Add Legrand Keor PDU 800 reports [networkupstools/nut#616]
Browse files Browse the repository at this point in the history
Signed-off-by: Jim Klimov <[email protected]>
  • Loading branch information
jimklimov committed Aug 31, 2023
1 parent a3f5081 commit 7355136
Show file tree
Hide file tree
Showing 2 changed files with 97 additions and 0 deletions.
47 changes: 47 additions & 0 deletions Legrand/Legrand__Keor_PDU_800__usbhid-ups__2.7.4.1__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,47 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/616#issuecomment-1166722226

# DEVICE:COMMENT-BLOCK:
# Device support relies on code that went into NUT v2.8.0 release;
# the report was done on a development snapshot so dubbed "2.7.4.1".
#
# It outputs the current of all devices, the PDU800 doesn't support
# metrics per output plug.
# DEVICE:EOC

battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.runtime: 2520
battery.voltage: 1.4
battery.voltage.nominal: 1.2
device.mfr: Legrand
device.model: KEOR PDU 800
device.serial:
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.productid: 0038
driver.parameter.synchronous: no
driver.parameter.vendorid: 1cb0
driver.version: 2.7.4-4539-gefb9ee45
driver.version.data: Legrand HID 0.2
driver.version.internal: 0.45
driver.version.usb: libusb-1.0.24 (API: 0x1000108)
input.transfer.high: 270
input.transfer.low: 180
input.voltage: 236
input.voltage.nominal: 230
output.frequency: 50
output.voltage: 6
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 20
ups.mfr: Legrand
ups.model: KEOR PDU 800
ups.productid: 0038
ups.realpower.nominal: 480
ups.serial:
ups.status: OL CHRG
ups.vendorid: 1cb0
50 changes: 50 additions & 0 deletions Legrand/Legrand__Keor_PDU_800__usbhid-ups__2.8.0.1__01.dev
Original file line number Diff line number Diff line change
@@ -0,0 +1,50 @@
# DEVICE:URL:REPORT: https://github.com/networkupstools/nut/issues/616#issuecomment-1640371303

# DEVICE:COMMENT-BLOCK:
# Voltages seemed to be off by a factor of 10. So the report author
# experimented with neutering of `divide_by_10_conversion()` and
# `legrand_times10M_info()` in the mapping tables.
#
# NOTE: The report below is not from a stock NUT release (nor snapshot),
# but from that experiment. Voltages are bumped (or rather not-nerfed
# by default driver logic), `1.2` => `12` etc.
# DEVICE:EOC

battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.runtime: 1620
battery.voltage: 14
battery.voltage.nominal: 12
device.mfr: Legrand
device.model: KEOR PDU 800
device.serial:
device.type: ups
driver.name: usbhid-ups
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 15
driver.parameter.port: auto
driver.parameter.productid: 0038
driver.parameter.synchronous: auto
driver.parameter.vendorid: 1cb0
driver.state: quiet
driver.version: 2.8.0-Windows-726-g73ee107fa
driver.version.data: Legrand HID 0.2
driver.version.internal: 0.49
driver.version.usb: libusb-0.1 (or compat)
input.transfer.high: 270
input.transfer.low: 180
input.voltage: 236
input.voltage.nominal: 230
output.frequency: 50
output.voltage: 235.6
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 32
ups.mfr: Legrand
ups.model: KEOR PDU 800
ups.productid: 0038
ups.realpower.nominal: 480
ups.serial:
ups.status: OL CHRG
ups.vendorid: 1cb0