Add Legrand Keor PDU 800 reports [networkupstools/nut#616]
Signed-off-by: Jim Klimov <[email protected]>
- Loading branch information
Showing
2 changed files
with
97 additions
and
0 deletions.
There are no files selected for viewing
47 changes: 47 additions & 0 deletions
47
Legrand/Legrand__Keor_PDU_800__usbhid-ups__2.7.4.1__01.dev
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,47 @@ | ||
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/616#issuecomment-1166722226 | ||
|
||
# DEVICE:COMMENT-BLOCK: | ||
# Device support relies on code that went into NUT v2.8.0 release; | ||
# the report was done on a development snapshot so dubbed "2.7.4.1". | ||
# | ||
# It outputs the current of all devices, the PDU800 doesn't support | ||
# metrics per output plug. | ||
# DEVICE:EOC | ||
|
||
battery.charge: 100 | ||
battery.charge.low: 10 | ||
battery.charge.warning: 20 | ||
battery.runtime: 2520 | ||
battery.voltage: 1.4 | ||
battery.voltage.nominal: 1.2 | ||
device.mfr: Legrand | ||
device.model: KEOR PDU 800 | ||
device.serial: | ||
device.type: ups | ||
driver.name: usbhid-ups | ||
driver.parameter.pollfreq: 30 | ||
driver.parameter.pollinterval: 2 | ||
driver.parameter.port: auto | ||
driver.parameter.productid: 0038 | ||
driver.parameter.synchronous: no | ||
driver.parameter.vendorid: 1cb0 | ||
driver.version: 2.7.4-4539-gefb9ee45 | ||
driver.version.data: Legrand HID 0.2 | ||
driver.version.internal: 0.45 | ||
driver.version.usb: libusb-1.0.24 (API: 0x1000108) | ||
input.transfer.high: 270 | ||
input.transfer.low: 180 | ||
input.voltage: 236 | ||
input.voltage.nominal: 230 | ||
output.frequency: 50 | ||
output.voltage: 6 | ||
ups.delay.shutdown: 20 | ||
ups.delay.start: 30 | ||
ups.load: 20 | ||
ups.mfr: Legrand | ||
ups.model: KEOR PDU 800 | ||
ups.productid: 0038 | ||
ups.realpower.nominal: 480 | ||
ups.serial: | ||
ups.status: OL CHRG | ||
ups.vendorid: 1cb0 |
50 changes: 50 additions & 0 deletions
50
Legrand/Legrand__Keor_PDU_800__usbhid-ups__2.8.0.1__01.dev
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,50 @@ | ||
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/616#issuecomment-1640371303 | ||
|
||
# DEVICE:COMMENT-BLOCK: | ||
# Voltages seemed to be off by a factor of 10. So the report author | ||
# experimented with neutering of `divide_by_10_conversion()` and | ||
# `legrand_times10M_info()` in the mapping tables. | ||
# | ||
# NOTE: The report below is not from a stock NUT release (nor snapshot), | ||
# but from that experiment. Voltages are bumped (or rather not-nerfed | ||
# by default driver logic), `1.2` => `12` etc. | ||
# DEVICE:EOC | ||
|
||
battery.charge: 100 | ||
battery.charge.low: 10 | ||
battery.charge.warning: 20 | ||
battery.runtime: 1620 | ||
battery.voltage: 14 | ||
battery.voltage.nominal: 12 | ||
device.mfr: Legrand | ||
device.model: KEOR PDU 800 | ||
device.serial: | ||
device.type: ups | ||
driver.name: usbhid-ups | ||
driver.parameter.pollfreq: 30 | ||
driver.parameter.pollinterval: 15 | ||
driver.parameter.port: auto | ||
driver.parameter.productid: 0038 | ||
driver.parameter.synchronous: auto | ||
driver.parameter.vendorid: 1cb0 | ||
driver.state: quiet | ||
driver.version: 2.8.0-Windows-726-g73ee107fa | ||
driver.version.data: Legrand HID 0.2 | ||
driver.version.internal: 0.49 | ||
driver.version.usb: libusb-0.1 (or compat) | ||
input.transfer.high: 270 | ||
input.transfer.low: 180 | ||
input.voltage: 236 | ||
input.voltage.nominal: 230 | ||
output.frequency: 50 | ||
output.voltage: 235.6 | ||
ups.delay.shutdown: 20 | ||
ups.delay.start: 30 | ||
ups.load: 32 | ||
ups.mfr: Legrand | ||
ups.model: KEOR PDU 800 | ||
ups.productid: 0038 | ||
ups.realpower.nominal: 480 | ||
ups.serial: | ||
ups.status: OL CHRG | ||
ups.vendorid: 1cb0 |