Notifications
You must be signed in to change notification settings - Fork 178
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
test(analyses): add 8.2 features to analyses battery #17134
Open
y3rsh
wants to merge
2
commits into
edge
Choose a base branch
from
eight-two-ab
base: edge
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
File renamed without changes.
99 changes: 99 additions & 0 deletions
99
analyses-snapshot-testing/files/protocols/Flex_S_v2_21_tc_lids_happy_path.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,99 @@ | ||
from typing import List, Dict, Any, Optional | ||
from opentrons.protocol_api import ProtocolContext, Labware | ||
|
||
metadata = {"protocolName": "Opentrons Flex Deck Riser with TC Lids Test"} | ||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
|
||
|
||
""" | ||
Setup: | ||
- 1-5x lids are stacked in deck D2 | ||
- Thermocycler installed | ||
|
||
Run: | ||
- For each lid in the stack (1-5x) | ||
- Move lid in D2 to Thermocycler | ||
- Remove top-most lid | ||
- PAUSE, wait for tester to press continue | ||
- Move lid from Thermocycler to new slot C2 | ||
- Stacked onto any previously placed lids | ||
""" | ||
|
||
LID_STARTING_SLOT = "B2" | ||
LID_ENDING_SLOT = "C2" | ||
LID_COUNT = 3 | ||
LID_DEFINITION = "opentrons_tough_pcr_auto_sealing_lid" | ||
LID_BOTTOM_DEFINITION = "opentrons_tough_pcr_auto_sealing_lid" | ||
DECK_RISER_NAME = "opentrons_flex_deck_riser" | ||
USING_THERMOCYCLER = True | ||
|
||
OFFSET_DECK = { | ||
"pick-up": {"x": 0, "y": 0, "z": 0}, | ||
"drop": {"x": 0, "y": 0, "z": 0}, | ||
} | ||
OFFSET_THERMOCYCLER = { | ||
"pick-up": {"x": 0, "y": 0, "z": 0}, | ||
"drop": {"x": 0, "y": 0, "z": 0}, | ||
} | ||
|
||
|
||
def _move_labware_with_offset_and_pause( | ||
protocol: ProtocolContext, | ||
labware: Labware, | ||
destination: Any, | ||
pick_up_offset: Optional[Dict[str, float]] = None, | ||
drop_offset: Optional[Dict[str, float]] = None, | ||
) -> None: | ||
protocol.move_labware( | ||
labware, | ||
destination, | ||
use_gripper=True, | ||
pick_up_offset=pick_up_offset, | ||
drop_offset=drop_offset, | ||
) | ||
|
||
|
||
def run(protocol: ProtocolContext): | ||
# SETUP | ||
deck_riser_adapter = protocol.load_adapter(DECK_RISER_NAME, "B2") | ||
|
||
lids: List[Labware] = [deck_riser_adapter.load_labware(LID_BOTTOM_DEFINITION)] | ||
for i in range(LID_COUNT - 1): | ||
lids.append(lids[-1].load_labware(LID_DEFINITION)) | ||
lids.reverse() # NOTE: reversing to more easily loop through lids from top-to-bottom | ||
if USING_THERMOCYCLER: | ||
# TODO: confirm if we need to load 96-well adapter onto Thermocycler | ||
thermocycler = protocol.load_module("thermocyclerModuleV2") | ||
thermocycler.open_lid() | ||
plate_in_cycler = thermocycler.load_labware("armadillo_96_wellplate_200ul_pcr_full_skirt") | ||
else: | ||
plate_in_cycler = None | ||
|
||
# RUN | ||
prev_moved_lid: Optional[Labware] = None | ||
for lid in lids: | ||
|
||
if USING_THERMOCYCLER: | ||
_move_labware_with_offset_and_pause( | ||
protocol, | ||
lid, | ||
plate_in_cycler, | ||
pick_up_offset=OFFSET_DECK["pick-up"], | ||
drop_offset=OFFSET_THERMOCYCLER["drop"], | ||
) | ||
_move_labware_with_offset_and_pause( | ||
protocol, | ||
lid, | ||
prev_moved_lid if prev_moved_lid else LID_ENDING_SLOT, | ||
pick_up_offset=OFFSET_THERMOCYCLER["pick-up"], | ||
drop_offset=OFFSET_DECK["drop"], | ||
) | ||
else: | ||
_move_labware_with_offset_and_pause( | ||
protocol, | ||
lid, | ||
prev_moved_lid if prev_moved_lid else LID_ENDING_SLOT, | ||
pick_up_offset=OFFSET_DECK["pick-up"], | ||
drop_offset=OFFSET_DECK["drop"], | ||
) | ||
prev_moved_lid = lid |
22 changes: 22 additions & 0 deletions
22
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_plate_reader_bad_slot.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,22 @@ | ||
from typing import cast | ||
from opentrons import protocol_api | ||
from opentrons.protocol_api.module_contexts import AbsorbanceReaderContext | ||
|
||
from opentrons import protocol_api | ||
from opentrons.protocol_api import SINGLE, ALL | ||
|
||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
metadata = {"protocolName": "plate_reader bad slot"} | ||
|
||
|
||
def run(protocol: protocol_api.ProtocolContext): | ||
partial_rack = protocol.load_labware(load_name="opentrons_flex_96_tiprack_1000ul", location="D3") | ||
trash = protocol.load_trash_bin("A3") | ||
instrument = protocol.load_instrument(instrument_name="flex_8channel_1000", mount="right") | ||
instrument.configure_nozzle_layout(style=SINGLE, start="H1", tip_racks=[partial_rack]) | ||
|
||
plate_1 = protocol.load_labware("nest_96_wellplate_200ul_flat", "D1") | ||
mod = protocol.load_module("absorbanceReaderV1", "C1") | ||
mod.open_lid() | ||
protocol.move_labware(plate_1, mod, use_gripper=True) | ||
mod.close_lid() |
88 changes: 88 additions & 0 deletions
88
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_plate_reader_no_close_lid.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,88 @@ | ||
from typing import cast | ||
from opentrons import protocol_api | ||
from opentrons.protocol_api.module_contexts import AbsorbanceReaderContext | ||
|
||
# metadata | ||
metadata = { | ||
"protocolName": "Absorbance Reader no close lid", | ||
"author": "Platform Expansion", | ||
} | ||
|
||
requirements = { | ||
"robotType": "Flex", | ||
"apiLevel": "2.21", | ||
} | ||
|
||
|
||
# protocol run function | ||
def run(protocol: protocol_api.ProtocolContext): | ||
mod = cast(AbsorbanceReaderContext, protocol.load_module("absorbanceReaderV1", "D3")) | ||
plate = protocol.load_labware("nest_96_wellplate_200ul_flat", "C2") | ||
tiprack_1000 = protocol.load_labware(load_name="opentrons_flex_96_tiprack_50ul", location="B2") | ||
trash_labware = protocol.load_trash_bin("B3") | ||
instrument = protocol.load_instrument("flex_8channel_50", "right", tip_racks=[tiprack_1000]) | ||
|
||
# pick up tip and perform action | ||
instrument.pick_up_tip(tiprack_1000.wells_by_name()["A1"]) | ||
instrument.aspirate(30, plate.wells_by_name()["A1"]) | ||
instrument.dispense(30, plate.wells_by_name()["B1"]) | ||
instrument.return_tip() | ||
|
||
# Initialize to a single wavelength with reference wavelength | ||
# Issue: Make sure there is no labware here or youll get an error | ||
# mod.close_lid() | ||
mod.initialize("single", [600], 450) | ||
|
||
# NOTE: CANNOT INITIALIZE WITH THE LID OPEN | ||
|
||
# Remove the Plate Reader lid using the Gripper. | ||
mod.open_lid() | ||
protocol.move_labware(plate, mod, use_gripper=True) | ||
mod.close_lid() | ||
|
||
# Take a reading and show the resulting absorbance values. | ||
# Issue: cant read before you initialize or you an get an error | ||
result = mod.read() | ||
msg = f"single: {result}" | ||
protocol.comment(msg=msg) | ||
protocol.pause(msg=msg) | ||
|
||
# Initialize to multiple wavelengths | ||
protocol.pause(msg="Perform Multi Read") | ||
mod.open_lid() | ||
protocol.move_labware(plate, "C2", use_gripper=True) | ||
|
||
mod.close_lid() | ||
|
||
# mod.initialize('multi', [450, 570, 600]) | ||
mod.initialize("multi", [450, 600]) | ||
# Open the lid and move the labware into the reader | ||
mod.open_lid() | ||
protocol.move_labware(plate, mod, use_gripper=True) | ||
|
||
# pick up tip and perform action on labware inside plate reader | ||
instrument.pick_up_tip(tiprack_1000.wells_by_name()["A1"]) | ||
instrument.aspirate(30, plate.wells_by_name()["A1"]) | ||
instrument.dispense(30, plate.wells_by_name()["B1"]) | ||
instrument.return_tip() | ||
|
||
mod.close_lid() | ||
|
||
# Take reading | ||
result = mod.read() | ||
msg = f"multi: {result}" | ||
protocol.comment(msg=msg) | ||
protocol.pause(msg=msg) | ||
|
||
# Take a reading and save to csv | ||
protocol.pause(msg="Perform Read and Save to CSV") | ||
result = mod.read(export_filename="plate_reader_csv.csv") | ||
msg = f"csv: {result}" | ||
protocol.pause(msg=msg) | ||
|
||
# Place the Plate Reader lid back on using the Gripper. | ||
mod.open_lid() | ||
protocol.move_labware(plate, "C2", use_gripper=True) | ||
mod.close_lid() | ||
|
||
mod.read(export_filename="csv_name.csv") |
24 changes: 24 additions & 0 deletions
24
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_plate_reader_no_trash.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,24 @@ | ||
from typing import cast | ||
from opentrons import protocol_api | ||
from opentrons.protocol_api.module_contexts import AbsorbanceReaderContext | ||
|
||
from opentrons import protocol_api | ||
from opentrons.protocol_api import SINGLE, ALL | ||
|
||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
metadata = {"protocolName": "plate_reader no trash"} | ||
|
||
|
||
def run(protocol: protocol_api.ProtocolContext): | ||
partial_rack = protocol.load_labware(load_name="opentrons_flex_96_tiprack_1000ul", location="D2") | ||
trash = protocol.load_trash_bin("A3") | ||
instrument = protocol.load_instrument(instrument_name="flex_8channel_1000", mount="right") | ||
instrument.configure_nozzle_layout(style=SINGLE, start="H1", tip_racks=[partial_rack]) | ||
|
||
plate_1 = protocol.load_labware("nest_96_wellplate_200ul_flat", "C1") | ||
|
||
mod = protocol.load_module("absorbanceReaderV1", "B3") | ||
|
||
mod.open_lid() | ||
protocol.move_labware(plate_1, mod, use_gripper=True) | ||
protocol.move_labware(plate_1, trash, use_gripper=True) |
24 changes: 24 additions & 0 deletions
24
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_plate_reader_wrong_plate.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,24 @@ | ||
from typing import cast | ||
from opentrons import protocol_api | ||
from opentrons.protocol_api.module_contexts import AbsorbanceReaderContext | ||
|
||
from opentrons import protocol_api | ||
from opentrons.protocol_api import SINGLE, ALL | ||
|
||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
metadata = {"protocolName": "plate_reader wrong plate"} | ||
|
||
|
||
def run(protocol: protocol_api.ProtocolContext): | ||
partial_rack = protocol.load_labware(load_name="opentrons_flex_96_tiprack_1000ul", location="D2") | ||
trash = protocol.load_trash_bin("A3") | ||
instrument = protocol.load_instrument(instrument_name="flex_8channel_1000", mount="right") | ||
instrument.configure_nozzle_layout(style=SINGLE, start="H1", tip_racks=[partial_rack]) | ||
|
||
plate_1 = protocol.load_labware("corning_12_wellplate_6.9ml_flat", "C2") | ||
|
||
mod = protocol.load_module("absorbanceReaderV1", "B3") | ||
|
||
mod.open_lid() | ||
protocol.move_labware(plate_1, mod, use_gripper=True) | ||
protocol.move_labware(plate_1, trash, use_gripper=True) |
24 changes: 24 additions & 0 deletions
24
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_plate_reader_wrong_plate2.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,24 @@ | ||
from typing import cast | ||
from opentrons import protocol_api | ||
from opentrons.protocol_api.module_contexts import AbsorbanceReaderContext | ||
|
||
from opentrons import protocol_api | ||
from opentrons.protocol_api import SINGLE, ALL | ||
|
||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
metadata = {"protocolName": "plate_reader wrong plate"} | ||
|
||
|
||
def run(protocol: protocol_api.ProtocolContext): | ||
partial_rack = protocol.load_labware(load_name="opentrons_flex_96_tiprack_1000ul", location="D2") | ||
trash = protocol.load_trash_bin("A3") | ||
instrument = protocol.load_instrument(instrument_name="flex_8channel_1000", mount="right") | ||
instrument.configure_nozzle_layout(style=SINGLE, start="H1", tip_racks=[partial_rack]) | ||
|
||
plate_1 = protocol.load_labware("thermoscientificnunc_96_wellplate_2000ul", "C2") | ||
|
||
mod = protocol.load_module("absorbanceReaderV1", "B3") | ||
|
||
mod.open_lid() | ||
protocol.move_labware(plate_1, mod, use_gripper=True) | ||
protocol.move_labware(plate_1, trash, use_gripper=True) |
26 changes: 26 additions & 0 deletions
26
analyses-snapshot-testing/files/protocols/Flex_X_v2_21_tc_lids_wrong_target.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,26 @@ | ||
from typing import List, Dict, Any, Optional | ||
from opentrons.protocol_api import ProtocolContext, Labware | ||
|
||
metadata = {"Stacking a deep well plate on its adapter "} | ||
requirements = {"robotType": "Flex", "apiLevel": "2.21"} | ||
|
||
|
||
def run(protocol: ProtocolContext): | ||
temp_mod = protocol.load_module(module_name="temperature module gen2", location="D1") | ||
LID_COUNT = 5 | ||
LID_DEFINITION = "opentrons_tough_pcr_auto_sealing_lid" | ||
LID_BOTTOM_DEFINITION = "opentrons_tough_pcr_auto_sealing_lid" | ||
adapter = temp_mod.load_adapter("opentrons_96_deep_well_temp_mod_adapter") | ||
stack = protocol.load_labware("nest_96_wellplate_2ml_deep", "A1") | ||
deck_riser_adapter = protocol.load_adapter("opentrons_flex_deck_riser", "B2") | ||
protocol.move_labware(stack, adapter) | ||
lids = [deck_riser_adapter.load_labware(LID_BOTTOM_DEFINITION, "D2")] | ||
for i in range(LID_COUNT - 1): | ||
lids.append(lids[-1].load_labware(LID_DEFINITION)) | ||
lids.reverse() # NOTE: reversing to more easily loop through lids from top-to-bottom | ||
|
||
protocol.move_labware( | ||
lids[0], | ||
stack, | ||
use_gripper=True, | ||
) |
Oops, something went wrong.
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
TY for the docs!