2, 1.0, '0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested', '', 'NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation.')]), + EbusMessage('ResetNotifications', 'ResetNotificationDialogTitle', 0x4091, 0x00, 'w', [Field('', 'UIR', 2, 1.0, '0x0001=Errors;0x0100=Filter;0x0101=ErrorsAndFilter;0x0000=NoResetRequested', '', 'NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation.')]), - EbusMessage('RequestErrorList', 0x4090, 0x00, 'r', [Field('', 'HEX:18', 18, 1.0, '', '')]), - EbusMessage('FanMode', 0x40a1, None, 'w', [Field('', 'ULR', 4, 1.0, '0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High', '')]), + EbusMessage('RequestErrorList', 'errorHistoryViewTableTitle', 0x4090, 0x00, 'r', [Field('', 'HEX:18', 18, 1.0, '', '')]), + EbusMessage('FanMode', 'parameterDescriptionFanMode', 0x40a1, None, 'w', [Field('', 'ULR', 4, 1.0, '0x0=Holiday;0x00010001=Reduced;0x00020002=Normal;0x00030003=High', '')]), # The following message simply does not work. The last IGN bytes clearly can be zeroes only sometimes, in general they need to be filed with some value that I was nto able to decode the meaning. # EbusMessage('FanMode', 0x40a3, 0x01, 'w', [Field('', 'UCH', 1, 1.0, '0=Min;1=Low;2=Medium;3=High', ''), Field('', 'IGN:2', 2, 1.0, '', '')]), @@ -130,13 +134,13 @@ def __init__(self, name: str, id: int, type: str, is_signed: bool, multiplier: f # w,,WTWControlMode,WTWControlMode,,,40A2,,,,UCH,,, # w,,WTWControlDemandStatus,WTWControlDemandStatus,,,40A3,,,,HEX:4,,, - BrinkConfigEbusMessage('FilterNotificationFlow', 0x1c, 'r', False, 1000, '', 'm³'), - BrinkConfigEbusMessage('TotalFilterDays', 0x22, 'r', False, 1.0, '', 'Days'), - BrinkConfigEbusMessage('TotalFilterFlow', 0x23, 'r', False, 1000,'', 'm³'), + BrinkConfigEbusMessage('FilterNotificationFlow', 'parameterDescriptionFiltersUsedIn1000M3',0x1c, 'r', False, 1000, '', 'm³'), + BrinkConfigEbusMessage('TotalFilterDays', 'parameterDescriptionFiltersUsedInDays', 0x22, 'r', False, 1.0, '', 'Days'), + BrinkConfigEbusMessage('TotalFilterFlow', 'parameterDescriptionFiltersUsedIn1000M3', 0x23, 'r', False, 1000,'', 'm³'), # Based on https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 and my obervation, the multiplier mathches; Contrary to what WTWCommands.cs says, the ID is mixed up between OperatingHours and TotalFlow - BrinkConfigEbusMessage('TotalOperatingHours', 0x24, 'r', False, 5,'', 'Hours'), + BrinkConfigEbusMessage('TotalOperatingHours', 'parameterDescriptionOperatingTime', 0x24, 'r', False, 5,'', 'Hours'), # Based on https://github.com/dstrigl/ebusd-config-brink-renovent-excellent-300 and my obervation, the multiplier mathches; Contrary to what WTWCommands.cs says, the ID is mixed up between OperatingHours and TotalFlow - BrinkConfigEbusMessage('TotalFlow', 0x25, 'r', False, 1000, '', 'm³'), + BrinkConfigEbusMessage('TotalFlow', 'parameterDescriptionTotalFlowIn1000M3', 0x25, 'r', False, 1000, '', 'm³'), ] \ No newline at end of file diff --git a/src/out.py b/src/out.py index dc4c8868..64461265 100644 --- a/src/out.py +++ b/src/out.py @@ -163,7 +163,7 @@ def csv_known_device(sensors: list[Sensor], parameters: list[Parameter], device_ file_str = translations[language]['COMMENT_HEADER'] + '\n'+ str_slave_and_circuit_mask('r', device_name, slave_address) + str_slave_and_circuit_mask('w', device_name, slave_address) file_str += translations[language]['COMMENT_COMMON_COMMANDS'] for msg in brink_wtw_commands_list: - file_str += msg.dump() + file_str += msg.dump(language) file_str += translations[language]['COMMENT_CURRENT_STATE'] file_str += csv_from_sensors(sensors, language) file_str += translations[language]['COMMENT_PARAMETERS'] @@ -209,7 +209,7 @@ def write_unknown_address_devices(device_models: dict[str, DeviceModel], languag elif device_name in ['ValveT01', 'MultiRoomCtrlT01'] and msg.name not in ['FactoryReset', 'ResetNotifications', 'RequestErrorList']: # Other than these messages are not meaningful for a valve continue - file_str += msg.dump() + file_str += msg.dump(language) for version_range, sensors in device_model.sensors.items(): if version_range.contains(subversion): file_str += translations[language]['COMMENT_CURRENT_STATE']