Skip to content

Commit

Permalink
Merge pull request #2704 from desertwitch/2660-follow-up
Browse files Browse the repository at this point in the history
drivers/mge-hid.c: comment regarding ChargerType
  • Loading branch information
jimklimov authored Dec 1, 2024
2 parents f99109d + 7964426 commit 368e734
Showing 1 changed file with 27 additions and 5 deletions.
32 changes: 27 additions & 5 deletions drivers/mge-hid.c
Original file line number Diff line number Diff line change
Expand Up @@ -159,7 +159,6 @@ static char mge_scratch_buf[20];
* Synthesis table
* HID data | Charger in ABM mode | Charger in Constant mode | Error | Good |
* UPS.BatterySystem.Charger.ABMEnable | 1 | 0 | | |
* UPS.BatterySystem.Charger.ChargerType | 4 | 5 | | |
* UPS.PowerSummary.PresentStatus.ACPresent | On utility | On battery | On utility | On battery | | |
* Charger ABM mode | Charging | Floating | Resting | Discharging | Disabled | Disabled | | |
* UPS.BatterySystem.Charger.Mode | 1 | 3 | 4 | 2 | 6 | 6 | | |
Expand All @@ -168,6 +167,7 @@ static char mge_scratch_buf[20];
* UPS.PowerSummary.PresentStatus.Discharging | 0 |  0 |  0 | 1 | 0 | 1 | | |
*
* Notes (from David G. Miller) to understand ABM status:
*
* When supporting ABM, when a UPS powers up or returns from battery, or
* ends the ABM rest mode, it enters charge mode.
* Some UPSs run a different charger reference voltage during charge mode
Expand All @@ -191,7 +191,29 @@ static char mge_scratch_buf[20];
* reporting "off" in the ABM charger status.
* Of course when delivering load power from the battery, the ABM status is
* discharging.
*/
*
* UPS.BatterySystem.Charger.ChargerType:
*
* This HID path has been seen to denote the charger type of the UPS.
* At present it is unclear whether deductions about ABM being enabled
* should be made from it, even though it seems to be changing when a
* UPS that is ABM-capable is manually enabling and disabling its ABM.
* For example, the Eaton 5P850I has been seen with a ChargerType of 0
* when having ABM disabled, and ChargerType of 4 when ABM was enabled.
* According to the known values, however, the ChargerType should have
* either remained the same (if only to display general charger ability)
* or changed to ChargerType of 5 (for constant charge mode) - and not 0:
*
* { 0, "None", NULL, NULL },
* { 1, "Extended (CLA)", NULL, NULL },
* { 2, "Large extension", NULL, NULL },
* { 3, "Extra large extension (XL)", NULL, NULL },
* { 4, "ABM", NULL, NULL },
* { 5, "Constant Charge (CC)", NULL, NULL },
*
* For this reason, ABM being enabled remains controlled only through the
* one HID path known to be consistent: UPS.BatterySystem.Charger.ABMEnable
*/

#define ABM_UNKNOWN -1
#define ABM_DISABLED 0
Expand Down Expand Up @@ -267,7 +289,7 @@ static const char *eaton_abm_path_mode_fun(double value)
int abm_path_mode_value = (int)value;

/* If unknown/disabled ABM, reset ABM path to give UPS a chance to use another once re-enabled */
if(advanced_battery_monitoring == ABM_UNKNOWN || advanced_battery_monitoring == ABM_DISABLED) {
if (advanced_battery_monitoring == ABM_UNKNOWN || advanced_battery_monitoring == ABM_DISABLED) {
advanced_battery_path = ABM_PATH_UNKNOWN;
return NULL;
}
Expand All @@ -294,7 +316,7 @@ static const char *eaton_abm_path_status_fun(double value)
int abm_path_status_value = (int)value;

/* If unknown/disabled ABM, reset ABM path to give UPS a chance to use another once re-enabled */
if(advanced_battery_monitoring == ABM_UNKNOWN || advanced_battery_monitoring == ABM_DISABLED) {
if (advanced_battery_monitoring == ABM_UNKNOWN || advanced_battery_monitoring == ABM_DISABLED) {
advanced_battery_path = ABM_PATH_UNKNOWN;
return NULL;
}
Expand Down Expand Up @@ -1979,7 +2001,7 @@ static char *get_model_name(const char *iProduct, const char *iModel)

/* Search for device type and formatting rules */
for (model = mge_model_names; model->iProduct; model++) {
if(model->name) {
if (model->name) {
upsdebugx(2, "comparing with: %s", model->name);
}
else {
Expand Down

0 comments on commit 368e734