Notifications
You must be signed in to change notification settings - Fork 147
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Merge branch 'master' of https://github.com/Louisvdw/dbus-serialbattery
- Loading branch information
Showing
5 changed files
with
173 additions
and
4 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -1,3 +1,3 @@ | ||
#!/bin/sh | ||
dos2unix rc.local conf/serial-starter.d etc/dbus-serialbattery/service/run etc/dbus-serialbattery/service/log/run etc/dbus-serialbattery/LICENSE etc/dbus-serialbattery/README.md etc/dbus-serialbattery/start-serialbattery.sh etc/dbus-serialbattery/disabledriver.sh etc/dbus-serialbattery/installlocal.sh etc/dbus-serialbattery/installrelease.sh etc/dbus-serialbattery/dbus-serialbattery.py etc/dbus-serialbattery/dbushelper.py etc/dbus-serialbattery/battery.py etc/dbus-serialbattery/utils.py etc/dbus-serialbattery/lltjbd.py etc/dbus-serialbattery/daly.py etc/dbus-serialbattery/ant.py etc/dbus-serialbattery/util_max17853.py etc/dbus-serialbattery/mnb.py etc/dbus-serialbattery/jkbms.py etc/dbus-serialbattery/sinowealth.py | ||
tar -czvf venus-data.tar.gz --mode='a+rwX' rc.local conf/serial-starter.d etc/dbus-serialbattery/service/run etc/dbus-serialbattery/service/log/run etc/dbus-serialbattery/LICENSE etc/dbus-serialbattery/README.md etc/dbus-serialbattery/start-serialbattery.sh etc/dbus-serialbattery/disabledriver.sh etc/dbus-serialbattery/installlocal.sh etc/dbus-serialbattery/installrelease.sh etc/dbus-serialbattery/dbus-serialbattery.py etc/dbus-serialbattery/dbushelper.py etc/dbus-serialbattery/battery.py etc/dbus-serialbattery/utils.py etc/dbus-serialbattery/lltjbd.py etc/dbus-serialbattery/daly.py etc/dbus-serialbattery/ant.py etc/dbus-serialbattery/util_max17853.py etc/dbus-serialbattery/mnb.py etc/dbus-serialbattery/jkbms.py etc/dbus-serialbattery/sinowealth.py | ||
dos2unix rc.local conf/serial-starter.d etc/dbus-serialbattery/service/run etc/dbus-serialbattery/service/log/run etc/dbus-serialbattery/LICENSE etc/dbus-serialbattery/README.md etc/dbus-serialbattery/start-serialbattery.sh etc/dbus-serialbattery/disabledriver.sh etc/dbus-serialbattery/installlocal.sh etc/dbus-serialbattery/installrelease.sh etc/dbus-serialbattery/dbus-serialbattery.py etc/dbus-serialbattery/dbushelper.py etc/dbus-serialbattery/battery.py etc/dbus-serialbattery/utils.py etc/dbus-serialbattery/lltjbd.py etc/dbus-serialbattery/daly.py etc/dbus-serialbattery/ant.py etc/dbus-serialbattery/util_max17853.py etc/dbus-serialbattery/mnb.py etc/dbus-serialbattery/jkbms.py etc/dbus-serialbattery/sinowealth.py etc/dbus-serialbattery/renogy.py | ||
tar -czvf venus-data.tar.gz --mode='a+rwX' rc.local conf/serial-starter.d etc/dbus-serialbattery/service/run etc/dbus-serialbattery/service/log/run etc/dbus-serialbattery/LICENSE etc/dbus-serialbattery/README.md etc/dbus-serialbattery/start-serialbattery.sh etc/dbus-serialbattery/disabledriver.sh etc/dbus-serialbattery/installlocal.sh etc/dbus-serialbattery/installrelease.sh etc/dbus-serialbattery/dbus-serialbattery.py etc/dbus-serialbattery/dbushelper.py etc/dbus-serialbattery/battery.py etc/dbus-serialbattery/utils.py etc/dbus-serialbattery/lltjbd.py etc/dbus-serialbattery/daly.py etc/dbus-serialbattery/ant.py etc/dbus-serialbattery/util_max17853.py etc/dbus-serialbattery/mnb.py etc/dbus-serialbattery/jkbms.py etc/dbus-serialbattery/sinowealth.py etc/dbus-serialbattery/renogy.py |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,166 @@ | ||
# -*- coding: utf-8 -*- | ||
from __future__ import absolute_import, division, print_function, unicode_literals | ||
from battery import Protection, Battery, Cell | ||
from utils import * | ||
from struct import * | ||
import struct | ||
|
||
class RenogyCell(Cell): | ||
temp = None | ||
|
||
class Renogy(Battery): | ||
|
||
def __init__(self, port,baud): | ||
super(Renogy, self).__init__(port,baud) | ||
self.type = self.BATTERYTYPE | ||
|
||
BATTERYTYPE = "Renogy" | ||
LENGTH_CHECK = 4 | ||
LENGTH_POS = 2 | ||
|
||
# command bytes [Address field][Function code (03 = Read register)][Register Address (2 bytes)][Data Length (2 bytes)][CRC (2 bytes little endian)] | ||
# Battery addresses start at 0 ascii, 30 hex | ||
command_address = b"0" | ||
command_read = b"\x03" | ||
# Core data = voltage, temp, current, soc | ||
command_cell_count = b"\x13\x88\x00\x01" #Register 5000 | ||
command_cell_voltages = b"\x13\x89\x00\x04" #Registers 5001-5004 | ||
command_cell_temps = b"\x13\x9A\x00\x04" #Registers 5018-5021 | ||
command_total_voltage = b"\x13\xB3\x00\x01" #Register 5043 | ||
command_bms_temp1 = b"\x13\xAD\x00\x01" #Register 5037 | ||
command_bms_temp2 = b"\x13\xB0\x00\x01" #Register 5040 | ||
command_current = b"\x13\xB2\x00\x01" #Register 5042 (signed int) | ||
command_capacity = b"\x13\xB6\x00\x02" #Registers 5046-5047 (long) | ||
command_soc = b"\x13\xB2\x00\x04" #Registers 5042-5045 (amps, volts, soc as long) | ||
# Battery info | ||
command_manufacturer = b"\x14\x0C\x00\x08" #Registers 5132-5139 (8 byte string) | ||
command_model = b"\x14\x02\x00\x08" #Registers 5122-5129 (8 byte string) | ||
command_serial_number = b"\x13\xF6\x00\x08" #Registers 5110-5117 (8 byte string) | ||
command_firmware_version = b"\x14\x0A\x00\x02" #Registers 5130-5131 (2 byte string) | ||
# BMS warning and protection config | ||
|
||
def test_connection(self): | ||
# call a function that will connect to the battery, send a command and retrieve the result. | ||
# The result or call should be unique to this BMS. Battery name or version, etc. | ||
# Return True if success, False for failure | ||
return self.read_gen_data() | ||
|
||
def get_settings(self): | ||
# After successful connection get_settings will be call to set up the battery. | ||
# Set the current limits, populate cell count, etc | ||
# Return True if success, False for failure | ||
self.max_battery_current = MAX_BATTERY_CURRENT | ||
self.max_battery_discharge_current = MAX_BATTERY_DISCHARGE_CURRENT | ||
|
||
self.max_battery_voltage = MAX_CELL_VOLTAGE * self.cell_count | ||
self.min_battery_voltage = MIN_CELL_VOLTAGE * self.cell_count | ||
return True | ||
|
||
def refresh_data(self): | ||
# call all functions that will refresh the battery data. | ||
# This will be called for every iteration (1 second) | ||
# Return True if success, False for failure | ||
result = self.read_soc_data() | ||
result = result and self.read_cell_data() | ||
result = result and self.read_temp_data() | ||
|
||
return result | ||
|
||
def read_gen_data(self): | ||
model = self.read_serial_data_renogy(self.command_model) | ||
# check if connection success | ||
if model is False: | ||
return False | ||
model_num = unpack('16s',model)[0] | ||
self.hardware_version = "Renogy " + str(model_num) | ||
logger.info(self.hardware_version) | ||
|
||
self.temp_sensors = 2 | ||
|
||
if self.cell_count is None: | ||
cc = self.read_serial_data_renogy(self.command_cell_count) | ||
self.cell_count = struct.unpack('>H',cc)[0] | ||
|
||
for c in range(self.cell_count): | ||
self.cells.append(RenogyCell(False)) | ||
|
||
firmware = self.read_serial_data_renogy(self.command_firmware_version) | ||
firmware_major, firmware_minor = unpack_from('2s2s', firmware) | ||
self.version = float(str(firmware_major) + "." + str(firmware_minor)) | ||
capacity = self.read_serial_data_renogy(self.command_capacity) | ||
self.capacity = unpack('>L',capacity)[0] | ||
return True | ||
|
||
def read_soc_data(self): | ||
soc_data = self.read_serial_data_renogy(self.command_soc) | ||
# check if connection success | ||
if soc_data is False: | ||
return False | ||
|
||
current, voltage, self.capacity_remain = unpack_from('>hhL', soc_data) | ||
self.current = current / 100 | ||
self.voltage = voltage / 10 | ||
self.soc = self.capacity_remain / self.capacity * 100 | ||
return True | ||
|
||
def read_cell_data(self): | ||
cell_volt_data = self.read_serial_data_renogy(self.command_cell_voltages) | ||
cell_temp_data = self.read_serial_data_renogy(self.command_cell_temps) | ||
for c in range(self.cell_count): | ||
try: | ||
cell_volts = unpack_from('>H', cell_volt_data, c*2) | ||
cell_temp = unpack_from('>H', cell_temp_data, c*2) | ||
if len(cell_volts) != 0: | ||
self.cells[c].voltage = cell_volts[0] / 10 | ||
self.cells[c].temp = cell_temp[0] / 10 | ||
except struct.error: | ||
self.cells[c].voltage = 0 | ||
return True | ||
|
||
def read_temp_data(self): | ||
temp1 = self.read_serial_data_renogy(self.command_bms_temp1) | ||
temp2 = self.read_serial_data_renogy(self.command_bms_temp2) | ||
if temp1 is False: | ||
return False | ||
self.temp1 = unpack('>H',temp1)[0] / 10 | ||
self.temp2 = unpack('>H',temp2)[0] / 10 | ||
|
||
return True | ||
|
||
def read_bms_config(self): | ||
return True | ||
|
||
def calc_crc(self, data): | ||
crc = 0xFFFF | ||
for pos in data: | ||
crc ^= pos | ||
for i in range(8): | ||
if ((crc & 1) != 0): | ||
crc >>= 1 | ||
crc ^= 0xA001 | ||
else: | ||
crc >>= 1 | ||
return struct.pack('<H',crc) | ||
|
||
def generate_command(self, command): | ||
buffer = bytearray(self.command_address) | ||
buffer += self.command_read | ||
buffer += command | ||
buffer += self.calc_crc(buffer) | ||
|
||
return buffer | ||
|
||
def read_serial_data_renogy(self, command): | ||
# use the read_serial_data() function to read the data and then do BMS spesific checks (crc, start bytes, etc) | ||
data = read_serial_data(self.generate_command(command), self.port, self.baud_rate, self.LENGTH_POS, self.LENGTH_CHECK) | ||
if data is False: | ||
return False | ||
|
||
start, flag, length = unpack_from('BBB', data) | ||
checksum = unpack_from('>H', data, length + 3) | ||
|
||
if flag == 3: | ||
return data[3:length+3] | ||
else: | ||
logger.error(">>> ERROR: Incorrect Reply") | ||
return False |