Add hwp_pcu agent for the hwp phase compensation unit operations (#588)
* hwp_pcu is added. * Update agent.py * Update agent.py * Update hwp_pcu.py * [pre-commit.ci] auto fixes from pre-commit.com hooks for more information, see https://pre-commit.ci * Update agent.py * make timeout longer and small fixes * fix get_status * fix send_command * add draft of docs * update draft of docs * small fixes of docs --------- Co-authored-by: pre-commit-ci[bot] <66853113+pre-commit-ci[bot]@users.noreply.github.com> Co-authored-by: ykyohei <[email protected]>
- Loading branch information
1 parent
8eedcd7
commit 2588a8e
Showing
6 changed files
with
414 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,87 @@ | ||
.. highlight:: rst | ||
|
||
.. _hwp_pcu: | ||
|
||
============= | ||
HWP PCU Agent | ||
============= | ||
|
||
The HWP Phase Compensation Unit Agent interfaces with a 8 channel USB relay module | ||
(Numato Lab, product Number SKU:RL80001) to apply the discrete phase compensation in | ||
120-degree increments for the HWP motor drive circuit. When used in conjunction with | ||
a HWP pid controller, phase compensation in 60-degree increments can be achieved. | ||
|
||
.. argparse:: | ||
:filename: ../socs/agents/hwp_pcu/agent.py | ||
:func: make_parser | ||
:prog: python3 agent.py | ||
|
||
Configuration File Examples | ||
--------------------------- | ||
|
||
Below are configuration examples for the ocs config file and for running the | ||
Agent in a docker container. | ||
|
||
OCS Site Config | ||
``````````````` | ||
|
||
To configure your HWP PCU Agent for use with OCS you need to add a | ||
HWPPCUAgent block to your ocs configuration file. Here is an example | ||
configuration block that will automatically start data acquisition:: | ||
|
||
{'agent-class': 'HWPPCUAgent', | ||
'instance-id': 'hwp-pcu', | ||
'arguments': [['--port', '/dev/HWPPCU'], | ||
['--mode', 'acq']]}, | ||
|
||
Each device requires configuration under 'agent-instances'. See the OCS site | ||
configs documentation for more details. | ||
|
||
Docker Compose | ||
`````````````` | ||
|
||
The HWP PCU Agent can (and probably should) be configured to run in a | ||
Docker container. An example configuration is:: | ||
|
||
ocs-hwp-pcu: | ||
image: simonsobs/socs:latest | ||
devices: | ||
- "/dev/HWPPCU:/dev/HWPPCU" | ||
hostname: nuc-docker | ||
environment: | ||
- INSTANCE_ID=hwp-pcu | ||
volumes: | ||
- ${OCS_CONFIG_DIR}:/config:ro | ||
|
||
The serial number will need to be updated in your configuration. The hostname | ||
should also match your configured host in your OCS configuration file. The | ||
site-hub and site-http need to point to your crossbar server, as described in | ||
the OCS documentation. | ||
|
||
|
||
Example Clients | ||
--------------- | ||
|
||
To apply 120-degree phase compensation:: | ||
|
||
from ocs.matched_client import MatchedClient | ||
|
||
hwp_pcu_client = MatchedClient("HWPPCU") | ||
|
||
hwp_pcu_client.set_command(command='on_1') | ||
|
||
To apply 60 (= -120 + 180) degree phase compensation:: | ||
|
||
from ocs.matched_client import MatchedClient | ||
|
||
hwp_pcu_client = MatchedClient("HWPPCU") | ||
hwp_pid_client = MatchedClient("HWPPID") | ||
|
||
hwp_pcu_client.set_command(command='on_2') | ||
hwp_pid_client.set_direction(direction=1) | ||
|
||
Agent API | ||
--------- | ||
|
||
.. autoclass:: socs.agents.hwp_pcu.agent.HWPPCUAgent | ||
:members: |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Empty file.
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,253 @@ | ||
import argparse | ||
import time | ||
|
||
from ocs import ocs_agent, site_config | ||
from ocs.ocs_twisted import TimeoutLock | ||
from twisted.internet import reactor | ||
|
||
import socs.agents.hwp_pcu.drivers.hwp_pcu as pcu | ||
|
||
|
||
class HWPPCUAgent: | ||
"""Agent to phase compensation improve the CHWP motor efficiency | ||
Args: | ||
agent (ocs.ocs_agent.OCSAgent): Instantiated OCSAgent class for this agent | ||
port (str): Path to USB device in '/dev/' | ||
""" | ||
|
||
def __init__(self, agent, port): | ||
self.agent: ocs_agent.OCSAgent = agent | ||
self.log = agent.log | ||
self.lock = TimeoutLock() | ||
self.initialized = False | ||
self.take_data = False | ||
self.port = port | ||
self.status = 'off' | ||
|
||
agg_params = {'frame_length': 60} | ||
self.agent.register_feed( | ||
'hwppcu', record=True, agg_params=agg_params) | ||
|
||
@ocs_agent.param('auto_acquire', default=False, type=bool) | ||
@ocs_agent.param('force', default=False, type=bool) | ||
def init_connection(self, session, params): | ||
"""init_connection(auto_acquire=False, force=False) | ||
**Task** - Initialize connection to PCU | ||
Controller. | ||
Parameters: | ||
auto_acquire (bool, optional): Default is False. Starts data | ||
acquisition after initialization if True. | ||
force (bool, optional): Force initialization, even if already | ||
initialized. Defaults to False. | ||
""" | ||
if self.initialized and not params['force']: | ||
self.log.info("Connection already initialized. Returning...") | ||
return True, "Connection already initialized" | ||
|
||
with self.lock.acquire_timeout(3, job='init_connection') as acquired: | ||
if not acquired: | ||
self.log.warn( | ||
'Could not run init_connection because {} is already running'.format(self.lock.job)) | ||
return False, 'Could not acquire lock' | ||
|
||
try: | ||
self.PCU = pcu.PCU(port=self.port) | ||
self.log.info('Connected to PCU') | ||
except BrokenPipeError: | ||
self.log.error('Could not establish connection to PCU') | ||
reactor.callFromThread(reactor.stop) | ||
return False, 'Unable to connect to PCU' | ||
|
||
self.status = self.PCU.get_status() | ||
self.initialized = True | ||
|
||
# Start 'acq' Process if requested | ||
if params['auto_acquire']: | ||
self.agent.start('acq') | ||
|
||
return True, 'Connection to PCU established' | ||
|
||
@ocs_agent.param('command', default='off', type=str, choices=['off', 'on_1', 'on_2', 'hold']) | ||
def send_command(self, session, params): | ||
"""send_command(command) | ||
**Task** - Send commands to the phase compensation unit. | ||
off: The compensation phase is zero. | ||
on_1: The compensation phase is +120 deg. | ||
on_2: The compensation phase is -120 deg. | ||
hold: Stop the HWP spin. | ||
Parameters: | ||
command (str): set the operation mode from 'off', 'on_1', 'on_2' or 'hold'. | ||
""" | ||
with self.lock.acquire_timeout(3, job='send_command') as acquired: | ||
if not acquired: | ||
self.log.warn('Could not send command because {} is already running'.format(self.lock.job)) | ||
return False, 'Could not acquire lock' | ||
|
||
command = params['command'] | ||
if command == 'off': | ||
off_channel = [0, 1, 2, 5, 6, 7] | ||
for i in off_channel: | ||
self.PCU.relay_off(i) | ||
self.status = 'off' | ||
return True, 'Phase compensation is "off".' | ||
|
||
elif command == 'on_1': | ||
on_channel = [0, 1, 2] | ||
off_channel = [5, 6, 7] | ||
for i in on_channel: | ||
self.PCU.relay_on(i) | ||
for i in off_channel: | ||
self.PCU.relay_off(i) | ||
self.status = 'on_1' | ||
return True, 'Phase compensation operates "on_1".' | ||
|
||
elif command == 'on_2': | ||
on_channel = [0, 1, 2, 5, 6, 7] | ||
for i in on_channel: | ||
self.PCU.relay_on(i) | ||
self.status = 'on_2' | ||
return True, 'Phase compensation operates "on_2".' | ||
|
||
elif command == 'hold': | ||
on_channel = [0, 1, 2, 5] | ||
off_channel = [6, 7] | ||
for i in on_channel: | ||
self.PCU.relay_on(i) | ||
for i in off_channel: | ||
self.PCU.relay_off(i) | ||
self.status = 'hold' | ||
return True, 'Phase compensation operates "hold".' | ||
|
||
else: | ||
return True, "Choose the command from 'off', 'on_1', 'on_2' and 'hold'." | ||
|
||
def get_status(self, session, params): | ||
"""get_status() | ||
**Task** - Return the status of the PCU. | ||
""" | ||
with self.lock.acquire_timeout(3, job='get_status') as acquired: | ||
if not acquired: | ||
self.log.warn( | ||
'Could not get status because {} is already running'.format(self.lock.job)) | ||
return False, 'Could not acquire lock' | ||
|
||
self.status = self.PCU.get_status() | ||
|
||
return True, 'Current status is ' + self.status | ||
|
||
def acq(self, session, params): | ||
"""acq() | ||
**Process** - Start PCU data acquisition. | ||
Notes: | ||
The most recent data collected is stored in the session data in the | ||
structure:: | ||
>>> response.session['data'] | ||
{'status': 'on_1', | ||
'last_updated': 1649085992.719602} | ||
""" | ||
with self.lock.acquire_timeout(timeout=3, job='acq') as acquired: | ||
if not acquired: | ||
self.log.warn('Could not start pcu acq because {} is already running' | ||
.format(self.lock.job)) | ||
return False, 'Could not acquire lock' | ||
|
||
session.set_status('running') | ||
last_release = time.time() | ||
self.take_data = True | ||
|
||
while self.take_data: | ||
# Relinquish sampling lock occasionally. | ||
if time.time() - last_release > 1.: | ||
last_release = time.time() | ||
if not self.lock.release_and_acquire(timeout=10): | ||
self.log.warn(f"Failed to re-acquire sampling lock, " | ||
f"currently held by {self.lock.job}.") | ||
continue | ||
|
||
data = {'timestamp': time.time(), | ||
'block_name': 'hwppcu', 'data': {}} | ||
|
||
# status = self.PCU.get_status() | ||
status = self.status | ||
data['data']['status'] = status | ||
|
||
self.agent.publish_to_feed('hwppcu', data) | ||
|
||
session.data = {'status': status, | ||
'last_updated': time.time()} | ||
|
||
time.sleep(5) | ||
|
||
self.agent.feeds['hwppcu'].flush_buffer() | ||
return True, 'Acqusition exited cleanly' | ||
|
||
def _stop_acq(self, session, params): | ||
""" | ||
Stop acq process. | ||
""" | ||
if self.take_data: | ||
self.PCU.close() | ||
self.take_data = False | ||
return True, 'requested to stop taking data' | ||
|
||
return False, 'acq is not currently running' | ||
|
||
|
||
def make_parser(parser=None): | ||
""" | ||
Build the argument parser for the Agent. Allows sphinx to automatically build documentation | ||
baised on this function | ||
""" | ||
if parser is None: | ||
parser = argparse.ArgumentParser() | ||
|
||
# Add options specific to this agent | ||
pgroup = parser.add_argument_group('Agent Options') | ||
pgroup.add_argument('--port', type=str, help="Path to USB node for the lakeshore") | ||
pgroup.add_argument('--mode', type=str, default='acq', | ||
choices=['init', 'acq'], | ||
help="Starting operation for the Agent.") | ||
return parser | ||
|
||
|
||
def main(args=None): | ||
parser = make_parser() | ||
args = site_config.parse_args(agent_class='HWPPCUAgent', | ||
parser=parser, | ||
args=args) | ||
|
||
init_params = False | ||
if args.mode == 'init': | ||
init_params = {'auto_acquire': False} | ||
elif args.mode == 'acq': | ||
init_params = {'auto_acquire': True} | ||
|
||
agent, runner = ocs_agent.init_site_agent(args) | ||
hwppcu_agent = HWPPCUAgent(agent, | ||
port=args.port) | ||
agent.register_task('init_connection', hwppcu_agent.init_connection, | ||
startup=init_params) | ||
agent.register_process('acq', hwppcu_agent.acq, | ||
hwppcu_agent._stop_acq) | ||
agent.register_task('send_command', hwppcu_agent.send_command) | ||
agent.register_task('get_status', hwppcu_agent.get_status) | ||
|
||
runner.run(agent, auto_reconnect=True) | ||
|
||
|
||
if __name__ == '__main__': | ||
main() |
Empty file.